Fiber Optic
Omron
[OMRON] — E32 Special Application Fiber Units (Liquid-level, Vacuum, FPD/Semiconductor/Solar)
Family ID: OMRON-E32-APPS
OMRON E32 Series special application fiber units for industrial process environments. Liquid-level detection: E32-A01 (tube-mounting 3.2~9.5 dia., 5 m cable), E32-L25T (8~10 dia. multilevel), E32-D36T (large diameter tubes, IP67), E32-D82F1 (liquid-contact type, heat-resistant 200°C, IP68). Vacuum-resistant: E32-T51V (vacuum side, 120°C, 1 m), E32-T84SV (vacuum side, 200°C, 1 m), E32-T10V (atmospheric pressure side, 70°C, 2 m). FPD/Semiconductor/Solar limited-reflective: E32-A08 (glass substrate alignment, 70°C), E32-A12 (long-distance glass alignment), E32-A09 (glass substrate mapping). Wafer mapping (narrow view): E32-A03-2 (1.5°, -40~+85°C special), E32-A04-1 / E32-A04-8 (3.4° variants). PDF ref: E32 full catalog, Liquid-level / Vacuum / FPD sections.
13 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| E32-A01 5M | Liquid-level tube-mounting 3.2~9.5 dia., bend-resistant R4, IP50, 5m cable | OMRON | Model: E32-A01 5M | Type: Liquid-level Detection (Tube-mounting) | Applicable Tube Dia.: 3.2, 6.4, or 9.5 dia. transparent tube (wall thickness ~1 mm) | Bending Radius: Bend-resistant R4 | IP Rating: IP50 | Cable Length: 5 m (Free Cutting) | Note: Resistant to bubbles and droplets; residual quantity detection | ||
| E32-L25T 2M | Liquid-level tube-mounting 8~10 dia. multilevel, R10, IP50 | OMRON | Model: E32-L25T 2M | Type: Liquid-level Detection (Tube-mounting, Multilevel) | Applicable Tube Dia.: 8 to 10 dia. transparent tube (wall thickness ~1 mm) | Bending Radius: R10 | IP Rating: IP50 | Cable Length: 2 m (Free Cutting) | Note: Ideal for multi-level mounting | ||
| E32-D36T 2M | Liquid-level no tube diameter restriction, flexible R4, IP67 | OMRON | Model: E32-D36T 2M | Type: Liquid-level Detection (Universal) | Applicable Tube Dia.: No restrictions on diameter (transparent tube) | Bending Radius: R4 | IP Rating: IP67 | Cable Length: 2 m (Free Cutting) | Note: Resistant to bubbles and droplets; usable on large diameter tubes | ||
| E32-D82F1 4M | Liquid-contact heat-resistant 200°C, IP68, sensing section R40 / fiber R25, 4m cable | OMRON | Model: E32-D82F1 4M | Type: Liquid-level Detection (Liquid-contact, Heat-resistant) | Heat Resistance: 200°C | IP Rating: IP68 | Bending Radius: Sensing section R40 / Fiber R25 | Cable Length: 4 m (Free Cutting) | Note: Liquid-contact type; adjust received light via amplifier instruction sheet | ||
| E32-T51V 1M | Vacuum-resistant 120°C through-beam vacuum side, 1.2 dia., R30, 1m cable | OMRON | Model: E32-T51V 1M | Type: Through-beam Vacuum-resistant (Vacuum Side) | Heat Resistance: 120°C | Optical Axis Dia.: 1.2 dia. | Bending Radius: R30 | Cable Length: 1 m | Sensing Dist. ZV ST: 400 mm | Sensing Dist. FA ST: 600 mm | Min. Sensing Object: 10 μm dia. / 4 μm dia. | Note: For use in vacuum chambers; pair with E32-T10V on atmospheric side | ||
| E32-T84SV 1M | Vacuum-resistant 200°C through-beam vacuum side, 2 dia., R25, 1m cable | OMRON | Model: E32-T84SV 1M | Type: Through-beam Vacuum-resistant (Vacuum Side) | Heat Resistance: 200°C | Optical Axis Dia.: 2 dia. | Bending Radius: R25 | Cable Length: 1 m | Sensing Dist. ZV ST: 950 mm | Sensing Dist. FA ST: 1,420 mm | Min. Sensing Object: 0.1 dia. / 0.03 dia. | ||
| E32-T10V 2M | Vacuum-resistant through-beam atmospheric pressure side, 70°C, 2m cable | OMRON | Model: E32-T10V 2M | Type: Through-beam Vacuum-resistant (Atmospheric Pressure Side) | Heat Resistance: 70°C | Cable Length: 2 m | Note: Atmospheric pressure side unit; pair with E32-T51V or E32-T84SV in vacuum | ||
| E32-A08 2M | FPD glass substrate alignment limited-reflective, 10~20 mm range, 70°C, R25, IP40 | OMRON | Model: E32-A08 2M | Type: Limited-reflective (Glass Substrate Alignment) | Ambient Temperature: 70°C max. | Bending Radius: R25 | IP Rating: IP40 | Cable Length: 2 m (Free Cutting) | Sensing Range: 10 to 20 mm | Standard Sensing Object: Soda glass with reflection factor of 7% | Note: If background interference occurs, perform power tuning | ||
| E32-A12 2M | FPD glass substrate alignment long-distance, 12~30 mm range, 70°C, R25, IP40 | OMRON | Model: E32-A12 2M | Type: Limited-reflective (Glass Substrate Alignment, Long Distance) | Ambient Temperature: 70°C max. | Bending Radius: R25 | IP Rating: IP40 | Cable Length: 2 m (Free Cutting) | Sensing Range: 12 to 30 mm | Standard Sensing Object: Soda glass with reflection factor of 7% | ||
| E32-A09 2M | FPD glass substrate mapping, 15~38 mm range (center 25 mm), 70°C, R25, IP40 | OMRON | Model: E32-A09 2M | Type: Limited-reflective (Glass Substrate Mapping) | Ambient Temperature: 70°C max. | Bending Radius: R25 | IP Rating: IP40 | Cable Length: 2 m (Free Cutting) | Sensing Range: 15 to 38 mm (center 25 mm) | Standard Sensing Object: End surface of soda glass t=0.7 mm, rounded edges | ||
| E32-A03-2 2M | Wafer mapping 1.5° narrow view through-beam, special temp range, R10, IP50 | OMRON | Model: E32-A03-2 2M | Type: Through-beam Narrow View (Wafer Mapping) | Aperture Angle: 1.5° | Bending Radius: R10 | IP Rating: IP50 | Cable Length: 2 m (Free Cutting) | Sensing Dist. ZV ST: 1,400 mm | Sensing Dist. FA ST: 1,400 mm | Note: Special temperature range variant for wafer mapping applications | ||
| E32-A04-1 2M | Wafer mapping 3.4° narrow view through-beam, 1.2 dia., R10, IP50 | OMRON | Model: E32-A04-1 2M | Type: Through-beam Narrow View (Wafer Mapping) | Aperture Angle: 3.4° | Profile Thickness: 2 mm | Optical Axis Dia.: 1.2 dia. | Bending Radius: R10 | IP Rating: IP50 | Cable Length: 2 m (Free Cutting) | Sensing Dist. ZV ST: 680 mm | Sensing Dist. FA ST: 1,020 mm | Min. Sensing Object: 0.1 dia. / 0.03 dia. | ||
| E32-A04-8 2M | Wafer mapping 3.4° narrow view through-beam reduced power, R10, IP50 | OMRON | Model: E32-A04-8 2M | Type: Through-beam Narrow View (Wafer Mapping, Reduced Power) | Aperture Angle: 3.4° | Bending Radius: R10 | IP Rating: IP50 | Cable Length: 2 m (Free Cutting) | Sensing Dist. ZV ST: 510 mm | Sensing Dist. FA ST: 760 mm | Note: Reduced incident power variant for sensitive workpiece applications |