[OMRON] — E3Z-UL Diffuse / Limited / Distance-settable Photoelectric Sensor (NPN/PNP, UL Certified)

[OMRON] — E3Z-UL Diffuse / Limited / Distance-settable Photoelectric Sensor (NPN/PNP, UL Certified)

Family ID: OMRON-E3Z-UL-DIFFUSE

OMRON E3Z Series UL certified reflective photoelectric sensors. Diffuse wide (E3Z-D61/81-UL): 5~100 mm. Diffuse 1m (E3Z-D62/82-UL). Narrow beam (E3Z-L61/81-UL): 90±30 mm. Limited (E3Z-L63/83-UL): 30±20 mm. Distance-settable BGS/FGS (E3Z-LS61/81-UL): 20~200 mm. Distance-settable short (E3Z-LS63/83-UL): 2~80 mm. NPN and PNP. Pre-wired 2 m and M8 connector.

24 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
E3Z-D61-UL 2M UL Diffuse-reflective 5~100 mm (wide view) NPN 2m OMRON Sensing Distance: 5~100 mm (wide view) | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-D66-UL UL Diffuse-reflective 5~100 mm (wide view) NPN M8 OMRON Sensing Distance: 5~100 mm (wide view) | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-D81-UL 2M UL Diffuse-reflective 5~100 mm (wide view) PNP 2m OMRON Sensing Distance: 5~100 mm (wide view) | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-D86-UL UL Diffuse-reflective 5~100 mm (wide view) PNP M8 OMRON Sensing Distance: 5~100 mm (wide view) | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-D62-UL 2M UL Diffuse-reflective 1 m NPN 2m OMRON Sensing Distance: 1 m | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-D67-UL UL Diffuse-reflective 1 m NPN M8 OMRON Sensing Distance: 1 m | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-D82-UL 2M UL Diffuse-reflective 1 m PNP 2m OMRON Sensing Distance: 1 m | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-D87-UL UL Diffuse-reflective 1 m PNP M8 OMRON Sensing Distance: 1 m | Light Source: Infrared | Sensing Method: Diffuse-reflective (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-L61-UL 2M UL Diffuse-reflective narrow beam 90±30 mm (narrow) NPN 2m OMRON Sensing Distance: 90±30 mm (narrow) | Light Source: Red light | Sensing Method: Diffuse-reflective narrow beam (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-L66-UL UL Diffuse-reflective narrow beam 90±30 mm (narrow) NPN M8 OMRON Sensing Distance: 90±30 mm (narrow) | Light Source: Red light | Sensing Method: Diffuse-reflective narrow beam (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-L81-UL 2M UL Diffuse-reflective narrow beam 90±30 mm (narrow) PNP 2m OMRON Sensing Distance: 90±30 mm (narrow) | Light Source: Red light | Sensing Method: Diffuse-reflective narrow beam (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-L86-UL UL Diffuse-reflective narrow beam 90±30 mm (narrow) PNP M8 OMRON Sensing Distance: 90±30 mm (narrow) | Light Source: Red light | Sensing Method: Diffuse-reflective narrow beam (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-L63-UL 2M UL Limited-reflective (transparent glass) 30±20 mm NPN 2m OMRON Sensing Distance: 30±20 mm | Light Source: Red light | Sensing Method: Limited-reflective (transparent glass) (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-L68-UL UL Limited-reflective (transparent glass) 30±20 mm NPN M8 OMRON Sensing Distance: 30±20 mm | Light Source: Red light | Sensing Method: Limited-reflective (transparent glass) (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-L83-UL 2M UL Limited-reflective (transparent glass) 30±20 mm PNP 2m OMRON Sensing Distance: 30±20 mm | Light Source: Red light | Sensing Method: Limited-reflective (transparent glass) (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-L88-UL UL Limited-reflective (transparent glass) 30±20 mm PNP M8 OMRON Sensing Distance: 30±20 mm | Light Source: Red light | Sensing Method: Limited-reflective (transparent glass) (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-LS61-UL 2M UL Distance-settable BGS/FGS BGS: 20~200 mm / FGS: 40+ mm NPN 2m OMRON Sensing Distance: BGS: 20~200 mm / FGS: 40+ mm | Light Source: Red light | Sensing Method: Distance-settable BGS/FGS (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-LS66-UL UL Distance-settable BGS/FGS BGS: 20~200 mm / FGS: 40+ mm NPN M8 OMRON Sensing Distance: BGS: 20~200 mm / FGS: 40+ mm | Light Source: Red light | Sensing Method: Distance-settable BGS/FGS (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-LS81-UL 2M UL Distance-settable BGS/FGS BGS: 20~200 mm / FGS: 40+ mm PNP 2m OMRON Sensing Distance: BGS: 20~200 mm / FGS: 40+ mm | Light Source: Red light | Sensing Method: Distance-settable BGS/FGS (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-LS86-UL UL Distance-settable BGS/FGS BGS: 20~200 mm / FGS: 40+ mm PNP M8 OMRON Sensing Distance: BGS: 20~200 mm / FGS: 40+ mm | Light Source: Red light | Sensing Method: Distance-settable BGS/FGS (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-LS63-UL 2M UL Distance-settable BGS short range BGS: 2~80 mm NPN 2m OMRON Sensing Distance: BGS: 2~80 mm | Light Source: Red light | Sensing Method: Distance-settable BGS short range (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-LS68-UL UL Distance-settable BGS short range BGS: 2~80 mm NPN M8 OMRON Sensing Distance: BGS: 2~80 mm | Light Source: Red light | Sensing Method: Distance-settable BGS short range (UL certified) | Output: NPN | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)
E3Z-LS83-UL 2M UL Distance-settable BGS short range BGS: 2~80 mm PNP 2m OMRON Sensing Distance: BGS: 2~80 mm | Light Source: Red light | Sensing Method: Distance-settable BGS short range (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m
E3Z-LS88-UL UL Distance-settable BGS short range BGS: 2~80 mm PNP M8 OMRON Sensing Distance: BGS: 2~80 mm | Light Source: Red light | Sensing Method: Distance-settable BGS short range (UL certified) | Output: PNP | Certification: UL | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately)