Skip to product information
1 of 1

CKD Precision Regulator RP1000/RP2000 Series (Clean Spec P70)

CKD Precision Regulator RP1000/RP2000 Series (Clean Spec P70)

Precision regulators for clean-room use with exhaust-treatment (P70) construction.

Key features

  • RP1000 (Rc1/4) offers set ranges up to 0.2, 0.4 or 0.7 MPa with sensitivity within 0.1% of full span; RP2000 (Rc1/4 or Rc3/8) covers 0.03-0.85 MPa
  • Versions with attached pressure gauge are available

Specifications

Max working pressure (MPa) 1.0
Repeatability within +/-0.5% of full span
Gauge port Rc1/8
Ambient/fluid temp (C) -5 to 50
Clean spec P70 (exhaust treatment)
RP1000-8-02-P70 Port size: Rc1/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 1.3 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)
RP1000-8-02-P70-GX49 Port size: Rc1/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 1.3 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P02-P70 (brass)
RP1000-8-02-P70-GY49 Port size: Rc1/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 1.3 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P02-P94 (stainless)
RP1000-8-04-P70 Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)
RP1000-8-04-P70-GX49 Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P04-P70 (brass)
RP1000-8-04-P70-GY49 Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P04-P94 (stainless)
RP1000-8-07-P70 Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)
RP1000-8-07-P70-GX49 Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P10-P70 (brass)
RP1000-8-07-P70-GY49 Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P10-P94 (stainless)
RP2000-8-08-P70 Port size: Rc1/4 | Exhaust port: Rc3/8 | Set pressure range (MPa): 0.03-0.85 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.2% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 5 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 470 | Clean spec: P70 (exhaust treatment)
RP2000-10-08-P70 Port size: Rc3/8 | Exhaust port: Rc3/8 | Set pressure range (MPa): 0.03-0.85 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.2% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 5 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 470 | Clean spec: P70 (exhaust treatment)
RegulatorsCKD
11 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

CKD Precision Regulator RP1000/RP2000 Series (Clean Spec P70)

Brand CKD·Regulators

Available part numbers (11)

RP1000-8-02-P70, RP1000-8-02-P70-GX49, RP1000-8-02-P70-GY49, RP1000-8-04-P70, RP1000-8-04-P70-GX49, RP1000-8-04-P70-GY49, RP1000-8-07-P70, RP1000-8-07-P70-GX49, RP1000-8-07-P70-GY49, RP2000-8-08-P70 + 1 more — see full table ↓

How to order

Send the CKD part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
RP1000-8-02-P70Port size: Rc1/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 1.3 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)
RP1000-8-02-P70-GX49Port size: Rc1/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 1.3 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P02-P70 (brass)
RP1000-8-02-P70-GY49Port size: Rc1/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 1.3 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P02-P94 (stainless)
RP1000-8-04-P70Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)
RP1000-8-04-P70-GX49Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P04-P70 (brass)
RP1000-8-04-P70-GY49Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P04-P94 (stainless)
RP1000-8-07-P70Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)
RP1000-8-07-P70-GX49Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P10-P70 (brass)
RP1000-8-07-P70-GY49Port size: Rc1/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 3.4 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P10-P94 (stainless)
RP2000-8-08-P70Port size: Rc1/4 | Exhaust port: Rc3/8 | Set pressure range (MPa): 0.03-0.85 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.2% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 5 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 470 | Clean spec: P70 (exhaust treatment)
RP2000-10-08-P70Port size: Rc3/8 | Exhaust port: Rc3/8 | Set pressure range (MPa): 0.03-0.85 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.2% of full span | Repeatability: within +/-0.5% of full span | Air consumption (L/min ANR): 5 or less | Gauge port: Rc1/8 | Ambient/fluid temp (C): -5 to 50 | Mass (g): 470 | Clean spec: P70 (exhaust treatment)

Need a different model, or a part not listed here? Send us your parts list →