LS Electric Smart LV Solution Digital Accessories (HMI, M LINK, IPM)

LS Electric Smart LV Solution Digital Accessories (HMI, M LINK, IPM)

LS Electric Smart LV Solution digital accessories that power, connect, display, test and extend Susol Smart MCCBs and Susol/Metasol ACB STU trip units in low-voltage panels.

Key features

  • IHM8 3.5-inch and IHM32 7.0-inch panel HMIs for breaker status, metering and on/off control
  • ILM M LINK I/O module (6 DI / 4 DO / 4-20 mA AI) and TRIO temperature/I-O module with Modbus RTU over RS485
  • ITCM T-connection module and EXIO 0.35/1.3/3 m cables for RS485 multi-drop and 24 V distribution
  • IPM DC power modules (12-36 W, 24 VDC output) for AC 100-415 V or DC 24-125 V supplies
  • IPOT i-Tester and IPBM portable battery & trip module for commissioning and trip testing
  • IWM-ET-F24 E COLLECTOR gathers wireless E TAG energy data for RS485/Ethernet systems

Specifications

Applicable breakers Susol Smart MCCB, Susol/Metasol ACB STU, TS1600
Supply (modules) DC 24 V
Protocol Modbus RTU / Modbus TCP
Mounting (modules) DIN rail or screw
Operating temperature -25 to +60 C (HMI: 0 to +50 C / -20 to +60 C)
Humidity 85% RH or less, non-condensing
Source LS Electric Smart LV Solution catalog C800R1-06 (2026-04), p. 36, 68, 78-85, 98-100
IHM8 Device: Panel HMI 3.5 inch | Function: Display for up to 8 breakers | Power / consumption: DC 24 V, 3.0 W max | Interface: RS485 Modbus | Size (WxHxD): -
IHM32 Device: Panel HMI 7.0 inch | Function: Touch display for up to 32 devices | Power / consumption: DC 24 V, 23.0 W max | Interface: Ethernet | Size (WxHxD): -
ILM-DC24V-DI6/DO4 Device: M LINK I/O module | Function: 6 DI / 4 DO / 1 AI (4-20 mA) | Power / consumption: DC 24 V, 1.3 W max | Interface: RS485 Modbus RTU | Size (WxHxD): 54 x 81 x 65 mm
TRIO Device: TRIO temperature & I/O module | Function: 4 temp. sensors, 6 DI / 5 DO | Power / consumption: DC 24 V, 6 W max | Interface: RS485 Modbus RTU | Size (WxHxD): 72 x 81 x 65 mm
ITCM Device: T Connection Module | Function: RS485 multi-drop branch / terminator | Power / consumption: DC 24 V | Interface: RS485 + 24 V bus | Size (WxHxD): 17.8 x 81 x 65.6 mm
EXIOL350 Device: Communication / power cable | Function: Smart MCCB cable, 0.35 m | Power / consumption: - | Interface: RS485 + 24 V bus | Size (WxHxD): -
EXIOL1300 Device: Communication / power cable | Function: Smart MCCB cable, 1.3 m | Power / consumption: - | Interface: RS485 + 24 V bus | Size (WxHxD): -
EXIOL3000 Device: Communication / power cable | Function: Smart MCCB cable, 3 m | Power / consumption: - | Interface: RS485 + 24 V bus | Size (WxHxD): -
IWM-ET-F24 Device: E COLLECTOR wireless collector | Function: Collects data from up to 40 E TAGs | Power / consumption: AC 110/220 V, 5 W max | Interface: RS485, Ethernet, 2.4 GHz RF | Size (WxHxD): 72 x 81 x 65 mm
IPOT Device: i-Tester (portable OCR tester) | Function: Relay test, calibration, settings | Power / consumption: DC 24 V adapter or 3 x 9 V | Interface: Test port, USB 2.0 | Size (WxHxD): 98 x 210.5 x 43.5 mm
IPBM Device: Portable Battery & Trip Module | Function: Powers Smart MCCB, trip test | Power / consumption: 2 x AA battery | Interface: Test port | Size (WxHxD): 72 x 135 x 34.5 mm
IPM3P-AC240V/DC24V12W Device: DC Power Module 12 W | Function: In 100-240 VAC, out 24 VDC 0.5 A | Power / consumption: AC 100-240 V input | Interface: DIN rail / screw | Size (WxHxD): 54 x 81 x 65 mm
IPM6P-DC30V/DC24V24W Device: DC Power Module 24 W | Function: In 24-30 VDC, out 24 VDC 1 A | Power / consumption: DC 24-30 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
IPM6P-DC125V/DC24V24W Device: DC Power Module 24 W | Function: In 48-125 VDC, out 24 VDC 1 A | Power / consumption: DC 48-125 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
IPM6P-AC415V/DC24V24W Device: DC Power Module 24 W | Function: In 380-415 VAC, out 24 VDC 1 A | Power / consumption: AC 380-415 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
IPM6P-ACDC240V/DC24V36W Device: DC Power Module 36 W | Function: In AC/DC 100-240 V, out 24 VDC 1.5 A | Power / consumption: AC/DC 100-240 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
AccessoriesLS Electric
16 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric Smart LV Solution Digital Accessories (HMI, M LINK, IPM)

Brand LS Electric·Accessories

Available part numbers (16)

IHM8, IHM32, ILM-DC24V-DI6/DO4, TRIO, ITCM, EXIOL350, EXIOL1300, EXIOL3000, IWM-ET-F24, IPOT + 6 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
IHM8Device: Panel HMI 3.5 inch | Function: Display for up to 8 breakers | Power / consumption: DC 24 V, 3.0 W max | Interface: RS485 Modbus | Size (WxHxD): -
IHM32Device: Panel HMI 7.0 inch | Function: Touch display for up to 32 devices | Power / consumption: DC 24 V, 23.0 W max | Interface: Ethernet | Size (WxHxD): -
ILM-DC24V-DI6/DO4Device: M LINK I/O module | Function: 6 DI / 4 DO / 1 AI (4-20 mA) | Power / consumption: DC 24 V, 1.3 W max | Interface: RS485 Modbus RTU | Size (WxHxD): 54 x 81 x 65 mm
TRIODevice: TRIO temperature & I/O module | Function: 4 temp. sensors, 6 DI / 5 DO | Power / consumption: DC 24 V, 6 W max | Interface: RS485 Modbus RTU | Size (WxHxD): 72 x 81 x 65 mm
ITCMDevice: T Connection Module | Function: RS485 multi-drop branch / terminator | Power / consumption: DC 24 V | Interface: RS485 + 24 V bus | Size (WxHxD): 17.8 x 81 x 65.6 mm
EXIOL350Device: Communication / power cable | Function: Smart MCCB cable, 0.35 m | Power / consumption: - | Interface: RS485 + 24 V bus | Size (WxHxD): -
EXIOL1300Device: Communication / power cable | Function: Smart MCCB cable, 1.3 m | Power / consumption: - | Interface: RS485 + 24 V bus | Size (WxHxD): -
EXIOL3000Device: Communication / power cable | Function: Smart MCCB cable, 3 m | Power / consumption: - | Interface: RS485 + 24 V bus | Size (WxHxD): -
IWM-ET-F24Device: E COLLECTOR wireless collector | Function: Collects data from up to 40 E TAGs | Power / consumption: AC 110/220 V, 5 W max | Interface: RS485, Ethernet, 2.4 GHz RF | Size (WxHxD): 72 x 81 x 65 mm
IPOTDevice: i-Tester (portable OCR tester) | Function: Relay test, calibration, settings | Power / consumption: DC 24 V adapter or 3 x 9 V | Interface: Test port, USB 2.0 | Size (WxHxD): 98 x 210.5 x 43.5 mm
IPBMDevice: Portable Battery & Trip Module | Function: Powers Smart MCCB, trip test | Power / consumption: 2 x AA battery | Interface: Test port | Size (WxHxD): 72 x 135 x 34.5 mm
IPM3P-AC240V/DC24V12WDevice: DC Power Module 12 W | Function: In 100-240 VAC, out 24 VDC 0.5 A | Power / consumption: AC 100-240 V input | Interface: DIN rail / screw | Size (WxHxD): 54 x 81 x 65 mm
IPM6P-DC30V/DC24V24WDevice: DC Power Module 24 W | Function: In 24-30 VDC, out 24 VDC 1 A | Power / consumption: DC 24-30 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
IPM6P-DC125V/DC24V24WDevice: DC Power Module 24 W | Function: In 48-125 VDC, out 24 VDC 1 A | Power / consumption: DC 48-125 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
IPM6P-AC415V/DC24V24WDevice: DC Power Module 24 W | Function: In 380-415 VAC, out 24 VDC 1 A | Power / consumption: AC 380-415 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm
IPM6P-ACDC240V/DC24V36WDevice: DC Power Module 36 W | Function: In AC/DC 100-240 V, out 24 VDC 1.5 A | Power / consumption: AC/DC 100-240 V input | Interface: DIN rail / screw | Size (WxHxD): 108 x 81 x 65 mm

Need a different model, or a part not listed here? Send us your parts list →