The Mitsubishi Electric MSO-T80DL is an MS-T/N series delay-open magnetic starter that keeps the motor circuit closed through momentary power failures.

Key features

  • Holds the contactor closed for 2 (+2/-1) s during momentary power failures or voltage dips
  • Capacitor-backed coil circuit - no re-closing operation needed after the dip, load keeps running
  • For lighting, building automation and other circuits that must ride through brief outages
  • Rated AC-3 capacity 19 / 37 / 45 kW at 220/440/550V; heaters 15A-67A
  • Operation coil AC100V (100-110V) or AC200V (200-220V); main-circuit rated voltage must be specified at order

Specifications

Series MS-T/N
Frame T80
Construction Open type
Rated capacity AC-3 (200/400/500V) 19/37/45 kW
Rated current AC-3 (220/440/550V) 80/80/75 A
Delay time 2 (+2/-1) s fixed
Auxiliary contacts 1a1b
Model MSO-T80DL
Source Mitsubishi Electric MS-T/N Series catalogue (Korea ed.), p. 110-111, 124, 127
MSO-T80DL 15A AC100V Heater: 15A | Setting range: 12-18A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 15A AC200V Heater: 15A | Setting range: 12-18A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 22A AC100V Heater: 22A | Setting range: 18-26A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 22A AC200V Heater: 22A | Setting range: 18-26A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 29A AC100V Heater: 29A | Setting range: 24-34A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 29A AC200V Heater: 29A | Setting range: 24-34A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 35A AC100V Heater: 35A | Setting range: 30-40A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 35A AC200V Heater: 35A | Setting range: 30-40A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 42A AC100V Heater: 42A | Setting range: 34-50A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 42A AC200V Heater: 42A | Setting range: 34-50A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 54A AC100V Heater: 54A | Setting range: 43-65A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 54A AC200V Heater: 54A | Setting range: 43-65A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 67A AC100V Heater: 67A | Setting range: 54-80A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T100
MSO-T80DL 67A AC200V Heater: 67A | Setting range: 54-80A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T100
Magnetic StartersMitsubishi Electric
14 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric MSO-T80DL Delay-Open Magnetic Starter (15-67A)

Brand Mitsubishi Electric·Magnetic Starters

Available part numbers (14)

MSO-T80DL 15A AC100V, MSO-T80DL 15A AC200V, MSO-T80DL 22A AC100V, MSO-T80DL 22A AC200V, MSO-T80DL 29A AC100V, MSO-T80DL 29A AC200V, MSO-T80DL 35A AC100V, MSO-T80DL 35A AC200V, MSO-T80DL 42A AC100V, MSO-T80DL 42A AC200V + 4 more — see full table ↓

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
MSO-T80DL 15A AC100VHeater: 15A | Setting range: 12-18A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 15A AC200VHeater: 15A | Setting range: 12-18A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 22A AC100VHeater: 22A | Setting range: 18-26A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 22A AC200VHeater: 22A | Setting range: 18-26A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 29A AC100VHeater: 29A | Setting range: 24-34A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 29A AC200VHeater: 29A | Setting range: 24-34A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 35A AC100VHeater: 35A | Setting range: 30-40A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 35A AC200VHeater: 35A | Setting range: 30-40A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 42A AC100VHeater: 42A | Setting range: 34-50A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 42A AC200VHeater: 42A | Setting range: 34-50A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 54A AC100VHeater: 54A | Setting range: 43-65A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 54A AC200VHeater: 54A | Setting range: 43-65A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T65
MSO-T80DL 67A AC100VHeater: 67A | Setting range: 54-80A | Coil: AC100V | Coil rating: 100-110V 50/60Hz | Thermal relay: TH-T100
MSO-T80DL 67A AC200VHeater: 67A | Setting range: 54-80A | Coil: AC200V | Coil rating: 200-220V 50/60Hz | Thermal relay: TH-T100

Need a different model, or a part not listed here? Send us your parts list →