Skip to product information
1 of 1

Mitsubishi Electric MSOL(D)-T65 Mechanically Latched Magnetic Starter

Mitsubishi Electric MSOL(D)-T65 Mechanically Latched Magnetic Starter

The Mitsubishi Electric MSOL-T65 / MSOLD-T65 is an MS-T/N series mechanically latched magnetic starter whose contacts stay closed during power failures.

Key features

  • Mechanical latch keeps the main contacts closed through power failures and voltage dips
  • Separate closing (MC) and trip (MT) coils; momentary-excitation design, no holding power or hum
  • MSOL = AC closing coil (AC100-500V); MSOLD = DC closing coil (DC12-200V)
  • Rated AC-3 capacity 15 / 30 / 30 kW at 220/440/550V; heaters 15A-54A
  • Capacitor trip unit CTU-A/B available; manual operation possible

Specifications

Series MS-T/N
Frame T65
Construction Open type, mechanically latched
Rated capacity AC-3 (200/400/500V) 15/30/30 kW
Rated current AC-3 (220/440/550V) 65/65/45 A
Conventional thermal current Ith 100 A
Self-demagnetizing contact 1a1b (built-in)
Thermal relay TH-T65
Source Mitsubishi Electric MS-T/N Series catalogue (Korea ed.), p. 100-101, 42, 124, 126
MSOL-T65 15A MC-AC100V MT-AC100V Model: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 15A MC-AC200V MT-AC200V Model: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 15A MC-AC300V MT-AC300V Model: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 15A MC-AC400V MT-AC400V Model: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 15A MC-AC500V MT-AC500V Model: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 22A MC-AC100V MT-AC100V Model: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 22A MC-AC200V MT-AC200V Model: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 22A MC-AC300V MT-AC300V Model: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 22A MC-AC400V MT-AC400V Model: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 22A MC-AC500V MT-AC500V Model: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 29A MC-AC100V MT-AC100V Model: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 29A MC-AC200V MT-AC200V Model: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 29A MC-AC300V MT-AC300V Model: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 29A MC-AC400V MT-AC400V Model: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 29A MC-AC500V MT-AC500V Model: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 35A MC-AC100V MT-AC100V Model: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 35A MC-AC200V MT-AC200V Model: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 35A MC-AC300V MT-AC300V Model: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 35A MC-AC400V MT-AC400V Model: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 35A MC-AC500V MT-AC500V Model: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 42A MC-AC100V MT-AC100V Model: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 42A MC-AC200V MT-AC200V Model: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 42A MC-AC300V MT-AC300V Model: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 42A MC-AC400V MT-AC400V Model: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 42A MC-AC500V MT-AC500V Model: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 54A MC-AC100V MT-AC100V Model: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 54A MC-AC200V MT-AC200V Model: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 54A MC-AC300V MT-AC300V Model: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 54A MC-AC400V MT-AC400V Model: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 54A MC-AC500V MT-AC500V Model: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOLD-T65 15A MC-DC12V MT-DC12V Model: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 15A MC-DC24V MT-DC24V Model: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 15A MC-DC48V MT-DC48V Model: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 15A MC-DC100V MT-DC100V Model: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 15A MC-DC125V MT-DC125V Model: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 15A MC-DC200V MT-DC200V Model: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 22A MC-DC12V MT-DC12V Model: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 22A MC-DC24V MT-DC24V Model: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 22A MC-DC48V MT-DC48V Model: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 22A MC-DC100V MT-DC100V Model: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 22A MC-DC125V MT-DC125V Model: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 22A MC-DC200V MT-DC200V Model: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 29A MC-DC12V MT-DC12V Model: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 29A MC-DC24V MT-DC24V Model: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 29A MC-DC48V MT-DC48V Model: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 29A MC-DC100V MT-DC100V Model: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 29A MC-DC125V MT-DC125V Model: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 29A MC-DC200V MT-DC200V Model: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 35A MC-DC12V MT-DC12V Model: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 35A MC-DC24V MT-DC24V Model: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 35A MC-DC48V MT-DC48V Model: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 35A MC-DC100V MT-DC100V Model: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 35A MC-DC125V MT-DC125V Model: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 35A MC-DC200V MT-DC200V Model: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 42A MC-DC12V MT-DC12V Model: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 42A MC-DC24V MT-DC24V Model: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 42A MC-DC48V MT-DC48V Model: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 42A MC-DC100V MT-DC100V Model: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 42A MC-DC125V MT-DC125V Model: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 42A MC-DC200V MT-DC200V Model: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 54A MC-DC12V MT-DC12V Model: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 54A MC-DC24V MT-DC24V Model: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 54A MC-DC48V MT-DC48V Model: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 54A MC-DC100V MT-DC100V Model: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 54A MC-DC125V MT-DC125V Model: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 54A MC-DC200V MT-DC200V Model: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
Magnetic StartersMitsubishi Electric
66 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric MSOL(D)-T65 Mechanically Latched Magnetic Starter

Brand Mitsubishi Electric·Magnetic Starters

Available part numbers (66)

MSOL-T65 15A MC-AC100V MT-AC100V, MSOL-T65 15A MC-AC200V MT-AC200V, MSOL-T65 15A MC-AC300V MT-AC300V, MSOL-T65 15A MC-AC400V MT-AC400V, MSOL-T65 15A MC-AC500V MT-AC500V, MSOL-T65 22A MC-AC100V MT-AC100V, MSOL-T65 22A MC-AC200V MT-AC200V, MSOL-T65 22A MC-AC300V MT-AC300V, MSOL-T65 22A MC-AC400V MT-AC400V, MSOL-T65 22A MC-AC500V MT-AC500V + 56 more — see full table ↓

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
MSOL-T65 15A MC-AC100V MT-AC100VModel: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 15A MC-AC200V MT-AC200VModel: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 15A MC-AC300V MT-AC300VModel: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 15A MC-AC400V MT-AC400VModel: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 15A MC-AC500V MT-AC500VModel: MSOL-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 22A MC-AC100V MT-AC100VModel: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 22A MC-AC200V MT-AC200VModel: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 22A MC-AC300V MT-AC300VModel: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 22A MC-AC400V MT-AC400VModel: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 22A MC-AC500V MT-AC500VModel: MSOL-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 29A MC-AC100V MT-AC100VModel: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 29A MC-AC200V MT-AC200VModel: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 29A MC-AC300V MT-AC300VModel: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 29A MC-AC400V MT-AC400VModel: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 29A MC-AC500V MT-AC500VModel: MSOL-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 35A MC-AC100V MT-AC100VModel: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 35A MC-AC200V MT-AC200VModel: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 35A MC-AC300V MT-AC300VModel: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 35A MC-AC400V MT-AC400VModel: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 35A MC-AC500V MT-AC500VModel: MSOL-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 42A MC-AC100V MT-AC100VModel: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 42A MC-AC200V MT-AC200VModel: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 42A MC-AC300V MT-AC300VModel: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 42A MC-AC400V MT-AC400VModel: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 42A MC-AC500V MT-AC500VModel: MSOL-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOL-T65 54A MC-AC100V MT-AC100VModel: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC100V MT-AC100V | Coil rating: 100-127V
MSOL-T65 54A MC-AC200V MT-AC200VModel: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC200V MT-AC200V | Coil rating: 200-240V
MSOL-T65 54A MC-AC300V MT-AC300VModel: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC300V MT-AC300V | Coil rating: 260-350V
MSOL-T65 54A MC-AC400V MT-AC400VModel: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC400V MT-AC400V | Coil rating: 380-440V
MSOL-T65 54A MC-AC500V MT-AC500VModel: MSOL-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-AC500V MT-AC500V | Coil rating: 460-550V
MSOLD-T65 15A MC-DC12V MT-DC12VModel: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 15A MC-DC24V MT-DC24VModel: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 15A MC-DC48V MT-DC48VModel: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 15A MC-DC100V MT-DC100VModel: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 15A MC-DC125V MT-DC125VModel: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 15A MC-DC200V MT-DC200VModel: MSOLD-T65 | Heater: 15A | Setting range: 12-18A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 22A MC-DC12V MT-DC12VModel: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 22A MC-DC24V MT-DC24VModel: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 22A MC-DC48V MT-DC48VModel: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 22A MC-DC100V MT-DC100VModel: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 22A MC-DC125V MT-DC125VModel: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 22A MC-DC200V MT-DC200VModel: MSOLD-T65 | Heater: 22A | Setting range: 18-26A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 29A MC-DC12V MT-DC12VModel: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 29A MC-DC24V MT-DC24VModel: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 29A MC-DC48V MT-DC48VModel: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 29A MC-DC100V MT-DC100VModel: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 29A MC-DC125V MT-DC125VModel: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 29A MC-DC200V MT-DC200VModel: MSOLD-T65 | Heater: 29A | Setting range: 24-34A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 35A MC-DC12V MT-DC12VModel: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 35A MC-DC24V MT-DC24VModel: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 35A MC-DC48V MT-DC48VModel: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 35A MC-DC100V MT-DC100VModel: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 35A MC-DC125V MT-DC125VModel: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 35A MC-DC200V MT-DC200VModel: MSOLD-T65 | Heater: 35A | Setting range: 30-40A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 42A MC-DC12V MT-DC12VModel: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 42A MC-DC24V MT-DC24VModel: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 42A MC-DC48V MT-DC48VModel: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 42A MC-DC100V MT-DC100VModel: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 42A MC-DC125V MT-DC125VModel: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 42A MC-DC200V MT-DC200VModel: MSOLD-T65 | Heater: 42A | Setting range: 34-50A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V
MSOLD-T65 54A MC-DC12V MT-DC12VModel: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC12V MT-DC12V | Coil rating: DC12V
MSOLD-T65 54A MC-DC24V MT-DC24VModel: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC24V MT-DC24V | Coil rating: DC24V
MSOLD-T65 54A MC-DC48V MT-DC48VModel: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC48V MT-DC48V | Coil rating: DC48V
MSOLD-T65 54A MC-DC100V MT-DC100VModel: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC100V MT-DC100V | Coil rating: DC100-110V
MSOLD-T65 54A MC-DC125V MT-DC125VModel: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC125V MT-DC125V | Coil rating: DC120-125V
MSOLD-T65 54A MC-DC200V MT-DC200VModel: MSOLD-T65 | Heater: 54A | Setting range: 43-65A | Closing/trip coil: MC-DC200V MT-DC200V | Coil rating: DC200-220V

Need a different model, or a part not listed here? Send us your parts list →