Skip to product information
1 of 1

Omron 61F-G[] Floatless Level Switch Controller (Basic, G/G1/G2/G3/G4/I, General/Long-dist/High/Low/2W/Tropical)

Omron 61F-G[] Floatless Level Switch Controller (Basic, G/G1/G2/G3/G4/I, General/Long-dist/High/Low/2W/Tropical)

Basic Building-block Controllers That Mount Directly to Panels for Easier Maintenance.

Specifications

Type Floatless Level Switch Controller (Basic)
61F-G 61F-G General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: General-purpose | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1 61F-G1 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: General-purpose | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2 61F-G2 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: General-purpose | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3 61F-G3 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: General-purpose | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4 61F-G4 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: General-purpose | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-I 61F-I General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: General-purpose | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-GL 2KM 61F-G Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Long-distance 2KM | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering; 2 km
61F-G1L 2KM 61F-G1 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Long-distance 2KM | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 2 km
61F-G2L 2KM 61F-G2 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Long-distance 2KM | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 2 km
61F-G3L 2KM 61F-G3 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Long-distance 2KM | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering; 2 km
61F-G4L 2KM 61F-G4 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Long-distance 2KM | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering; 2 km
61F-IL 2KM 61F-I Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Long-distance 2KM | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 2 km
61F-GL 4KM 61F-G Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Long-distance 4KM | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering; 4 km
61F-G1L 4KM 61F-G1 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Long-distance 4KM | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 4 km
61F-G2L 4KM 61F-G2 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Long-distance 4KM | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 4 km
61F-G3L 4KM 61F-G3 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Long-distance 4KM | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering; 4 km
61F-G4L 4KM 61F-G4 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Long-distance 4KM | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering; 4 km
61F-IL 4KM 61F-I Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Long-distance 4KM | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 4 km
61F-GH 61F-G High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: High-sensitivity | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1H 61F-G1 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: High-sensitivity | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2H 61F-G2 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: High-sensitivity | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3H 61F-G3 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: High-sensitivity | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4H 61F-G4 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: High-sensitivity | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-GD 61F-G Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Low-sensitivity | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1D 61F-G1 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Low-sensitivity | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2D 61F-G2 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Low-sensitivity | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3D 61F-G3 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Low-sensitivity | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4D 61F-G4 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Low-sensitivity | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-ID 61F-I Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Low-sensitivity | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-GR 61F-G Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Two-wire | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1R 61F-G1 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Two-wire | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2R 61F-G2 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Two-wire | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3R 61F-G3 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Two-wire | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4R 61F-G4 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Two-wire | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-G-TDL 61F-G Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Tropical environments | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1-TDL 61F-G1 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Tropical environments | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2-TDL 61F-G2 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Tropical environments | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3-TDL 61F-G3 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Tropical environments | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4-TDL 61F-G4 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Tropical environments | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-I-TDL 61F-I Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Tropical environments | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
Level SwitchesOmron
40 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Omron 61F-G[] Floatless Level Switch Controller (Basic, G/G1/G2/G3/G4/I, General/Long-dist/High/Low/2W/Tropical)

Brand Omron·Level Switches

Available part numbers (40)

61F-G, 61F-G1, 61F-G2, 61F-G3, 61F-G4, 61F-I, 61F-GL 2KM, 61F-G1L 2KM, 61F-G2L 2KM, 61F-G3L 2KM + 30 more — see full table ↓

How to order

Send the Omron part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
61F-G61F-G General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: General-purpose | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G161F-G1 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: General-purpose | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G261F-G2 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: General-purpose | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G361F-G3 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: General-purpose | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G461F-G4 General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: General-purpose | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-I61F-I General-purpose | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: General-purpose | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-GL 2KM61F-G Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Long-distance 2KM | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering; 2 km
61F-G1L 2KM61F-G1 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Long-distance 2KM | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 2 km
61F-G2L 2KM61F-G2 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Long-distance 2KM | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 2 km
61F-G3L 2KM61F-G3 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Long-distance 2KM | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering; 2 km
61F-G4L 2KM61F-G4 Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Long-distance 2KM | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering; 2 km
61F-IL 2KM61F-I Long-distance 2KM | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Long-distance 2KM | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 2 km
61F-GL 4KM61F-G Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Long-distance 4KM | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering; 4 km
61F-G1L 4KM61F-G1 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Long-distance 4KM | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 4 km
61F-G2L 4KM61F-G2 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Long-distance 4KM | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 4 km
61F-G3L 4KM61F-G3 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Long-distance 4KM | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering; 4 km
61F-G4L 4KM61F-G4 Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Long-distance 4KM | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering; 4 km
61F-IL 4KM61F-I Long-distance 4KM | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Long-distance 4KM | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering; 4 km
61F-GH61F-G High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: High-sensitivity | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1H61F-G1 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: High-sensitivity | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2H61F-G2 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: High-sensitivity | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3H61F-G3 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: High-sensitivity | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4H61F-G4 High-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: High-sensitivity | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-GD61F-G Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Low-sensitivity | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1D61F-G1 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Low-sensitivity | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2D61F-G2 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Low-sensitivity | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3D61F-G3 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Low-sensitivity | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4D61F-G4 Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Low-sensitivity | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-ID61F-I Low-sensitivity | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Low-sensitivity | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-GR61F-G Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Two-wire | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1R61F-G1 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Two-wire | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2R61F-G2 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Two-wire | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3R61F-G3 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Two-wire | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4R61F-G4 Two-wire | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Two-wire | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-G-TDL61F-G Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G | Function: Automatic water supply and drainage control | Sensitivity: Tropical environments | Set Contents: 61F-G Base × 1 + 61F-11[] Unit × 1 | Note: Specify operating voltage when ordering
61F-G1-TDL61F-G1 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G1 | Function: Automatic water supply control w/pump idling prevention | Sensitivity: Tropical environments | Set Contents: 61F-G1 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G2-TDL61F-G2 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G2 | Function: Automatic water supply and drainage control w/alarm high level | Sensitivity: Tropical environments | Set Contents: 61F-G2 Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering
61F-G3-TDL61F-G3 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G3 | Function: Automatic water supply and drainage control w/alarm high+low | Sensitivity: Tropical environments | Set Contents: 61F-G3 Base × 1 + 61F-11[] Unit × 3 | Note: Specify operating voltage when ordering
61F-G4-TDL61F-G4 Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application G4 | Function: Automatic water supply control w/level display | Sensitivity: Tropical environments | Set Contents: 61F-G4 Base × 1 + 61F-11[] Unit × 5 + MK3P Relay × 1 | Note: Specify operating voltage when ordering
61F-I-TDL61F-I Tropical environments | Type: Floatless Level Switch Controller (Basic) | Application: Application I | Function: Level indication with alarm | Sensitivity: Tropical environments | Set Contents: 61F-I Base × 1 + 61F-11[] Unit × 2 | Note: Specify operating voltage when ordering

Need a different model, or a part not listed here? Send us your parts list →