Skip to product information
1 of 1

Omron K8AK-AW Single-phase Overcurrent/Undercurrent Relay (Simultaneous, 2mA~200A AC/DC)

Omron K8AK-AW Single-phase Overcurrent/Undercurrent Relay (Simultaneous, 2mA~200A AC/DC)

OMRON K8AK-AW Series single-phase relay for simultaneous overcurrent and undercurrent monitoring.

Key features

  • K8AK-AW1: 2mA~500mA
  • K8AK-AW2: 0.1A~5A
  • K8AK-AW3: 10~200A AC (requires K8AC-CT200L CT)
  • Power supply: 24 VAC/DC or 100~240 VAC
  • Relay output
K8AK-AW1 24 VAC/DC K8AK-AW AW1 24 VAC/DC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring
K8AK-AW1 100-240 VAC K8AK-AW AW1 100~240 VAC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring
K8AK-AW2 24 VAC/DC K8AK-AW AW2 24 VAC/DC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible
K8AK-AW2 100-240 VAC K8AK-AW AW2 100~240 VAC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT compatible
K8AK-AW3 24 VAC/DC K8AK-AW AW3 24 VAC/DC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family)
K8AK-AW3 100-240 VAC K8AK-AW AW3 100~240 VAC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family)
K8AC-CT200L Current Transformer for K8AK-AW3 10~200A | Type: Current Transformer (CT) | Input Range: 10~100A AC / 20~200A AC | Compatible Relay: K8AK-AW3 (required, direct input not possible)
Monitoring RelaysOmron
7 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Omron K8AK-AW Single-phase Overcurrent/Undercurrent Relay (Simultaneous, 2mA~200A AC/DC)

Brand Omron·Monitoring Relays

Available part numbers (7)

K8AK-AW1 24 VAC/DC, K8AK-AW1 100-240 VAC, K8AK-AW2 24 VAC/DC, K8AK-AW2 100-240 VAC, K8AK-AW3 24 VAC/DC, K8AK-AW3 100-240 VAC, K8AC-CT200L

How to order

Send the Omron part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
K8AK-AW1 24 VAC/DCK8AK-AW AW1 24 VAC/DC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring
K8AK-AW1 100-240 VACK8AK-AW AW1 100~240 VAC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring
K8AK-AW2 24 VAC/DCK8AK-AW AW2 24 VAC/DC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible
K8AK-AW2 100-240 VACK8AK-AW AW2 100~240 VAC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT compatible
K8AK-AW3 24 VAC/DCK8AK-AW AW3 24 VAC/DC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family)
K8AK-AW3 100-240 VACK8AK-AW AW3 100~240 VAC | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family)
K8AC-CT200LCurrent Transformer for K8AK-AW3 10~200A | Type: Current Transformer (CT) | Input Range: 10~100A AC / 20~200A AC | Compatible Relay: K8AK-AW3 (required, direct input not possible)