Skip to product information
1 of 1

Siemens SENTRON 3LD2 Switches in Molded-Plastic Enclosure (16–125 A)

Siemens SENTRON 3LD2 Switches in Molded-Plastic Enclosure (16–125 A)

Siemens SENTRON 3LD2 main control, EMERGENCY-STOP, maintenance/repair (EMC shield plate) switches and 800 V DC isolators in molded-plastic enclosure.

Key features

  • Uninterrupted current Iu 16 … 125 A at AC-21A, 380 … 440 V; 25 … 50 kArms
  • 3-pole, 3-pole + N and 6-pole versions with PE, N or PE+N base terminals
  • Rotary operating mechanism with masking plate, black or red/yellow
  • Maintenance and repair switches with EMC shield plate and front-mounted 1 NO + 1 NC
  • 8-pole DC isolators for 800 V DC, 32 A (DC-21A)

Specifications

Brand Siemens SENTRON
Series 3LD2
Enclosure Molded-plastic
Catalog chapter 8 Switch Disconnectors
Product group Fuseless switch disconnectors
Standard IEC 60947-3
Short-circuit rating 25 … 50 kArms
Source Siemens Catalog LV 10 · 2026, p. 672-678
3LD2064-0TB51 Version: Main control switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2064-1GP51 Version: Main control switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2064-1TC51 Version: Main control switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2164-0TB51 Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2164-1GP51 Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2164-1TC51 Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2165-3VB51 Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2165-4VD51 Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2264-0TB51 Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2264-1GP51 Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2264-1TC51 Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2265-3VB51 Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2265-4VD51 Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2565-0TB51 Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2565-1GP51 Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2565-1TC51 Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2566-3VB51 Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2566-4VD51 Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: PE+N | Handle: Black (main control)
3LD2766-0TB51 Version: Main control switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2766-1GP51 Version: Main control switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2866-0TB51 Version: Main control switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2866-1GP51 Version: Main control switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2064-0TB53 Version: EMERGENCY-STOP switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2064-1GP53 Version: EMERGENCY-STOP switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2064-1TC53 Version: EMERGENCY-STOP switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2164-0TB53 Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2164-1GP53 Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2164-1TC53 Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2165-3VB53 Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2165-4VD53 Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2264-0TB53 Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2264-1GP53 Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2264-1TC53 Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2265-3VB53 Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2265-4VD53 Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2565-0TB53 Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2565-1GP53 Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2565-1TC53 Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2566-3VB53 Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2566-4VD53 Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2766-0TB53 Version: EMERGENCY-STOP switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2766-1GP53 Version: EMERGENCY-STOP switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2866-0TB53 Version: EMERGENCY-STOP switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2866-1GP53 Version: EMERGENCY-STOP switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2265-8VQ51-0AF6 Version: DC isolator 800 V DC | Rated current Iu: 32 A (DC-21A, 800 V DC) | Power AC-23A/AC-3: 16 A at DC-22A, 800 V DC | Poles / aux.: 8P, aux. None | Base terminal: – | Handle: Black
3LD2265-8VQ53-0AF6 Version: DC isolator 800 V DC | Rated current Iu: 32 A (DC-21A, 800 V DC) | Power AC-23A/AC-3: 16 A at DC-22A, 800 V DC | Poles / aux.: 8P, aux. None | Base terminal: – | Handle: Red/yellow
3LD2084-2GP21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2184-2GP21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 25 A | Power AC-23A/AC-3: 9 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2185-5VD21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 25 A | Power AC-23A/AC-3: 9 kW (AC-23A) | Poles / aux.: 6P, aux. 1 NO + 1 NC (front) | Base terminal: 2 × PE | Handle: Black
3LD2284-2GP21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2285-5VD21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW (AC-23A) | Poles / aux.: 6P, aux. 1 NO + 1 NC (front) | Base terminal: 2 × PE | Handle: Black
3LD2585-2GP21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2586-5VD21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW (AC-23A) | Poles / aux.: 6P, aux. 1 NO + 1 NC (front) | Base terminal: 2 × PE | Handle: Black
3LD2786-2GP21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2886-2GP21 Version: Maintenance switch, EMC shield plate | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
Switch DisconnectorsSiemens
55 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Siemens SENTRON 3LD2 Switches in Molded-Plastic Enclosure (16–125 A)

Brand Siemens·Switch Disconnectors

Available part numbers (55)

3LD2064-0TB51, 3LD2064-1GP51, 3LD2064-1TC51, 3LD2164-0TB51, 3LD2164-1GP51, 3LD2164-1TC51, 3LD2165-3VB51, 3LD2165-4VD51, 3LD2264-0TB51, 3LD2264-1GP51 + 45 more — see full table ↓

How to order

Send the Siemens part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
3LD2064-0TB51Version: Main control switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2064-1GP51Version: Main control switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2064-1TC51Version: Main control switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2164-0TB51Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2164-1GP51Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2164-1TC51Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2165-3VB51Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2165-4VD51Version: Main control switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2264-0TB51Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2264-1GP51Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2264-1TC51Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2265-3VB51Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2265-4VD51Version: Main control switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2565-0TB51Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2565-1GP51Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2565-1TC51Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Black (main control)
3LD2566-3VB51Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2566-4VD51Version: Main control switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: PE+N | Handle: Black (main control)
3LD2766-0TB51Version: Main control switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2766-1GP51Version: Main control switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2866-0TB51Version: Main control switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Black (main control)
3LD2866-1GP51Version: Main control switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Black (main control)
3LD2064-0TB53Version: EMERGENCY-STOP switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2064-1GP53Version: EMERGENCY-STOP switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2064-1TC53Version: EMERGENCY-STOP switch | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW/5.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2164-0TB53Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2164-1GP53Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2164-1TC53Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2165-3VB53Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2165-4VD53Version: EMERGENCY-STOP switch | Rated current Iu: 25 A | Power AC-23A/AC-3: 9.5 kW/7.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2264-0TB53Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2264-1GP53Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2264-1TC53Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2265-3VB53Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2265-4VD53Version: EMERGENCY-STOP switch | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW/9.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2565-0TB53Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2565-1GP53Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2565-1TC53Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 3P+N, aux. None | Base terminal: PE | Handle: Red/yellow (EMERGENCY-STOP)
3LD2566-3VB53Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2566-4VD53Version: EMERGENCY-STOP switch | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW/18.5 kW | Poles / aux.: 6P, aux. 1 NO + 1 NC | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2766-0TB53Version: EMERGENCY-STOP switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2766-1GP53Version: EMERGENCY-STOP switch | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW/30 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2866-0TB53Version: EMERGENCY-STOP switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. None | Base terminal: PE+N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2866-1GP53Version: EMERGENCY-STOP switch | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW/37 kW | Poles / aux.: 3P, aux. 1 NO + 1 NC | Base terminal: N | Handle: Red/yellow (EMERGENCY-STOP)
3LD2265-8VQ51-0AF6Version: DC isolator 800 V DC | Rated current Iu: 32 A (DC-21A, 800 V DC) | Power AC-23A/AC-3: 16 A at DC-22A, 800 V DC | Poles / aux.: 8P, aux. None | Base terminal: – | Handle: Black
3LD2265-8VQ53-0AF6Version: DC isolator 800 V DC | Rated current Iu: 32 A (DC-21A, 800 V DC) | Power AC-23A/AC-3: 16 A at DC-22A, 800 V DC | Poles / aux.: 8P, aux. None | Base terminal: – | Handle: Red/yellow
3LD2084-2GP21Version: Maintenance switch, EMC shield plate | Rated current Iu: 16 A | Power AC-23A/AC-3: 7.5 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2184-2GP21Version: Maintenance switch, EMC shield plate | Rated current Iu: 25 A | Power AC-23A/AC-3: 9 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2185-5VD21Version: Maintenance switch, EMC shield plate | Rated current Iu: 25 A | Power AC-23A/AC-3: 9 kW (AC-23A) | Poles / aux.: 6P, aux. 1 NO + 1 NC (front) | Base terminal: 2 × PE | Handle: Black
3LD2284-2GP21Version: Maintenance switch, EMC shield plate | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2285-5VD21Version: Maintenance switch, EMC shield plate | Rated current Iu: 32 A | Power AC-23A/AC-3: 11.5 kW (AC-23A) | Poles / aux.: 6P, aux. 1 NO + 1 NC (front) | Base terminal: 2 × PE | Handle: Black
3LD2585-2GP21Version: Maintenance switch, EMC shield plate | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2586-5VD21Version: Maintenance switch, EMC shield plate | Rated current Iu: 63 A | Power AC-23A/AC-3: 22 kW (AC-23A) | Poles / aux.: 6P, aux. 1 NO + 1 NC (front) | Base terminal: 2 × PE | Handle: Black
3LD2786-2GP21Version: Maintenance switch, EMC shield plate | Rated current Iu: 100 A | Power AC-23A/AC-3: 37 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black
3LD2886-2GP21Version: Maintenance switch, EMC shield plate | Rated current Iu: 125 A | Power AC-23A/AC-3: 45 kW (AC-23A) | Poles / aux.: 3P, aux. 1 NO + 1 NC (front) | Base terminal: PE | Handle: Black

Need a different model, or a part not listed here? Send us your parts list →