| Product code | Spec | ||
|---|---|---|---|
| 3NJ4103-3BF02 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 100 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4103-3BR02 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 100 mm | Connection: F70 box terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4101-3BF01 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 185 mm | Connection: M8 flat terminal | Switching: 1-pole switchable | Version: 690 V, standard | ||
| 3NJ4103-3BF01 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 185 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4121-3BF01 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 1-pole switchable | Version: 690 V, standard | ||
| 3NJ4123-3BF01 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4123-3BJ01 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M12 stud terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4123-3BT01 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: V terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4131-3BF01 | Rated current Ie: 400 A | Fuse size: NH2 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 1-pole switchable | Version: 690 V, standard | ||
| 3NJ4133-3BF01 | Rated current Ie: 400 A | Fuse size: NH2 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4133-3BJ01 | Rated current Ie: 400 A | Fuse size: NH2 | Busbar spacing: 185 mm | Connection: M12 stud terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4133-3BT01 | Rated current Ie: 400 A | Fuse size: NH2 | Busbar spacing: 185 mm | Connection: V terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4141-3BF01 | Rated current Ie: 630 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 1-pole switchable | Version: 690 V, standard | ||
| 3NJ4143-3BF01 | Rated current Ie: 630 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4143-3BJ01 | Rated current Ie: 630 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: M12 stud terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ4143-3BT01 | Rated current Ie: 630 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: V terminal | Switching: 3-pole switchable | Version: 690 V, standard | ||
| 3NJ5643-0BB00 | Rated current Ie: 1250 A | Fuse size: NH4a | Busbar spacing: 185 mm | Connection: M16 × 60 stud terminal | Switching: 1-pole switchable | Version: 690 V, NH4a | ||
| 3NJ4103-3BF12 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 100 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4121-3BF11 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 1-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4123-3BF11 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 3-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4131-3BF11 | Rated current Ie: 400 A | Fuse size: NH2 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 1-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4133-3BF11 | Rated current Ie: 400 A | Fuse size: NH2 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4141-3BF11 | Rated current Ie: 630 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 1-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4143-3BF11 | Rated current Ie: 630 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, for integratable CTs | ||
| 3NJ4103-3CF02 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 100 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 690 V, with EFM | ||
| 3NJ4123-3CF01 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 3-pole switchable | Version: 690 V, with EFM | ||
| 3NJ4133-3CF01 | Rated current Ie: 400 A | Fuse size: NH2/NH1 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, with EFM | ||
| 3NJ4143-3CF01 | Rated current Ie: 630 A | Fuse size: NH3/NH2 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, with EFM | ||
| 3NJ4103-3CF12 | Rated current Ie: 160 A | Fuse size: NH00/NH000 | Busbar spacing: 100 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 690 V, CT-ready, with EFM | ||
| 3NJ4123-3CF11 | Rated current Ie: 250 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 3-pole switchable | Version: 690 V, CT-ready, with EFM | ||
| 3NJ4133-3CF11 | Rated current Ie: 400 A | Fuse size: NH2/NH1 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, CT-ready, with EFM | ||
| 3NJ4143-3CF11 | Rated current Ie: 630 A | Fuse size: NH3/NH2 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 690 V, CT-ready, with EFM | ||
| 3NJ4153-3BF01 | Rated current Ie: 1000 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: 2 × M12 flat terminal | Switching: 3-pole switchable | Version: 400 V, transformer secondary fusing | ||
| 3NJ4183-3BF01 | Rated current Ie: 1250 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: 2 × M12 flat terminal | Switching: 3-pole switchable | Version: 400 V, transformer secondary fusing | ||
| 3NJ4163-3BF01 | Rated current Ie: 1600 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: 3 × M12 flat terminal | Switching: 3-pole switchable | Version: 400 V, transformer secondary fusing | ||
| 3NJ4173-3BF01 | Rated current Ie: 2000 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: 4 × M12 flat terminal | Switching: 3-pole switchable | Version: 400 V, transformer secondary fusing | ||
| 3NJ4103-3DF02 | Rated current Ie: 63 A | Fuse size: NH00/NH000 | Busbar spacing: 100 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 800 V | ||
| 3NJ4103-3DF01 | Rated current Ie: 63 A | Fuse size: NH00/NH000 | Busbar spacing: 185 mm | Connection: M8 flat terminal | Switching: 3-pole switchable | Version: 800 V | ||
| 3NJ4123-3DF01 | Rated current Ie: 160 A | Fuse size: NH1 | Busbar spacing: 185 mm | Connection: M10 flat terminal | Switching: 3-pole switchable | Version: 800 V | ||
| 3NJ4143-3DF01 | Rated current Ie: 315 A | Fuse size: NH3 | Busbar spacing: 185 mm | Connection: M12 flat terminal | Switching: 3-pole switchable | Version: 800 V |
Need a different model, or a part not listed here? Send us your parts list →