Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| 3RV1011-0AA10 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0BA10 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0CA10 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0DA10 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0EA10 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0FA10 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0GA10 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0HA10 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0JA10 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-0KA10 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1AA10 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1BA10 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1CA10 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1DA10 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1EA10 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1FA10 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1GA10 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Aux. switch: None | ||
| 3RV1011-1HA10 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 50 kA | Aux. switch: None | ||
| 3RV1011-1JA10 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 50 kA | Aux. switch: None | ||
| 3RV1011-1KA10 | Setting range: 9–12 A | Motor rating: 5.5 kW | Icu 400 V: 50 kA | Aux. switch: None | ||
| 3RV1011-0AA15 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0BA15 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0CA15 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0DA15 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0EA15 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0FA15 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0GA15 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0HA15 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0JA15 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-0KA15 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1AA15 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1BA15 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1CA15 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1DA15 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1EA15 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1FA15 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1GA15 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1HA15 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 50 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1JA15 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 50 kA | Aux. switch: Transverse 1 NO + 1 NC | ||
| 3RV1011-1KA15 | Setting range: 9–12 A | Motor rating: 5.5 kW | Icu 400 V: 50 kA | Aux. switch: Transverse 1 NO + 1 NC |
Need a different model, or a part not listed here? Send us your parts list →