[GGM] — K9I□40N Series 40W Three-phase AC Induction Motor (□90mm, 4-Pole, Lead Wire)

[GGM] — K9I□40N Series 40W Three-phase AC Induction Motor (□90mm, 4-Pole, Lead Wire)

Family ID: GGM-K9I40N-3P

GGM K9I□40N series 40W three-phase AC induction motor. □90mm frame, 4-pole, continuous rating, lead wire (300mm, ul style 3271 awg20). Straight (S) and pinion (G) shaft; 200–440V (50/60Hz). Pinion-shaft type combines with K9G□ gear heads (matching face/teeth). H variant (220/230V) UL certified (E204632). Note: 3-phase motors for 380V and over cannot be used with an inverter.

12 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
K9IS40NT GGM 40W three-phase AC induction motor K9IS40NT — Straight shaft, 200V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 200V | Operating Points: 200V/50Hz: 0.39A, Start 1/10N·m·kgf·cm, Rated 0.3/3N·m·kgf·cm, 1300rpm ; 200V/60Hz: 0.32A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: —
K9IG40NT GGM 40W three-phase AC induction motor K9IG40NT — Pinion (for gear head) shaft, 200V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 200V | Operating Points: 200V/50Hz: 0.39A, Start 1/10N·m·kgf·cm, Rated 0.3/3N·m·kgf·cm, 1300rpm ; 200V/60Hz: 0.32A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: —
K9IS40NH GGM 40W three-phase AC induction motor K9IS40NH — Straight shaft, 220/230V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 220/230V | Operating Points: 220V/50Hz: 0.33A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 220V/60Hz: 0.31A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm ; 230V/50Hz: 0.41A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 230V/60Hz: 0.32A, Start 0.83/8.3N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: Certified (E204632)
K9IG40NH GGM 40W three-phase AC induction motor K9IG40NH — Pinion (for gear head) shaft, 220/230V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 220/230V | Operating Points: 220V/50Hz: 0.33A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 220V/60Hz: 0.31A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm ; 230V/50Hz: 0.41A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 230V/60Hz: 0.32A, Start 0.83/8.3N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: Certified (E204632)
K9IS40NM GGM 40W three-phase AC induction motor K9IS40NM — Straight shaft, 380V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 380V | Operating Points: 380V/50Hz: 0.18A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 380V/60Hz: 0.18A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NM GGM 40W three-phase AC induction motor K9IG40NM — Pinion (for gear head) shaft, 380V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 380V | Operating Points: 380V/50Hz: 0.18A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 380V/60Hz: 0.18A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NV GGM 40W three-phase AC induction motor K9IS40NV — Straight shaft, 400V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 400V | Operating Points: 400V/50Hz: 0.18A, Start 1.15/11.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 400V/60Hz: 0.19A, Start 0.88/8.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NV GGM 40W three-phase AC induction motor K9IG40NV — Pinion (for gear head) shaft, 400V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 400V | Operating Points: 400V/50Hz: 0.18A, Start 1.15/11.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 400V/60Hz: 0.19A, Start 0.88/8.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NQ GGM 40W three-phase AC induction motor K9IS40NQ — Straight shaft, 415V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 415V | Operating Points: 415V/50Hz: 0.16A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 415V/60Hz: 0.14A, Start 0.72/7.2N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NQ GGM 40W three-phase AC induction motor K9IG40NQ — Pinion (for gear head) shaft, 415V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 415V | Operating Points: 415V/50Hz: 0.16A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 415V/60Hz: 0.14A, Start 0.72/7.2N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NZ GGM 40W three-phase AC induction motor K9IS40NZ — Straight shaft, 440V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 440V | Operating Points: 440V/50Hz: 0.19A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 440V/60Hz: 0.16A, Start 0.79/7.9N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NZ GGM 40W three-phase AC induction motor K9IG40NZ — Pinion (for gear head) shaft, 440V, Lead wire (300mm, UL Style 3271 AWG20) GGM Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 440V | Operating Points: 440V/50Hz: 0.19A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 440V/60Hz: 0.16A, Start 0.79/7.9N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)