Magnetic Starters
MITSUBISHI ELECTRIC
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xN180 Reversing Magnetic Starter (180A AC-3, N180 Frame, TH-N220RH Thermal)
Family ID: MEL-MSTR-2XN180
Mitsubishi Electric MS-T/N series N180-frame reversing open-type magnetic starter MSO-2xN180: AC-operated contactor combined with TH-N220RH 2-element thermal overload relay (manual reset standard). Rated 45kW / 180A (AC-3) at 200-220V and 90kW / 180A at 380-440V, Ith 260A. Heater designations 82A to 150A (4 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
24 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| MSO-2xN180 82A AC48V | MSO-2xN180 reversing starter, N180 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 82A AC100V | MSO-2xN180 reversing starter, N180 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 82A AC200V | MSO-2xN180 reversing starter, N180 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 82A AC300V | MSO-2xN180 reversing starter, N180 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 82A AC400V | MSO-2xN180 reversing starter, N180 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 82A AC500V | MSO-2xN180 reversing starter, N180 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 105A AC48V | MSO-2xN180 reversing starter, N180 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 105A AC100V | MSO-2xN180 reversing starter, N180 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 105A AC200V | MSO-2xN180 reversing starter, N180 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 105A AC300V | MSO-2xN180 reversing starter, N180 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 105A AC400V | MSO-2xN180 reversing starter, N180 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 105A AC500V | MSO-2xN180 reversing starter, N180 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 125A AC48V | MSO-2xN180 reversing starter, N180 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 125A AC100V | MSO-2xN180 reversing starter, N180 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 125A AC200V | MSO-2xN180 reversing starter, N180 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 125A AC300V | MSO-2xN180 reversing starter, N180 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 125A AC400V | MSO-2xN180 reversing starter, N180 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 125A AC500V | MSO-2xN180 reversing starter, N180 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 150A AC48V | MSO-2xN180 reversing starter, N180 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 150A AC100V | MSO-2xN180 reversing starter, N180 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 150A AC200V | MSO-2xN180 reversing starter, N180 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 150A AC300V | MSO-2xN180 reversing starter, N180 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 150A AC400V | MSO-2xN180 reversing starter, N180 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xN180 150A AC500V | MSO-2xN180 reversing starter, N180 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |