[OMRON] — SAO Solid-state Plug-in Current Sensor (Overcurrent/Undercurrent, 100VAC~100VDC)

[OMRON] — SAO Solid-state Plug-in Current Sensor (Overcurrent/Undercurrent, 100VAC~100VDC)

Family ID: OMRON-SAO

Solid-state, Plug-in Current Sensor

20 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
SAO-R1N SAO Overcurrent, Inverse type 100/110/120 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Inverse type | Trip Characteristic: Overcurrent inverse-time trip | Control Voltage: 100/110/120 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-Q1N SAO Overcurrent, Instantaneous (with start-up lock) 100/110/120 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Instantaneous (with start-up lock) | Trip Characteristic: Overcurrent instantaneous; fixed time-limit at start-up | Control Voltage: 100/110/120 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-S1N SAO Undercurrent, Instantaneous (with start-up lock) 100/110/120 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (with start-up lock) | Trip Characteristic: Undercurrent instantaneous; fixed time-limit at start-up | Control Voltage: 100/110/120 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-SU1N SAO Undercurrent, Instantaneous (w/o start-up lock) 100/110/120 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (w/o start-up lock) | Trip Characteristic: Undercurrent instantaneous; no start-up lock | Control Voltage: 100/110/120 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-R2N SAO Overcurrent, Inverse type 200/220/240 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Inverse type | Trip Characteristic: Overcurrent inverse-time trip | Control Voltage: 200/220/240 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-Q2N SAO Overcurrent, Instantaneous (with start-up lock) 200/220/240 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Instantaneous (with start-up lock) | Trip Characteristic: Overcurrent instantaneous; fixed time-limit at start-up | Control Voltage: 200/220/240 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-S2N SAO Undercurrent, Instantaneous (with start-up lock) 200/220/240 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (with start-up lock) | Trip Characteristic: Undercurrent instantaneous; fixed time-limit at start-up | Control Voltage: 200/220/240 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-SU2N SAO Undercurrent, Instantaneous (w/o start-up lock) 200/220/240 VAC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (w/o start-up lock) | Trip Characteristic: Undercurrent instantaneous; no start-up lock | Control Voltage: 200/220/240 VAC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-R5N SAO Overcurrent, Inverse type 24 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Inverse type | Trip Characteristic: Overcurrent inverse-time trip | Control Voltage: 24 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-Q5N SAO Overcurrent, Instantaneous (with start-up lock) 24 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Instantaneous (with start-up lock) | Trip Characteristic: Overcurrent instantaneous; fixed time-limit at start-up | Control Voltage: 24 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-S5N SAO Undercurrent, Instantaneous (with start-up lock) 24 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (with start-up lock) | Trip Characteristic: Undercurrent instantaneous; fixed time-limit at start-up | Control Voltage: 24 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-SU5N SAO Undercurrent, Instantaneous (w/o start-up lock) 24 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (w/o start-up lock) | Trip Characteristic: Undercurrent instantaneous; no start-up lock | Control Voltage: 24 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-R6N SAO Overcurrent, Inverse type 48 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Inverse type | Trip Characteristic: Overcurrent inverse-time trip | Control Voltage: 48 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-Q6N SAO Overcurrent, Instantaneous (with start-up lock) 48 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Instantaneous (with start-up lock) | Trip Characteristic: Overcurrent instantaneous; fixed time-limit at start-up | Control Voltage: 48 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-S6N SAO Undercurrent, Instantaneous (with start-up lock) 48 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (with start-up lock) | Trip Characteristic: Undercurrent instantaneous; fixed time-limit at start-up | Control Voltage: 48 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-SU6N SAO Undercurrent, Instantaneous (w/o start-up lock) 48 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (w/o start-up lock) | Trip Characteristic: Undercurrent instantaneous; no start-up lock | Control Voltage: 48 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-R7N SAO Overcurrent, Inverse type 100/110 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Inverse type | Trip Characteristic: Overcurrent inverse-time trip | Control Voltage: 100/110 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-Q7N SAO Overcurrent, Instantaneous (with start-up lock) 100/110 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Overcurrent, Instantaneous (with start-up lock) | Trip Characteristic: Overcurrent instantaneous; fixed time-limit at start-up | Control Voltage: 100/110 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-S7N SAO Undercurrent, Instantaneous (with start-up lock) 100/110 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (with start-up lock) | Trip Characteristic: Undercurrent instantaneous; fixed time-limit at start-up | Control Voltage: 100/110 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available
SAO-SU7N SAO Undercurrent, Instantaneous (w/o start-up lock) 100/110 VDC OMRON Type: Solid-state Plug-in Current Sensor | Function: Undercurrent, Instantaneous (w/o start-up lock) | Trip Characteristic: Undercurrent instantaneous; no start-up lock | Control Voltage: 100/110 VDC | Mount: Plug-in / DIN rail via socket | Note: Plug-in/DIN rail via socket (8PFA1 sold separately); current converters SET-3A/3B available