[Yuken] — ELDFHG-06-500 Two-Stage Proportional Directional & Flow Control Valve (E series, 31.5 MPa, rated 500 L/min, size 06)
Family ID: YK-ELDFHG-06-500
Two Stage Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A two-stage high-response directional/flow valve; the main spool position is detected by a differential transformer and controlled in a closed loop for high accuracy and reliability with simple-servo-class response, and the zero-lap 3C2P spool suits position and pressure control. Use with a dedicated Yuken external power amplifier. Sub-plate mounting, valve size 06, rated flow 500 L/min at 1 MPa valve pressure drop. Max operating pressure 31.5 MPa. Spool forms 3C2/3C40/3C2P; meter-in/meter-out (XY); internal/external pilot and drain. Solenoid rated current max 2.5 A, coil 3.9Ω, IP64.
12 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| ELDFHG-06-500-3C2-XY-E-T-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2, External pilot, Internal drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2 (neutral overlap) | Control Direction: XY (meter-in/meter-out) | Pilot: External pilot | Drain: Internal drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2-XY-E-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2, External pilot, External drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2 (neutral overlap) | Control Direction: XY (meter-in/meter-out) | Pilot: External pilot | Drain: External drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2-XY-T-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2, Internal pilot, Internal drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2 (neutral overlap) | Control Direction: XY (meter-in/meter-out) | Pilot: Internal pilot | Drain: Internal drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2-XY-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2, Internal pilot, External drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2 (neutral overlap) | Control Direction: XY (meter-in/meter-out) | Pilot: Internal pilot | Drain: External drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C40-XY-E-T-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C40, External pilot, Internal drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C40 (neutral A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Pilot: External pilot | Drain: Internal drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C40-XY-E-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C40, External pilot, External drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C40 (neutral A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Pilot: External pilot | Drain: External drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C40-XY-T-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C40, Internal pilot, Internal drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C40 (neutral A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Pilot: Internal pilot | Drain: Internal drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C40-XY-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C40, Internal pilot, External drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C40 (neutral A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Pilot: Internal pilot | Drain: External drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2P-XY-E-T-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2P, External pilot, Internal drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2P (neutral zero-lap) | Control Direction: XY (meter-in/meter-out) | Pilot: External pilot | Drain: Internal drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2P-XY-E-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2P, External pilot, External drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2P (neutral zero-lap) | Control Direction: XY (meter-in/meter-out) | Pilot: External pilot | Drain: External drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2P-XY-T-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2P, Internal pilot, Internal drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2P (neutral zero-lap) | Control Direction: XY (meter-in/meter-out) | Pilot: Internal pilot | Drain: Internal drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 | ||
| ELDFHG-06-500-3C2P-XY-10 | ELDFHG-06-500 2-stage Dir&Flow (E), 3C2P, Internal pilot, External drain | Yuken | Type: Two-Stage High-Response Proportional Directional & Flow Control Valve (E series) | Series: ELDFHG | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 500 L/min (@ΔP=1 MPa) | Max Pressure: 31.5 MPa | Spool Form: 3C2P (neutral zero-lap) | Control Direction: XY (meter-in/meter-out) | Pilot: Internal pilot | Drain: External drain | Solenoid: max 2.5 A, coil 3.9Ω | Feedback: Spool-position differential transformer (closed loop) | Protection: IP64 | Drive: Use with dedicated external power amplifier | Mass: 19 kg | Design No.: 10 |