Power Units
Yuken
[YUKEN] — PMR2 Power Package (Motor-Driven Integrated Type, 14 MPa)
Family ID: YK-PMR2
Power Package (Motor-Driven Integrated Type). YUKEN's power package compactly integrates a small high-pressure vane pump, relief valve and oil tank, and allows a hydraulic circuit to be configured simply by stacking 1/8 solenoid valves (or manual selector valves) and modular valves. The PMR2 is a motor-driven (motor-integrated) package driven on AC 200/220 V, suited to small machines and general industrial machinery. Circuits can be added or changed simply by adding or changing the modular valves stacked on the package, and the package can be used immediately just by hydraulic piping between it and the actuator. Fifteen standard circuits are available (see Yuken Cat. K-48/K-49). Solenoid valves use the DSG-01 series; manual selector valves use the DMG-01 series. Tank capacity 3.4 L. Relief setting range 3.5-14 MPa (specify as MPa x 10). Pump rotation is clockwise viewed from the motor fan side. Order code: PMR2-{size}-{relief}-{motor A/B/N}-{circuit 00-08}-{valve}-40.
12 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| PMR2-6-A | PMR2 motor-driven power package, 5.8cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 5.8 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-6-B | PMR2 motor-driven power package, 5.8cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 5.8 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-8-A | PMR2 motor-driven power package, 8.0cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 8.0 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-8-B | PMR2 motor-driven power package, 8.0cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 8.0 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-10-A | PMR2 motor-driven power package, 9.4cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 9.4 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-10-B | PMR2 motor-driven power package, 9.4cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 9.4 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-12-A | PMR2 motor-driven power package, 12.2cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 12.2 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-12-B | PMR2 motor-driven power package, 12.2cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 12.2 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-14-A | PMR2 motor-driven power package, 13.7cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 13.7 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-14-B | PMR2 motor-driven power package, 13.7cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 13.7 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-17-A | PMR2 motor-driven power package, 16.6cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 16.6 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | ||
| PMR2-17-B | PMR2 motor-driven power package, 16.6cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 16.6 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 |