[YUKEN] — YA-e Pack Energy-Saving Standard Hydraulic Power Unit (E-YA10/16/22/37, inverter, 0.75-7.5 kW, 18-160 L)

[YUKEN] — YA-e Pack Energy-Saving Standard Hydraulic Power Unit (E-YA10/16/22/37, inverter, 0.75-7.5 kW, 18-160 L)

Family ID: YK-EYA

Energy-Saving Standard Hydraulic Power Unit YA-e Pack. The YA-e Pack achieves substantial energy saving by combining the pressure-compensation mechanism of a variable piston pump with a dedicated inverter controller that detects load pressure and controls the motor speed. Greatly reduced power consumption: for the E-YA37, power consumption during full cut-off operation is reduced by more than 70% compared with the conventional YA Pack. Low noise: during full cut-off the motor speed drops, greatly reducing noise. Low heat generation: for the E-YA37, the oil-temperature rise during continuous full cut-off operation is lowered by more than 20 C versus the conventional YA Pack. Equal pump discharge in 50/60 Hz regions: the maximum-discharge speed can be set arbitrarily by the inverter up to 1800 r/min regardless of supply frequency (minimum 300 r/min depending on pump suction capacity). Control circuits are easily configured. Operation is possible even if the pressure sensor or inverter fails. Power supply: 50 Hz AC 200 V / 60 Hz AC 200, 220 or 230 V.

21 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
E-YA10-B-6-2.2-50 YA-e Pack A10 pump, B-range (1.2~7 MPa), 60L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump A10 (10.0 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 60 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 85 kg (excl. hydraulic oil) | Design No.: 50
E-YA10-C-10-2.2-50 YA-e Pack A10 pump, C-range (2.0~16 MPa), 100L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump A10 (10.0 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 115 kg (excl. hydraulic oil) | Design No.: 50
E-YA10-C-10-3.7-50 YA-e Pack A10 pump, C-range (2.0~16 MPa), 100L tank, 3.7 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump A10 (10.0 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 3.7 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 126 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-B-2-0.75-50 YA-e Pack AR16 pump, B-range (1.2~7 MPa), 18L tank, 0.75 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 18 L | Motor: 0.75 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 48 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-B-2-1.5-50 YA-e Pack AR16 pump, B-range (1.2~7 MPa), 18L tank, 1.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 18 L | Motor: 1.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 51 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-B-2-2.2-50 YA-e Pack AR16 pump, B-range (1.2~7 MPa), 18L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 18 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 58 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-B-6-2.2-50 YA-e Pack AR16 pump, B-range (1.2~7 MPa), 60L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 60 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 90 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-B-6-3.7-50 YA-e Pack AR16 pump, B-range (1.2~7 MPa), 60L tank, 3.7 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 60 L | Motor: 3.7 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 104 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-B-10-2.2-50 YA-e Pack AR16 pump, B-range (1.2~7 MPa), 100L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 100 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 115 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-C-10-3.7-50 YA-e Pack AR16 pump, C-range (2.0~16 MPa), 100L tank, 3.7 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 3.7 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 131 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-C-10-5.5-50 YA-e Pack AR16 pump, C-range (2.0~16 MPa), 100L tank, 5.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 5.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 159 kg (excl. hydraulic oil) | Design No.: 50
E-YA16-C-10-7.5-50 YA-e Pack AR16 pump, C-range (2.0~16 MPa), 100L tank, 7.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR16 (15.8 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 7.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 172 kg (excl. hydraulic oil) | Design No.: 50
E-YA22-B-6-2.2-50 YA-e Pack AR22 pump, B-range (1.2~7 MPa), 60L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR22 (22.2 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 60 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 90 kg (excl. hydraulic oil) | Design No.: 50
E-YA22-B-6-3.7-50 YA-e Pack AR22 pump, B-range (1.2~7 MPa), 60L tank, 3.7 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR22 (22.2 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 60 L | Motor: 3.7 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 104 kg (excl. hydraulic oil) | Design No.: 50
E-YA22-B-10-2.2-50 YA-e Pack AR22 pump, B-range (1.2~7 MPa), 100L tank, 2.2 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR22 (22.2 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 100 L | Motor: 2.2 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 120 kg (excl. hydraulic oil) | Design No.: 50
E-YA22-B-10-3.7-50 YA-e Pack AR22 pump, B-range (1.2~7 MPa), 100L tank, 3.7 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR22 (22.2 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 100 L | Motor: 3.7 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 156 kg (excl. hydraulic oil) | Design No.: 50
E-YA22-C-10-5.5-50 YA-e Pack AR22 pump, C-range (2.0~16 MPa), 100L tank, 5.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR22 (22.2 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 5.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 159 kg (excl. hydraulic oil) | Design No.: 50
E-YA22-C-10-7.5-50 YA-e Pack AR22 pump, C-range (2.0~16 MPa), 100L tank, 7.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump AR22 (22.2 cm3/rev) | Max Use Pressure: 16 MPa | Pressure Adjustment Range: 2.0~16 MPa (C-range) | Tank Capacity: 100 L | Motor: 7.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 172 kg (excl. hydraulic oil) | Design No.: 50
E-YA37-B-10-3.7-50 YA-e Pack A37 pump, B-range (1.2~7 MPa), 100L tank, 3.7 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump A37 (36.9 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 100 L | Motor: 3.7 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 151 kg (excl. hydraulic oil) | Design No.: 50
E-YA37-B-16-5.5-50 YA-e Pack A37 pump, B-range (1.2~7 MPa), 160L tank, 5.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump A37 (36.9 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 160 L | Motor: 5.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 189 kg (excl. hydraulic oil) | Design No.: 50
E-YA37-B-16-7.5-50 YA-e Pack A37 pump, B-range (1.2~7 MPa), 160L tank, 7.5 kW inverter YUKEN Type: Energy-Saving Standard Hydraulic Power Unit (inverter-controlled) | Pump: Variable Piston Pump A37 (36.9 cm3/rev) | Max Use Pressure: 7 MPa | Pressure Adjustment Range: 1.2~7 MPa (B-range) | Tank Capacity: 160 L | Motor: 7.5 kW x 4P (inverter, 300-1800 r/min) | Power Supply: 50Hz AC200V / 60Hz AC200V-220V-230V | Mass: 197 kg (excl. hydraulic oil) | Design No.: 50