Kyongbo Electric Ring Type Current Transformer 12 kV RV7A Series

Kyongbo Electric Ring Type Current Transformer 12 kV RV7A Series

Indoor epoxy vacuum-molded ring-type current transformer, 12 kV class, through which the primary cable or bus-bar passes, for metering and protection.

Key features

  • For metering and protection
  • Indoor use
  • Primary cable or bus-bar through type
  • Epoxy vacuum molding insulation
  • 1-core and 2-core versions
  • Versions with tertiary winding for ground-fault detection

Specifications

Rated Secondary Current 5 A or 1 A
Short-Time Current 40 In ~ 40 kA / 1 s
Rated Frequency 60 Hz (others on request)
Standards KS C 1706, JEC 1201, IEC 61869-2 (IEEE C57.13 on request)
RV75A Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 100~2000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75DA Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 200/100~2000/1000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75RA Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 75~2000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75DRA Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 150/75~2000/1000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75RAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 400~600/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75DRAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~600/300/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75RA Service: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 200~1000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75DRA Service: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 300/150~1000/500/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75RAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 400~1000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75DRAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV78A Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 150~4000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78DA Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 300/150~4000/2000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78RA Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 100~4000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78DRA Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 200/100~4000/2000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78RAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 400~1000/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78DRAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78RA Service: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 300~2000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78DRA Service: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78RAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 400~1000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78DRAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV710A Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 200~5000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710DA Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~5000/2500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710RA Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 120~5000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710DRA Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 240/120~5000/2500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710RAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 400~2500/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710DRAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~2500/1250/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710RA Service: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 600~2500/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710DRA Service: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 600/300~2500/1250/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710RAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 600~2500/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710DRAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 600/300~2500/1250/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV713A Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 250~5000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713DA Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 500/250~5000/2500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713RA Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 150~5000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713DRA Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 240/120~5000/2500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713RAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 500~4000/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713DRAT Service: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 500/250~4000/2000/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713RA Service: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 750~4000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713DRA Service: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 800/400~4000/2000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713RAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 750~4000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713DRAT Service: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 800/400~4000/2000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV716A Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 300~5000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
RV716DA Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 600/300~5000/2500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
RV716RA Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 200~5000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
RV716DRA Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~5000/2500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
Current TransformersKyongbo Electric
44 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Kyongbo Electric Ring Type Current Transformer 12 kV RV7A Series

Brand Kyongbo Electric·Current Transformers

Available part numbers (44)

RV75A, RV75DA, RV75RA, RV75DRA, RV75RAT, RV75DRAT, 2RV75RA, 2RV75DRA, 2RV75RAT, 2RV75DRAT + 34 more — see full table ↓

How to order

Send the Kyongbo Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
RV75AService: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 100~2000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75DAService: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 200/100~2000/1000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75RAService: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 75~2000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75DRAService: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 150/75~2000/1000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75RATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 400~600/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV75DRATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~600/300/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75RAService: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 200~1000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75DRAService: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 300/150~1000/500/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75RATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 400~1000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
2RV75DRATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 44 kg
RV78AService: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 150~4000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78DAService: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 300/150~4000/2000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78RAService: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 100~4000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78DRAService: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 200/100~4000/2000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78RATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 400~1000/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV78DRATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78RAService: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 300~2000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78DRAService: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78RATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 400~1000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
2RV78DRATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 40 kg
RV710AService: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 200~5000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710DAService: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~5000/2500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710RAService: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 120~5000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710DRAService: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 240/120~5000/2500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710RATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 400~2500/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV710DRATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~2500/1250/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710RAService: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 600~2500/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710DRAService: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 600/300~2500/1250/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710RATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 600~2500/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
2RV710DRATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 600/300~2500/1250/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 37 kg
RV713AService: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 250~5000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713DAService: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 500/250~5000/2500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713RAService: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 150~5000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713DRAService: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 240/120~5000/2500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713RATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Single | Current Ratio (A): 500~4000/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV713DRATService: Protection with tertiary winding (ground fault) | Cores: 1 | Ratio: Double | Current Ratio (A): 500/250~4000/2000/5, 100/5 | Accuracy Class: 1P / 5G (JEC) | Burden (VA): 40 / 15 (JEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713RAService: Metering and Protection | Cores: 2 | Ratio: Single | Current Ratio (A): 750~4000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713DRAService: Metering and Protection | Cores: 2 | Ratio: Double | Current Ratio (A): 800/400~4000/2000/5/5 | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Burden (VA): 15/15 or 40/40 (JEC) / 15/15 or 30/30 (IEC) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713RATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Single | Current Ratio (A): 750~4000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
2RV713DRATService: Metering and Protection with tertiary winding | Cores: 2 | Ratio: Double | Current Ratio (A): 800/400~4000/2000/5/5, 100/5 | Accuracy Class: 1.0/1P / 5G (JEC) | Burden (VA): 40/40 / 15 (JEC) | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Primary Through-Hole: dia. 134 mm | Weight: approx. 30 kg
RV716AService: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 300~5000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
RV716DAService: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 600/300~5000/2500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 11.5 kV; 11.5/28/75 kV (10B) | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
RV716RAService: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 200~5000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg
RV716DRAService: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~5000/2500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 11.5 kV; 11.5/28/75 kV | Max. Voltage / Insulation (IEC 61869-2): 12 kV; 12/28/75 kV | Primary Through-Hole: dia. 164 mm | Weight: approx. 26 kg

Need a different model, or a part not listed here? Send us your parts list →