Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| RH33 | Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 100~1000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 34 mm | Weight: approx. 9 kg | ||
| RH33D | Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~1000/500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 34 mm | Weight: approx. 9 kg | ||
| RH33R | Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 200~1000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 6.9 kV; 6.9/22/60 kV | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 34 mm | Weight: approx. 9 kg | ||
| RH33DR | Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 240/120~1000/500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 6.9 kV; 6.9/22/60 kV | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 34 mm | Weight: approx. 9 kg | ||
| RH35 | Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 250~2000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 8 kg | ||
| RH35D | Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 500/250~2000/1000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 8 kg | ||
| RH35R | Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 250~2000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 6.9 kV; 6.9/22/60 kV | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 8 kg | ||
| RH35DR | Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 300/150~2000/1000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 6.9 kV; 6.9/22/60 kV | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 54 mm | Weight: approx. 8 kg | ||
| RH38 | Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 300~3000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 7 kg | ||
| RH38D | Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 600/300~3000/1500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 7 kg | ||
| RH38R | Service: Protection | Cores: 1 | Ratio: Single | Current Ratio (A): 400~3000/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 6.9 kV; 6.9/22/60 kV | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 7 kg | ||
| RH38DR | Service: Protection | Cores: 1 | Ratio: Double | Current Ratio (A): 400/200~3000/1500/5 | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Burden (VA): 15 / 40 (JEC) / 15 / 30 (IEC) | Over-Current Factor: n>10 or 20 | Max. Voltage / Insulation (JEC 1201): 6.9 kV; 6.9/22/60 kV | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 84 mm | Weight: approx. 7 kg | ||
| RH310 | Service: Metering | Cores: 1 | Ratio: Single | Current Ratio (A): 400~3000/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 6 kg | ||
| RH310D | Service: Metering | Cores: 1 | Ratio: Double | Current Ratio (A): 800/400~3000/1500/5 | Accuracy Class: 0.5 / 1.0 | Burden (VA): 15 / 40 (KS) / 15 / 30 (IEC) | Max. Voltage / Insulation (KS C 1706): 7.2 kV; 7.2/22/60 kV (6A) | Max. Voltage / Insulation (IEC 61869-2): 7.2 kV; 7.2/20/60 kV | Primary Through-Hole: dia. 104 mm | Weight: approx. 6 kg |
Need a different model, or a part not listed here? Send us your parts list →