LS Electric L-Series (Beyond X) LA63Hd, LA63L and LA63Ld miniature circuit breakers for 1-63 A final circuits, in 1 to 4 poles with B, C, D, K and Z trip curves.

Key features

  • LA63Hd: 10 kA (IEC 60898-1), B/C/D curves, dual terminal (lug & screw)
  • LA63L: 15 kA (IEC 60898-1), up to 70 kA at 1-4 A to IEC 60947-2, B/C/D/K curves, lug terminal
  • LA63Ld: 15 kA dual-terminal version adding K and Z curves (launch scheduled Q4 2026)
  • 18 mm (17.6 mm) width per pole, uniform terminal height and handle position across the series
  • Field-fit LA-AX, LA-AL, LA-SHT and LA-U/OVT accessories and LA-MOP motor operator
  • Rated for AC and DC use: 1P 70 V DC, 2-4P 125 V DC (IEC 60947-2)

Specifications

Frame 63AF
Rated insulation voltage (Ui) 500 V
Rated impulse voltage (Uimp) 4 kV
Frequency 50/60 Hz
Ics 7.5 kA (LA63Hd/LA63L, IEC 60898-1)
Durability Electrical 10,000 / mechanical 20,000 ops
Pollution degree / IP Degree III / IP20
Ambient temperature -30 to +70 C
Terminal capacity Max. 25 mm2, 2 N.m
Certifications CE, CB, UKCA, CCC, KC
Mounting 35 mm DIN rail
Source LS Electric L-Series MCB & RCBO catalog (KO) C015X1-03, p. 4-5, 7-10
90740253 Model: LA63Hd | Poles: 1P | Rated current: 1 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740267 Model: LA63Hd | Poles: 1P | Rated current: 1 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740281 Model: LA63Hd | Poles: 1P | Rated current: 1 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740254 Model: LA63Hd | Poles: 1P | Rated current: 2 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740268 Model: LA63Hd | Poles: 1P | Rated current: 2 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740282 Model: LA63Hd | Poles: 1P | Rated current: 2 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740255 Model: LA63Hd | Poles: 1P | Rated current: 3 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740269 Model: LA63Hd | Poles: 1P | Rated current: 3 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740283 Model: LA63Hd | Poles: 1P | Rated current: 3 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740256 Model: LA63Hd | Poles: 1P | Rated current: 4 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740270 Model: LA63Hd | Poles: 1P | Rated current: 4 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740284 Model: LA63Hd | Poles: 1P | Rated current: 4 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740257 Model: LA63Hd | Poles: 1P | Rated current: 6 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740271 Model: LA63Hd | Poles: 1P | Rated current: 6 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740285 Model: LA63Hd | Poles: 1P | Rated current: 6 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740258 Model: LA63Hd | Poles: 1P | Rated current: 10 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740272 Model: LA63Hd | Poles: 1P | Rated current: 10 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740286 Model: LA63Hd | Poles: 1P | Rated current: 10 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740259 Model: LA63Hd | Poles: 1P | Rated current: 13 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740273 Model: LA63Hd | Poles: 1P | Rated current: 13 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740287 Model: LA63Hd | Poles: 1P | Rated current: 13 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740260 Model: LA63Hd | Poles: 1P | Rated current: 16 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740274 Model: LA63Hd | Poles: 1P | Rated current: 16 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740288 Model: LA63Hd | Poles: 1P | Rated current: 16 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740261 Model: LA63Hd | Poles: 1P | Rated current: 20 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740275 Model: LA63Hd | Poles: 1P | Rated current: 20 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740289 Model: LA63Hd | Poles: 1P | Rated current: 20 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740262 Model: LA63Hd | Poles: 1P | Rated current: 25 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740276 Model: LA63Hd | Poles: 1P | Rated current: 25 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740290 Model: LA63Hd | Poles: 1P | Rated current: 25 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740263 Model: LA63Hd | Poles: 1P | Rated current: 32 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740277 Model: LA63Hd | Poles: 1P | Rated current: 32 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740291 Model: LA63Hd | Poles: 1P | Rated current: 32 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740264 Model: LA63Hd | Poles: 1P | Rated current: 40 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740278 Model: LA63Hd | Poles: 1P | Rated current: 40 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740292 Model: LA63Hd | Poles: 1P | Rated current: 40 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740265 Model: LA63Hd | Poles: 1P | Rated current: 50 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740279 Model: LA63Hd | Poles: 1P | Rated current: 50 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740293 Model: LA63Hd | Poles: 1P | Rated current: 50 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740266 Model: LA63Hd | Poles: 1P | Rated current: 63 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740280 Model: LA63Hd | Poles: 1P | Rated current: 63 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740294 Model: LA63Hd | Poles: 1P | Rated current: 63 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740295 Model: LA63Hd | Poles: 2P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740309 Model: LA63Hd | Poles: 2P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740323 Model: LA63Hd | Poles: 2P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740296 Model: LA63Hd | Poles: 2P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740310 Model: LA63Hd | Poles: 2P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740324 Model: LA63Hd | Poles: 2P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740297 Model: LA63Hd | Poles: 2P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740311 Model: LA63Hd | Poles: 2P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740325 Model: LA63Hd | Poles: 2P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740298 Model: LA63Hd | Poles: 2P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740312 Model: LA63Hd | Poles: 2P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740326 Model: LA63Hd | Poles: 2P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740299 Model: LA63Hd | Poles: 2P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740313 Model: LA63Hd | Poles: 2P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740327 Model: LA63Hd | Poles: 2P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740300 Model: LA63Hd | Poles: 2P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740314 Model: LA63Hd | Poles: 2P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740328 Model: LA63Hd | Poles: 2P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740301 Model: LA63Hd | Poles: 2P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740315 Model: LA63Hd | Poles: 2P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740329 Model: LA63Hd | Poles: 2P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740302 Model: LA63Hd | Poles: 2P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740316 Model: LA63Hd | Poles: 2P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740330 Model: LA63Hd | Poles: 2P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740303 Model: LA63Hd | Poles: 2P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740317 Model: LA63Hd | Poles: 2P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740331 Model: LA63Hd | Poles: 2P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740304 Model: LA63Hd | Poles: 2P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740318 Model: LA63Hd | Poles: 2P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740332 Model: LA63Hd | Poles: 2P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740305 Model: LA63Hd | Poles: 2P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740319 Model: LA63Hd | Poles: 2P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740333 Model: LA63Hd | Poles: 2P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740306 Model: LA63Hd | Poles: 2P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740320 Model: LA63Hd | Poles: 2P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740334 Model: LA63Hd | Poles: 2P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740307 Model: LA63Hd | Poles: 2P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740321 Model: LA63Hd | Poles: 2P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740335 Model: LA63Hd | Poles: 2P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740308 Model: LA63Hd | Poles: 2P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740322 Model: LA63Hd | Poles: 2P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740336 Model: LA63Hd | Poles: 2P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740337 Model: LA63Hd | Poles: 3P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740351 Model: LA63Hd | Poles: 3P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740365 Model: LA63Hd | Poles: 3P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740338 Model: LA63Hd | Poles: 3P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740352 Model: LA63Hd | Poles: 3P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740366 Model: LA63Hd | Poles: 3P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740339 Model: LA63Hd | Poles: 3P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740353 Model: LA63Hd | Poles: 3P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740367 Model: LA63Hd | Poles: 3P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740340 Model: LA63Hd | Poles: 3P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740354 Model: LA63Hd | Poles: 3P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740368 Model: LA63Hd | Poles: 3P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740341 Model: LA63Hd | Poles: 3P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740355 Model: LA63Hd | Poles: 3P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740369 Model: LA63Hd | Poles: 3P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740342 Model: LA63Hd | Poles: 3P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740356 Model: LA63Hd | Poles: 3P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740370 Model: LA63Hd | Poles: 3P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740343 Model: LA63Hd | Poles: 3P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740357 Model: LA63Hd | Poles: 3P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740371 Model: LA63Hd | Poles: 3P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740344 Model: LA63Hd | Poles: 3P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740358 Model: LA63Hd | Poles: 3P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740372 Model: LA63Hd | Poles: 3P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740345 Model: LA63Hd | Poles: 3P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740359 Model: LA63Hd | Poles: 3P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740373 Model: LA63Hd | Poles: 3P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740346 Model: LA63Hd | Poles: 3P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740360 Model: LA63Hd | Poles: 3P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740374 Model: LA63Hd | Poles: 3P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740347 Model: LA63Hd | Poles: 3P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740361 Model: LA63Hd | Poles: 3P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740375 Model: LA63Hd | Poles: 3P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740348 Model: LA63Hd | Poles: 3P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740362 Model: LA63Hd | Poles: 3P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740376 Model: LA63Hd | Poles: 3P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740349 Model: LA63Hd | Poles: 3P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740363 Model: LA63Hd | Poles: 3P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740377 Model: LA63Hd | Poles: 3P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740350 Model: LA63Hd | Poles: 3P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740364 Model: LA63Hd | Poles: 3P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740378 Model: LA63Hd | Poles: 3P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740379 Model: LA63Hd | Poles: 4P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740393 Model: LA63Hd | Poles: 4P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740407 Model: LA63Hd | Poles: 4P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740380 Model: LA63Hd | Poles: 4P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740394 Model: LA63Hd | Poles: 4P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740408 Model: LA63Hd | Poles: 4P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740381 Model: LA63Hd | Poles: 4P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740395 Model: LA63Hd | Poles: 4P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740409 Model: LA63Hd | Poles: 4P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740382 Model: LA63Hd | Poles: 4P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740396 Model: LA63Hd | Poles: 4P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740410 Model: LA63Hd | Poles: 4P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740383 Model: LA63Hd | Poles: 4P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740397 Model: LA63Hd | Poles: 4P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740411 Model: LA63Hd | Poles: 4P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740384 Model: LA63Hd | Poles: 4P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740398 Model: LA63Hd | Poles: 4P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740412 Model: LA63Hd | Poles: 4P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740385 Model: LA63Hd | Poles: 4P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740399 Model: LA63Hd | Poles: 4P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740413 Model: LA63Hd | Poles: 4P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740386 Model: LA63Hd | Poles: 4P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740400 Model: LA63Hd | Poles: 4P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740414 Model: LA63Hd | Poles: 4P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740387 Model: LA63Hd | Poles: 4P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740401 Model: LA63Hd | Poles: 4P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740415 Model: LA63Hd | Poles: 4P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740388 Model: LA63Hd | Poles: 4P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740402 Model: LA63Hd | Poles: 4P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740416 Model: LA63Hd | Poles: 4P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740389 Model: LA63Hd | Poles: 4P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740403 Model: LA63Hd | Poles: 4P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740417 Model: LA63Hd | Poles: 4P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740390 Model: LA63Hd | Poles: 4P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740404 Model: LA63Hd | Poles: 4P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740418 Model: LA63Hd | Poles: 4P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740391 Model: LA63Hd | Poles: 4P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740405 Model: LA63Hd | Poles: 4P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740419 Model: LA63Hd | Poles: 4P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740392 Model: LA63Hd | Poles: 4P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740406 Model: LA63Hd | Poles: 4P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740420 Model: LA63Hd | Poles: 4P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90750001 Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750015 Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750029 Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750505 Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750002 Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750016 Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750030 Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750506 Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750003 Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750017 Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750031 Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750507 Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750004 Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750018 Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750032 Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750508 Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750005 Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750019 Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750033 Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750509 Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750006 Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750020 Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750034 Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750510 Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750007 Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750021 Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750035 Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750511 Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750008 Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750022 Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750036 Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750512 Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750009 Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750023 Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750037 Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750513 Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750010 Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750024 Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750038 Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750514 Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750011 Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750025 Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750039 Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750515 Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750012 Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750026 Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750040 Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750516 Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750013 Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750027 Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750041 Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750517 Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750014 Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750028 Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750042 Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750518 Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750085 Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750099 Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750113 Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750533 Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750086 Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750100 Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750114 Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750534 Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750087 Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750101 Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750115 Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750535 Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750088 Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750102 Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750116 Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750536 Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750089 Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750103 Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750117 Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750537 Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750090 Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750104 Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750118 Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750538 Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750091 Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750105 Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750119 Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750539 Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750092 Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750106 Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750120 Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750540 Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750093 Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750107 Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750121 Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750541 Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750094 Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750108 Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750122 Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750542 Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750095 Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750109 Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750123 Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750543 Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750096 Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750110 Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750124 Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750544 Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750097 Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750111 Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750125 Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750545 Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750098 Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750112 Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750126 Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750546 Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750127 Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750141 Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750155 Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750547 Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750128 Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750142 Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750156 Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750548 Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750129 Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750143 Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750157 Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750549 Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750130 Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750144 Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750158 Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750550 Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750131 Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750145 Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750159 Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750551 Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750132 Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750146 Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750160 Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750552 Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750133 Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750147 Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750161 Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750553 Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750134 Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750148 Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750162 Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750554 Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750135 Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750149 Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750163 Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750555 Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750136 Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750150 Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750164 Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750556 Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750137 Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750151 Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750165 Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750557 Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750138 Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750152 Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750166 Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750558 Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750139 Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750153 Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750167 Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750559 Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750140 Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750154 Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750168 Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750560 Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750211 Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750225 Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750239 Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750575 Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750212 Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750226 Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750240 Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750576 Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750213 Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750227 Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750241 Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750577 Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750214 Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750228 Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750242 Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750578 Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750215 Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750229 Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750243 Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750579 Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750216 Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750230 Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750244 Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750580 Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750217 Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750231 Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750245 Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750581 Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750218 Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750232 Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750246 Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750582 Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750219 Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750233 Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750247 Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750583 Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750220 Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750234 Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750248 Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750584 Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750221 Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750235 Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750249 Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750585 Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750222 Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750236 Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750250 Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750586 Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750223 Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750237 Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750251 Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750587 Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750224 Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750238 Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750252 Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750588 Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380001 Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380015 Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380029 Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380337 Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380253 Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380002 Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380016 Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380030 Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380338 Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380254 Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380003 Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380017 Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380031 Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380339 Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380255 Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380004 Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380018 Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380032 Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380340 Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380256 Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380005 Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380019 Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380033 Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380341 Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380257 Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380006 Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380020 Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380034 Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380342 Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380258 Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380007 Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380021 Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380035 Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380343 Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380259 Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380008 Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380022 Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380036 Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380344 Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380260 Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380009 Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380023 Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380037 Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380345 Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380261 Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380010 Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380024 Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380038 Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380346 Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380262 Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380011 Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380025 Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380039 Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380347 Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380263 Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380012 Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380026 Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380040 Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380348 Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380264 Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380013 Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380027 Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380041 Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380349 Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380265 Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380014 Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380028 Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380042 Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380350 Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380266 Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380085 Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380099 Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380113 Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380365 Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380281 Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380086 Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380100 Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380114 Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380366 Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380282 Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380087 Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380101 Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380115 Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380367 Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380283 Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380088 Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380102 Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380116 Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380368 Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380284 Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380089 Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380103 Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380117 Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380369 Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380285 Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380090 Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380104 Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380118 Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380370 Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380286 Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380091 Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380105 Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380119 Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380371 Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380287 Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380092 Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380106 Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380120 Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380372 Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380288 Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380093 Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380107 Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380121 Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380373 Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380289 Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380094 Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380108 Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380122 Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380374 Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380290 Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380095 Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380109 Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380123 Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380375 Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380291 Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380096 Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380110 Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380124 Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380376 Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380292 Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380097 Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380111 Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380125 Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380377 Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380293 Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380098 Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380112 Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380126 Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380378 Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380294 Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380127 Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380141 Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380155 Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380379 Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380295 Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380128 Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380142 Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380156 Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380380 Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380296 Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380129 Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380143 Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380157 Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380381 Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380297 Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380130 Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380144 Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380158 Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380382 Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380298 Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380131 Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380145 Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380159 Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380383 Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380299 Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380132 Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380146 Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380160 Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380384 Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380300 Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380133 Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380147 Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380161 Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380385 Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380301 Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380134 Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380148 Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380162 Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380386 Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380302 Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380135 Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380149 Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380163 Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380387 Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380303 Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380136 Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380150 Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380164 Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380388 Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380304 Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380137 Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380151 Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380165 Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380389 Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380305 Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380138 Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380152 Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380166 Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380390 Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380306 Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380139 Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380153 Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380167 Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380391 Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380307 Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380140 Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380154 Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380168 Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380392 Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380308 Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380211 Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380225 Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380239 Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380407 Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380323 Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380212 Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380226 Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380240 Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380408 Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380324 Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380213 Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380227 Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380241 Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380409 Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380325 Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380214 Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380228 Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380242 Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380410 Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380326 Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380215 Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380229 Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380243 Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380411 Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380327 Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380216 Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380230 Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380244 Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380412 Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380328 Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380217 Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380231 Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380245 Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380413 Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380329 Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380218 Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380232 Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380246 Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380414 Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380330 Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380219 Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380233 Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380247 Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380415 Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380331 Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380220 Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380234 Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380248 Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380416 Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380332 Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380221 Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380235 Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380249 Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380417 Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380333 Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380222 Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380236 Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380250 Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380418 Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380334 Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380223 Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380237 Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380251 Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380419 Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380335 Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380224 Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380238 Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380252 Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380420 Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380336 Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
Miniature Circuit BreakersLS Electric
672 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric L-Series LA63Hd/LA63L/LA63Ld MCB (1-63A, 10/15kA)

Brand LS Electric·Miniature Circuit Breakers

Available part numbers (672)

90740253, 90740267, 90740281, 90740254, 90740268, 90740282, 90740255, 90740269, 90740283, 90740256 + 662 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
90740253Model: LA63Hd | Poles: 1P | Rated current: 1 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740267Model: LA63Hd | Poles: 1P | Rated current: 1 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740281Model: LA63Hd | Poles: 1P | Rated current: 1 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740254Model: LA63Hd | Poles: 1P | Rated current: 2 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740268Model: LA63Hd | Poles: 1P | Rated current: 2 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740282Model: LA63Hd | Poles: 1P | Rated current: 2 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740255Model: LA63Hd | Poles: 1P | Rated current: 3 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740269Model: LA63Hd | Poles: 1P | Rated current: 3 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740283Model: LA63Hd | Poles: 1P | Rated current: 3 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740256Model: LA63Hd | Poles: 1P | Rated current: 4 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740270Model: LA63Hd | Poles: 1P | Rated current: 4 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740284Model: LA63Hd | Poles: 1P | Rated current: 4 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740257Model: LA63Hd | Poles: 1P | Rated current: 6 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740271Model: LA63Hd | Poles: 1P | Rated current: 6 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740285Model: LA63Hd | Poles: 1P | Rated current: 6 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740258Model: LA63Hd | Poles: 1P | Rated current: 10 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740272Model: LA63Hd | Poles: 1P | Rated current: 10 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740286Model: LA63Hd | Poles: 1P | Rated current: 10 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740259Model: LA63Hd | Poles: 1P | Rated current: 13 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740273Model: LA63Hd | Poles: 1P | Rated current: 13 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740287Model: LA63Hd | Poles: 1P | Rated current: 13 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740260Model: LA63Hd | Poles: 1P | Rated current: 16 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740274Model: LA63Hd | Poles: 1P | Rated current: 16 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740288Model: LA63Hd | Poles: 1P | Rated current: 16 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740261Model: LA63Hd | Poles: 1P | Rated current: 20 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740275Model: LA63Hd | Poles: 1P | Rated current: 20 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740289Model: LA63Hd | Poles: 1P | Rated current: 20 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740262Model: LA63Hd | Poles: 1P | Rated current: 25 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740276Model: LA63Hd | Poles: 1P | Rated current: 25 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740290Model: LA63Hd | Poles: 1P | Rated current: 25 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740263Model: LA63Hd | Poles: 1P | Rated current: 32 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740277Model: LA63Hd | Poles: 1P | Rated current: 32 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740291Model: LA63Hd | Poles: 1P | Rated current: 32 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740264Model: LA63Hd | Poles: 1P | Rated current: 40 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740278Model: LA63Hd | Poles: 1P | Rated current: 40 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740292Model: LA63Hd | Poles: 1P | Rated current: 40 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740265Model: LA63Hd | Poles: 1P | Rated current: 50 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740279Model: LA63Hd | Poles: 1P | Rated current: 50 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740293Model: LA63Hd | Poles: 1P | Rated current: 50 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740266Model: LA63Hd | Poles: 1P | Rated current: 63 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740280Model: LA63Hd | Poles: 1P | Rated current: 63 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740294Model: LA63Hd | Poles: 1P | Rated current: 63 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740295Model: LA63Hd | Poles: 2P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740309Model: LA63Hd | Poles: 2P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740323Model: LA63Hd | Poles: 2P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740296Model: LA63Hd | Poles: 2P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740310Model: LA63Hd | Poles: 2P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740324Model: LA63Hd | Poles: 2P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740297Model: LA63Hd | Poles: 2P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740311Model: LA63Hd | Poles: 2P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740325Model: LA63Hd | Poles: 2P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740298Model: LA63Hd | Poles: 2P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740312Model: LA63Hd | Poles: 2P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740326Model: LA63Hd | Poles: 2P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740299Model: LA63Hd | Poles: 2P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740313Model: LA63Hd | Poles: 2P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740327Model: LA63Hd | Poles: 2P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740300Model: LA63Hd | Poles: 2P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740314Model: LA63Hd | Poles: 2P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740328Model: LA63Hd | Poles: 2P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740301Model: LA63Hd | Poles: 2P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740315Model: LA63Hd | Poles: 2P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740329Model: LA63Hd | Poles: 2P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740302Model: LA63Hd | Poles: 2P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740316Model: LA63Hd | Poles: 2P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740330Model: LA63Hd | Poles: 2P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740303Model: LA63Hd | Poles: 2P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740317Model: LA63Hd | Poles: 2P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740331Model: LA63Hd | Poles: 2P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740304Model: LA63Hd | Poles: 2P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740318Model: LA63Hd | Poles: 2P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740332Model: LA63Hd | Poles: 2P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740305Model: LA63Hd | Poles: 2P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740319Model: LA63Hd | Poles: 2P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740333Model: LA63Hd | Poles: 2P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740306Model: LA63Hd | Poles: 2P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740320Model: LA63Hd | Poles: 2P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740334Model: LA63Hd | Poles: 2P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740307Model: LA63Hd | Poles: 2P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740321Model: LA63Hd | Poles: 2P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740335Model: LA63Hd | Poles: 2P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740308Model: LA63Hd | Poles: 2P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740322Model: LA63Hd | Poles: 2P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740336Model: LA63Hd | Poles: 2P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740337Model: LA63Hd | Poles: 3P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740351Model: LA63Hd | Poles: 3P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740365Model: LA63Hd | Poles: 3P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740338Model: LA63Hd | Poles: 3P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740352Model: LA63Hd | Poles: 3P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740366Model: LA63Hd | Poles: 3P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740339Model: LA63Hd | Poles: 3P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740353Model: LA63Hd | Poles: 3P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740367Model: LA63Hd | Poles: 3P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740340Model: LA63Hd | Poles: 3P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740354Model: LA63Hd | Poles: 3P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740368Model: LA63Hd | Poles: 3P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740341Model: LA63Hd | Poles: 3P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740355Model: LA63Hd | Poles: 3P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740369Model: LA63Hd | Poles: 3P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740342Model: LA63Hd | Poles: 3P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740356Model: LA63Hd | Poles: 3P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740370Model: LA63Hd | Poles: 3P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740343Model: LA63Hd | Poles: 3P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740357Model: LA63Hd | Poles: 3P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740371Model: LA63Hd | Poles: 3P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740344Model: LA63Hd | Poles: 3P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740358Model: LA63Hd | Poles: 3P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740372Model: LA63Hd | Poles: 3P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740345Model: LA63Hd | Poles: 3P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740359Model: LA63Hd | Poles: 3P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740373Model: LA63Hd | Poles: 3P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740346Model: LA63Hd | Poles: 3P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740360Model: LA63Hd | Poles: 3P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740374Model: LA63Hd | Poles: 3P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740347Model: LA63Hd | Poles: 3P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740361Model: LA63Hd | Poles: 3P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740375Model: LA63Hd | Poles: 3P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740348Model: LA63Hd | Poles: 3P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740362Model: LA63Hd | Poles: 3P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740376Model: LA63Hd | Poles: 3P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740349Model: LA63Hd | Poles: 3P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740363Model: LA63Hd | Poles: 3P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740377Model: LA63Hd | Poles: 3P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740350Model: LA63Hd | Poles: 3P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740364Model: LA63Hd | Poles: 3P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740378Model: LA63Hd | Poles: 3P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740379Model: LA63Hd | Poles: 4P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740393Model: LA63Hd | Poles: 4P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740407Model: LA63Hd | Poles: 4P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740380Model: LA63Hd | Poles: 4P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740394Model: LA63Hd | Poles: 4P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740408Model: LA63Hd | Poles: 4P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740381Model: LA63Hd | Poles: 4P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740395Model: LA63Hd | Poles: 4P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740409Model: LA63Hd | Poles: 4P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740382Model: LA63Hd | Poles: 4P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740396Model: LA63Hd | Poles: 4P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740410Model: LA63Hd | Poles: 4P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740383Model: LA63Hd | Poles: 4P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740397Model: LA63Hd | Poles: 4P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740411Model: LA63Hd | Poles: 4P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740384Model: LA63Hd | Poles: 4P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740398Model: LA63Hd | Poles: 4P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740412Model: LA63Hd | Poles: 4P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740385Model: LA63Hd | Poles: 4P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740399Model: LA63Hd | Poles: 4P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740413Model: LA63Hd | Poles: 4P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740386Model: LA63Hd | Poles: 4P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740400Model: LA63Hd | Poles: 4P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740414Model: LA63Hd | Poles: 4P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740387Model: LA63Hd | Poles: 4P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740401Model: LA63Hd | Poles: 4P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740415Model: LA63Hd | Poles: 4P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740388Model: LA63Hd | Poles: 4P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740402Model: LA63Hd | Poles: 4P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740416Model: LA63Hd | Poles: 4P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740389Model: LA63Hd | Poles: 4P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740403Model: LA63Hd | Poles: 4P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740417Model: LA63Hd | Poles: 4P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740390Model: LA63Hd | Poles: 4P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740404Model: LA63Hd | Poles: 4P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740418Model: LA63Hd | Poles: 4P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740391Model: LA63Hd | Poles: 4P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740405Model: LA63Hd | Poles: 4P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740419Model: LA63Hd | Poles: 4P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740392Model: LA63Hd | Poles: 4P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740406Model: LA63Hd | Poles: 4P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90740420Model: LA63Hd | Poles: 4P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 10 kA (IEC 60898-1)
90750001Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750015Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750029Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750505Model: LA63L | Poles: 1P | Rated current: 1 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750002Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750016Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750030Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750506Model: LA63L | Poles: 1P | Rated current: 2 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750003Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750017Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750031Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750507Model: LA63L | Poles: 1P | Rated current: 3 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750004Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750018Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750032Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750508Model: LA63L | Poles: 1P | Rated current: 4 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750005Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750019Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750033Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750509Model: LA63L | Poles: 1P | Rated current: 6 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750006Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750020Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750034Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750510Model: LA63L | Poles: 1P | Rated current: 10 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750007Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750021Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750035Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750511Model: LA63L | Poles: 1P | Rated current: 13 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750008Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750022Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750036Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750512Model: LA63L | Poles: 1P | Rated current: 16 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750009Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750023Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750037Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750513Model: LA63L | Poles: 1P | Rated current: 20 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750010Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750024Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750038Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750514Model: LA63L | Poles: 1P | Rated current: 25 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750011Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750025Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750039Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750515Model: LA63L | Poles: 1P | Rated current: 32 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750012Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750026Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750040Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750516Model: LA63L | Poles: 1P | Rated current: 40 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750013Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750027Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750041Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750517Model: LA63L | Poles: 1P | Rated current: 50 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750014Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750028Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750042Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750518Model: LA63L | Poles: 1P | Rated current: 63 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750085Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750099Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750113Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750533Model: LA63L | Poles: 2P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750086Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750100Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750114Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750534Model: LA63L | Poles: 2P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750087Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750101Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750115Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750535Model: LA63L | Poles: 2P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750088Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750102Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750116Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750536Model: LA63L | Poles: 2P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750089Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750103Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750117Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750537Model: LA63L | Poles: 2P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750090Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750104Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750118Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750538Model: LA63L | Poles: 2P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750091Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750105Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750119Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750539Model: LA63L | Poles: 2P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750092Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750106Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750120Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750540Model: LA63L | Poles: 2P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750093Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750107Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750121Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750541Model: LA63L | Poles: 2P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750094Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750108Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750122Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750542Model: LA63L | Poles: 2P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750095Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750109Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750123Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750543Model: LA63L | Poles: 2P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750096Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750110Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750124Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750544Model: LA63L | Poles: 2P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750097Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750111Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750125Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750545Model: LA63L | Poles: 2P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750098Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750112Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750126Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750546Model: LA63L | Poles: 2P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750127Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750141Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750155Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750547Model: LA63L | Poles: 3P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750128Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750142Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750156Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750548Model: LA63L | Poles: 3P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750129Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750143Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750157Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750549Model: LA63L | Poles: 3P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750130Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750144Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750158Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750550Model: LA63L | Poles: 3P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750131Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750145Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750159Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750551Model: LA63L | Poles: 3P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750132Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750146Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750160Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750552Model: LA63L | Poles: 3P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750133Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750147Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750161Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750553Model: LA63L | Poles: 3P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750134Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750148Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750162Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750554Model: LA63L | Poles: 3P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750135Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750149Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750163Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750555Model: LA63L | Poles: 3P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750136Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750150Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750164Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750556Model: LA63L | Poles: 3P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750137Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750151Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750165Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750557Model: LA63L | Poles: 3P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750138Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750152Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750166Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750558Model: LA63L | Poles: 3P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750139Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750153Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750167Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750559Model: LA63L | Poles: 3P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750140Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750154Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750168Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750560Model: LA63L | Poles: 3P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750211Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750225Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750239Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750575Model: LA63L | Poles: 4P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750212Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750226Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750240Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750576Model: LA63L | Poles: 4P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750213Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750227Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750241Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750577Model: LA63L | Poles: 4P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750214Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750228Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750242Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750578Model: LA63L | Poles: 4P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750215Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750229Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750243Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750579Model: LA63L | Poles: 4P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750216Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750230Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750244Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750580Model: LA63L | Poles: 4P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750217Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750231Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750245Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750581Model: LA63L | Poles: 4P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750218Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750232Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750246Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750582Model: LA63L | Poles: 4P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750219Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750233Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750247Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750583Model: LA63L | Poles: 4P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750220Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750234Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750248Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750584Model: LA63L | Poles: 4P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750221Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750235Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750249Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750585Model: LA63L | Poles: 4P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750222Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750236Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750250Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750586Model: LA63L | Poles: 4P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750223Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750237Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750251Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750587Model: LA63L | Poles: 4P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750224Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750238Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750252Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
90750588Model: LA63L | Poles: 4P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380001Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380015Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380029Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380337Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380253Model: LA63Ld | Poles: 1P | Rated current: 1 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380002Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380016Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380030Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380338Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380254Model: LA63Ld | Poles: 1P | Rated current: 2 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380003Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380017Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380031Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380339Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380255Model: LA63Ld | Poles: 1P | Rated current: 3 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380004Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380018Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380032Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380340Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380256Model: LA63Ld | Poles: 1P | Rated current: 4 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380005Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380019Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380033Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380341Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380257Model: LA63Ld | Poles: 1P | Rated current: 6 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380006Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380020Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380034Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380342Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380258Model: LA63Ld | Poles: 1P | Rated current: 10 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380007Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380021Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380035Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380343Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380259Model: LA63Ld | Poles: 1P | Rated current: 13 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380008Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380022Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380036Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380344Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380260Model: LA63Ld | Poles: 1P | Rated current: 16 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380009Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380023Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380037Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380345Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380261Model: LA63Ld | Poles: 1P | Rated current: 20 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380010Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380024Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380038Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380346Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380262Model: LA63Ld | Poles: 1P | Rated current: 25 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380011Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380025Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380039Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380347Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380263Model: LA63Ld | Poles: 1P | Rated current: 32 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380012Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380026Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380040Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380348Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380264Model: LA63Ld | Poles: 1P | Rated current: 40 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380013Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380027Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380041Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380349Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380265Model: LA63Ld | Poles: 1P | Rated current: 50 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380014Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: B | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380028Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: C | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380042Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: D | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380350Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: K | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380266Model: LA63Ld | Poles: 1P | Rated current: 63 A | Trip curve: Z | Rated voltage: 240/415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380085Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380099Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380113Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380365Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380281Model: LA63Ld | Poles: 2P | Rated current: 1 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380086Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380100Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380114Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380366Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380282Model: LA63Ld | Poles: 2P | Rated current: 2 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380087Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380101Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380115Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380367Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380283Model: LA63Ld | Poles: 2P | Rated current: 3 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380088Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380102Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380116Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380368Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380284Model: LA63Ld | Poles: 2P | Rated current: 4 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380089Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380103Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380117Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380369Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380285Model: LA63Ld | Poles: 2P | Rated current: 6 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380090Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380104Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380118Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380370Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380286Model: LA63Ld | Poles: 2P | Rated current: 10 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380091Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380105Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380119Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380371Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380287Model: LA63Ld | Poles: 2P | Rated current: 13 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380092Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380106Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380120Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380372Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380288Model: LA63Ld | Poles: 2P | Rated current: 16 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380093Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380107Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380121Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380373Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380289Model: LA63Ld | Poles: 2P | Rated current: 20 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380094Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380108Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380122Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380374Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380290Model: LA63Ld | Poles: 2P | Rated current: 25 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380095Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380109Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380123Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380375Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380291Model: LA63Ld | Poles: 2P | Rated current: 32 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380096Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380110Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380124Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380376Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380292Model: LA63Ld | Poles: 2P | Rated current: 40 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380097Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380111Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380125Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380377Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380293Model: LA63Ld | Poles: 2P | Rated current: 50 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380098Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380112Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380126Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380378Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380294Model: LA63Ld | Poles: 2P | Rated current: 63 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380127Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380141Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380155Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380379Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380295Model: LA63Ld | Poles: 3P | Rated current: 1 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380128Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380142Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380156Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380380Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380296Model: LA63Ld | Poles: 3P | Rated current: 2 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380129Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380143Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380157Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380381Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380297Model: LA63Ld | Poles: 3P | Rated current: 3 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380130Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380144Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380158Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380382Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380298Model: LA63Ld | Poles: 3P | Rated current: 4 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380131Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380145Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380159Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380383Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380299Model: LA63Ld | Poles: 3P | Rated current: 6 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380132Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380146Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380160Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380384Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380300Model: LA63Ld | Poles: 3P | Rated current: 10 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380133Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380147Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380161Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380385Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380301Model: LA63Ld | Poles: 3P | Rated current: 13 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380134Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380148Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380162Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380386Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380302Model: LA63Ld | Poles: 3P | Rated current: 16 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380135Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380149Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380163Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380387Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380303Model: LA63Ld | Poles: 3P | Rated current: 20 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380136Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380150Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380164Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380388Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380304Model: LA63Ld | Poles: 3P | Rated current: 25 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380137Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380151Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380165Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380389Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380305Model: LA63Ld | Poles: 3P | Rated current: 32 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380138Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380152Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380166Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380390Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380306Model: LA63Ld | Poles: 3P | Rated current: 40 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380139Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380153Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380167Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380391Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380307Model: LA63Ld | Poles: 3P | Rated current: 50 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380140Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380154Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380168Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380392Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380308Model: LA63Ld | Poles: 3P | Rated current: 63 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380211Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380225Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380239Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380407Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380323Model: LA63Ld | Poles: 4P | Rated current: 1 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380212Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380226Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380240Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380408Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380324Model: LA63Ld | Poles: 4P | Rated current: 2 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380213Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380227Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380241Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380409Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380325Model: LA63Ld | Poles: 4P | Rated current: 3 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380214Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380228Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380242Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380410Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380326Model: LA63Ld | Poles: 4P | Rated current: 4 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380215Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380229Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380243Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380411Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380327Model: LA63Ld | Poles: 4P | Rated current: 6 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380216Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380230Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380244Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380412Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380328Model: LA63Ld | Poles: 4P | Rated current: 10 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380217Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380231Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380245Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380413Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380329Model: LA63Ld | Poles: 4P | Rated current: 13 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380218Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380232Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380246Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380414Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380330Model: LA63Ld | Poles: 4P | Rated current: 16 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380219Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380233Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380247Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380415Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380331Model: LA63Ld | Poles: 4P | Rated current: 20 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380220Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380234Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380248Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380416Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380332Model: LA63Ld | Poles: 4P | Rated current: 25 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380221Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380235Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380249Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380417Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380333Model: LA63Ld | Poles: 4P | Rated current: 32 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380222Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380236Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380250Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380418Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380334Model: LA63Ld | Poles: 4P | Rated current: 40 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380223Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380237Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380251Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380419Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380335Model: LA63Ld | Poles: 4P | Rated current: 50 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380224Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: B | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380238Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: C | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380252Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: D | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380420Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: K | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)
70380336Model: LA63Ld | Poles: 4P | Rated current: 63 A | Trip curve: Z | Rated voltage: 415V AC | Breaking capacity: 15 kA (IEC 60898-1)

Need a different model, or a part not listed here? Send us your parts list →