Key features

  • High-breaking AS type: Icu 85 kA at 415/690 V; Icw 85 kA 1 s; AS-40E fixed vertical busbar only
  • Ordering code: type-frame-poles - rated current + mounting, then trip relay (e.g. AS-20E4-08J NH0); motor, closing/shunt coil, aux contact, UVT and option tokens (e.g. M1D1D1AX ... U1 AL) are added per order
  • Trip relays N (Normal), A (Ammeter), P (Power meter) and S (Supreme meter) with L/S/I/G protection; P/S types add voltage, frequency and power protection, 3.5 in touch LCD
  • Draw-out (manual or auto connection, cradle ordered separately) or fixed type; 3-pole or 4-pole with 100% rated N pole
  • Shared Metasol ACB accessories: motor charge, closing coil, shunt trip, UVT, aux contacts, key lock, mechanical interlock, counter

Specifications

Rated operational voltage (Ue) AC 690 V, 50/60 Hz
Rated insulation voltage (Ui) AC 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Icu at 415 V 85 kA
Ics 100% Icu
Icw (1 s) 85 kA
Icm at 415 V (peak) 187 kA
Mechanical / electrical life 15,000 / 5,000 operations
Current setting Ir = 0.4-1.0 x In (trip relay)
Standards IEC 60947-2, KS C 4620
Source LS Electric Metasol ACB catalog C06091-28 (2026.07), p. 19
AS-20E3-02JNH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-02JAH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-02JAH1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-02JAD1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JAJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JAY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JAO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JPS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-02JPJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-02JPY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-02JPO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-02JSS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02JSJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02JSY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02JSO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HNH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-02HAH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-02HAH1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-02HAD1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HAJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HAY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HAO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HPS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-02HPJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-02HPY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-02HPO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-02HSS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HSJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HSY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HSO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JNH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-04JAH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-04JAH1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-04JAD1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JAJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JAY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JAO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JPS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-04JPJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-04JPY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-04JPO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-04JSS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JSJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JSY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JSO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HNH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-04HAH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-04HAH1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-04HAD1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HAJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HAY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HAO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HPS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-04HPJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-04HPY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-04HPO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-04HSS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HSJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HSY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HSO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JNH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-06JAH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-06JAH1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-06JAD1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JAJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JAY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JAO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JPS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-06JPJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-06JPY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-06JPO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-06JSS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JSJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JSY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JSO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HNH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-06HAH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-06HAH1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-06HAD1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HAJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HAY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HAO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HPS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-06HPJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-06HPY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-06HPO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-06HSS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HSJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HSY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HSO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JNH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-08JAH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-08JAH1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-08JAD1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JAJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JAY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JAO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JPS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-08JPJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-08JPY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-08JPO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-08JSS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JSJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JSY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JSO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HNH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-08HAH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-08HAH1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-08HAD1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HAJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HAY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HAO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HPS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-08HPJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-08HPY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-08HPO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-08HSS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HSJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HSY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HSO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JNH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-10JAH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-10JAH1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-10JAD1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JAJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JAY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JAO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JPS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-10JPJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-10JPY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-10JPO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-10JSS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JSJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JSY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JSO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HNH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-10HAH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-10HAH1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-10HAD1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HAJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HAY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HAO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HPS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-10HPJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-10HPY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-10HPO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-10HSS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HSJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HSY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HSO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JNH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-13JAH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-13JAH1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-13JAD1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JAJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JAY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JAO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JPS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-13JPJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-13JPY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-13JPO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-13JSS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JSJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JSY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JSO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HNH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-13HAH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-13HAH1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-13HAD1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HAJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HAY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HAO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HPS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-13HPJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-13HPY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-13HPO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-13HSS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HSJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HSY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HSO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JNH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-16JAH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-16JAH1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-16JAD1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JAJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JAY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JAO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JPS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-16JPJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-16JPY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-16JPO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-16JSS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JSJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JSY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JSO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HNH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-16HAH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-16HAH1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-16HAD1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HAJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HAY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HAO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HPS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-16HPJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-16HPY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-16HPO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-16HSS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HSJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HSY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HSO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JNH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-20JAH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-20JAH1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-20JAD1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JAJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JAY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JAO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JPS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-20JPJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-20JPY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-20JPO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-20JSS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JSJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JSY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JSO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HNH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-20HAH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-20HAH1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-20HAD1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HAJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HAY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HAO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HPS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-20HPJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-20HPY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-20HPO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-20HSS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HSJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HSY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HSO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JNH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-02JAH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-02JAH1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-02JAD1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JAJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JAY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JAO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JPS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-02JPJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-02JPY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-02JPO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-02JSS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JSJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JSY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JSO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HNH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-02HAH0 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-02HAH1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-02HAD1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HAJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HAY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HAO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HPS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-02HPJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-02HPY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-02HPO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-02HSS1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HSJ1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HSY1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HSO1 Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JNH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-04JAH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-04JAH1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-04JAD1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JAJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JAY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JAO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JPS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-04JPJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-04JPY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-04JPO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-04JSS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JSJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JSY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JSO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HNH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-04HAH0 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-04HAH1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-04HAD1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HAJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HAY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HAO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HPS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-04HPJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-04HPY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-04HPO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-04HSS1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HSJ1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HSY1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HSO1 Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JNH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-06JAH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-06JAH1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-06JAD1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JAJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JAY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JAO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JPS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-06JPJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-06JPY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-06JPO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-06JSS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JSJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JSY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JSO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HNH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-06HAH0 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-06HAH1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-06HAD1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HAJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HAY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HAO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HPS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-06HPJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-06HPY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-06HPO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-06HSS1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HSJ1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HSY1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HSO1 Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JNH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-08JAH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-08JAH1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-08JAD1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JAJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JAY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JAO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JPS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-08JPJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-08JPY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-08JPO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-08JSS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JSJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JSY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JSO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HNH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-08HAH0 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-08HAH1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-08HAD1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HAJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HAY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HAO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HPS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-08HPJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-08HPY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-08HPO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-08HSS1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HSJ1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HSY1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HSO1 Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JNH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-10JAH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-10JAH1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-10JAD1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JAJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JAY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JAO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JPS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-10JPJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-10JPY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-10JPO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-10JSS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JSJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JSY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JSO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HNH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-10HAH0 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-10HAH1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-10HAD1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HAJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HAY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HAO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HPS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-10HPJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-10HPY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-10HPO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-10HSS1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HSJ1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HSY1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HSO1 Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JNH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-13JAH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-13JAH1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-13JAD1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JAJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JAY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JAO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JPS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-13JPJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-13JPY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-13JPO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-13JSS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JSJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JSY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JSO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HNH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-13HAH0 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-13HAH1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-13HAD1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HAJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HAY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HAO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HPS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-13HPJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-13HPY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-13HPO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-13HSS1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HSJ1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HSY1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HSO1 Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JNH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-16JAH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-16JAH1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-16JAD1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JAJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JAY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JAO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JPS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-16JPJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-16JPY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-16JPO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-16JSS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JSJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JSY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JSO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HNH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-16HAH0 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-16HAH1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-16HAD1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HAJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HAY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HAO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HPS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-16HPJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-16HPY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-16HPO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-16HSS1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HSJ1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HSY1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HSO1 Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JNH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-20JAH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-20JAH1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-20JAD1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JAJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JAY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JAO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JPS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-20JPJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-20JPY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-20JPO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-20JSS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JSJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JSY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JSO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HNH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-20HAH0 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-20HAH1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-20HAD1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HAJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HAY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HAO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HPS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-20HPJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-20HPY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-20HPO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-20HSS1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HSJ1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HSY1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HSO1 Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JNH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E3-25JAH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E3-25JAH1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E3-25JAD1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JAJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JAY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JAO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JPS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E3-25JPJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E3-25JPY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E3-25JPO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E3-25JSS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JSJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JSY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JSO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HNH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E3-25HAH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E3-25HAH1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E3-25HAD1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HAJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HAY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HAO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HPS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E3-25HPJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E3-25HPY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E3-25HPO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E3-25HSS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HSJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HSY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HSO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JNH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E4-25JAH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E4-25JAH1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E4-25JAD1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JAJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JAY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JAO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JPS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E4-25JPJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E4-25JPY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E4-25JPO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E4-25JSS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JSJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JSY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JSO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HNH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E4-25HAH0 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E4-25HAH1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E4-25HAD1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HAJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HAY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HAO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HPS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E4-25HPJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E4-25HPY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E4-25HPO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E4-25HSS1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HSJ1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HSY1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HSO1 Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JNH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E3-32JAH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E3-32JAH1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E3-32JAD1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JAJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JAY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JAO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JPS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E3-32JPJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E3-32JPY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E3-32JPO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E3-32JSS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JSJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JSY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JSO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HNH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E3-32HAH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E3-32HAH1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E3-32HAD1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HAJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HAY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HAO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HPS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E3-32HPJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E3-32HPY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E3-32HPO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E3-32HSS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HSJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HSY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HSO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JNH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E4-32JAH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E4-32JAH1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E4-32JAD1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JAJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JAY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JAO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JPS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E4-32JPJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E4-32JPY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E4-32JPO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E4-32JSS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JSJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JSY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JSO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HNH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E4-32HAH0 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E4-32HAH1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E4-32HAD1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HAJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HAY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HAO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HPS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E4-32HPJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E4-32HPY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E4-32HPO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E4-32HSS1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HSJ1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HSY1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HSO1 Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JNH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E3-40JAH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E3-40JAH1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E3-40JAD1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JAJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JAY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JAO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JPS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E3-40JPJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E3-40JPY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E3-40JPO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E3-40JSS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JSJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JSY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JSO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VNH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E3-40VAH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E3-40VAH1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E3-40VAD1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VAJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VAY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VAO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VPS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E3-40VPJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E3-40VPY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E3-40VPO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E3-40VSS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VSJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VSY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VSO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JNH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E4-40JAH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E4-40JAH1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E4-40JAD1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JAJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JAY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JAO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JPS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E4-40JPJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E4-40JPY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E4-40JPO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E4-40JSS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JSJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JSY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JSO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VNH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E4-40VAH0 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E4-40VAH1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E4-40VAD1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VAJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VAY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VAO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VPS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E4-40VPJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E4-40VPY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E4-40VPO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E4-40VSS1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VSJ1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VSY1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VSO1 Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
Air Circuit BreakersLS Electric
660 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric Metasol ACB AS-E Air Circuit Breaker (2000-4000AF)

Brand LS Electric·Air Circuit Breakers

Available part numbers (660)

AS-20E3-02JNH0, AS-20E3-02JAH0, AS-20E3-02JAH1, AS-20E3-02JAD1, AS-20E3-02JAJ1, AS-20E3-02JAY1, AS-20E3-02JAO1, AS-20E3-02JPS1, AS-20E3-02JPJ1, AS-20E3-02JPY1 + 650 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
AS-20E3-02JNH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-02JAH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-02JAH1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-02JAD1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JAJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JAY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JAO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02JPS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-02JPJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-02JPY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-02JPO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-02JSS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02JSJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02JSY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02JSO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HNH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-02HAH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-02HAH1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-02HAD1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HAJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HAY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HAO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-02HPS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-02HPJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-02HPY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-02HPO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-02HSS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HSJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HSY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-02HSO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JNH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-04JAH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-04JAH1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-04JAD1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JAJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JAY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JAO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04JPS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-04JPJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-04JPY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-04JPO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-04JSS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JSJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JSY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04JSO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HNH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-04HAH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-04HAH1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-04HAD1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HAJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HAY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HAO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-04HPS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-04HPJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-04HPY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-04HPO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-04HSS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HSJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HSY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-04HSO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JNH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-06JAH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-06JAH1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-06JAD1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JAJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JAY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JAO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06JPS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-06JPJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-06JPY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-06JPO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-06JSS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JSJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JSY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06JSO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HNH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-06HAH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-06HAH1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-06HAD1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HAJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HAY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HAO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-06HPS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-06HPJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-06HPY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-06HPO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-06HSS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HSJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HSY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-06HSO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JNH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-08JAH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-08JAH1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-08JAD1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JAJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JAY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JAO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08JPS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-08JPJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-08JPY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-08JPO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-08JSS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JSJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JSY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08JSO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HNH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-08HAH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-08HAH1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-08HAD1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HAJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HAY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HAO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-08HPS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-08HPJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-08HPY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-08HPO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-08HSS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HSJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HSY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-08HSO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JNH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-10JAH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-10JAH1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-10JAD1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JAJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JAY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JAO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10JPS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-10JPJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-10JPY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-10JPO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-10JSS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JSJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JSY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10JSO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HNH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-10HAH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-10HAH1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-10HAD1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HAJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HAY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HAO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-10HPS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-10HPJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-10HPY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-10HPO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-10HSS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HSJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HSY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-10HSO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JNH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-13JAH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-13JAH1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-13JAD1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JAJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JAY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JAO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13JPS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-13JPJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-13JPY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-13JPO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-13JSS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JSJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JSY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13JSO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HNH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-13HAH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-13HAH1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-13HAD1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HAJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HAY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HAO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-13HPS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-13HPJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-13HPY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-13HPO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-13HSS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HSJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HSY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-13HSO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JNH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-16JAH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-16JAH1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-16JAD1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JAJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JAY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JAO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16JPS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-16JPJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-16JPY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-16JPO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-16JSS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JSJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JSY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16JSO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HNH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-16HAH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-16HAH1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-16HAD1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HAJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HAY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HAO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-16HPS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-16HPJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-16HPY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-16HPO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-16HSS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HSJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HSY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-16HSO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JNH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-20JAH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-20JAH1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-20JAD1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JAJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JAY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JAO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20JPS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-20JPJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-20JPY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-20JPO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-20JSS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JSJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JSY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20JSO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HNH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E3-20HAH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E3-20HAH1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E3-20HAD1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HAJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HAY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HAO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E3-20HPS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E3-20HPJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E3-20HPY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E3-20HPO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E3-20HSS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HSJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HSY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E3-20HSO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JNH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-02JAH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-02JAH1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-02JAD1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JAJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JAY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JAO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02JPS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-02JPJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-02JPY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-02JPO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-02JSS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JSJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JSY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02JSO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HNH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-02HAH0Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-02HAH1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-02HAD1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HAJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HAY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HAO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-02HPS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-02HPJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-02HPY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-02HPO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-02HSS1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HSJ1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HSY1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-02HSO1Frame: AS-20E, 2000AF | Rated current In: 200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JNH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-04JAH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-04JAH1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-04JAD1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JAJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JAY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JAO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04JPS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-04JPJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-04JPY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-04JPO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-04JSS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JSJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JSY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04JSO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HNH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-04HAH0Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-04HAH1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-04HAD1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HAJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HAY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HAO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-04HPS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-04HPJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-04HPY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-04HPO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-04HSS1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HSJ1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HSY1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-04HSO1Frame: AS-20E, 2000AF | Rated current In: 400 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JNH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-06JAH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-06JAH1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-06JAD1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JAJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JAY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JAO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06JPS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-06JPJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-06JPY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-06JPO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-06JSS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JSJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JSY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06JSO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HNH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-06HAH0Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-06HAH1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-06HAD1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HAJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HAY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HAO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-06HPS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-06HPJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-06HPY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-06HPO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-06HSS1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HSJ1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HSY1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-06HSO1Frame: AS-20E, 2000AF | Rated current In: 630 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JNH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-08JAH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-08JAH1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-08JAD1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JAJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JAY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JAO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08JPS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-08JPJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-08JPY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-08JPO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-08JSS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JSJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JSY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08JSO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HNH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-08HAH0Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-08HAH1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-08HAD1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HAJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HAY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HAO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-08HPS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-08HPJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-08HPY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-08HPO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-08HSS1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HSJ1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HSY1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-08HSO1Frame: AS-20E, 2000AF | Rated current In: 800 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JNH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-10JAH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-10JAH1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-10JAD1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JAJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JAY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JAO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10JPS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-10JPJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-10JPY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-10JPO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-10JSS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JSJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JSY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10JSO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HNH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-10HAH0Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-10HAH1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-10HAD1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HAJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HAY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HAO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-10HPS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-10HPJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-10HPY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-10HPO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-10HSS1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HSJ1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HSY1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-10HSO1Frame: AS-20E, 2000AF | Rated current In: 1000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JNH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-13JAH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-13JAH1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-13JAD1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JAJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JAY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JAO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13JPS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-13JPJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-13JPY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-13JPO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-13JSS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JSJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JSY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13JSO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HNH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-13HAH0Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-13HAH1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-13HAD1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HAJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HAY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HAO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-13HPS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-13HPJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-13HPY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-13HPO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-13HSS1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HSJ1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HSY1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-13HSO1Frame: AS-20E, 2000AF | Rated current In: 1250 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JNH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-16JAH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-16JAH1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-16JAD1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JAJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JAY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JAO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16JPS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-16JPJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-16JPY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-16JPO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-16JSS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JSJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JSY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16JSO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HNH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-16HAH0Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-16HAH1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-16HAD1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HAJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HAY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HAO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-16HPS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-16HPJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-16HPY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-16HPO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-16HSS1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HSJ1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HSY1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-16HSO1Frame: AS-20E, 2000AF | Rated current In: 1600 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JNH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-20JAH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-20JAH1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-20JAD1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JAJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JAY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JAO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20JPS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-20JPJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-20JPY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-20JPO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-20JSS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JSJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JSY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20JSO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HNH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-20E4-20HAH0Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-20E4-20HAH1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-20E4-20HAD1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HAJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HAY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HAO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-20E4-20HPS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-20E4-20HPJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-20E4-20HPY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-20E4-20HPO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-20E4-20HSS1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HSJ1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HSY1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-20E4-20HSO1Frame: AS-20E, 2000AF | Rated current In: 2000 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JNH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E3-25JAH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E3-25JAH1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E3-25JAD1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JAJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JAY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JAO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25JPS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E3-25JPJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E3-25JPY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E3-25JPO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E3-25JSS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JSJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JSY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25JSO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HNH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E3-25HAH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E3-25HAH1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E3-25HAD1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HAJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HAY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HAO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E3-25HPS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E3-25HPJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E3-25HPY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E3-25HPO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E3-25HSS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HSJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HSY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E3-25HSO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JNH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E4-25JAH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E4-25JAH1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E4-25JAD1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JAJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JAY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JAO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25JPS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E4-25JPJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E4-25JPY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E4-25JPO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E4-25JSS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JSJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JSY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25JSO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HNH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-25E4-25HAH0Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-25E4-25HAH1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-25E4-25HAD1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HAJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HAY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HAO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-25E4-25HPS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-25E4-25HPJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-25E4-25HPY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-25E4-25HPO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-25E4-25HSS1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HSJ1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HSY1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-25E4-25HSO1Frame: AS-25E, 2500AF | Rated current In: 2500 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JNH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E3-32JAH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E3-32JAH1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E3-32JAD1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JAJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JAY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JAO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32JPS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E3-32JPJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E3-32JPY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E3-32JPO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E3-32JSS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JSJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JSY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32JSO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HNH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E3-32HAH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E3-32HAH1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E3-32HAD1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HAJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HAY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HAO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E3-32HPS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E3-32HPJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E3-32HPY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E3-32HPO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E3-32HSS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HSJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HSY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E3-32HSO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 3P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JNH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E4-32JAH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E4-32JAH1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E4-32JAD1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JAJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JAY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JAO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32JPS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E4-32JPJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E4-32JPY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E4-32JPO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E4-32JSS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JSJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JSY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32JSO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HNH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-32E4-32HAH0Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-32E4-32HAH1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-32E4-32HAD1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HAJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HAY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HAO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-32E4-32HPS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-32E4-32HPJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-32E4-32HPY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-32E4-32HPO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-32E4-32HSS1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HSJ1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HSY1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-32E4-32HSO1Frame: AS-32E, 3200AF | Rated current In: 3200 A | Poles: 4P | Mounting: Fixed, horizontal busbar (H) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JNH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E3-40JAH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E3-40JAH1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E3-40JAD1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JAJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JAY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JAO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40JPS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E3-40JPJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E3-40JPY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E3-40JPO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E3-40JSS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JSJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JSY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40JSO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VNH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E3-40VAH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E3-40VAH1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E3-40VAD1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VAJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VAY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VAO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E3-40VPS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E3-40VPJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E3-40VPY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E3-40VPO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E3-40VSS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VSJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VSY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E3-40VSO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 3P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JNH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E4-40JAH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E4-40JAH1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E4-40JAD1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JAJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JAY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JAO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40JPS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E4-40JPJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E4-40JPY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E4-40JPO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E4-40JSS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JSJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JSY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40JSO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Draw-out, manual connection (J) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VNH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: N (Normal), L/S/I/G | Control power: Self-power, NFC
AS-40E4-40VAH0Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: Self-power
AS-40E4-40VAH1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G | Control power: AC/DC 100-250 V
AS-40E4-40VAD1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VAJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext ZCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VAY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/Gext CT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VAO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: A (Ammeter), L/S/I/G + NCT + Modbus | Control power: AC/DC 100-250 V
AS-40E4-40VPS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V
AS-40E4-40VPJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V
AS-40E4-40VPY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V
AS-40E4-40VPO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: P (Power meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V
AS-40E4-40VSS1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + PTA | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VSJ1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext ZCT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VSY1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/Gext CT | Control power: AC/DC 100-250 V, BT/NFC
AS-40E4-40VSO1Frame: AS-40E, 4000AF | Rated current In: 4000 A | Poles: 4P | Mounting: Fixed, vertical busbar (V) | Trip relay: S (Supreme meter), L/S/I/G + NCT | Control power: AC/DC 100-250 V, BT/NFC