Skip to product information
1 of 1

LS Electric Susol Compact ACB AN/AH/AR (800-1600AF, 400-1600 A)

LS Electric Susol Compact ACB AN/AH/AR (800-1600AF, 400-1600 A)

LS Electric Susol Compact air circuit breakers AN, AH (Category B) and AR (Category A, current-limiting), 800-1600AF, 400-1600 A, fixed or draw-out, 3P/4P.

Key features

  • Approx. 55% smaller than conventional ACBs: 256 mm (3P) / 326 mm (4P) wide, 364 mm high
  • AN 42 kA and AH 50 kA at 690V (Ics = 100% Icu); AR Category A 150 kA at 415V
  • Rating plug changes rated current without replacing CTs (800AF: 400-800 A, 1600AF: 800-1600 A)
  • N, A, P and S type digital trip relays (L/S/I/G, metering, Modbus/Profibus communication)
  • Draw-out (auto/manual connect cradle) or fixed with H/V/M/N/P terminals; Z/R/T/X via adaptor kits
  • N-pole rated 100%; wide range of control voltages and internal accessories

Specifications

Rated operational voltage (Ue) AC 690 V (AR: 500 V)
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Service breaking capacity (Ics) 100% Icu
Short-time withstand (Icw) AN 42/25 kA, AH 50/30 kA (1 s/3 s); AR 10 kA
Mechanical endurance Cat. B 12,500 / Cat. A 5,000 operations
Dimensions (draw-out, 3P/4P) W 256/326 x D 274.5 x H 364.3 mm
Order suffix (specify separately) Motor/closing/trip voltage, aux. contacts, OCR type, UVT, options
Standards IEC 60947-2, GB 14048.2
Source LS Electric Susol Compact ACB catalog C06001-04 (2022-01), p. 5, 8-9, 14-15, 22-23
AN-08C3-00A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-00J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-00H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-00V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-00M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-00N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-00P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-00A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-00J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-00H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-00V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-00M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-00N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-00P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-00A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-00J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-00H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-00V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-00M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-00N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-00P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-00A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-00J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-00H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-00V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-00M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-00N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-00P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C3-04A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-04J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-04H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-04V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-04M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-04N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-04P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-04A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-04J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-04H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-04V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-04M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-04N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-04P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-04A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-04J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-04H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-04V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-04M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-04N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-04P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-04A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-04J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-04H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-04V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-04M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-04N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-04P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C3-06A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-06J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-06H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-06V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-06M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-06N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-06P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-06A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-06J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-06H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-06V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-06M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-06N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-06P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-06A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-06J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-06H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-06V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-06M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-06N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-06P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-06A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-06J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-06H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-06V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-06M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-06N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-06P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C3-08A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-08J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-08H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-08V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-08M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-08N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-08P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-08A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-08J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-08H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-08V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-08M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-08N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-08P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-08A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-08J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-08H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-08V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-08M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-08N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-08P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-08A Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-08J Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-08H Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-08V Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-08M Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-08N Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-08P Model: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-00A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-00J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-00H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-00V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-00M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-00N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-00P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-00A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-00J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-00H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-00V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-00M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-00N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-00P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-00A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-00J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-00H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-00V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-00M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-00N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-00P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-00A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-00J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-00H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-00V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-00M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-00N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-00P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-08A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-08J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-08H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-08V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-08M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-08N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-08P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-08A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-08J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-08H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-08V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-08M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-08N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-08P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-08A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-08J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-08H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-08V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-08M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-08N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-08P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-08A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-08J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-08H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-08V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-08M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-08N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-08P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-10A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-10J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-10H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-10V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-10M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-10N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-10P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-10A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-10J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-10H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-10V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-10M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-10N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-10P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-10A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-10J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-10H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-10V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-10M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-10N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-10P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-10A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-10J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-10H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-10V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-10M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-10N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-10P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-13A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-13J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-13H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-13V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-13M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-13N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-13P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-13A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-13J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-13H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-13V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-13M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-13N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-13P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-13A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-13J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-13H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-13V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-13M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-13N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-13P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-13A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-13J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-13H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-13V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-13M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-13N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-13P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-16A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-16J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-16H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-16V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-16M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-16N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-16P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-16A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-16J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-16H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-16V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-16M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-16N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-16P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-16A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-16J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-16H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-16V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-16M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-16N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-16P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-16A Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-16J Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-16H Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-16V Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-16M Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-16N Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-16P Model: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-00A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-00J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-00H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-00V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-00M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-00N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-00P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-00A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-00J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-00H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-00V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-00M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-00N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-00P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-00A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-00J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-00H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-00V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-00M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-00N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-00P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-00A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-00J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-00H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-00V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-00M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-00N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-00P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-04A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-04J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-04H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-04V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-04M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-04N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-04P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-04A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-04J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-04H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-04V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-04M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-04N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-04P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-04A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-04J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-04H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-04V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-04M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-04N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-04P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-04A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-04J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-04H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-04V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-04M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-04N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-04P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-06A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-06J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-06H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-06V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-06M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-06N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-06P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-06A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-06J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-06H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-06V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-06M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-06N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-06P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-06A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-06J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-06H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-06V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-06M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-06N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-06P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-06A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-06J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-06H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-06V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-06M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-06N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-06P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-08A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-08J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-08H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-08V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-08M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-08N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-08P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-08A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-08J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-08H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-08V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-08M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-08N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-08P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-08A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-08J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-08H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-08V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-08M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-08N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-08P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-08A Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-08J Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-08H Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-08V Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-08M Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-08N Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-08P Model: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-00A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-00J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-00H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-00V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-00M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-00N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-00P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-00A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-00J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-00H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-00V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-00M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-00N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-00P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-00A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-00J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-00H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-00V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-00M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-00N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-00P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-00A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-00J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-00H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-00V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-00M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-00N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-00P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-08A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-08J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-08H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-08V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-08M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-08N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-08P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-08A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-08J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-08H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-08V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-08M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-08N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-08P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-08A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-08J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-08H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-08V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-08M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-08N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-08P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-08A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-08J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-08H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-08V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-08M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-08N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-08P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-10A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-10J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-10H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-10V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-10M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-10N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-10P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-10A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-10J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-10H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-10V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-10M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-10N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-10P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-10A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-10J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-10H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-10V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-10M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-10N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-10P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-10A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-10J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-10H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-10V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-10M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-10N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-10P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-13A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-13J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-13H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-13V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-13M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-13N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-13P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-13A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-13J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-13H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-13V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-13M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-13N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-13P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-13A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-13J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-13H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-13V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-13M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-13N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-13P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-13A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-13J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-13H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-13V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-13M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-13N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-13P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-16A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-16J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-16H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-16V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-16M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-16N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-16P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-16A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-16J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-16H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-16V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-16M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-16N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-16P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-16A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-16J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-16H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-16V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-16M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-16N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-16P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-16A Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-16J Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-16H Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-16V Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-16M Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-16N Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-16P Model: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-00A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-00J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-00H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-00V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-00M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-00N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-00P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-00A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-00J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-00H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-00V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-00M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-00N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-00P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-00A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-00J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-00H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-00V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-00M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-00N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-00P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-00A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-00J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-00H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-00V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-00M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-00N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-00P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-04A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-04J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-04H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-04V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-04M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-04N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-04P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-04A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-04J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-04H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-04V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-04M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-04N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-04P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-04A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-04J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-04H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-04V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-04M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-04N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-04P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-04A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-04J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-04H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-04V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-04M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-04N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-04P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-06A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-06J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-06H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-06V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-06M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-06N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-06P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-06A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-06J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-06H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-06V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-06M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-06N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-06P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-06A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-06J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-06H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-06V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-06M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-06N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-06P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-06A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-06J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-06H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-06V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-06M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-06N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-06P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-08A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-08J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-08H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-08V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-08M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-08N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-08P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-08A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-08J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-08H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-08V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-08M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-08N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-08P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-08A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-08J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-08H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-08V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-08M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-08N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-08P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-08A Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-08J Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-08H Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-08V Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-08M Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-08N Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-08P Model: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C3-00A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C3-00J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C3-00H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C3-00V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C3-00M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C3-00N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C3-00P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V3-00A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V3-00J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V3-00H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V3-00V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V3-00M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V3-00N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V3-00P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C4-00A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C4-00J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C4-00H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C4-00V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C4-00M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C4-00N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C4-00P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V4-00A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V4-00J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V4-00H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V4-00V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V4-00M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V4-00N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V4-00P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C3-08A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C3-08J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C3-08H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C3-08V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C3-08M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C3-08N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C3-08P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V3-08A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V3-08J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V3-08H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V3-08V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V3-08M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V3-08N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V3-08P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C4-08A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C4-08J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C4-08H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C4-08V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C4-08M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C4-08N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C4-08P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V4-08A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V4-08J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V4-08H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V4-08V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V4-08M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V4-08N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V4-08P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C3-10A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C3-10J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C3-10H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C3-10V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C3-10M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C3-10N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C3-10P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V3-10A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V3-10J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V3-10H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V3-10V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V3-10M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V3-10N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V3-10P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C4-10A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C4-10J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C4-10H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C4-10V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C4-10M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C4-10N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C4-10P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V4-10A Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V4-10J Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V4-10H Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V4-10V Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V4-10M Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V4-10N Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V4-10P Model: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
Air Circuit BreakersLS Electric
700 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric Susol Compact ACB AN/AH/AR (800-1600AF, 400-1600 A)

Brand LS Electric·Air Circuit Breakers

Available part numbers (700)

AN-08C3-00A, AN-08C3-00J, AN-08C3-00H, AN-08C3-00V, AN-08C3-00M, AN-08C3-00N, AN-08C3-00P, AN-08V3-00A, AN-08V3-00J, AN-08V3-00H + 690 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
AN-08C3-00AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-00JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-00HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-00VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-00MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-00NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-00PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-00AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-00JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-00HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-00VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-00MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-00NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-00PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-00AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-00JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-00HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-00VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-00MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-00NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-00PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-00AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-00JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-00HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-00VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-00MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-00NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-00PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C3-04AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-04JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-04HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-04VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-04MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-04NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-04PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-04AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-04JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-04HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-04VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-04MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-04NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-04PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-04AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-04JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-04HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-04VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-04MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-04NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-04PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-04AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-04JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-04HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-04VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-04MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-04NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-04PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C3-06AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-06JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-06HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-06VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-06MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-06NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-06PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-06AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-06JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-06HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-06VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-06MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-06NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-06PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-06AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-06JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-06HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-06VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-06MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-06NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-06PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-06AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-06JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-06HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-06VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-06MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-06NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-06PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C3-08AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C3-08JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C3-08HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C3-08VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C3-08MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C3-08NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C3-08PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V3-08AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V3-08JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V3-08HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V3-08VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V3-08MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V3-08NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V3-08PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-08C4-08AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-08C4-08JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-08C4-08HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-08C4-08VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-08C4-08MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-08C4-08NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-08C4-08PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-08V4-08AModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-08V4-08JModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-08V4-08HModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-08V4-08VModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-08V4-08MModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-08V4-08NModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-08V4-08PModel: AN-08C (800AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-00AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-00JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-00HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-00VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-00MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-00NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-00PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-00AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-00JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-00HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-00VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-00MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-00NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-00PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-00AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-00JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-00HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-00VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-00MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-00NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-00PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-00AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-00JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-00HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-00VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-00MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-00NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-00PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-08AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-08JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-08HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-08VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-08MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-08NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-08PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-08AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-08JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-08HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-08VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-08MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-08NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-08PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-08AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-08JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-08HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-08VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-08MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-08NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-08PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-08AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-08JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-08HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-08VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-08MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-08NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-08PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-10AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-10JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-10HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-10VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-10MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-10NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-10PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-10AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-10JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-10HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-10VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-10MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-10NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-10PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-10AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-10JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-10HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-10VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-10MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-10NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-10PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-10AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-10JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-10HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-10VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-10MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-10NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-10PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-13AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-13JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-13HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-13VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-13MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-13NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-13PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-13AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-13JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-13HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-13VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-13MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-13NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-13PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-13AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-13JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-13HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-13VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-13MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-13NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-13PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-13AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-13JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-13HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-13VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-13MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-13NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-13PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C3-16AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C3-16JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C3-16HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C3-16VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C3-16MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C3-16NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C3-16PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V3-16AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V3-16JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V3-16HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V3-16VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V3-16MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V3-16NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V3-16PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AN-16C4-16AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AN-16C4-16JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AN-16C4-16HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AN-16C4-16VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AN-16C4-16MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AN-16C4-16NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AN-16C4-16PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AN-16V4-16AModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AN-16V4-16JModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AN-16V4-16HModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AN-16V4-16VModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AN-16V4-16MModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AN-16V4-16NModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AN-16V4-16PModel: AN-16C (1600AF) | Breaking: Cat. B, Icu 42 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-00AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-00JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-00HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-00VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-00MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-00NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-00PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-00AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-00JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-00HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-00VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-00MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-00NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-00PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-00AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-00JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-00HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-00VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-00MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-00NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-00PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-00AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-00JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-00HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-00VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-00MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-00NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-00PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-04AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-04JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-04HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-04VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-04MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-04NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-04PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-04AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-04JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-04HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-04VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-04MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-04NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-04PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-04AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-04JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-04HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-04VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-04MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-04NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-04PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-04AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-04JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-04HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-04VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-04MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-04NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-04PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-06AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-06JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-06HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-06VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-06MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-06NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-06PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-06AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-06JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-06HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-06VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-06MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-06NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-06PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-06AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-06JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-06HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-06VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-06MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-06NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-06PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-06AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-06JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-06HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-06VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-06MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-06NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-06PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C3-08AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C3-08JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C3-08HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C3-08VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C3-08MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C3-08NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C3-08PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V3-08AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V3-08JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V3-08HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V3-08VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V3-08MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V3-08NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V3-08PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-08C4-08AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-08C4-08JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-08C4-08HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-08C4-08VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-08C4-08MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-08C4-08NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-08C4-08PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-08V4-08AModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-08V4-08JModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-08V4-08HModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-08V4-08VModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-08V4-08MModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-08V4-08NModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-08V4-08PModel: AH-08C (800AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-00AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-00JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-00HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-00VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-00MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-00NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-00PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-00AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-00JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-00HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-00VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-00MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-00NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-00PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-00AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-00JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-00HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-00VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-00MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-00NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-00PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-00AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-00JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-00HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-00VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-00MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-00NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-00PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-08AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-08JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-08HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-08VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-08MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-08NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-08PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-08AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-08JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-08HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-08VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-08MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-08NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-08PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-08AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-08JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-08HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-08VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-08MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-08NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-08PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-08AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-08JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-08HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-08VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-08MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-08NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-08PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-10AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-10JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-10HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-10VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-10MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-10NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-10PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-10AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-10JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-10HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-10VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-10MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-10NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-10PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-10AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-10JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-10HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-10VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-10MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-10NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-10PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-10AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-10JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-10HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-10VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-10MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-10NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-10PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-13AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-13JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-13HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-13VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-13MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-13NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-13PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-13AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-13JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-13HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-13VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-13MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-13NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-13PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-13AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-13JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-13HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-13VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-13MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-13NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-13PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-13AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-13JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-13HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-13VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-13MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-13NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-13PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1250 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C3-16AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C3-16JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C3-16HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C3-16VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C3-16MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C3-16NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C3-16PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V3-16AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V3-16JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V3-16HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V3-16VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V3-16MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V3-16NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V3-16PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AH-16C4-16AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AH-16C4-16JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AH-16C4-16HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AH-16C4-16VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AH-16C4-16MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AH-16C4-16NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AH-16C4-16PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AH-16V4-16AModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AH-16V4-16JModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AH-16V4-16HModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AH-16V4-16VModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AH-16V4-16MModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AH-16V4-16NModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AH-16V4-16PModel: AH-16C (1600AF) | Breaking: Cat. B, Icu 50 kA/690V | Rated current: 1600 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-00AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-00JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-00HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-00VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-00MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-00NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-00PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-00AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-00JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-00HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-00VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-00MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-00NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-00PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-00AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-00JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-00HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-00VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-00MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-00NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-00PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-00AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-00JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-00HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-00VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-00MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-00NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-00PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-04AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-04JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-04HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-04VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-04MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-04NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-04PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-04AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-04JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-04HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-04VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-04MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-04NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-04PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-04AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-04JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-04HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-04VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-04MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-04NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-04PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-04AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-04JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-04HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-04VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-04MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-04NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-04PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 400 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-06AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-06JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-06HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-06VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-06MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-06NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-06PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-06AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-06JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-06HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-06VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-06MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-06NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-06PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-06AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-06JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-06HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-06VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-06MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-06NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-06PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-06AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-06JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-06HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-06VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-06MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-06NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-06PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 630 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C3-08AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C3-08JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C3-08HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C3-08VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C3-08MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C3-08NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C3-08PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V3-08AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V3-08JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V3-08HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V3-08VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V3-08MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V3-08NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V3-08PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-08C4-08AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-08C4-08JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-08C4-08HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-08C4-08VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-08C4-08MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-08C4-08NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-08C4-08PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-08V4-08AModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-08V4-08JModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-08V4-08HModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-08V4-08VModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-08V4-08MModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-08V4-08NModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-08V4-08PModel: AR-08C (800AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C3-00AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C3-00JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C3-00HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C3-00VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C3-00MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C3-00NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C3-00PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V3-00AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V3-00JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V3-00HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V3-00VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V3-00MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V3-00NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V3-00PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C4-00AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C4-00JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C4-00HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C4-00VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C4-00MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C4-00NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C4-00PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V4-00AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V4-00JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V4-00HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V4-00VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V4-00MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V4-00NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V4-00PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: No OCR & CT (00) | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C3-08AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C3-08JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C3-08HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C3-08VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C3-08MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C3-08NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C3-08PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V3-08AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V3-08JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V3-08HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V3-08VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V3-08MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V3-08NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V3-08PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C4-08AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C4-08JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C4-08HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C4-08VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C4-08MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C4-08NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C4-08PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V4-08AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V4-08JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V4-08HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V4-08VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V4-08MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V4-08NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V4-08PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 800 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C3-10AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C3-10JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C3-10HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C3-10VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C3-10MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C3-10NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C3-10PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V3-10AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V3-10JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V3-10HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V3-10VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V3-10MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V3-10NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V3-10PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 3P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals
AR-10C4-10AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, auto-connect cradle
AR-10C4-10JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Draw-out, manual-connect cradle
AR-10C4-10HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, horizontal top/bottom
AR-10C4-10VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, vertical top/bottom
AR-10C4-10MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top horiz./bottom vert.
AR-10C4-10NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, top vert./bottom horiz.
AR-10C4-10PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Standard (N)RST | Mounting: Fixed, front (flat) terminals
AR-10V4-10AModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, auto-connect cradle
AR-10V4-10JModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Draw-out, manual-connect cradle
AR-10V4-10HModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, horizontal top/bottom
AR-10V4-10VModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, vertical top/bottom
AR-10V4-10MModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top horiz./bottom vert.
AR-10V4-10NModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, top vert./bottom horiz.
AR-10V4-10PModel: AR-10C (1000AF) | Breaking: Cat. A, Icu 150 kA/415V | Rated current: 1000 A | Poles: 4P | Phase sequence: Reverse RST(N) | Mounting: Fixed, front (flat) terminals

Need a different model, or a part not listed here? Send us your parts list →