Skip to product information
1 of 1

LS Electric Susol UTD UL DC 1500 V MCCB (40-550 A, 4P)

LS Electric Susol UTD UL DC 1500 V MCCB (40-550 A, 4P)

LS Electric Susol UTD250, UTD400 and UTD600 UL-listed 1500 Vdc molded case circuit breakers, 40-550 A, 4 poles, for photovoltaic (UL489B) and battery/DC distribution (UL489) systems, dual certified to IEC 60947-2.

Key features

  • Maximum voltage DC 1500 V; UL interrupting rating at nominal 1250 Vdc: E/ET 20 kA, N/NT 50 kA, H/HT 65 kA
  • IEC 60947-2 Icu at 1500 Vdc: E 20 kA, N 40 kA, H 50 kA; T suffix = 100% rated, without = 80% rated
  • UL489 (ULF) ratings at 40 C for BPS use; UL489B (ULB) ratings at 50 C for PV use
  • FTU fixed or FMU adjustable thermal, fixed magnetic trip units
  • Compact frames: UTD250 140 x 200 x 92 mm, UTD400 186.5 x 290 x 110 mm, UTD600 186.5 x 340 x 110 mm
  • Ordering format: UTD + AF + type + trip unit + In + 4P + standard (e.g. UTD600-ET-FTU-550A-4P-ULF)

Specifications

Frame size 250 / 400 / 600 AF
Poles 4P
Rated operational voltage DC 1500 V
Rated insulation voltage (Ui) DC 1500 V
Rated impulse voltage (Uimp) 8 kV
Utilization category A
Weight UTD250 2.76 kg, UTD400 6.99 kg, UTD600 7 kg
Standards UL 489, UL 489B, CSA, IEC 60947-2
Source LS Electric Susol UL DC MCCB leaflet C010I1-04 (2024-03), p. 2-3
UTD250-E-FTU-60A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-80A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-100A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-150A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-200A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-250A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-60A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-80A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-100A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-150A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-200A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-250A-4P-ULF Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-40A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-60A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-80A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-100A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-150A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-200A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-60A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-80A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-100A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-150A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-200A-4P-ULB Frame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-60A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-80A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-100A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-150A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-200A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-250A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-60A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-80A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-100A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-150A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-200A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-250A-4P-ULF Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-40A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-60A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-80A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-100A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-150A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-200A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-60A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-80A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-100A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-150A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-200A-4P-ULB Frame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-60A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-80A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-100A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-150A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-200A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-250A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-60A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-80A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-100A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-150A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-200A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-250A-4P-ULF Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-40A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-60A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-80A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-100A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-150A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-200A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-60A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-80A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-100A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-150A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-200A-4P-ULB Frame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-60A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-80A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-100A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-150A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-200A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-250A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-60A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-80A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-100A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-150A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-200A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-250A-4P-ULF Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-40A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-60A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-80A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-100A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-150A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-200A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-60A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-80A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-100A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-150A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-200A-4P-ULB Frame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-60A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-80A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-100A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-150A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-200A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-250A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-60A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-80A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-100A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-150A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-200A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-250A-4P-ULF Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-40A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-60A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-80A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-100A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-150A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-200A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-60A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-80A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-100A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-150A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-200A-4P-ULB Frame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-60A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-80A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-100A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-150A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-200A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-250A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-60A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-80A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-100A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-150A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-200A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-250A-4P-ULF Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-40A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-60A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-80A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-100A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-150A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-200A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-60A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-80A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-100A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-150A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-200A-4P-ULB Frame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD400-E-FTU-275A-4P-ULF Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FTU-300A-4P-ULF Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FTU-400A-4P-ULF Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FMU-275A-4P-ULF Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FMU-300A-4P-ULF Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FMU-400A-4P-ULF Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FTU-250A-4P-ULB Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-E-FTU-275A-4P-ULB Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-E-FMU-275A-4P-ULB Frame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-ET-FTU-275A-4P-ULF Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FTU-300A-4P-ULF Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FTU-400A-4P-ULF Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FMU-275A-4P-ULF Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FMU-300A-4P-ULF Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FMU-400A-4P-ULF Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FTU-250A-4P-ULB Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-ET-FTU-275A-4P-ULB Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-ET-FMU-275A-4P-ULB Frame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-N-FTU-275A-4P-ULF Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FTU-300A-4P-ULF Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FTU-400A-4P-ULF Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FMU-275A-4P-ULF Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FMU-300A-4P-ULF Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FMU-400A-4P-ULF Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FTU-250A-4P-ULB Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-N-FTU-275A-4P-ULB Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-N-FMU-275A-4P-ULB Frame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-NT-FTU-275A-4P-ULF Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FTU-300A-4P-ULF Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FTU-400A-4P-ULF Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FMU-275A-4P-ULF Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FMU-300A-4P-ULF Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FMU-400A-4P-ULF Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FTU-250A-4P-ULB Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-NT-FTU-275A-4P-ULB Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-NT-FMU-275A-4P-ULB Frame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-H-FTU-275A-4P-ULF Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FTU-300A-4P-ULF Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FTU-400A-4P-ULF Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FMU-275A-4P-ULF Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FMU-300A-4P-ULF Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FMU-400A-4P-ULF Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FTU-250A-4P-ULB Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-H-FTU-275A-4P-ULB Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-H-FMU-275A-4P-ULB Frame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-HT-FTU-275A-4P-ULF Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FTU-300A-4P-ULF Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FTU-400A-4P-ULF Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FMU-275A-4P-ULF Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FMU-300A-4P-ULF Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FMU-400A-4P-ULF Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FTU-250A-4P-ULB Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-HT-FTU-275A-4P-ULB Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-HT-FMU-275A-4P-ULB Frame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD600-E-FTU-450A-4P-ULF Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FTU-500A-4P-ULF Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FTU-550A-4P-ULF Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FMU-450A-4P-ULF Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FMU-500A-4P-ULF Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FMU-550A-4P-ULF Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FTU-300A-4P-ULB Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-E-FTU-400A-4P-ULB Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-E-FTU-450A-4P-ULB Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-E-FMU-300A-4P-ULB Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-E-FMU-400A-4P-ULB Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-E-FMU-450A-4P-ULB Frame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FTU-450A-4P-ULF Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FTU-500A-4P-ULF Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FTU-550A-4P-ULF Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FMU-450A-4P-ULF Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FMU-500A-4P-ULF Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FMU-550A-4P-ULF Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FTU-300A-4P-ULB Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FTU-400A-4P-ULB Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FTU-450A-4P-ULB Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FMU-300A-4P-ULB Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FMU-400A-4P-ULB Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FMU-450A-4P-ULB Frame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-N-FTU-450A-4P-ULF Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FTU-500A-4P-ULF Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FTU-550A-4P-ULF Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FMU-450A-4P-ULF Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FMU-500A-4P-ULF Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FMU-550A-4P-ULF Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FTU-300A-4P-ULB Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-N-FTU-400A-4P-ULB Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-N-FTU-450A-4P-ULB Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-N-FMU-300A-4P-ULB Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-N-FMU-400A-4P-ULB Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-N-FMU-450A-4P-ULB Frame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FTU-450A-4P-ULF Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FTU-500A-4P-ULF Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FTU-550A-4P-ULF Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FMU-450A-4P-ULF Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FMU-500A-4P-ULF Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FMU-550A-4P-ULF Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FTU-300A-4P-ULB Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FTU-400A-4P-ULB Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FTU-450A-4P-ULB Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FMU-300A-4P-ULB Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FMU-400A-4P-ULB Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FMU-450A-4P-ULB Frame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-H-FTU-450A-4P-ULF Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FTU-500A-4P-ULF Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FTU-550A-4P-ULF Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FMU-450A-4P-ULF Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FMU-500A-4P-ULF Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FMU-550A-4P-ULF Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FTU-300A-4P-ULB Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-H-FTU-400A-4P-ULB Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-H-FTU-450A-4P-ULB Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-H-FMU-300A-4P-ULB Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-H-FMU-400A-4P-ULB Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-H-FMU-450A-4P-ULB Frame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FTU-450A-4P-ULF Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FTU-500A-4P-ULF Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FTU-550A-4P-ULF Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FMU-450A-4P-ULF Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FMU-500A-4P-ULF Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FMU-550A-4P-ULF Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FTU-300A-4P-ULB Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FTU-400A-4P-ULB Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FTU-450A-4P-ULB Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FMU-300A-4P-ULB Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FMU-400A-4P-ULB Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FMU-450A-4P-ULB Frame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
Molded Case Circuit BreakersLS Electric
264 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric Susol UTD UL DC 1500 V MCCB (40-550 A, 4P)

Brand LS Electric·Molded Case Circuit Breakers

Available part numbers (264)

UTD250-E-FTU-60A-4P-ULF, UTD250-E-FTU-80A-4P-ULF, UTD250-E-FTU-100A-4P-ULF, UTD250-E-FTU-150A-4P-ULF, UTD250-E-FTU-200A-4P-ULF, UTD250-E-FTU-250A-4P-ULF, UTD250-E-FMU-60A-4P-ULF, UTD250-E-FMU-80A-4P-ULF, UTD250-E-FMU-100A-4P-ULF, UTD250-E-FMU-150A-4P-ULF + 254 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
UTD250-E-FTU-60A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-80A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-100A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-150A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-200A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-250A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-60A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-80A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-100A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-150A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-200A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FMU-250A-4P-ULFFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-E-FTU-40A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-60A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-80A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-100A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-150A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-E-FTU-200A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-60A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-80A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-100A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-150A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-E-FMU-200A-4P-ULBFrame: UTD250 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-60A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-80A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-100A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-150A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-200A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-250A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-60A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-80A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-100A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-150A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-200A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FMU-250A-4P-ULFFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-ET-FTU-40A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-60A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-80A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-100A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-150A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FTU-200A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-60A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-80A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-100A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-150A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-ET-FMU-200A-4P-ULBFrame: UTD250 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-60A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-80A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-100A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-150A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-200A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-250A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-60A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-80A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-100A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-150A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-200A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FMU-250A-4P-ULFFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-N-FTU-40A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-60A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-80A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-100A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-150A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-N-FTU-200A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-60A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-80A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-100A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-150A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-N-FMU-200A-4P-ULBFrame: UTD250 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-60A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-80A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-100A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-150A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-200A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-250A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-60A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-80A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-100A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-150A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-200A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FMU-250A-4P-ULFFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-NT-FTU-40A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-60A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-80A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-100A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-150A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FTU-200A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-60A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-80A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-100A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-150A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-NT-FMU-200A-4P-ULBFrame: UTD250 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-60A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-80A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-100A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-150A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-200A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-250A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-60A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-80A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-100A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-150A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-200A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FMU-250A-4P-ULFFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-H-FTU-40A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-60A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-80A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-100A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-150A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-H-FTU-200A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-60A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-80A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-100A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-150A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-H-FMU-200A-4P-ULBFrame: UTD250 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-60A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-80A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-100A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-150A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-200A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-250A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-60A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-80A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-100A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-150A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-200A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FMU-250A-4P-ULFFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)
UTD250-HT-FTU-40A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-60A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-80A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-100A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-150A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FTU-200A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-60A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-80A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-100A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-150A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)
UTD250-HT-FMU-200A-4P-ULBFrame: UTD250 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)
UTD400-E-FTU-275A-4P-ULFFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FTU-300A-4P-ULFFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FTU-400A-4P-ULFFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FMU-275A-4P-ULFFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FMU-300A-4P-ULFFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FMU-400A-4P-ULFFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-E-FTU-250A-4P-ULBFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-E-FTU-275A-4P-ULBFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-E-FMU-275A-4P-ULBFrame: UTD400 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-ET-FTU-275A-4P-ULFFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FTU-300A-4P-ULFFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FTU-400A-4P-ULFFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FMU-275A-4P-ULFFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FMU-300A-4P-ULFFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FMU-400A-4P-ULFFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-ET-FTU-250A-4P-ULBFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-ET-FTU-275A-4P-ULBFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-ET-FMU-275A-4P-ULBFrame: UTD400 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-N-FTU-275A-4P-ULFFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FTU-300A-4P-ULFFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FTU-400A-4P-ULFFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FMU-275A-4P-ULFFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FMU-300A-4P-ULFFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FMU-400A-4P-ULFFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-N-FTU-250A-4P-ULBFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-N-FTU-275A-4P-ULBFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-N-FMU-275A-4P-ULBFrame: UTD400 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-NT-FTU-275A-4P-ULFFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FTU-300A-4P-ULFFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FTU-400A-4P-ULFFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FMU-275A-4P-ULFFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FMU-300A-4P-ULFFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FMU-400A-4P-ULFFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-NT-FTU-250A-4P-ULBFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-NT-FTU-275A-4P-ULBFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-NT-FMU-275A-4P-ULBFrame: UTD400 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-H-FTU-275A-4P-ULFFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FTU-300A-4P-ULFFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FTU-400A-4P-ULFFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FMU-275A-4P-ULFFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FMU-300A-4P-ULFFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FMU-400A-4P-ULFFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-H-FTU-250A-4P-ULBFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-H-FTU-275A-4P-ULBFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-H-FMU-275A-4P-ULBFrame: UTD400 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-HT-FTU-275A-4P-ULFFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FTU-300A-4P-ULFFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FTU-400A-4P-ULFFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FMU-275A-4P-ULFFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FMU-300A-4P-ULFFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FMU-400A-4P-ULFFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)
UTD400-HT-FTU-250A-4P-ULBFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)
UTD400-HT-FTU-275A-4P-ULBFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD400-HT-FMU-275A-4P-ULBFrame: UTD400 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)
UTD600-E-FTU-450A-4P-ULFFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FTU-500A-4P-ULFFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FTU-550A-4P-ULFFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FMU-450A-4P-ULFFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FMU-500A-4P-ULFFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FMU-550A-4P-ULFFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-E-FTU-300A-4P-ULBFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-E-FTU-400A-4P-ULBFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-E-FTU-450A-4P-ULBFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-E-FMU-300A-4P-ULBFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-E-FMU-400A-4P-ULBFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-E-FMU-450A-4P-ULBFrame: UTD600 | Type: E, 80% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FTU-450A-4P-ULFFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FTU-500A-4P-ULFFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FTU-550A-4P-ULFFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FMU-450A-4P-ULFFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FMU-500A-4P-ULFFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FMU-550A-4P-ULFFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-ET-FTU-300A-4P-ULBFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FTU-400A-4P-ULBFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FTU-450A-4P-ULBFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FMU-300A-4P-ULBFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FMU-400A-4P-ULBFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-ET-FMU-450A-4P-ULBFrame: UTD600 | Type: ET, 100% rated, UL 20 kA / IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-N-FTU-450A-4P-ULFFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FTU-500A-4P-ULFFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FTU-550A-4P-ULFFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FMU-450A-4P-ULFFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FMU-500A-4P-ULFFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FMU-550A-4P-ULFFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-N-FTU-300A-4P-ULBFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-N-FTU-400A-4P-ULBFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-N-FTU-450A-4P-ULBFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-N-FMU-300A-4P-ULBFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-N-FMU-400A-4P-ULBFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-N-FMU-450A-4P-ULBFrame: UTD600 | Type: N, 80% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FTU-450A-4P-ULFFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FTU-500A-4P-ULFFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FTU-550A-4P-ULFFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FMU-450A-4P-ULFFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FMU-500A-4P-ULFFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FMU-550A-4P-ULFFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-NT-FTU-300A-4P-ULBFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FTU-400A-4P-ULBFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FTU-450A-4P-ULBFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FMU-300A-4P-ULBFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FMU-400A-4P-ULBFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-NT-FMU-450A-4P-ULBFrame: UTD600 | Type: NT, 100% rated, UL 50 kA / IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-H-FTU-450A-4P-ULFFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FTU-500A-4P-ULFFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FTU-550A-4P-ULFFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FMU-450A-4P-ULFFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FMU-500A-4P-ULFFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FMU-550A-4P-ULFFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-H-FTU-300A-4P-ULBFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-H-FTU-400A-4P-ULBFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-H-FTU-450A-4P-ULBFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-H-FMU-300A-4P-ULBFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-H-FMU-400A-4P-ULBFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-H-FMU-450A-4P-ULBFrame: UTD600 | Type: H, 80% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FTU-450A-4P-ULFFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FTU-500A-4P-ULFFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FTU-550A-4P-ULFFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FMU-450A-4P-ULFFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FMU-500A-4P-ULFFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FMU-550A-4P-ULFFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)
UTD600-HT-FTU-300A-4P-ULBFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FTU-400A-4P-ULBFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FTU-450A-4P-ULBFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FMU-300A-4P-ULBFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FMU-400A-4P-ULBFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)
UTD600-HT-FMU-450A-4P-ULBFrame: UTD600 | Type: HT, 100% rated, UL 65 kA / IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)

Need a different model, or a part not listed here? Send us your parts list →