LS Electric Susol UTS1200 UL 489 molded case circuit breakers carry a factory-fitted digital trip relay (OCR) in Normal, Ammeter, Power-meter or Super-meter versions for 800-1200 A feeders.

Key features

  • UL 489 listed 3P breaker, HACR rated, up to 600 Vac
  • Digital OCR with long-time, short-time, instantaneous and ground-fault protection
  • A/P/S relays add metering, fault recording, ZSI and Modbus RS-485 / Profibus-DP communication
  • P and S relays add voltage, frequency, power and (S) harmonic analysis
  • Self-powered or externally powered control circuit (AC/DC 100-250 V or DC 24-60 V)

Specifications

Frame size 1200 AF, 3P
Rated insulation voltage (Ui) AC 1000 V
Rated impulse voltage (Uimp) 8 kV
UL 489 interrupting rating (240/480/600 V) N 50/35/18, H 100/65/25, P 65/50/50, L 150/100/35 kA
IEC 60947-2 Icu (220-240/380-415 V) N 50/35, H 100/65, P 65/50, L 150/100 kA
Dimensions (W x H x D) 210 x 413 x 152.5 mm
OCR settings Ir 0.4-1.0 In, Isd 1.5-10 Ir, Ii 2-15 In, Ig 0.2-1 In
Standards UL 489, CSA C22.2 No.5, IEC 60947-2
Rated frequency AC 50/60 Hz
Source LS Electric Susol UL MCCB catalog C01081-17 (2026-07), p. 60-62, 66-74, 85
UTS1200-N-NG0-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-NT-NG0-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-H-NG0-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-HT-NG0-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-P-NG0-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-PT-NG0-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-L-NG0-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-LT-NG0-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-N-NG0-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-NT-NG0-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-H-NG0-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-HT-NG0-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-P-NG0-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-PT-NG0-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-L-NG0-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-LT-NG0-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-N-NG0-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-NT-NG0-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-H-NG0-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-HT-NG0-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-P-NG0-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-PT-NG0-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-L-NG0-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-LT-NG0-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-N-NG5-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-NT-NG5-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-H-NG5-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-HT-NG5-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-P-NG5-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-PT-NG5-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-L-NG5-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-LT-NG5-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-N-NG5-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-NT-NG5-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-H-NG5-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-HT-NG5-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-P-NG5-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-PT-NG5-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-L-NG5-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-LT-NG5-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-N-NG5-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-NT-NG5-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-H-NG5-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-HT-NG5-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-P-NG5-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-PT-NG5-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-L-NG5-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-LT-NG5-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-N-AG0-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-NT-AG0-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-H-AG0-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-HT-AG0-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-P-AG0-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-PT-AG0-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-L-AG0-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-LT-AG0-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-N-AG0-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AG0-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-H-AG0-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AG0-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-P-AG0-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AG0-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-L-AG0-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AG0-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-N-AG0-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AG0-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-H-AG0-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AG0-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-P-AG0-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AG0-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-L-AG0-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AG0-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-N-AG1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AG1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AG1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AG1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AG1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AG1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AG1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AG1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AG1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AG1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AG1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AG1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AG1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AG1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AG1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AG1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AG1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AG1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AG1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AG1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AG1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AG1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AG1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AG1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AG2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AG2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AG2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AG2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AG2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AG2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AG2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AG2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AG2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AG2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AG2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AG2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AG2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AG2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AG2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AG2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AG2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AG2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AG2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AG2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AG2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AG2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AG2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AG2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AG5-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-NT-AG5-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-H-AG5-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-HT-AG5-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-P-AG5-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-PT-AG5-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-L-AG5-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-LT-AG5-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-N-AG5-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AG5-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-H-AG5-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AG5-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-P-AG5-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AG5-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-L-AG5-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AG5-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-N-AG5-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AG5-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-H-AG5-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AG5-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-P-AG5-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AG5-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-L-AG5-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AG5-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-N-AG6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AG6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AG6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AG6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AG6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AG6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AG6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AG6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AG6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AG6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AG6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AG6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AG6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AG6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AG6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AG6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AG6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AG6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AG6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AG6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AG6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AG6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AG6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AG6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AG7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AG7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AG7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AG7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AG7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AG7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AG7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AG7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AG7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AG7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AG7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AG7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AG7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AG7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AG7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AG7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AG7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AG7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AG7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AG7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AG7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AG7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AG7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AG7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AE0-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-NT-AE0-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-H-AE0-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-HT-AE0-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-P-AE0-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-PT-AE0-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-L-AE0-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-LT-AE0-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-N-AE0-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AE0-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-H-AE0-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AE0-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-P-AE0-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AE0-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-L-AE0-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AE0-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-N-AE0-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AE0-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-H-AE0-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AE0-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-P-AE0-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AE0-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-L-AE0-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AE0-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-N-AE1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AE1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AE1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AE1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AE1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AE1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AE1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AE1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AE1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AE1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AE1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AE1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AE1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AE1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AE1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AE1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AE1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AE1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AE1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AE1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AE1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AE1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AE1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AE1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AE2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AE2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AE2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AE2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AE2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AE2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AE2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AE2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AE2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AE2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AE2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AE2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AE2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AE2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AE2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AE2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AE2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AE2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AE2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AE2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AE2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AE2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AE2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AE2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AE5-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-NT-AE5-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-H-AE5-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-HT-AE5-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-P-AE5-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-PT-AE5-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-L-AE5-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-LT-AE5-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-N-AE5-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AE5-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-H-AE5-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AE5-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-P-AE5-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AE5-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-L-AE5-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AE5-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-N-AE5-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AE5-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-H-AE5-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AE5-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-P-AE5-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AE5-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-L-AE5-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AE5-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-N-AE6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AE6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AE6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AE6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AE6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AE6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AE6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AE6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AE6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AE6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AE6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AE6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AE6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AE6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AE6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AE6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AE6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AE6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AE6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AE6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AE6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AE6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AE6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AE6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AE7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AE7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AE7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AE7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AE7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AE7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AE7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AE7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AE7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AE7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AE7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AE7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AE7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AE7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AE7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AE7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AE7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AE7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AE7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AE7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AE7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AE7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AE7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AE7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AC1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AC1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AC1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AC1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AC1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AC1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AC1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AC1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AC1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AC1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AC1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AC1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AC1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AC1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AC1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AC1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AC1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AC1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AC1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AC1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AC1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AC1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AC1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AC1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AC2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AC2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AC2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AC2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AC2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AC2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AC2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AC2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AC2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AC2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AC2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AC2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AC2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AC2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AC2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AC2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AC2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AC2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AC2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AC2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AC2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AC2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AC2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AC2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AC6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AC6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AC6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AC6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AC6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AC6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AC6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AC6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AC6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AC6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AC6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AC6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AC6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AC6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AC6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AC6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AC6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AC6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AC6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AC6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AC6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AC6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AC6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AC6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AC7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AC7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AC7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AC7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AC7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AC7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AC7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AC7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AC7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AC7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AC7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AC7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AC7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AC7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AC7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AC7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AC7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AC7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AC7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AC7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AC7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AC7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AC7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AC7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AX1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AX1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AX1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AX1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AX1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AX1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AX1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AX1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AX1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AX1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AX1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AX1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AX1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AX1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AX1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AX1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AX1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AX1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AX1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AX1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AX1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AX1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AX1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AX1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AX2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AX2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AX2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AX2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AX2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AX2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AX2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AX2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AX2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AX2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AX2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AX2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AX2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AX2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AX2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AX2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AX2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AX2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AX2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AX2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AX2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AX2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AX2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AX2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AX6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AX6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AX6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AX6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AX6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AX6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AX6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AX6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AX6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AX6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AX6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AX6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AX6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AX6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AX6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AX6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AX6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AX6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AX6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AX6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AX6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AX6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AX6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AX6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AX7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AX7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AX7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AX7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AX7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AX7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AX7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AX7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AX7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AX7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AX7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AX7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AX7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AX7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AX7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AX7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AX7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AX7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AX7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AX7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AX7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AX7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AX7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AX7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PC1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PC1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PC1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PC1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PC1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PC1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PC1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PC1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PC1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PC1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PC1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PC1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PC1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PC1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PC1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PC1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PC1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PC1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PC1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PC1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PC1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PC1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PC1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PC1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PC2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PC2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PC2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PC2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PC2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PC2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PC2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PC2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PC2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PC2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PC2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PC2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PC2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PC2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PC2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PC2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PC2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PC2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PC2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PC2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PC2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PC2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PC2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PC2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PC6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PC6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PC6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PC6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PC6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PC6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PC6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PC6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PC6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PC6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PC6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PC6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PC6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PC6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PC6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PC6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PC6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PC6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PC6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PC6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PC6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PC6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PC6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PC6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PC7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PC7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PC7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PC7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PC7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PC7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PC7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PC7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PC7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PC7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PC7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PC7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PC7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PC7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PC7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PC7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PC7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PC7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PC7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PC7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PC7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PC7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PC7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PC7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PX1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PX1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PX1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PX1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PX1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PX1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PX1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PX1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PX1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PX1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PX1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PX1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PX1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PX1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PX1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PX1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PX1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PX1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PX1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PX1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PX1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PX1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PX1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PX1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PX2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PX2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PX2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PX2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PX2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PX2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PX2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PX2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PX2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PX2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PX2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PX2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PX2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PX2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PX2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PX2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PX2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PX2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PX2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PX2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PX2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PX2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PX2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PX2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PX6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PX6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PX6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PX6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PX6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PX6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PX6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PX6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PX6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PX6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PX6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PX6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PX6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PX6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PX6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PX6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PX6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PX6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PX6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PX6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PX6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PX6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PX6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PX6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PX7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PX7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PX7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PX7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PX7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PX7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PX7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PX7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PX7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PX7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PX7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PX7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PX7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PX7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PX7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PX7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PX7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PX7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PX7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PX7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PX7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PX7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PX7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PX7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SC1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SC1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SC1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SC1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SC1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SC1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SC1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SC1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SC1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SC1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SC1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SC1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SC1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SC1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SC1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SC1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SC1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SC1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SC1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SC1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SC1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SC1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SC1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SC1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SC2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SC2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SC2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SC2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SC2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SC2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SC2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SC2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SC2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SC2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SC2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SC2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SC2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SC2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SC2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SC2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SC2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SC2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SC2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SC2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SC2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SC2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SC2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SC2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SC6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SC6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SC6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SC6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SC6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SC6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SC6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SC6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SC6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SC6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SC6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SC6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SC6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SC6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SC6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SC6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SC6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SC6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SC6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SC6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SC6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SC6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SC6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SC6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SC7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SC7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SC7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SC7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SC7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SC7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SC7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SC7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SC7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SC7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SC7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SC7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SC7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SC7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SC7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SC7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SC7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SC7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SC7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SC7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SC7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SC7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SC7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SC7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SX1-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SX1-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SX1-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SX1-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SX1-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SX1-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SX1-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SX1-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SX1-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SX1-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SX1-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SX1-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SX1-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SX1-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SX1-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SX1-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SX1-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SX1-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SX1-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SX1-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SX1-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SX1-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SX1-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SX1-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SX2-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SX2-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SX2-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SX2-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SX2-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SX2-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SX2-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SX2-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SX2-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SX2-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SX2-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SX2-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SX2-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SX2-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SX2-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SX2-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SX2-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SX2-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SX2-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SX2-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SX2-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SX2-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SX2-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SX2-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SX6-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SX6-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SX6-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SX6-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SX6-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SX6-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SX6-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SX6-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SX6-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SX6-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SX6-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SX6-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SX6-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SX6-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SX6-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SX6-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SX6-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SX6-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SX6-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SX6-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SX6-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SX6-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SX6-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SX6-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SX7-800A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SX7-800A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SX7-800A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SX7-800A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SX7-800A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SX7-800A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SX7-800A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SX7-800A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SX7-1000A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SX7-1000A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SX7-1000A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SX7-1000A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SX7-1000A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SX7-1000A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SX7-1000A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SX7-1000A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SX7-1200A-3P-UL Type: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SX7-1200A-3P-UL Type: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SX7-1200A-3P-UL Type: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SX7-1200A-3P-UL Type: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SX7-1200A-3P-UL Type: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SX7-1200A-3P-UL Type: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SX7-1200A-3P-UL Type: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SX7-1200A-3P-UL Type: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
Molded Case Circuit BreakersLS Electric
912 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric Susol UTS1200 UL 489 MCCB (800-1200 A, digital OCR)

Brand LS Electric·Molded Case Circuit Breakers

Available part numbers (912)

UTS1200-N-NG0-800A-3P-UL, UTS1200-NT-NG0-800A-3P-UL, UTS1200-H-NG0-800A-3P-UL, UTS1200-HT-NG0-800A-3P-UL, UTS1200-P-NG0-800A-3P-UL, UTS1200-PT-NG0-800A-3P-UL, UTS1200-L-NG0-800A-3P-UL, UTS1200-LT-NG0-800A-3P-UL, UTS1200-N-NG0-1000A-3P-UL, UTS1200-NT-NG0-1000A-3P-UL + 902 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
UTS1200-N-NG0-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-NT-NG0-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-H-NG0-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-HT-NG0-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-P-NG0-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-PT-NG0-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-L-NG0-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-LT-NG0-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-N-NG0-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-NT-NG0-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-H-NG0-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-HT-NG0-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-P-NG0-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-PT-NG0-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-L-NG0-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-LT-NG0-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-N-NG0-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-NT-NG0-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-H-NG0-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-HT-NG0-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-P-NG0-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-PT-NG0-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-L-NG0-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-LT-NG0-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-N-NG5-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-NT-NG5-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-H-NG5-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-HT-NG5-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-P-NG5-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-PT-NG5-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-L-NG5-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-LT-NG5-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-N-NG5-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-NT-NG5-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-H-NG5-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-HT-NG5-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-P-NG5-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-PT-NG5-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-L-NG5-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-LT-NG5-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-N-NG5-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-NT-NG5-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-H-NG5-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-HT-NG5-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-P-NG5-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-PT-NG5-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-L-NG5-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-LT-NG5-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-N-AG0-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-NT-AG0-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-H-AG0-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-HT-AG0-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-P-AG0-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-PT-AG0-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-L-AG0-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-LT-AG0-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-N-AG0-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AG0-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-H-AG0-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AG0-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-P-AG0-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AG0-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-L-AG0-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AG0-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-N-AG0-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AG0-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-H-AG0-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AG0-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-P-AG0-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AG0-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-L-AG0-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AG0-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-N-AG1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AG1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AG1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AG1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AG1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AG1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AG1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AG1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AG1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AG1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AG1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AG1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AG1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AG1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AG1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AG1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AG1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AG1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AG1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AG1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AG1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AG1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AG1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AG1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AG2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AG2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AG2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AG2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AG2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AG2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AG2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AG2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AG2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AG2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AG2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AG2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AG2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AG2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AG2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AG2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AG2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AG2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AG2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AG2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AG2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AG2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AG2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AG2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AG5-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-NT-AG5-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-H-AG5-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-HT-AG5-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-P-AG5-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-PT-AG5-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-L-AG5-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-LT-AG5-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-N-AG5-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AG5-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-H-AG5-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AG5-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-P-AG5-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AG5-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-L-AG5-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AG5-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-N-AG5-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AG5-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-H-AG5-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AG5-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-P-AG5-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AG5-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-L-AG5-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AG5-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-N-AG6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AG6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AG6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AG6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AG6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AG6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AG6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AG6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AG6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AG6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AG6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AG6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AG6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AG6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AG6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AG6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AG6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AG6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AG6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AG6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AG6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AG6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AG6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AG6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AG7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AG7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AG7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AG7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AG7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AG7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AG7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AG7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AG7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AG7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AG7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AG7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AG7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AG7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AG7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AG7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AG7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AG7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AG7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AG7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AG7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AG7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AG7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AG7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AE0-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-NT-AE0-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-H-AE0-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-HT-AE0-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-P-AE0-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-PT-AE0-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-L-AE0-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-LT-AE0-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A
UTS1200-N-AE0-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AE0-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-H-AE0-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AE0-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-P-AE0-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AE0-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-L-AE0-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AE0-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1000 A
UTS1200-N-AE0-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AE0-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-H-AE0-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AE0-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-P-AE0-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AE0-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-L-AE0-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AE0-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 1200 A
UTS1200-N-AE1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AE1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AE1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AE1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AE1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AE1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AE1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AE1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AE1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AE1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AE1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AE1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AE1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AE1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AE1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AE1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AE1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AE1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AE1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AE1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AE1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AE1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AE1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AE1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AE2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AE2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AE2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AE2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AE2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AE2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AE2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AE2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AE2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AE2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AE2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AE2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AE2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AE2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AE2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AE2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AE2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AE2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AE2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AE2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AE2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AE2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AE2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AE2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AE5-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-NT-AE5-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-H-AE5-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-HT-AE5-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-P-AE5-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-PT-AE5-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-L-AE5-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-LT-AE5-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A
UTS1200-N-AE5-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AE5-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-H-AE5-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AE5-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-P-AE5-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AE5-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-L-AE5-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AE5-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1000 A
UTS1200-N-AE5-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AE5-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-H-AE5-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AE5-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-P-AE5-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AE5-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-L-AE5-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AE5-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 1200 A
UTS1200-N-AE6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AE6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AE6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AE6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AE6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AE6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AE6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AE6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AE6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AE6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AE6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AE6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AE6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AE6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AE6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AE6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AE6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AE6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AE6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AE6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AE6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AE6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AE6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AE6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AE7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AE7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AE7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AE7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AE7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AE7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AE7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AE7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AE7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AE7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AE7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AE7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AE7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AE7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AE7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AE7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AE7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AE7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AE7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AE7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AE7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AE7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AE7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AE7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: E - Ground fault/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AC1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AC1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AC1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AC1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AC1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AC1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AC1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AC1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AC1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AC1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AC1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AC1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AC1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AC1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AC1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AC1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AC1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AC1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AC1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AC1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AC1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AC1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AC1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AC1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AC2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AC2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AC2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AC2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AC2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AC2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AC2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AC2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AC2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AC2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AC2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AC2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AC2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AC2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AC2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AC2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AC2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AC2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AC2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AC2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AC2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AC2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AC2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AC2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AC6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AC6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AC6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AC6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AC6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AC6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AC6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AC6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AC6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AC6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AC6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AC6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AC6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AC6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AC6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AC6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AC6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AC6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AC6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AC6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AC6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AC6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AC6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AC6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AC7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AC7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AC7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AC7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AC7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AC7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AC7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AC7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AC7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AC7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AC7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AC7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AC7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AC7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AC7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AC7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AC7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AC7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AC7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AC7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AC7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AC7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AC7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AC7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AX1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AX1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AX1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AX1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AX1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AX1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AX1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AX1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AX1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AX1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AX1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AX1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AX1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AX1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AX1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AX1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AX1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AX1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AX1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AX1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AX1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AX1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AX1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AX1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AX2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-AX2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-AX2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-AX2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-AX2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-AX2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-AX2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-AX2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-AX2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-AX2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-AX2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-AX2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-AX2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-AX2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-AX2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-AX2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-AX2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-AX2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-AX2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-AX2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-AX2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-AX2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-AX2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-AX2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-AX6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AX6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AX6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AX6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AX6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AX6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AX6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AX6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AX6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AX6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AX6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AX6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AX6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AX6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AX6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AX6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AX6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AX6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AX6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AX6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AX6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AX6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AX6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AX6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-AX7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-AX7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-AX7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-AX7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-AX7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-AX7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-AX7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-AX7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-AX7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-AX7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-AX7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-AX7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-AX7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-AX7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-AX7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-AX7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-AX7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-AX7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-AX7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-AX7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-AX7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-AX7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-AX7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-AX7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PC1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PC1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PC1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PC1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PC1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PC1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PC1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PC1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PC1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PC1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PC1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PC1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PC1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PC1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PC1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PC1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PC1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PC1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PC1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PC1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PC1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PC1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PC1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PC1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PC2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PC2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PC2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PC2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PC2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PC2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PC2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PC2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PC2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PC2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PC2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PC2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PC2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PC2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PC2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PC2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PC2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PC2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PC2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PC2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PC2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PC2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PC2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PC2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PC6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PC6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PC6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PC6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PC6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PC6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PC6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PC6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PC6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PC6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PC6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PC6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PC6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PC6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PC6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PC6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PC6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PC6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PC6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PC6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PC6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PC6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PC6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PC6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PC7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PC7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PC7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PC7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PC7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PC7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PC7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PC7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PC7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PC7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PC7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PC7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PC7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PC7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PC7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PC7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PC7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PC7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PC7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PC7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PC7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PC7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PC7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PC7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PX1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PX1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PX1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PX1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PX1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PX1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PX1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PX1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PX1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PX1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PX1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PX1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PX1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PX1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PX1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PX1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PX1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PX1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PX1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PX1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PX1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PX1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PX1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PX1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PX2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-PX2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-PX2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-PX2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-PX2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-PX2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-PX2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-PX2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-PX2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-PX2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-PX2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-PX2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-PX2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-PX2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-PX2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-PX2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-PX2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-PX2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-PX2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-PX2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-PX2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-PX2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-PX2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-PX2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-PX6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PX6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PX6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PX6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PX6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PX6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PX6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PX6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PX6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PX6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PX6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PX6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PX6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PX6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PX6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PX6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PX6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PX6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PX6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PX6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PX6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PX6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PX6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PX6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-PX7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-PX7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-PX7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-PX7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-PX7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-PX7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-PX7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-PX7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-PX7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-PX7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-PX7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-PX7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-PX7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-PX7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-PX7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-PX7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-PX7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-PX7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-PX7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-PX7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-PX7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-PX7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-PX7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-PX7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SC1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SC1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SC1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SC1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SC1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SC1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SC1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SC1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SC1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SC1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SC1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SC1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SC1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SC1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SC1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SC1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SC1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SC1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SC1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SC1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SC1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SC1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SC1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SC1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SC2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SC2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SC2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SC2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SC2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SC2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SC2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SC2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SC2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SC2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SC2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SC2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SC2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SC2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SC2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SC2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SC2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SC2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SC2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SC2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SC2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SC2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SC2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SC2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SC6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SC6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SC6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SC6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SC6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SC6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SC6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SC6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SC6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SC6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SC6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SC6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SC6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SC6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SC6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SC6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SC6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SC6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SC6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SC6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SC6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SC6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SC6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SC6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SC7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SC7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SC7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SC7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SC7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SC7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SC7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SC7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SC7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SC7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SC7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SC7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SC7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SC7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SC7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SC7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SC7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SC7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SC7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SC7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SC7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SC7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SC7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SC7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SX1-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SX1-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SX1-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SX1-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SX1-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SX1-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SX1-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SX1-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SX1-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SX1-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SX1-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SX1-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SX1-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SX1-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SX1-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SX1-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SX1-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SX1-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SX1-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SX1-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SX1-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SX1-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SX1-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SX1-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 1 - AC/DC 100-250 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SX2-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-NT-SX2-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-H-SX2-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-HT-SX2-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-P-SX2-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-PT-SX2-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-L-SX2-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-LT-SX2-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A
UTS1200-N-SX2-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-NT-SX2-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-H-SX2-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-HT-SX2-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-P-SX2-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-PT-SX2-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-L-SX2-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-LT-SX2-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1000 A
UTS1200-N-SX2-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-NT-SX2-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-H-SX2-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-HT-SX2-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-P-SX2-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-PT-SX2-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-L-SX2-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-LT-SX2-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 1200 A
UTS1200-N-SX6-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SX6-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SX6-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SX6-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SX6-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SX6-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SX6-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SX6-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SX6-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SX6-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SX6-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SX6-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SX6-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SX6-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SX6-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SX6-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SX6-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SX6-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SX6-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SX6-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SX6-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SX6-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SX6-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SX6-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 6 - AC/DC 100-250 V, 50 Hz | Rated current In: 1200 A
UTS1200-N-SX7-800A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-NT-SX7-800A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-H-SX7-800A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-HT-SX7-800A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-P-SX7-800A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-PT-SX7-800A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-L-SX7-800A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-LT-SX7-800A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A
UTS1200-N-SX7-1000A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-NT-SX7-1000A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-H-SX7-1000A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-HT-SX7-1000A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-P-SX7-1000A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-PT-SX7-1000A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-L-SX7-1000A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-LT-SX7-1000A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1000 A
UTS1200-N-SX7-1200A-3P-ULType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-NT-SX7-1200A-3P-ULType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-H-SX7-1200A-3P-ULType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-HT-SX7-1200A-3P-ULType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-P-SX7-1200A-3P-ULType: P, 50 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-PT-SX7-1200A-3P-ULType: PT, 50 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-L-SX7-1200A-3P-ULType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A
UTS1200-LT-SX7-1200A-3P-ULType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection/comm.: X - Ground fault/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 1200 A

Need a different model, or a part not listed here? Send us your parts list →