Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| VC-03Z-42EED1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42EED2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42EED3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42EEA1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42EEA2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42EEA3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42LED1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42LED2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42LED3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42LEA1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42LEA2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-42LEA3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03Z-44EED1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44EED2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44EED3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44EEA1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44EEA2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44EEA3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44LED1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44LED2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44LED3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44LEA1 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44LEA2 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03Z-44LEA3 | Rated voltage: 3.6 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-42EED1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42EED2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42EED3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42EEA1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42EEA2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42EEA3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42LED1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42LED2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42LED3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42LEA1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42LEA2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-42LEA3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03D-44EED1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44EED2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44EED3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44EEA1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44EEA2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44EEA3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44LED1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44LED2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44LED3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44LEA1 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44LEA2 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03D-44LEA3 | Rated voltage: 3.6 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-42EED1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42EED2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42EED3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42EEA1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42EEA2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42EEA3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42LED1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42LED2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42LED3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42LEA1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42LEA2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-42LEA3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03G-44EED1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44EED2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44EED3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44EEA1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44EEA2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44EEA3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44LED1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44LED2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44LED3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44LEA1 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44LEA2 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03G-44LEA3 | Rated voltage: 3.6 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-42EED1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42EED2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42EED3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42EEA1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42EEA2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42EEA3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42LED1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42LED2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42LED3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42LEA1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42LEA2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-42LEA3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03F-44EED1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44EED2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44EED3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44EEA1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44EEA2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44EEA3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44LED1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44LED2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44LED3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44LEA1 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44LEA2 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03F-44LEA3 | Rated voltage: 3.6 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-42EED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42EED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42EED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42EEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42EEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42EEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42LED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42LED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42LED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42LEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42LEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-42LEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03K-44EED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44EED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44EED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44EEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44EEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44EEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44LED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44LED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44LED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44LEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44LEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03K-44LEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-42EED1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42EED2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42EED3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42EEA1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42EEA2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42EEA3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42LED1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42LED2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42LED3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42LEA1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42LEA2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-42LEA3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03B-44EED1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44EED2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44EED3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44EEA1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44EEA2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44EEA3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44LED1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44LED2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44LED3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44LEA1 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44LEA2 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03B-44LEA3 | Rated voltage: 3.6 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-42EED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42EED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42EED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42EEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42EEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42EEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42LED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42LED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42LED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42LEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42LEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-42LEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03P-44EED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44EED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44EED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44EEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44EEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44EEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44LED1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44LED2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44LED3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44LEA1 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44LEA2 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03P-44LEA3 | Rated voltage: 3.6 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-42EED1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42EED2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42EED3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42EEA1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42EEA2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42EEA3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42LED1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42LED2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42LED3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42LEA1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42LEA2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-42LEA3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 750 kW | ||
| VC-03T-44EED1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44EED2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44EED3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44EEA1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44EEA2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44EEA3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44LED1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44LED2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44LED3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44LEA1 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44LEA2 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-03T-44LEA3 | Rated voltage: 3.6 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42EED1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42EED2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42EED3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42EEA1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42EEA2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42EEA3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42LED1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42LED2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42LED3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42LEA1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42LEA2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-42LEA3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06Z-44EED1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44EED2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44EED3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44EEA1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44EEA2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44EEA3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44LED1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44LED2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44LED3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44LEA1 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44LEA2 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06Z-44LEA3 | Rated voltage: 7.2 kV | Connection type: Fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-42EED1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42EED2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42EED3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42EEA1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42EEA2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42EEA3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42LED1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42LED2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42LED3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42LEA1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42LEA2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-42LEA3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06D-44EED1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44EED2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44EED3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44EEA1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44EEA2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44EEA3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44LED1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44LED2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44LED3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44LEA1 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44LEA2 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06D-44LEA3 | Rated voltage: 7.2 kV | Connection type: Draw-out (lever) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-42EED1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42EED2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42EED3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42EEA1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42EEA2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42EEA3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42LED1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42LED2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42LED3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42LEA1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42LEA2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-42LEA3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06G-44EED1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44EED2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44EED3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44EEA1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44EEA2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44EEA3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44LED1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44LED2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44LED3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44LEA1 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44LEA2 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06G-44LEA3 | Rated voltage: 7.2 kV | Connection type: PF combination draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-42EED1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42EED2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42EED3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42EEA1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42EEA2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42EEA3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42LED1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42LED2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42LED3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42LEA1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42LEA2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-42LEA3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06F-44EED1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44EED2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44EED3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44EEA1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44EEA2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44EEA3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44LED1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44LED2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44LED3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44LEA1 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44LEA2 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06F-44LEA3 | Rated voltage: 7.2 kV | Connection type: PF combination fixed | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-42EED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42EED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42EED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42EEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42EEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42EEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42LED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42LED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42LED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42LEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42LEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-42LEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06K-44EED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44EED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44EED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44EEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44EEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44EEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44LED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44LED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44LED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44LEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44LEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06K-44LEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (screw) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-42EED1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42EED2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42EED3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42EEA1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42EEA2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42EEA3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42LED1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42LED2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42LED3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42LEA1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42LEA2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-42LEA3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06B-44EED1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44EED2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44EED3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44EEA1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44EEA2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44EEA3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44LED1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44LED2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44LED3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44LEA1 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44LEA2 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06B-44LEA3 | Rated voltage: 7.2 kV | Connection type: PF combination external draw-out | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-42EED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42EED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42EED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42EEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42EEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42EEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42LED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42LED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42LED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42LEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42LEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-42LEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06P-44EED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44EED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44EED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44EEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44EEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44EEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44LED1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44LED2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44LED3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44LEA1 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44LEA2 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06P-44LEA3 | Rated voltage: 7.2 kV | Connection type: External draw-out (P150 cradle) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-42EED1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42EED2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42EED3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42EEA1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42EEA2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42EEA3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42LED1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42LED2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42LED3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42LEA1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42LEA2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-42LEA3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 200 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 1,500 kW | ||
| VC-06T-44EED1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44EED2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44EED3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44EEA1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44EEA2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44EEA3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Continuous excitation | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44LED1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44LED2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44LED3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44LEA1 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44LEA2 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Max. motor (3-phase): 3,000 kW | ||
| VC-06T-44LEA3 | Rated voltage: 7.2 kV | Connection type: PF comb. external draw-out (P150) | Rated current: 400 A | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Max. motor (3-phase): 3,000 kW |
Need a different model, or a part not listed here? Send us your parts list →