Skip to product information
1 of 1

SMC AC30B-D F.R. Combination (Filter + Regulator)

SMC AC30B-D F.R. Combination (Filter + Regulator)

SMC modular F.R.L. combination for compressed air preparation.

Key features

  • Body size 30, port size: 1/4, 3/8
  • Constituent units: AF (filter, 5μm) + AR (regulator)
  • Setting pressure: 0.05–0.85 MPa (low-pressure 0.02–0.2 MPa available on request)
  • Max working pressure 1.0 MPa, proof pressure 1.5 MPa
  • Operating temperature: -5 to 60°C
  • Threads: Rc / NPT / G

Specifications

Body size 30
Combination type AC-B
Constituent units AF (filter, 5μm) + AR (regulator)
Setting pressure 0.05–0.85 MPa
Max working pressure 1.0 MPa
Proof pressure 1.5 MPa
Operating temperature -5 to 60°C
Spec Clean/Low-particle (-D)
AC30B-02-D Rc 1/4, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02E-D Rc 1/4, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02C-D Rc 1/4, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02CE-D Rc 1/4, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02D-D Rc 1/4, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02DE-D Rc 1/4, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03-D Rc 3/8, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03E-D Rc 3/8, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03C-D Rc 3/8, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03CE-D Rc 3/8, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03D-D Rc 3/8, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03DE-D Rc 3/8, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02-D NPT 1/4, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02E-D NPT 1/4, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02C-D NPT 1/4, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02CE-D NPT 1/4, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02D-D NPT 1/4, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02DE-D NPT 1/4, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03-D NPT 3/8, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03E-D NPT 3/8, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03C-D NPT 3/8, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03CE-D NPT 3/8, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03D-D NPT 3/8, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03DE-D NPT 3/8, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02-D G 1/4, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02E-D G 1/4, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02C-D G 1/4, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02CE-D G 1/4, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02D-D G 1/4, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02DE-D G 1/4, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03-D G 3/8, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03E-D G 3/8, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03C-D G 3/8, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03CE-D G 3/8, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03D-D G 3/8, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03DE-D G 3/8, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
FRL CombinationsSMC
36 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC AC30B-D F.R. Combination (Filter + Regulator)

Brand SMC·FRL Combinations

Available part numbers (36)

AC30B-02-D, AC30B-02E-D, AC30B-02C-D, AC30B-02CE-D, AC30B-02D-D, AC30B-02DE-D, AC30B-03-D, AC30B-03E-D, AC30B-03C-D, AC30B-03CE-D + 26 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
AC30B-02-DRc 1/4, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02E-DRc 1/4, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02C-DRc 1/4, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02CE-DRc 1/4, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02D-DRc 1/4, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-02DE-DRc 1/4, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03-DRc 3/8, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03E-DRc 3/8, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03C-DRc 3/8, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03CE-DRc 3/8, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03D-DRc 3/8, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-03DE-DRc 3/8, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: Rc | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02-DNPT 1/4, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02E-DNPT 1/4, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02C-DNPT 1/4, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02CE-DNPT 1/4, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02D-DNPT 1/4, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N02DE-DNPT 1/4, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03-DNPT 3/8, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03E-DNPT 3/8, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03C-DNPT 3/8, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03CE-DNPT 3/8, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03D-DNPT 3/8, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-N03DE-DNPT 3/8, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: NPT | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02-DG 1/4, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02E-DG 1/4, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02C-DG 1/4, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02CE-DG 1/4, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02D-DG 1/4, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F02DE-DG 1/4, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 1/4 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03-DG 3/8, Manual drain | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03E-DG 3/8, Manual drain, Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Manual drain | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03C-DG 3/8, Auto drain N.C. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03CE-DG 3/8, Auto drain N.C., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.C. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03D-DG 3/8, Auto drain N.O. | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: No pressure gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)
AC30B-F03DE-DG 3/8, Auto drain N.O., Square embedded gauge | Body size: 30 | Combination type: AC-B | Constituent units: AF (filter, 5μm) + AR (regulator) | Thread: G | Port size: 3/8 | Auto drain: Auto drain N.O. | Pressure gauge: Square embedded gauge | Setting pressure: 0.05–0.85 MPa | Max working pressure: 1.0 MPa | Proof pressure: 1.5 MPa | Operating temperature: -5 to 60°C | Spec: Clean/Low-particle (-D)

Need a different model, or a part not listed here? Send us your parts list →