Solid State Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - US-H20 Heater Load Solid State Contactor (AC24-480V, 20A AC-1)
Family ID: MEL-US-H20
Mitsubishi Electric MS-T/N series US-H20 solid state contactor dedicated to heater loads, suited to injection moulding machines, semiconductor production equipment and similar applications. Wide main circuit voltage range AC24-480V with rated operational current 20A under AC-1 class between -10 and 40 degrees C, heater capacity 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control. Semiconductor switching gives long life in high frequency switching duty with no switching noise, no wearing parts and clean operation, and a front operation indicator shows the control input state. The DD code selects individual control in place of batch control and the HZ code supplies the unit without a cooling fin, while the RM code gives a rail mount only specification and the UF code a reduced width body. A charged part protection cover unit UN-CV501US and the power control unit UA-PC are available as options. Derate the rated operational current above 40 degrees C ambient. JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable.
8 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| US-H20 | US-H20 heater load solid state contactor, batch control, standard | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Batch control · Specification: Standard · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20HZ | US-H20 heater load solid state contactor, batch control, no cooling fin | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Batch control · Specification: No cooling fin · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20RM | US-H20 heater load solid state contactor, batch control, rail mount only | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Batch control · Specification: Rail mount only · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20UF | US-H20 heater load solid state contactor, batch control, reduced width | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Batch control · Specification: Reduced width · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20DD | US-H20 heater load solid state contactor, individual control, standard | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Individual control · Specification: Standard · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20DDHZ | US-H20 heater load solid state contactor, individual control, no cooling fin | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Individual control · Specification: No cooling fin · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20DDRM | US-H20 heater load solid state contactor, individual control, rail mount only | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Individual control · Specification: Rail mount only · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable | ||
| US-H20DDUF | US-H20 heater load solid state contactor, individual control, reduced width | Mitsubishi Electric | Type: Solid state contactor for heater loads · Frame: H20 · Circuit Control Method: Individual control · Specification: Reduced width · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 20A at -10 to 40 degrees C · Heater Capacity: 4kW at 1 phase 200V, 6.9kW at 3 phase 200V, 13.8kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable |