[Mitsubishi Electric] - US-H50 Heater Load Solid State Contactor (AC24-480V, 50A AC-1)
Solid State Contactors MITSUBISHI ELECTRIC

[Mitsubishi Electric] - US-H50 Heater Load Solid State Contactor (AC24-480V, 50A AC-1)

Family ID: MEL-US-H50

Mitsubishi Electric MS-T/N series US-H50 solid state contactor dedicated to heater loads, suited to injection moulding machines, semiconductor production equipment and similar applications. Wide main circuit voltage range AC24-480V with rated operational current 50A under AC-1 class between -10 and 40 degrees C, heater capacity 10kW at 1 phase 200V, 17.3kW at 3 phase 200V, 34.6kW at 3 phase 400V under batch control. Semiconductor switching gives long life in high frequency switching duty with no switching noise, no wearing parts and clean operation, and a front operation indicator shows the control input state. The DD code selects individual control in place of batch control and the HZ code supplies the unit without a cooling fin. A charged part protection cover unit UN-CV501US and the power control unit UA-PC are available as options. Derate the rated operational current above 40 degrees C ambient. JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable.

4 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
US-H50 US-H50 heater load solid state contactor, batch control, standard Mitsubishi Electric Type: Solid state contactor for heater loads · Frame: H50 · Circuit Control Method: Batch control · Specification: Standard · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 50A at -10 to 40 degrees C · Heater Capacity: 10kW at 1 phase 200V, 17.3kW at 3 phase 200V, 34.6kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable
US-H50HZ US-H50 heater load solid state contactor, batch control, no cooling fin Mitsubishi Electric Type: Solid state contactor for heater loads · Frame: H50 · Circuit Control Method: Batch control · Specification: No cooling fin · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 50A at -10 to 40 degrees C · Heater Capacity: 10kW at 1 phase 200V, 17.3kW at 3 phase 200V, 34.6kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable
US-H50DD US-H50 heater load solid state contactor, individual control, standard Mitsubishi Electric Type: Solid state contactor for heater loads · Frame: H50 · Circuit Control Method: Individual control · Specification: Standard · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 50A at -10 to 40 degrees C · Heater Capacity: 10kW at 1 phase 200V, 17.3kW at 3 phase 200V, 34.6kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable
US-H50DDHZ US-H50 heater load solid state contactor, individual control, no cooling fin Mitsubishi Electric Type: Solid state contactor for heater loads · Frame: H50 · Circuit Control Method: Individual control · Specification: No cooling fin · Rated Voltage: AC24-480V · Rated Operational Current AC-1 Class: 50A at -10 to 40 degrees C · Heater Capacity: 10kW at 1 phase 200V, 17.3kW at 3 phase 200V, 34.6kW at 3 phase 400V under batch control · Charged Part Cover: Optional unit UN-CV501US · Ambient Derating: Derate the rated operational current above 40 degrees C ambient · Standards: JEM, IEC, UL, CSA, EC directive and TUV certified as standard, CCC is not applicable