Skip to product information
1 of 1

GGM K9I□40N Series 40W Three-phase AC Induction Motor (□90mm, 4-Pole, Lead Wire)

GGM K9I□40N Series 40W Three-phase AC Induction Motor (□90mm, 4-Pole, Lead Wire)

GGM K9I□40N series 40W three-phase AC induction motor. □90mm frame, 4-pole, continuous rating, lead wire (300mm, ul style 3271 awg20).

Key features

  • Straight (S) and pinion (G) shaft; 200–440V (50/60Hz)
  • Pinion-shaft type combines with K9G□ gear heads (matching face/teeth)
  • H variant (220/230V) UL certified (E204632)
  • Note: 3-phase motors for 380V and over cannot be used with an inverter

Specifications

Output 40W
Poles 4
Phase Three-phase
Frame □90mm
Connection Lead wire (300mm, UL Style 3271 AWG20)
K9IS40NT GGM 40W three-phase AC induction motor K9IS40NT — Straight shaft, 200V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 200V | Operating Points: 200V/50Hz: 0.39A, Start 1/10N·m·kgf·cm, Rated 0.3/3N·m·kgf·cm, 1300rpm ; 200V/60Hz: 0.32A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: —
K9IG40NT GGM 40W three-phase AC induction motor K9IG40NT — Pinion (for gear head) shaft, 200V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 200V | Operating Points: 200V/50Hz: 0.39A, Start 1/10N·m·kgf·cm, Rated 0.3/3N·m·kgf·cm, 1300rpm ; 200V/60Hz: 0.32A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: —
K9IS40NH GGM 40W three-phase AC induction motor K9IS40NH — Straight shaft, 220/230V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 220/230V | Operating Points: 220V/50Hz: 0.33A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 220V/60Hz: 0.31A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm ; 230V/50Hz: 0.41A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 230V/60Hz: 0.32A, Start 0.83/8.3N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: Certified (E204632)
K9IG40NH GGM 40W three-phase AC induction motor K9IG40NH — Pinion (for gear head) shaft, 220/230V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 220/230V | Operating Points: 220V/50Hz: 0.33A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 220V/60Hz: 0.31A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm ; 230V/50Hz: 0.41A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 230V/60Hz: 0.32A, Start 0.83/8.3N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: Certified (E204632)
K9IS40NM GGM 40W three-phase AC induction motor K9IS40NM — Straight shaft, 380V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 380V | Operating Points: 380V/50Hz: 0.18A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 380V/60Hz: 0.18A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NM GGM 40W three-phase AC induction motor K9IG40NM — Pinion (for gear head) shaft, 380V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 380V | Operating Points: 380V/50Hz: 0.18A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 380V/60Hz: 0.18A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NV GGM 40W three-phase AC induction motor K9IS40NV — Straight shaft, 400V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 400V | Operating Points: 400V/50Hz: 0.18A, Start 1.15/11.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 400V/60Hz: 0.19A, Start 0.88/8.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NV GGM 40W three-phase AC induction motor K9IG40NV — Pinion (for gear head) shaft, 400V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 400V | Operating Points: 400V/50Hz: 0.18A, Start 1.15/11.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 400V/60Hz: 0.19A, Start 0.88/8.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NQ GGM 40W three-phase AC induction motor K9IS40NQ — Straight shaft, 415V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 415V | Operating Points: 415V/50Hz: 0.16A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 415V/60Hz: 0.14A, Start 0.72/7.2N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NQ GGM 40W three-phase AC induction motor K9IG40NQ — Pinion (for gear head) shaft, 415V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 415V | Operating Points: 415V/50Hz: 0.16A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 415V/60Hz: 0.14A, Start 0.72/7.2N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NZ GGM 40W three-phase AC induction motor K9IS40NZ — Straight shaft, 440V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 440V | Operating Points: 440V/50Hz: 0.19A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 440V/60Hz: 0.16A, Start 0.79/7.9N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NZ GGM 40W three-phase AC induction motor K9IG40NZ — Pinion (for gear head) shaft, 440V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 440V | Operating Points: 440V/50Hz: 0.19A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 440V/60Hz: 0.16A, Start 0.79/7.9N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
AC Geared MotorsGGM
12 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

GGM K9I□40N Series 40W Three-phase AC Induction Motor (□90mm, 4-Pole, Lead Wire)

Brand GGM·AC Geared Motors

Available part numbers (12)

K9IS40NT, K9IG40NT, K9IS40NH, K9IG40NH, K9IS40NM, K9IG40NM, K9IS40NV, K9IG40NV, K9IS40NQ, K9IG40NQ + 2 more — see full table ↓

How to order

Send the GGM part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
K9IS40NTGGM 40W three-phase AC induction motor K9IS40NT — Straight shaft, 200V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 200V | Operating Points: 200V/50Hz: 0.39A, Start 1/10N·m·kgf·cm, Rated 0.3/3N·m·kgf·cm, 1300rpm ; 200V/60Hz: 0.32A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: —
K9IG40NTGGM 40W three-phase AC induction motor K9IG40NT — Pinion (for gear head) shaft, 200V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 200V | Operating Points: 200V/50Hz: 0.39A, Start 1/10N·m·kgf·cm, Rated 0.3/3N·m·kgf·cm, 1300rpm ; 200V/60Hz: 0.32A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: —
K9IS40NHGGM 40W three-phase AC induction motor K9IS40NH — Straight shaft, 220/230V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 220/230V | Operating Points: 220V/50Hz: 0.33A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 220V/60Hz: 0.31A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm ; 230V/50Hz: 0.41A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 230V/60Hz: 0.32A, Start 0.83/8.3N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: Certified (E204632)
K9IG40NHGGM 40W three-phase AC induction motor K9IG40NH — Pinion (for gear head) shaft, 220/230V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 220/230V | Operating Points: 220V/50Hz: 0.33A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 220V/60Hz: 0.31A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm ; 230V/50Hz: 0.41A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 230V/60Hz: 0.32A, Start 0.83/8.3N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: Certified (E204632)
K9IS40NMGGM 40W three-phase AC induction motor K9IS40NM — Straight shaft, 380V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 380V | Operating Points: 380V/50Hz: 0.18A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 380V/60Hz: 0.18A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NMGGM 40W three-phase AC induction motor K9IG40NM — Pinion (for gear head) shaft, 380V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 380V | Operating Points: 380V/50Hz: 0.18A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 380V/60Hz: 0.18A, Start 0.78/7.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NVGGM 40W three-phase AC induction motor K9IS40NV — Straight shaft, 400V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 400V | Operating Points: 400V/50Hz: 0.18A, Start 1.15/11.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 400V/60Hz: 0.19A, Start 0.88/8.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NVGGM 40W three-phase AC induction motor K9IG40NV — Pinion (for gear head) shaft, 400V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 400V | Operating Points: 400V/50Hz: 0.18A, Start 1.15/11.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 400V/60Hz: 0.19A, Start 0.88/8.8N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NQGGM 40W three-phase AC induction motor K9IS40NQ — Straight shaft, 415V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 415V | Operating Points: 415V/50Hz: 0.16A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 415V/60Hz: 0.14A, Start 0.72/7.2N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NQGGM 40W three-phase AC induction motor K9IG40NQ — Pinion (for gear head) shaft, 415V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 415V | Operating Points: 415V/50Hz: 0.16A, Start 0.95/9.5N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 415V/60Hz: 0.14A, Start 0.72/7.2N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IS40NZGGM 40W three-phase AC induction motor K9IS40NZ — Straight shaft, 440V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 440V | Operating Points: 440V/50Hz: 0.19A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 440V/60Hz: 0.16A, Start 0.79/7.9N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)
K9IG40NZGGM 40W three-phase AC induction motor K9IG40NZ — Pinion (for gear head) shaft, 440V, Lead wire (300mm, UL Style 3271 AWG20) | Output: 40W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Lead wire (300mm, UL Style 3271 AWG20) | Voltage: 440V | Operating Points: 440V/50Hz: 0.19A, Start 1/10N·m·kgf·cm, Rated 0.29/2.9N·m·kgf·cm, 1350rpm ; 440V/60Hz: 0.16A, Start 0.79/7.9N·m·kgf·cm, Rated 0.245/2.45N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)

Need a different model, or a part not listed here? Send us your parts list →