Operation and application are the same as type GCO-C with an added instantaneous trip unit for generator, transmission line, distribution line and motor protection.

Key features

  • Instantaneous trip unit (IIT) 20-80 A
  • Inverse and very inverse time characteristics
  • ICS coil options: DC current 0.2/2.0 A, 0.5/2.0 A, 1.0 A; DC voltage 24/110/125 V; AC current 0.5/1.0/2.0 A; AC voltage 110/220 V

Specifications

Frequency 60 Hz (standard), 50 Hz (option)
Case Color Munsell N1.5
GCO-CIⅢ4 Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢ39 Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢ3 Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢ2 Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ4 Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ39 Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ3 Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ2 Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢD4 Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅢD39 Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅢD3 Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅢD2 Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD4 Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD39 Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD3 Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD2 Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
Induction Protective RelaysKyongbo Electric
16 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Kyongbo Electric Induction Over Current Relay with Instantaneous Unit GCO-CI (Normally Open Contact)

Brand Kyongbo Electric·Induction Protective Relays

Available part numbers (16)

GCO-CIⅢ4, GCO-CIⅢ39, GCO-CIⅢ3, GCO-CIⅢ2, GCO-CIⅡ4, GCO-CIⅡ39, GCO-CIⅡ3, GCO-CIⅡ2, GCO-CIⅢD4, GCO-CIⅢD39 + 6 more — see full table ↓

How to order

Send the Kyongbo Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
GCO-CIⅢ4Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢ39Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢ3Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢ2Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ4Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ39Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ3Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅡ2Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg
GCO-CIⅢD4Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅢD39Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅢD3Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅢD2Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD4Tap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD39Tap Range: 3-9 A | Taps: 3, 4, 5, 6, 7, 8, 9 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD3Tap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg
GCO-CIⅡD2Tap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Very inverse | Rating: 5 A | IIT Unit: 20-80 A | ICS Unit: DC 0.5/2.0 A | Case: Drawout | Weight: approx. 4 kg

Need a different model, or a part not listed here? Send us your parts list →