Key features

  • Harmonic suppression (equivalent-capacity conversion coefficient K5=0), standard power regeneration (100% continuous / 150% 60s), input power factor 0.99+, up to 10 inverters connectable

Specifications

Rated Input Voltage 3-ph 200-220V 50Hz / 200-230V 60Hz
Overload 150% 60s
Frequency Fluctuation +/-5%
Input Power Factor 0.99 or more (at 100% load)
Power Regeneration 100% torque continuous / 150% torque 60s max
Harmonic Suppression equivalent-capacity conversion coefficient K5=0
Multi-inverter up to 10 units connectable
Cooling Forced-air
FR-HC2-7.5K FR-HC2 high power factor converter 7.5kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 7.5 kW | Rated DC Output Capacity: 10.7 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 33 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 14 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Closed IP20 | Cooling: Forced-air | Mass (converter): 7 kg | Included Peripherals: Reactor 1 (FR-HCL21-7.5K), Reactor 2 (FR-HCL22-7.5K), Outside Box (FR-HCB2-7.5K)
FR-HC2-15K FR-HC2 high power factor converter 15kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 15 kW | Rated DC Output Capacity: 19.8 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 61 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 25 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Closed IP20 | Cooling: Forced-air | Mass (converter): 12 kg | Included Peripherals: Reactor 1 (FR-HCL21-15K), Reactor 2 (FR-HCL22-15K), Outside Box (FR-HCB2-15K)
FR-HC2-30K FR-HC2 high power factor converter 30kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 30 kW | Rated DC Output Capacity: 38 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 115 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 47 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Open IP00 | Cooling: Forced-air | Mass (converter): 24 kg | Included Peripherals: Reactor 1 (FR-HCL21-30K), Reactor 2 (FR-HCL22-30K), Outside Box (FR-HCB2-30K)
FR-HC2-55K FR-HC2 high power factor converter 55kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 55 kW | Rated DC Output Capacity: 71 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 215 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 88 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Open IP00 | Cooling: Forced-air | Mass (converter): 39 kg | Included Peripherals: Reactor 1 (FR-HCL21-55K), Reactor 2 (FR-HCL22-55K), Outside Box (FR-HCB2-55K)
FR-HC2-75K FR-HC2 high power factor converter 75kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 75 kW | Rated DC Output Capacity: 92 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 278 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-230V 50/60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 110 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Open IP00 | Cooling: Forced-air | Mass (converter): 53 kg | Included Peripherals: Reactor 1 (FR-HCL21-75K), Reactor 2 (FR-HCL22-75K), Outside Box (FR-HCB2-75K)
Converter UnitsMitsubishi Electric
5 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric FR-HC2 High Power Factor Converter (3-Phase 200V, 7.5-75kW)

Brand Mitsubishi Electric·Converter Units

Available part numbers (5)

FR-HC2-7.5K, FR-HC2-15K, FR-HC2-30K, FR-HC2-55K, FR-HC2-75K

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
FR-HC2-7.5KFR-HC2 high power factor converter 7.5kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 7.5 kW | Rated DC Output Capacity: 10.7 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 33 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 14 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Closed IP20 | Cooling: Forced-air | Mass (converter): 7 kg | Included Peripherals: Reactor 1 (FR-HCL21-7.5K), Reactor 2 (FR-HCL22-7.5K), Outside Box (FR-HCB2-7.5K)
FR-HC2-15KFR-HC2 high power factor converter 15kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 15 kW | Rated DC Output Capacity: 19.8 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 61 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 25 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Closed IP20 | Cooling: Forced-air | Mass (converter): 12 kg | Included Peripherals: Reactor 1 (FR-HCL21-15K), Reactor 2 (FR-HCL22-15K), Outside Box (FR-HCB2-15K)
FR-HC2-30KFR-HC2 high power factor converter 30kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 30 kW | Rated DC Output Capacity: 38 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 115 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 47 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Open IP00 | Cooling: Forced-air | Mass (converter): 24 kg | Included Peripherals: Reactor 1 (FR-HCL21-30K), Reactor 2 (FR-HCL22-30K), Outside Box (FR-HCB2-30K)
FR-HC2-55KFR-HC2 high power factor converter 55kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 55 kW | Rated DC Output Capacity: 71 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 215 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 88 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Open IP00 | Cooling: Forced-air | Mass (converter): 39 kg | Included Peripherals: Reactor 1 (FR-HCL21-55K), Reactor 2 (FR-HCL22-55K), Outside Box (FR-HCB2-55K)
FR-HC2-75KFR-HC2 high power factor converter 75kW, 200V class, harmonic suppression + power regeneration | Applicable Inverter Capacity: 75 kW | Rated DC Output Capacity: 92 kW | Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz | Rated Input Current: 278 A | Overload: 150% 60s | Permissible Voltage Fluctuation: 170-230V 50/60Hz | Frequency Fluctuation: +/-5% | Input Power Factor: 0.99 or more (at 100% load) | Power Supply Capacity: 110 kVA | Power Regeneration: 100% torque continuous / 150% torque 60s max | Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 | Multi-inverter: up to 10 units connectable | Enclosure: Open IP00 | Cooling: Forced-air | Mass (converter): 53 kg | Included Peripherals: Reactor 1 (FR-HCL21-75K), Reactor 2 (FR-HCL22-75K), Outside Box (FR-HCB2-75K)

Need a different model, or a part not listed here? Send us your parts list →