Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| FR-A846-0.4K | FR-A846 three-phase 400v IP55 inverter, ND 0.4kW (00023) | Applied Motor (ND): 0.4 kW | Max Applied Motor (LD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00023 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 15 kg | ||
| FR-A846-0.75K | FR-A846 three-phase 400v IP55 inverter, ND 0.75kW (00038) | Applied Motor (ND): 0.75 kW | Max Applied Motor (LD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00038 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 15 kg | ||
| FR-A846-1.5K | FR-A846 three-phase 400v IP55 inverter, ND 1.5kW (00052) | Applied Motor (ND): 1.5 kW | Max Applied Motor (LD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00052 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 15 kg | ||
| FR-A846-2.2K | FR-A846 three-phase 400v IP55 inverter, ND 2.2kW (00083) | Applied Motor (ND): 2.2 kW | Max Applied Motor (LD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00083 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 15 kg | ||
| FR-A846-3.7K | FR-A846 three-phase 400v IP55 inverter, ND 3.7kW (00126) | Applied Motor (ND): 3.7 kW | Max Applied Motor (LD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00126 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 16 kg | ||
| FR-A846-5.5K | FR-A846 three-phase 400v IP55 inverter, ND 5.5kW (00170) | Applied Motor (ND): 5.5 kW | Max Applied Motor (LD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00170 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 17 kg | ||
| FR-A846-7.5K | FR-A846 three-phase 400v IP55 inverter, ND 7.5kW (00250) | Applied Motor (ND): 7.5 kW | Max Applied Motor (LD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00250 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 26 kg | ||
| FR-A846-11K | FR-A846 three-phase 400v IP55 inverter, ND 11kW (00310) | Applied Motor (ND): 11 kW | Max Applied Motor (LD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00310 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 26 kg | ||
| FR-A846-15K | FR-A846 three-phase 400v IP55 inverter, ND 15kW (00380) | Applied Motor (ND): 15 kW | Max Applied Motor (LD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00380 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 27 kg | ||
| FR-A846-18.5K | FR-A846 three-phase 400v IP55 inverter, ND 18.5kW (00470) | Applied Motor (ND): 18.5 kW | Max Applied Motor (LD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00470 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 27 kg | ||
| FR-A846-22K | FR-A846 three-phase 400v IP55 inverter, ND 22kW (00620) | Applied Motor (ND): 22 kW | Max Applied Motor (LD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00620 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 59 kg | ||
| FR-A846-30K | FR-A846 three-phase 400v IP55 inverter, ND 30kW (00770) | Applied Motor (ND): 30 kW | Max Applied Motor (LD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00770 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 60 kg | ||
| FR-A846-37K | FR-A846 three-phase 400v IP55 inverter, ND 37kW (00930) | Applied Motor (ND): 37 kW | Max Applied Motor (LD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 00930 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 63 kg | ||
| FR-A846-45K | FR-A846 three-phase 400v IP55 inverter, ND 45kW (01160) | Applied Motor (ND): 45 kW | Max Applied Motor (LD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 01160 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 64 kg | ||
| FR-A846-55K | FR-A846 three-phase 400v IP55 inverter, ND 55kW (01800) | Applied Motor (ND): 55 kW | Max Applied Motor (LD): 75 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 01800 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 147 kg | ||
| FR-A846-75K | FR-A846 three-phase 400v IP55 inverter, ND 75kW (02160) | Applied Motor (ND): 75 kW | Max Applied Motor (LD): 90 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 02160 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 150 kg | ||
| FR-A846-90K | FR-A846 three-phase 400v IP55 inverter, ND 90kW (02600) | Applied Motor (ND): 90 kW | Max Applied Motor (LD): 110 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 02600 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 153 kg | ||
| FR-A846-110K | FR-A846 three-phase 400v IP55 inverter, ND 110kW (03250) | Applied Motor (ND): 110 kW | Max Applied Motor (LD): 132 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 03250 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 189 kg | ||
| FR-A846-132K | FR-A846 three-phase 400v IP55 inverter, ND 132kW (03610) | Applied Motor (ND): 132 kW | Max Applied Motor (LD): 160 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: LD/ND selectable | Inverter Rating Code: 03610 | Protection: IP55 (dust/water-proof), UL Type 12 | Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable | Cooling: Self/Forced-air cooling + internal circulation fan | Weight: 193 kg |