Skip to product information
1 of 1

Woonyoung General Type Single Phase SSR WYG / WYH (10-80A)

Woonyoung General Type Single Phase SSR WYG / WYH (10-80A)

General-type single-phase SSR series rated AC 90-240V (WYG) or 90-480V (WYH), 10-80A, for resistive and general inductive loads, with an LED showing ON/OFF state.

Key features

  • cUL certified (10-40 A Z4 types, UL508)
  • Zero cross (Z) or random (R) switching
  • DC 4-32 V or AC 90-240 V control input
  • LED status indicator

Specifications

Phase 1
Weight 0.1 kg
Leakage current 10 mA
WYG1C10Z4 Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C10R4 Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C10Z40 Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C10R40 Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C20Z4 Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C20R4 Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C20Z40 Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C20R40 Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C30Z4 Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C30R4 Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C30Z40 Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C30R40 Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C40Z4 Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C40R4 Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C40Z40 Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C40R40 Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C50Z4 Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C50R4 Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C50Z40 Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C50R40 Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C60Z4 Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C60R4 Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C60Z40 Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C60R40 Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C80Z4 Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C80R4 Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C80Z40 Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C80R40 Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C10Z4 Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C10R4 Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C10Z40 Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C10R40 Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C20Z4 Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C20R4 Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C20Z40 Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C20R40 Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C30Z4 Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C30R4 Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C30Z40 Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C30R40 Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C40Z4 Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C40R4 Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C40Z40 Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C40R40 Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C50Z4 Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C50R4 Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C50Z40 Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C50R40 Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C60Z4 Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C60R4 Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C60Z40 Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C60R40 Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C80Z4 Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C80R4 Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C80Z40 Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C80R40 Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)
Solid State RelaysWoonyoung
56 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Woonyoung General Type Single Phase SSR WYG / WYH (10-80A)

Brand Woonyoung·Solid State Relays

Available part numbers (56)

WYG1C10Z4, WYG1C10R4, WYG1C10Z40, WYG1C10R40, WYG1C20Z4, WYG1C20R4, WYG1C20Z40, WYG1C20R40, WYG1C30Z4, WYG1C30R4 + 46 more — see full table ↓

How to order

Send the Woonyoung part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
WYG1C10Z4Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C10R4Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C10Z40Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C10R40Phase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C20Z4Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C20R4Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C20Z40Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C20R40Phase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C30Z4Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C30R4Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C30Z40Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C30R40Phase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C40Z4Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C40R4Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C40Z40Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C40R40Phase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C50Z4Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C50R4Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C50Z40Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C50R40Phase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C60Z4Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C60R4Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C60Z40Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C60R40Phase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYG1C80Z4Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross
WYG1C80R4Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYG1C80Z40Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross
WYG1C80R40Phase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C10Z4Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C10R4Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C10Z40Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C10R40Phase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C20Z4Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C20R4Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C20Z40Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C20R40Phase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C30Z4Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C30R4Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C30Z40Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C30R40Phase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C40Z4Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C40R4Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C40Z40Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C40R40Phase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C50Z4Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C50R4Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C50Z40Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C50R40Phase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C60Z4Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C60R4Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C60Z40Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C60R40Phase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)
WYH1C80Z4Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross
WYH1C80R4Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)
WYH1C80Z40Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross
WYH1C80R40Phase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)

Need a different model, or a part not listed here? Send us your parts list →