Fiber Optic
Omron
[OMRON] — E3NX-FA High-Function Smart Fiber Amplifier (Multi-Output, External Input, IO-Link, Smart Verify)
Family ID: OMRON-E3NX-FA-HF
High-function smart fiber amplifier with multi-output (2-output), external input, and IO-Link variants for advanced industrial automation. GIGA RAY2S light source delivers 1.5x sensing distance vs E3X-HD. Smart Tuning with 40,000x light intensity range provides stable detection even with saturated incident light. Solution Viewer + Change Finder visualize workpiece transit time and high-speed values. External input enables remote tuning, BANK switching, zero reset, and more. Output 2 modes include Alarm output, Error output, and Differential detection. ⭐ NEW: IO-Link Class 2 models (E3NX-FA51-IL3, E3NX-FA54-IL3) with Smart Verify alarm function for preventive maintenance — alerts on parameter changes or unintended operation. White 7-segment display, BANK 1~4 selectable, four response modes (SHS 30μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP. APC + DPC auto-compensation. Compatible with OMRON E32 series fiber optic heads. M8 connector models compatible with XS3F-M421/M422 cables (separately listed). Wire-saving Connectors (E3X-CN21 Master 4-conductor / E3X-CN22 Slave 2-conductor — different from standard FA6/FA8 connectors), Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
11 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| E3NX-FA21 2M | OMRON E3NX-FA21 high-function smart fiber amplifier, NPN, 2-output + 1-input, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 2 outputs + 1 input | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA51 2M | OMRON E3NX-FA51 high-function smart fiber amplifier, PNP, 2-output + 1-input, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 2 outputs + 1 input | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA51-IL3 2M | OMRON E3NX-FA51-IL3 high-function smart fiber amplifier, PNP, IO-Link Class 2, Smart Verify function, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: IO-Link Class 2 (input/output) ⭐ NEW | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA7 | OMRON E3NX-FA7 high-function smart fiber amplifier, NPN, 1-output + 1-input, wire-saving. | OMRON | Output: NPN | I/O Configuration: 1 output + 1 input | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA9 | OMRON E3NX-FA9 high-function smart fiber amplifier, PNP, 1-output + 1-input, wire-saving. | OMRON | Output: PNP | I/O Configuration: 1 output + 1 input | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA7TW | OMRON E3NX-FA7TW high-function smart fiber amplifier, NPN, 2-output, wire-saving. | OMRON | Output: NPN | I/O Configuration: 2 outputs | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA9TW | OMRON E3NX-FA9TW high-function smart fiber amplifier, PNP, 2-output, wire-saving. | OMRON | Output: PNP | I/O Configuration: 2 outputs | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA24 | OMRON E3NX-FA24 high-function smart fiber amplifier, NPN, 1-output + 1-input, M8 connector. | OMRON | Output: NPN | I/O Configuration: 1 output + 1 input | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA54 | OMRON E3NX-FA54 high-function smart fiber amplifier, PNP, 1-output + 1-input, M8 connector. | OMRON | Output: PNP | I/O Configuration: 1 output + 1 input | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA54TW | OMRON E3NX-FA54TW high-function smart fiber amplifier, PNP, 2-output, M8 connector. | OMRON | Output: PNP | I/O Configuration: 2 outputs | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | ||
| E3NX-FA54-IL3 | OMRON E3NX-FA54-IL3 high-function smart fiber amplifier, PNP, IO-Link Class 2, Smart Verify function, M8 connector. | OMRON | Output: PNP | I/O Configuration: IO-Link Class 2 (input/output) ⭐ NEW | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |