Servo Valves
Yuken
[YUKEN] — LSVHG-03EH-230 Two-Stage OBE Linear Servo Valve (230 L/min)
Family ID: YK-LSVHG03EH-230
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 230 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
6 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| LSVHG-03EH-230-2L-A | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | ||
| LSVHG-03EH-230-2L-B | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | ||
| LSVHG-03EH-230-2L-C | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | ||
| LSVHG-03EH-230-2L-D | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | ||
| LSVHG-03EH-230-2L-E | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | ||
| LSVHG-03EH-230-2L-F | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |