Key features

  • Pilot-operated diaphragm 2-port valves (NC), 1 to 4 stations on a 1000-series modular base
  • FR unit: piping adapter (A), regulator (R/RT8) or NC auto-drain filter regulator (W/WT8), Rc3/8 IN
  • Outlet push-in fittings 6 or 8 mm, straight or elbow; reverse layout X puts IN and FR unit on the right
  • Coil: grommet lead wire (2C) or DIN terminal box Pg7 with lamp (2H) / lamp + surge killer (2HS)
  • Supplied as one order code, eliminating piping between FR equipment and valves

Specifications

Fluid Compressed air
Operating pressure differential 0.01 to 0.7 MPa
Max. operating pressure 0.7 MPa
Proof pressure 1.05 MPa
Fluid / ambient temperature 5 to 55 C
Valve structure Pilot-operated diaphragm, NC
IN port Rc3/8
Flow C (OUT 6 / 8 mm) 1.6 / 3.0 dm3/(s.bar)
Regulator set pressure 0.05 to 0.7 MPa (with relief)
Filter rating 5 um, drain capacity 12 cm3
Source CKD Korea catalog CB-024SK-9, p. 1077-1081
CXU10-GEXA-C6-A-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-A-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-A-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-A-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-1-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-1-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-1-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-1-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-2-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-2-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-2-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-2-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-3-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-3-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-3-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-3-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-4-2C-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-4-2C-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-4-2H-1 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-4-2HS-3 Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-1-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-1-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-1-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-1-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-2-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-2-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-2-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-2-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-3-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-3-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-3-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-3-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-4-2C-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-4-2C-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-4-2H-1 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-4-2HS-3 Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-1-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-1-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-1-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-1-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-2-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-2-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-2-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-2-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-3-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-3-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-3-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-3-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-4-2C-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-4-2C-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-4-2H-1 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-4-2HS-3 Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-1-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-1-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-1-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-1-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-2-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-2-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-2-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-2-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-3-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-3-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-3-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-3-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-4-2C-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-4-2C-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-4-2H-1 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-4-2HS-3 Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA Legacy code CXU10-GEXA (previous base code; order full code above)
Solenoid ValvesCKD
577 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

CKD CXU10-GEXA Valve Air Unit (Pilot 2-Port Valve + FR, 1-4 Stations)

Brand CKD·Solenoid Valves

Available part numbers (577)

CXU10-GEXA-C6-A-1-2C-1, CXU10-GEXA-C6-A-1-2C-3, CXU10-GEXA-C6-A-1-2H-1, CXU10-GEXA-C6-A-1-2HS-3, CXU10-GEXA-C6-A-2-2C-1, CXU10-GEXA-C6-A-2-2C-3, CXU10-GEXA-C6-A-2-2H-1, CXU10-GEXA-C6-A-2-2HS-3, CXU10-GEXA-C6-A-3-2C-1, CXU10-GEXA-C6-A-3-2C-3 + 567 more — see full table ↓

How to order

Send the CKD part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
CXU10-GEXA-C6-A-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-A-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-A-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-A-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-A-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-A-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-A-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-R-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-R-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-R-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-R-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RX-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RX-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RX-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RX-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-RT8X-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-RT8X-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-RT8X-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-RT8X-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-W-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-W-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-W-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-W-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WX-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WX-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WX-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WX-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-1-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-1-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-1-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-1-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-2-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-2-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-2-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-2-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-3-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-3-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-3-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-3-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C6-WT8X-4-2C-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C6-WT8X-4-2C-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C6-WT8X-4-2H-1Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C6-WT8X-4-2HS-3Outlet: Push-in 6 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-A-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-A-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-A-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-A-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-R-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-R-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-R-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-R-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RX-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RX-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RX-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RX-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-RT8X-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-RT8X-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-W-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-W-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-W-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-W-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WX-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WX-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WX-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WX-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-1-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-1-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-1-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-1-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-2-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-2-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-2-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-2-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-3-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-3-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-3-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-3-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-4-2C-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-4-2C-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL6-WT8X-4-2H-1Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL6-WT8X-4-2HS-3Outlet: Push-in 6 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-A-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-A-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-A-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-A-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-R-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-R-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-R-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-R-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RX-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RX-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RX-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RX-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-RT8X-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-RT8X-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-RT8X-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-RT8X-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-W-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-W-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-W-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-W-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WX-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WX-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WX-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WX-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-1-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-1-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-1-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-1-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-2-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-2-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-2-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-2-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-3-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-3-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-3-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-3-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-C8-WT8X-4-2C-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-C8-WT8X-4-2C-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-C8-WT8X-4-2H-1Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-C8-WT8X-4-2HS-3Outlet: Push-in 8 mm straight | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-A-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-A-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-A-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-A-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Piping adapter Rc3/8 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-R-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-R-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-R-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-R-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RX-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RX-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RX-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RX-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator R2000-10-W-X2 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-RT8X-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-RT8X-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-W-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-W-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-W-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-W-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WX-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WX-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WX-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WX-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator W2000-10-W-F1 | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Left | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-1-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-1-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-1-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-1-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 1 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-2-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-2-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-2-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-2-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 2 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-3-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-3-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-3-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-3-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 3 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-4-2C-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-4-2C-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: Lead wire (no lamp/surge) | Voltage: DC24V
CXU10-GEXA-CL8-WT8X-4-2H-1Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp | Voltage: AC100V
CXU10-GEXA-CL8-WT8X-4-2HS-3Outlet: Push-in 8 mm elbow | FR unit: Filter regulator, no gauge | IN side: Right | Valves: 4 | Coil: DIN box Pg7, lamp + surge | Voltage: DC24V
CXU10-GEXALegacy code CXU10-GEXA (previous base code; order full code above)

Need a different model, or a part not listed here? Send us your parts list →