Key features

  • Two valve positions per sub-base: masking plate, 2-pos single/double, 3-pos closed, ABR or PAB centre
  • A/B ports push-in 4, 6, 8 mm or 6 mm rear elbow; R1/R2 exhaust Rc1/4
  • Wiring B = DIN terminal box Pg7, E20 = E connector 500 mm; surge killer and lamp standard
  • Option S: two silencers SLW-8S supplied; exhaust malfunction prevention valve on 2-pos/ABR
  • Replacement valves 4GB2*9R and masking plate 4G2R-MP listed separately

Specifications

Valve type Pilot-operated soft spool valve
Fluid Compressed air
Operating pressure 0.2 to 0.7 MPa
Proof pressure 1.05 MPa
Fluid temperature 5 to 55 C
Manual override Non-locking / locking
Power consumption 0.4 W (DC24V), 0.98 VA (AC100V)
Flow C (2-pos, P to A/B) 2.3 dm3/(s.bar)
Mass Sub-base 0.32 kg + valves 0.08-0.15 kg each
Source CKD Korea catalog CB-024SK-9, p. 1104-1109
CXU30-4G2R-01-C4-B-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C4-B-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C4-BS-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C4-BS-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C4-E20-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C4-E20-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C4-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C4-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C6-B-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C6-B-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C6-BS-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C6-BS-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C6-E20-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C6-E20-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C6-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C6-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-CL6-B-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-CL6-B-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-CL6-BS-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-CL6-BS-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-CL6-E20-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-CL6-E20-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-CL6-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-CL6-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C8-B-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C8-B-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C8-BS-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C8-BS-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C8-E20-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C8-E20-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C8-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C8-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C4-B-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C4-B-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C4-BS-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C4-BS-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C4-E20-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C4-E20-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C4-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C4-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C6-B-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C6-B-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C6-BS-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C6-BS-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C6-E20-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C6-E20-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C6-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C6-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-CL6-B-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-CL6-B-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-CL6-BS-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-CL6-BS-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-CL6-E20-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-CL6-E20-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-CL6-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-CL6-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C8-B-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C8-B-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C8-BS-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C8-BS-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C8-E20-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C8-E20-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C8-E20S-1 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C8-E20S-3 Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C4-B-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C4-B-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C4-BS-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C4-BS-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C4-E20-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C4-E20-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C4-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C4-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C6-B-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C6-B-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C6-BS-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C6-BS-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C6-E20-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C6-E20-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C6-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C6-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-CL6-B-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-CL6-B-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-CL6-BS-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-CL6-BS-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-CL6-E20-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-CL6-E20-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-CL6-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-CL6-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C8-B-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C8-B-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C8-BS-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C8-BS-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C8-E20-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C8-E20-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C8-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C8-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C4-B-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C4-B-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C4-BS-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C4-BS-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C4-E20-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C4-E20-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C4-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C4-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C6-B-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C6-B-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C6-BS-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C6-BS-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C6-E20-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C6-E20-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C6-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C6-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-CL6-B-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-CL6-B-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-CL6-BS-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-CL6-BS-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-CL6-E20-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-CL6-E20-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-CL6-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-CL6-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C8-B-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C8-B-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C8-BS-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C8-BS-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C8-E20-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C8-E20-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C8-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C8-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C4-B-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C4-B-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C4-BS-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C4-BS-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C4-E20-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C4-E20-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C4-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C4-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C6-B-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C6-B-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C6-BS-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C6-BS-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C6-E20-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C6-E20-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C6-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C6-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-CL6-B-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-CL6-B-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-CL6-BS-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-CL6-BS-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-CL6-E20-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-CL6-E20-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-CL6-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-CL6-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C8-B-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C8-B-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C8-BS-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C8-BS-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C8-E20-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C8-E20-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C8-E20S-1 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C8-E20S-3 Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C4-B-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C4-B-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C4-BS-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C4-BS-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C4-E20-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C4-E20-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C4-E20S-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C4-E20S-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C6-B-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C6-B-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C6-BS-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C6-BS-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C6-E20-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C6-E20-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C6-E20S-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C6-E20S-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-CL6-B-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-CL6-B-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-CL6-BS-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-CL6-BS-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-CL6-E20-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-CL6-E20-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-CL6-E20S-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-CL6-E20S-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C8-B-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C8-B-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C8-BS-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C8-BS-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C8-E20-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C8-E20-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C8-E20S-1 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C8-E20S-3 Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C4-B-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C4-B-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C4-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C4-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C4-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C4-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C4-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C4-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C6-B-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C6-B-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C6-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C6-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C6-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C6-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C6-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C6-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-CL6-B-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-CL6-B-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-CL6-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-CL6-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-CL6-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-CL6-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-CL6-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-CL6-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C8-B-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C8-B-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C8-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C8-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C8-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C8-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C8-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C8-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C4-B-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C4-B-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C4-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C4-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C4-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C4-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C4-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C4-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C6-B-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C6-B-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C6-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C6-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C6-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C6-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C6-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C6-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-CL6-B-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-CL6-B-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-CL6-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-CL6-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-CL6-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-CL6-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-CL6-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-CL6-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C8-B-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C8-B-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C8-BS-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C8-BS-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C8-E20-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C8-E20-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C8-E20S-1 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C8-E20S-3 Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C4-B-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C4-B-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C4-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C4-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C4-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C4-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C4-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C4-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C6-B-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C6-B-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C6-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C6-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C6-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C6-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C6-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C6-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-CL6-B-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-CL6-B-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-CL6-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-CL6-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-CL6-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-CL6-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-CL6-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-CL6-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C8-B-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C8-B-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C8-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C8-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C8-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C8-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C8-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C8-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C4-B-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C4-B-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C4-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C4-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C4-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C4-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C4-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C4-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C6-B-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C6-B-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C6-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C6-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C6-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C6-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C6-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C6-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-CL6-B-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-CL6-B-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-CL6-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-CL6-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-CL6-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-CL6-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-CL6-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-CL6-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C8-B-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C8-B-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C8-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C8-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C8-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C8-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C8-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C8-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C4-B-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C4-B-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C4-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C4-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C4-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C4-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C4-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C4-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C6-B-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C6-B-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C6-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C6-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C6-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C6-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C6-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C6-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-CL6-B-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-CL6-B-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-CL6-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-CL6-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-CL6-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-CL6-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-CL6-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-CL6-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C8-B-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C8-B-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C8-BS-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C8-BS-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C8-E20-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C8-E20-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C8-E20S-1 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C8-E20S-3 Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C4-B-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C4-B-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C4-BS-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C4-BS-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C4-E20-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C4-E20-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C4-E20S-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C4-E20S-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C6-B-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C6-B-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C6-BS-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C6-BS-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C6-E20-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C6-E20-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C6-E20S-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C6-E20S-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-CL6-B-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-CL6-B-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-CL6-BS-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-CL6-BS-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-CL6-E20-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-CL6-E20-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-CL6-E20S-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-CL6-E20S-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C8-B-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C8-B-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C8-BS-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C8-BS-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C8-E20-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C8-E20-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C8-E20S-1 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C8-E20S-3 Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C4-B-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C4-B-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C4-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C4-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C4-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C4-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C4-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C4-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C6-B-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C6-B-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C6-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C6-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C6-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C6-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C6-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C6-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-CL6-B-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-CL6-B-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-CL6-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-CL6-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-CL6-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-CL6-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-CL6-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-CL6-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C8-B-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C8-B-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C8-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C8-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C8-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C8-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C8-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C8-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C4-B-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C4-B-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C4-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C4-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C4-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C4-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C4-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C4-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C6-B-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C6-B-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C6-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C6-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C6-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C6-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C6-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C6-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-CL6-B-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-CL6-B-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-CL6-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-CL6-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-CL6-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-CL6-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-CL6-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-CL6-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C8-B-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C8-B-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C8-BS-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C8-BS-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C8-E20-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C8-E20-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C8-E20S-1 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C8-E20S-3 Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C4-B-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C4-B-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C4-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C4-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C4-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C4-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C4-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C4-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C6-B-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C6-B-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C6-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C6-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C6-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C6-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C6-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C6-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-CL6-B-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-CL6-B-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-CL6-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-CL6-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-CL6-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-CL6-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-CL6-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-CL6-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C8-B-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C8-B-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C8-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C8-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C8-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C8-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C8-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C8-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C4-B-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C4-B-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C4-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C4-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C4-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C4-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C4-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C4-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C6-B-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C6-B-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C6-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C6-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C6-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C6-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C6-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C6-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-CL6-B-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-CL6-B-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-CL6-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-CL6-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-CL6-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-CL6-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-CL6-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-CL6-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C8-B-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C8-B-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C8-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C8-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C8-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C8-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C8-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C8-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C4-B-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C4-B-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C4-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C4-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C4-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C4-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C4-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C4-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C6-B-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C6-B-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C6-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C6-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C6-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C6-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C6-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C6-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-CL6-B-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-CL6-B-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-CL6-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-CL6-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-CL6-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-CL6-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-CL6-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-CL6-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C8-B-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C8-B-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C8-BS-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C8-BS-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C8-E20-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C8-E20-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C8-E20S-1 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C8-E20S-3 Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C4-B-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C4-B-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C4-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C4-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C4-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C4-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C4-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C4-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-CL6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-CL6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-CL6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-CL6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-CL6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-CL6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-CL6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-CL6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C8-B-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C8-B-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C8-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C8-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C8-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C8-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C8-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C8-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C4-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C4-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C4-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C4-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C4-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C4-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C4-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C4-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-CL6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-CL6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-CL6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-CL6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-CL6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-CL6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-CL6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-CL6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C8-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C8-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C8-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C8-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C8-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C8-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C8-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C8-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C4-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C4-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C4-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C4-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C4-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C4-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C4-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C4-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-CL6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-CL6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-CL6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-CL6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-CL6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-CL6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-CL6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-CL6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C8-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C8-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C8-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C8-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C8-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C8-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C8-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C8-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C4-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C4-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C4-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C4-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C4-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C4-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C4-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C4-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-CL6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-CL6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-CL6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-CL6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-CL6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-CL6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-CL6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-CL6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C8-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C8-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C8-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C8-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C8-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C8-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C8-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C8-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C4-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C4-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C4-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C4-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C4-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C4-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C4-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C4-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-CL6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-CL6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-CL6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-CL6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-CL6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-CL6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-CL6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-CL6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C8-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C8-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C8-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C8-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C8-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C8-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C8-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C8-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C4-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C4-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C4-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C4-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C4-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C4-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C4-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C4-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-CL6-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-CL6-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-CL6-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-CL6-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-CL6-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-CL6-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-CL6-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-CL6-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C8-B-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C8-B-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C8-BS-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C8-BS-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C8-E20-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C8-E20-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C8-E20S-1 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C8-E20S-3 Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C4-B-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C4-B-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C4-BS-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C4-BS-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C4-E20-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C4-E20-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C4-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C4-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C6-B-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C6-B-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-CL6-B-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-CL6-B-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-CL6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-CL6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-CL6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-CL6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-CL6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-CL6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C8-B-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C8-B-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C8-BS-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C8-BS-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C8-E20-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C8-E20-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C8-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C8-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C4-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C4-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C4-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C4-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C4-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C4-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C4-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C4-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-CL6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-CL6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-CL6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-CL6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-CL6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-CL6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-CL6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-CL6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C8-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C8-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C8-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C8-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C8-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C8-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C8-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C8-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C4-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C4-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C4-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C4-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C4-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C4-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C4-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C4-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-CL6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-CL6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-CL6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-CL6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-CL6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-CL6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-CL6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-CL6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C8-B-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C8-B-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C8-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C8-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C8-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C8-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C8-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C8-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C4-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C4-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C4-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C4-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C4-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C4-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C4-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C4-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-CL6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-CL6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-CL6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-CL6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-CL6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-CL6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-CL6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-CL6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C8-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C8-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C8-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C8-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C8-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C8-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C8-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C8-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C4-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C4-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C4-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C4-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C4-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C4-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C4-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C4-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-CL6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-CL6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-CL6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-CL6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-CL6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-CL6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-CL6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-CL6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C8-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C8-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C8-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C8-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C8-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C8-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C8-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C8-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C4-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C4-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C4-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C4-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C4-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C4-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C4-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C4-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-CL6-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-CL6-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-CL6-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-CL6-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-CL6-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-CL6-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-CL6-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-CL6-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C8-B-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C8-B-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C8-BS-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C8-BS-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C8-E20-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C8-E20-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C8-E20S-1 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C8-E20S-3 Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C4-B-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C4-B-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C4-BS-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C4-BS-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C4-E20-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C4-E20-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C4-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C4-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C6-B-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C6-B-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-CL6-B-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-CL6-B-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-CL6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-CL6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-CL6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-CL6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-CL6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-CL6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C8-B-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C8-B-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C8-BS-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C8-BS-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C8-E20-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C8-E20-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C8-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C8-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C4-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C4-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C4-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C4-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C4-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C4-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C4-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C4-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-CL6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-CL6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-CL6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-CL6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-CL6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-CL6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-CL6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-CL6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C8-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C8-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C8-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C8-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C8-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C8-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C8-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C8-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C4-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C4-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C4-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C4-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C4-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C4-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C4-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C4-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-CL6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-CL6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-CL6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-CL6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-CL6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-CL6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-CL6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-CL6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C8-B-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C8-B-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C8-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C8-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C8-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C8-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C8-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C8-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C4-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C4-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C4-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C4-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C4-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C4-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C4-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C4-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-CL6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-CL6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-CL6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-CL6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-CL6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-CL6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-CL6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-CL6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C8-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C8-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C8-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C8-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C8-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C8-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C8-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C8-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C4-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C4-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C4-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C4-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C4-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C4-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C4-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C4-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-CL6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-CL6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-CL6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-CL6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-CL6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-CL6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-CL6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-CL6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C8-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C8-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C8-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C8-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C8-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C8-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C8-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C8-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C4-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C4-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C4-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C4-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C4-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C4-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C4-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C4-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-CL6-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-CL6-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-CL6-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-CL6-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-CL6-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-CL6-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-CL6-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-CL6-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C8-B-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C8-B-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C8-BS-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C8-BS-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C8-E20-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C8-E20-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C8-E20S-1 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C8-E20S-3 Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R Legacy code CXU30-4G2R (previous base code; order full code above)
Solenoid ValvesCKD
1121 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

CKD CXU30-4G2R Module 5-Port Solenoid Valve (2-Station Sub-Base)

Brand CKD·Solenoid Valves

Available part numbers (1121)

CXU30-4G2R-01-C4-B-1, CXU30-4G2R-01-C4-B-3, CXU30-4G2R-01-C4-BS-1, CXU30-4G2R-01-C4-BS-3, CXU30-4G2R-01-C4-E20-1, CXU30-4G2R-01-C4-E20-3, CXU30-4G2R-01-C4-E20S-1, CXU30-4G2R-01-C4-E20S-3, CXU30-4G2R-01-C6-B-1, CXU30-4G2R-01-C6-B-3 + 1111 more — see full table ↓

How to order

Send the CKD part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
CXU30-4G2R-01-C4-B-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C4-B-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C4-BS-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C4-BS-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C4-E20-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C4-E20-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C4-E20S-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C4-E20S-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C6-B-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C6-B-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C6-BS-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C6-BS-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C6-E20-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C6-E20-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C6-E20S-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C6-E20S-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-CL6-B-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-CL6-B-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-CL6-BS-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-CL6-BS-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-CL6-E20-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-CL6-E20-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-CL6-E20S-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-CL6-E20S-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C8-B-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C8-B-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C8-BS-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C8-BS-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-01-C8-E20-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-01-C8-E20-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-01-C8-E20S-1Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-01-C8-E20S-3Valve 1: Masking plate | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C4-B-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C4-B-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C4-BS-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C4-BS-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C4-E20-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C4-E20-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C4-E20S-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C4-E20S-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C6-B-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C6-B-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C6-BS-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C6-BS-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C6-E20-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C6-E20-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C6-E20S-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C6-E20S-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-CL6-B-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-CL6-B-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-CL6-BS-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-CL6-BS-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-CL6-E20-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-CL6-E20-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-CL6-E20S-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-CL6-E20S-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C8-B-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C8-B-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C8-BS-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C8-BS-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-02-C8-E20-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-02-C8-E20-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-02-C8-E20S-1Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-02-C8-E20S-3Valve 1: Masking plate | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C4-B-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C4-B-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C4-BS-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C4-BS-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C4-E20-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C4-E20-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C4-E20S-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C4-E20S-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C6-B-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C6-B-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C6-BS-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C6-BS-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C6-E20-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C6-E20-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C6-E20S-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C6-E20S-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-CL6-B-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-CL6-B-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-CL6-BS-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-CL6-BS-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-CL6-E20-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-CL6-E20-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-CL6-E20S-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-CL6-E20S-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C8-B-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C8-B-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C8-BS-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C8-BS-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-03-C8-E20-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-03-C8-E20-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-03-C8-E20S-1Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-03-C8-E20S-3Valve 1: Masking plate | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C4-B-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C4-B-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C4-BS-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C4-BS-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C4-E20-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C4-E20-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C4-E20S-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C4-E20S-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C6-B-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C6-B-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C6-BS-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C6-BS-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C6-E20-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C6-E20-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C6-E20S-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C6-E20S-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-CL6-B-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-CL6-B-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-CL6-BS-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-CL6-BS-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-CL6-E20-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-CL6-E20-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-CL6-E20S-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-CL6-E20S-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C8-B-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C8-B-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C8-BS-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C8-BS-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-04-C8-E20-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-04-C8-E20-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-04-C8-E20S-1Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-04-C8-E20S-3Valve 1: Masking plate | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C4-B-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C4-B-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C4-BS-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C4-BS-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C4-E20-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C4-E20-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C4-E20S-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C4-E20S-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C6-B-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C6-B-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C6-BS-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C6-BS-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C6-E20-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C6-E20-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C6-E20S-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C6-E20S-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-CL6-B-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-CL6-B-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-CL6-BS-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-CL6-BS-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-CL6-E20-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-CL6-E20-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-CL6-E20S-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-CL6-E20S-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C8-B-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C8-B-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C8-BS-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C8-BS-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-05-C8-E20-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-05-C8-E20-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-05-C8-E20S-1Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-05-C8-E20S-3Valve 1: Masking plate | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C4-B-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C4-B-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C4-BS-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C4-BS-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C4-E20-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C4-E20-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C4-E20S-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C4-E20S-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C6-B-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C6-B-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C6-BS-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C6-BS-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C6-E20-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C6-E20-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C6-E20S-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C6-E20S-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-CL6-B-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-CL6-B-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-CL6-BS-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-CL6-BS-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-CL6-E20-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-CL6-E20-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-CL6-E20S-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-CL6-E20S-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C8-B-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C8-B-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C8-BS-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C8-BS-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-10-C8-E20-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-10-C8-E20-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-10-C8-E20S-1Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-10-C8-E20S-3Valve 1: 2-pos single | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C4-B-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C4-B-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C4-BS-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C4-BS-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C4-E20-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C4-E20-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C4-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C4-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C6-B-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C6-B-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C6-BS-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C6-BS-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C6-E20-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C6-E20-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C6-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C6-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-CL6-B-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-CL6-B-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-CL6-BS-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-CL6-BS-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-CL6-E20-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-CL6-E20-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-CL6-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-CL6-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C8-B-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C8-B-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C8-BS-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C8-BS-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-11-C8-E20-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-11-C8-E20-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-11-C8-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-11-C8-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C4-B-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C4-B-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C4-BS-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C4-BS-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C4-E20-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C4-E20-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C4-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C4-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C6-B-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C6-B-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C6-BS-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C6-BS-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C6-E20-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C6-E20-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C6-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C6-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-CL6-B-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-CL6-B-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-CL6-BS-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-CL6-BS-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-CL6-E20-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-CL6-E20-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-CL6-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-CL6-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C8-B-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C8-B-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C8-BS-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C8-BS-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-12-C8-E20-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-12-C8-E20-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-12-C8-E20S-1Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-12-C8-E20S-3Valve 1: 2-pos single | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C4-B-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C4-B-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C4-BS-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C4-BS-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C4-E20-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C4-E20-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C4-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C4-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C6-B-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C6-B-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C6-BS-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C6-BS-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C6-E20-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C6-E20-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C6-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C6-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-CL6-B-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-CL6-B-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-CL6-BS-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-CL6-BS-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-CL6-E20-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-CL6-E20-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-CL6-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-CL6-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C8-B-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C8-B-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C8-BS-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C8-BS-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-13-C8-E20-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-13-C8-E20-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-13-C8-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-13-C8-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C4-B-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C4-B-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C4-BS-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C4-BS-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C4-E20-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C4-E20-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C4-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C4-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C6-B-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C6-B-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C6-BS-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C6-BS-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C6-E20-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C6-E20-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C6-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C6-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-CL6-B-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-CL6-B-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-CL6-BS-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-CL6-BS-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-CL6-E20-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-CL6-E20-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-CL6-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-CL6-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C8-B-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C8-B-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C8-BS-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C8-BS-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-14-C8-E20-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-14-C8-E20-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-14-C8-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-14-C8-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C4-B-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C4-B-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C4-BS-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C4-BS-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C4-E20-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C4-E20-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C4-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C4-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C6-B-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C6-B-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C6-BS-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C6-BS-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C6-E20-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C6-E20-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C6-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C6-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-CL6-B-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-CL6-B-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-CL6-BS-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-CL6-BS-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-CL6-E20-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-CL6-E20-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-CL6-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-CL6-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C8-B-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C8-B-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C8-BS-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C8-BS-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-15-C8-E20-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-15-C8-E20-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-15-C8-E20S-1Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-15-C8-E20S-3Valve 1: 2-pos single | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C4-B-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C4-B-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C4-BS-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C4-BS-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C4-E20-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C4-E20-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C4-E20S-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C4-E20S-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C6-B-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C6-B-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C6-BS-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C6-BS-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C6-E20-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C6-E20-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C6-E20S-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C6-E20S-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-CL6-B-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-CL6-B-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-CL6-BS-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-CL6-BS-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-CL6-E20-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-CL6-E20-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-CL6-E20S-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-CL6-E20S-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C8-B-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C8-B-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C8-BS-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C8-BS-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-20-C8-E20-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-20-C8-E20-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-20-C8-E20S-1Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-20-C8-E20S-3Valve 1: 2-pos double | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C4-B-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C4-B-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C4-BS-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C4-BS-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C4-E20-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C4-E20-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C4-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C4-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C6-B-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C6-B-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C6-BS-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C6-BS-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C6-E20-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C6-E20-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C6-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C6-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-CL6-B-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-CL6-B-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-CL6-BS-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-CL6-BS-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-CL6-E20-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-CL6-E20-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-CL6-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-CL6-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C8-B-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C8-B-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C8-BS-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C8-BS-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-21-C8-E20-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-21-C8-E20-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-21-C8-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-21-C8-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C4-B-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C4-B-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C4-BS-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C4-BS-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C4-E20-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C4-E20-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C4-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C4-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C6-B-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C6-B-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C6-BS-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C6-BS-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C6-E20-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C6-E20-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C6-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C6-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-CL6-B-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-CL6-B-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-CL6-BS-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-CL6-BS-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-CL6-E20-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-CL6-E20-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-CL6-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-CL6-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C8-B-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C8-B-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C8-BS-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C8-BS-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-22-C8-E20-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-22-C8-E20-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-22-C8-E20S-1Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-22-C8-E20S-3Valve 1: 2-pos double | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C4-B-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C4-B-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C4-BS-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C4-BS-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C4-E20-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C4-E20-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C4-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C4-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C6-B-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C6-B-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C6-BS-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C6-BS-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C6-E20-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C6-E20-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C6-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C6-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-CL6-B-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-CL6-B-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-CL6-BS-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-CL6-BS-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-CL6-E20-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-CL6-E20-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-CL6-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-CL6-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C8-B-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C8-B-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C8-BS-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C8-BS-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-23-C8-E20-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-23-C8-E20-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-23-C8-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-23-C8-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C4-B-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C4-B-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C4-BS-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C4-BS-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C4-E20-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C4-E20-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C4-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C4-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C6-B-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C6-B-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C6-BS-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C6-BS-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C6-E20-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C6-E20-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C6-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C6-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-CL6-B-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-CL6-B-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-CL6-BS-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-CL6-BS-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-CL6-E20-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-CL6-E20-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-CL6-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-CL6-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C8-B-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C8-B-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C8-BS-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C8-BS-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-24-C8-E20-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-24-C8-E20-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-24-C8-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-24-C8-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C4-B-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C4-B-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C4-BS-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C4-BS-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C4-E20-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C4-E20-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C4-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C4-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C6-B-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C6-B-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C6-BS-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C6-BS-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C6-E20-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C6-E20-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C6-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C6-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-CL6-B-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-CL6-B-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-CL6-BS-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-CL6-BS-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-CL6-E20-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-CL6-E20-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-CL6-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-CL6-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C8-B-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C8-B-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C8-BS-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C8-BS-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-25-C8-E20-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-25-C8-E20-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-25-C8-E20S-1Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-25-C8-E20S-3Valve 1: 2-pos double | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C4-B-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C4-B-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C4-BS-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C4-BS-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C4-E20-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C4-E20-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C4-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C4-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C6-B-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C6-B-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-CL6-B-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-CL6-B-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-CL6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-CL6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-CL6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-CL6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-CL6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-CL6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C8-B-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C8-B-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C8-BS-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C8-BS-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-30-C8-E20-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-30-C8-E20-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-30-C8-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-30-C8-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C4-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C4-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C4-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C4-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C4-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C4-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C4-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C4-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-CL6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-CL6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-CL6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-CL6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-CL6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-CL6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-CL6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-CL6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C8-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C8-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C8-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C8-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-31-C8-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-31-C8-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-31-C8-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-31-C8-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C4-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C4-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C4-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C4-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C4-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C4-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C4-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C4-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-CL6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-CL6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-CL6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-CL6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-CL6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-CL6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-CL6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-CL6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C8-B-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C8-B-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C8-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C8-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-32-C8-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-32-C8-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-32-C8-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-32-C8-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C4-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C4-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C4-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C4-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C4-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C4-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C4-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C4-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-CL6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-CL6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-CL6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-CL6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-CL6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-CL6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-CL6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-CL6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C8-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C8-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C8-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C8-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-33-C8-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-33-C8-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-33-C8-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-33-C8-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C4-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C4-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C4-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C4-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C4-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C4-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C4-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C4-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-CL6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-CL6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-CL6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-CL6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-CL6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-CL6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-CL6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-CL6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C8-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C8-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C8-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C8-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-34-C8-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-34-C8-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-34-C8-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-34-C8-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C4-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C4-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C4-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C4-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C4-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C4-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C4-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C4-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-CL6-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-CL6-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-CL6-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-CL6-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-CL6-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-CL6-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-CL6-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-CL6-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C8-B-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C8-B-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C8-BS-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C8-BS-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-35-C8-E20-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-35-C8-E20-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-35-C8-E20S-1Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-35-C8-E20S-3Valve 1: 3-pos all ports blocked | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C4-B-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C4-B-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C4-BS-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C4-BS-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C4-E20-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C4-E20-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C4-E20S-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C4-E20S-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C6-B-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C6-B-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C6-BS-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C6-BS-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C6-E20-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C6-E20-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-CL6-B-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-CL6-B-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-CL6-BS-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-CL6-BS-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-CL6-E20-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-CL6-E20-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-CL6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-CL6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C8-B-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C8-B-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C8-BS-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C8-BS-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-40-C8-E20-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-40-C8-E20-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-40-C8-E20S-1Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-40-C8-E20S-3Valve 1: 3-pos ABR connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C4-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C4-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C4-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C4-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C4-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C4-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C4-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C4-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C6-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C6-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-CL6-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-CL6-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-CL6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-CL6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-CL6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-CL6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-CL6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-CL6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C8-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C8-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C8-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C8-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-41-C8-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-41-C8-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-41-C8-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-41-C8-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C4-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C4-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C4-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C4-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C4-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C4-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C4-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C4-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C6-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C6-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-CL6-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-CL6-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-CL6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-CL6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-CL6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-CL6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-CL6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-CL6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C8-B-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C8-B-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C8-BS-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C8-BS-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-42-C8-E20-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-42-C8-E20-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-42-C8-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-42-C8-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C4-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C4-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C4-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C4-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C4-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C4-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C4-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C4-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C6-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C6-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-CL6-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-CL6-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-CL6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-CL6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-CL6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-CL6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-CL6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-CL6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C8-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C8-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C8-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C8-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-43-C8-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-43-C8-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-43-C8-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-43-C8-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C4-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C4-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C4-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C4-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C4-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C4-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C4-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C4-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C6-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C6-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-CL6-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-CL6-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-CL6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-CL6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-CL6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-CL6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-CL6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-CL6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C8-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C8-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C8-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C8-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-44-C8-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-44-C8-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-44-C8-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-44-C8-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C4-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C4-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C4-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C4-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C4-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C4-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C4-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C4-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C6-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C6-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-CL6-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-CL6-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-CL6-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-CL6-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-CL6-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-CL6-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-CL6-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-CL6-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C8-B-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C8-B-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C8-BS-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C8-BS-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-45-C8-E20-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-45-C8-E20-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-45-C8-E20S-1Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-45-C8-E20S-3Valve 1: 3-pos ABR connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C4-B-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C4-B-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C4-BS-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C4-BS-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C4-E20-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C4-E20-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C4-E20S-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C4-E20S-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C6-B-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C6-B-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C6-BS-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C6-BS-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C6-E20-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C6-E20-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-CL6-B-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-CL6-B-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-CL6-BS-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-CL6-BS-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-CL6-E20-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-CL6-E20-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-CL6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-CL6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C8-B-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C8-B-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C8-BS-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C8-BS-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-50-C8-E20-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-50-C8-E20-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-50-C8-E20S-1Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-50-C8-E20S-3Valve 1: 3-pos PAB connection | Valve 2: Masking plate | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C4-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C4-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C4-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C4-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C4-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C4-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C4-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C4-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C6-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C6-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-CL6-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-CL6-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-CL6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-CL6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-CL6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-CL6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-CL6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-CL6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C8-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C8-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C8-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C8-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-51-C8-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-51-C8-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-51-C8-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-51-C8-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos single | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C4-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C4-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C4-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C4-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C4-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C4-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C4-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C4-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C6-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C6-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-CL6-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-CL6-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-CL6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-CL6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-CL6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-CL6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-CL6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-CL6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C8-B-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C8-B-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C8-BS-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C8-BS-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-52-C8-E20-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-52-C8-E20-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-52-C8-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-52-C8-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 2-pos double | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C4-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C4-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C4-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C4-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C4-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C4-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C4-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C4-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C6-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C6-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-CL6-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-CL6-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-CL6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-CL6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-CL6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-CL6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-CL6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-CL6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C8-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C8-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C8-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C8-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-53-C8-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-53-C8-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-53-C8-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-53-C8-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos all ports blocked | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C4-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C4-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C4-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C4-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C4-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C4-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C4-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C4-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C6-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C6-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-CL6-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-CL6-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-CL6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-CL6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-CL6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-CL6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-CL6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-CL6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C8-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C8-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C8-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C8-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-54-C8-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-54-C8-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-54-C8-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-54-C8-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos ABR connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C4-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C4-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C4-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C4-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C4-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C4-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C4-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C4-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 4 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C6-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C6-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-CL6-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-CL6-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-CL6-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-CL6-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-CL6-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-CL6-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-CL6-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-CL6-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 6 mm elbow (rear) | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C8-B-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C8-B-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C8-BS-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C8-BS-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: DIN box Pg7, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2R-55-C8-E20-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: AC100V
CXU30-4G2R-55-C8-E20-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: None | Voltage: DC24V
CXU30-4G2R-55-C8-E20S-1Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: AC100V
CXU30-4G2R-55-C8-E20S-3Valve 1: 3-pos PAB connection | Valve 2: 3-pos PAB connection | Outlet: Push-in 8 mm | Wiring: E connector 500 mm, surge + lamp | Silencer: Silencer SLW-8S x2 | Voltage: DC24V
CXU30-4G2RLegacy code CXU30-4G2R (previous base code; order full code above)

Need a different model, or a part not listed here? Send us your parts list →