Skip to product information
1 of 1

CKD GAMD3*2 Chemical Manifold Air Operated Valve (12 mm / 1/2")

CKD GAMD3*2 Chemical Manifold Air Operated Valve (12 mm / 1/2")

CKD GAMD3*2 Part2 chemical air-operated manifold (branch) valve with 1-5 stations on a PTFE body.

Key features

  • NC, NO and double-acting actuators on a common PTFE manifold body
  • Options: ON-OFF (0), flow adjustment (1), indicator (6)
  • A port right (standard), left (L) or both sides (W)
  • Fluid symbol (M ammonia, P nitric/HF acid, Y high temp) is written before the A-port symbol; rows list the standard version
  • High-pressure versions (suffix B: both ports 0.3 MPa, Q: 0.4 MPa) and pilot-port reinforcing ring (R) are ordered as suffixes and not expanded

Specifications

Fluid Chemicals, pure water, air, N2 gas
Fluid temperature 5-90 C (high-temp versions 5-160 C)
Proof pressure 1.0 MPa
Operating pressure A to B 0-0.3 MPa, B to A 0-0.1 MPa
Seat leakage 0 cm3/min (water pressure)
Pilot port Rc1/8
Body PTFE machined (made to order)
Operating air pressure NC/NO 0.3-0.5 MPa, double acting 0.3-0.4 MPa
Source CKD Korea catalog CB-031K-15, p. 102-109
GAMD312-12US-0-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12US-0-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12US-0-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12US-0-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12US-0-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12US-0-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12US-0-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12US-0-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12US-0-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12US-0-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12US-0-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12US-0-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12US-0-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12US-0-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12US-0-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12US-1-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12US-1-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12US-1-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12US-1-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12US-1-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12US-1-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12US-1-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12US-1-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12US-1-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12US-1-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12US-1-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12US-1-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12US-1-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12US-1-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12US-1-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12US-6-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12US-6-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12US-6-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12US-6-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12US-6-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12US-6-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12US-6-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12US-6-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12US-6-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12US-6-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12US-6-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12US-6-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12US-6-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12US-6-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12US-6-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUS-0-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUS-0-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUS-0-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUS-0-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUS-0-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUS-0-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUS-0-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUS-0-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUS-0-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUS-0-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUS-0-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUS-0-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUS-0-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUS-0-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUS-0-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUS-1-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUS-1-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUS-1-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUS-1-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUS-1-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUS-1-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUS-1-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUS-1-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUS-1-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUS-1-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUS-1-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUS-1-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUS-1-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUS-1-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUS-1-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUS-6-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUS-6-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUS-6-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUS-6-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUS-6-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUS-6-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUS-6-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUS-6-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUS-6-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUS-6-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUS-6-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUS-6-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUS-6-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUS-6-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUS-6-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UP-0-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UP-0-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UP-0-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UP-0-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UP-0-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UP-0-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UP-0-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UP-0-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UP-0-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UP-0-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UP-0-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UP-0-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UP-0-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UP-0-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UP-0-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UP-1-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UP-1-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UP-1-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UP-1-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UP-1-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UP-1-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UP-1-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UP-1-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UP-1-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UP-1-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UP-1-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UP-1-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UP-1-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UP-1-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UP-1-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UP-6-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UP-6-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UP-6-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UP-6-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UP-6-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UP-6-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UP-6-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UP-6-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UP-6-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UP-6-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UP-6-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UP-6-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UP-6-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UP-6-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UP-6-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUP-0-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUP-0-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUP-0-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUP-0-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUP-0-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUP-0-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUP-0-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUP-0-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUP-0-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUP-0-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUP-0-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUP-0-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUP-0-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUP-0-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUP-0-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUP-1-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUP-1-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUP-1-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUP-1-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUP-1-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUP-1-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUP-1-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUP-1-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUP-1-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUP-1-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUP-1-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUP-1-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUP-1-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUP-1-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUP-1-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUP-6-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUP-6-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUP-6-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUP-6-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUP-6-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUP-6-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUP-6-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUP-6-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUP-6-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUP-6-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUP-6-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUP-6-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUP-6-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUP-6-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUP-6-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UA-0-1 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UA-0-1L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UA-0-1W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UA-0-2 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UA-0-2L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UA-0-2W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UA-0-3 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UA-0-3L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UA-0-3W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UA-0-4 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UA-0-4L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UA-0-4W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UA-0-5 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UA-0-5L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UA-0-5W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UA-1-1 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UA-1-1L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UA-1-1W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UA-1-2 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UA-1-2L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UA-1-2W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UA-1-3 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UA-1-3L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UA-1-3W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UA-1-4 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UA-1-4L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UA-1-4W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UA-1-5 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UA-1-5L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UA-1-5W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UA-6-1 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UA-6-1L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UA-6-1W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UA-6-2 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UA-6-2L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UA-6-2W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UA-6-3 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UA-6-3L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UA-6-3W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UA-6-4 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UA-6-4L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UA-6-4W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UA-6-5 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UA-6-5L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UA-6-5W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUA-0-1 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUA-0-1L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUA-0-1W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUA-0-2 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUA-0-2L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUA-0-2W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUA-0-3 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUA-0-3L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUA-0-3W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUA-0-4 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUA-0-4L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUA-0-4W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUA-0-5 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUA-0-5L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUA-0-5W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUA-1-1 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUA-1-1L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUA-1-1W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUA-1-2 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUA-1-2L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUA-1-2W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUA-1-3 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUA-1-3L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUA-1-3W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUA-1-4 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUA-1-4L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUA-1-4W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUA-1-5 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUA-1-5L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUA-1-5W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUA-6-1 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUA-6-1L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUA-6-1W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUA-6-2 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUA-6-2L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUA-6-2W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUA-6-3 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUA-6-3L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUA-6-3W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUA-6-4 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUA-6-4L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUA-6-4W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUA-6-5 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUA-6-5L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUA-6-5W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UR-0-1 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UR-0-1L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UR-0-1W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UR-0-2 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UR-0-2L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UR-0-2W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UR-0-3 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UR-0-3L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UR-0-3W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UR-0-4 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UR-0-4L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UR-0-4W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UR-0-5 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UR-0-5L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UR-0-5W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UR-1-1 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UR-1-1L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UR-1-1W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UR-1-2 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UR-1-2L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UR-1-2W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UR-1-3 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UR-1-3L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UR-1-3W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UR-1-4 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UR-1-4L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UR-1-4W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UR-1-5 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UR-1-5L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UR-1-5W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UR-6-1 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UR-6-1L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UR-6-1W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UR-6-2 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UR-6-2L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UR-6-2W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UR-6-3 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UR-6-3L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UR-6-3W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UR-6-4 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UR-6-4L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UR-6-4W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UR-6-5 Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UR-6-5L Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UR-6-5W Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUR-0-1 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUR-0-1L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUR-0-1W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUR-0-2 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUR-0-2L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUR-0-2W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUR-0-3 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUR-0-3L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUR-0-3W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUR-0-4 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUR-0-4L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUR-0-4W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUR-0-5 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUR-0-5L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUR-0-5W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUR-1-1 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUR-1-1L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUR-1-1W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUR-1-2 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUR-1-2L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUR-1-2W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUR-1-3 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUR-1-3L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUR-1-3W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUR-1-4 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUR-1-4L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUR-1-4W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUR-1-5 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUR-1-5L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUR-1-5W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUR-6-1 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUR-6-1L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUR-6-1W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUR-6-2 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUR-6-2L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUR-6-2W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUR-6-3 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUR-6-3L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUR-6-3W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUR-6-4 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUR-6-4L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUR-6-4W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUR-6-5 Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUR-6-5L Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUR-6-5W Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UK-0-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UK-0-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UK-0-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UK-0-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UK-0-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UK-0-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UK-0-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UK-0-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UK-0-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UK-0-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UK-0-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UK-0-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UK-0-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UK-0-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UK-0-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UK-1-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UK-1-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UK-1-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UK-1-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UK-1-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UK-1-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UK-1-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UK-1-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UK-1-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UK-1-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UK-1-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UK-1-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UK-1-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UK-1-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UK-1-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UK-6-1 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UK-6-1L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UK-6-1W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UK-6-2 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UK-6-2L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UK-6-2W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UK-6-3 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UK-6-3L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UK-6-3W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UK-6-4 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UK-6-4L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UK-6-4W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UK-6-5 Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UK-6-5L Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UK-6-5W Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUK-0-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUK-0-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUK-0-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUK-0-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUK-0-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUK-0-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUK-0-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUK-0-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUK-0-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUK-0-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUK-0-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUK-0-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUK-0-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUK-0-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUK-0-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUK-1-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUK-1-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUK-1-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUK-1-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUK-1-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUK-1-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUK-1-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUK-1-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUK-1-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUK-1-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUK-1-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUK-1-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUK-1-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUK-1-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUK-1-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUK-6-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUK-6-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUK-6-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUK-6-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUK-6-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUK-6-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUK-6-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUK-6-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUK-6-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUK-6-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUK-6-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUK-6-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUK-6-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUK-6-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUK-6-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUW-0-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUW-0-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUW-0-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUW-0-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUW-0-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUW-0-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUW-0-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUW-0-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUW-0-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUW-0-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUW-0-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUW-0-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUW-0-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUW-0-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUW-0-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUW-1-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUW-1-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUW-1-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUW-1-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUW-1-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUW-1-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUW-1-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUW-1-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUW-1-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUW-1-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUW-1-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUW-1-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUW-1-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUW-1-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUW-1-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUW-6-1 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUW-6-1L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUW-6-1W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUW-6-2 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUW-6-2L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUW-6-2W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUW-6-3 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUW-6-3L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUW-6-3W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUW-6-4 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUW-6-4L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUW-6-4W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUW-6-5 Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUW-6-5L Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUW-6-5W Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12US-0-1 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12US-0-1L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12US-0-1W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12US-0-2 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12US-0-2L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12US-0-2W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12US-0-3 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12US-0-3L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12US-0-3W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12US-0-4 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12US-0-4L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12US-0-4W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12US-0-5 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12US-0-5L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12US-0-5W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12US-1-1 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12US-1-1L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12US-1-1W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12US-1-2 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12US-1-2L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12US-1-2W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12US-1-3 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12US-1-3L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12US-1-3W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12US-1-4 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12US-1-4L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12US-1-4W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12US-1-5 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12US-1-5L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12US-1-5W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12US-6-1 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12US-6-1L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12US-6-1W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12US-6-2 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12US-6-2L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12US-6-2W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12US-6-3 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12US-6-3L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12US-6-3W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12US-6-4 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12US-6-4L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12US-6-4W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12US-6-5 Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12US-6-5L Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12US-6-5W Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUS-0-1 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUS-0-1L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUS-0-1W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUS-0-2 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUS-0-2L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUS-0-2W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUS-0-3 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUS-0-3L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUS-0-3W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUS-0-4 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUS-0-4L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUS-0-4W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUS-0-5 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUS-0-5L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUS-0-5W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUS-1-1 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUS-1-1L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUS-1-1W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUS-1-2 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUS-1-2L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUS-1-2W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUS-1-3 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUS-1-3L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUS-1-3W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUS-1-4 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUS-1-4L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUS-1-4W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUS-1-5 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUS-1-5L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUS-1-5W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUS-6-1 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUS-6-1L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUS-6-1W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUS-6-2 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUS-6-2L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUS-6-2W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUS-6-3 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUS-6-3L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUS-6-3W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUS-6-4 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUS-6-4L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUS-6-4W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUS-6-5 Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUS-6-5L Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUS-6-5W Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UP-0-1 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UP-0-1L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UP-0-1W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UP-0-2 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UP-0-2L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UP-0-2W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UP-0-3 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UP-0-3L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UP-0-3W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UP-0-4 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UP-0-4L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UP-0-4W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UP-0-5 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UP-0-5L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UP-0-5W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UP-1-1 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UP-1-1L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UP-1-1W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UP-1-2 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UP-1-2L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UP-1-2W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UP-1-3 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UP-1-3L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UP-1-3W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UP-1-4 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UP-1-4L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UP-1-4W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UP-1-5 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UP-1-5L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UP-1-5W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UP-6-1 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UP-6-1L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UP-6-1W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UP-6-2 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UP-6-2L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UP-6-2W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UP-6-3 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UP-6-3L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UP-6-3W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UP-6-4 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UP-6-4L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UP-6-4W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UP-6-5 Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UP-6-5L Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UP-6-5W Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUP-0-1 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUP-0-1L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUP-0-1W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUP-0-2 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUP-0-2L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUP-0-2W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUP-0-3 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUP-0-3L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUP-0-3W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUP-0-4 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUP-0-4L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUP-0-4W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUP-0-5 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUP-0-5L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUP-0-5W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUP-1-1 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUP-1-1L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUP-1-1W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUP-1-2 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUP-1-2L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUP-1-2W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUP-1-3 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUP-1-3L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUP-1-3W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUP-1-4 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUP-1-4L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUP-1-4W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUP-1-5 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUP-1-5L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUP-1-5W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUP-6-1 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUP-6-1L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUP-6-1W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUP-6-2 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUP-6-2L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUP-6-2W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUP-6-3 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUP-6-3L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUP-6-3W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUP-6-4 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUP-6-4L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUP-6-4W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUP-6-5 Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUP-6-5L Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUP-6-5W Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UA-0-1 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UA-0-1L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UA-0-1W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UA-0-2 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UA-0-2L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UA-0-2W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UA-0-3 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UA-0-3L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UA-0-3W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UA-0-4 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UA-0-4L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UA-0-4W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UA-0-5 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UA-0-5L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UA-0-5W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UA-1-1 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UA-1-1L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UA-1-1W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UA-1-2 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UA-1-2L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UA-1-2W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UA-1-3 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UA-1-3L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UA-1-3W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UA-1-4 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UA-1-4L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UA-1-4W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UA-1-5 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UA-1-5L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UA-1-5W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UA-6-1 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UA-6-1L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UA-6-1W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UA-6-2 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UA-6-2L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UA-6-2W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UA-6-3 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UA-6-3L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UA-6-3W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UA-6-4 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UA-6-4L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UA-6-4W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UA-6-5 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UA-6-5L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UA-6-5W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUA-0-1 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUA-0-1L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUA-0-1W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUA-0-2 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUA-0-2L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUA-0-2W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUA-0-3 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUA-0-3L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUA-0-3W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUA-0-4 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUA-0-4L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUA-0-4W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUA-0-5 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUA-0-5L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUA-0-5W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUA-1-1 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUA-1-1L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUA-1-1W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUA-1-2 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUA-1-2L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUA-1-2W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUA-1-3 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUA-1-3L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUA-1-3W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUA-1-4 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUA-1-4L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUA-1-4W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUA-1-5 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUA-1-5L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUA-1-5W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUA-6-1 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUA-6-1L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUA-6-1W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUA-6-2 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUA-6-2L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUA-6-2W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUA-6-3 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUA-6-3L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUA-6-3W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUA-6-4 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUA-6-4L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUA-6-4W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUA-6-5 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUA-6-5L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUA-6-5W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UR-0-1 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UR-0-1L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UR-0-1W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UR-0-2 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UR-0-2L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UR-0-2W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UR-0-3 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UR-0-3L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UR-0-3W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UR-0-4 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UR-0-4L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UR-0-4W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UR-0-5 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UR-0-5L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UR-0-5W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UR-1-1 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UR-1-1L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UR-1-1W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UR-1-2 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UR-1-2L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UR-1-2W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UR-1-3 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UR-1-3L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UR-1-3W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UR-1-4 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UR-1-4L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UR-1-4W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UR-1-5 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UR-1-5L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UR-1-5W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UR-6-1 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UR-6-1L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UR-6-1W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UR-6-2 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UR-6-2L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UR-6-2W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UR-6-3 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UR-6-3L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UR-6-3W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UR-6-4 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UR-6-4L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UR-6-4W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UR-6-5 Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UR-6-5L Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UR-6-5W Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUR-0-1 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUR-0-1L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUR-0-1W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUR-0-2 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUR-0-2L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUR-0-2W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUR-0-3 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUR-0-3L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUR-0-3W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUR-0-4 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUR-0-4L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUR-0-4W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUR-0-5 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUR-0-5L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUR-0-5W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUR-1-1 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUR-1-1L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUR-1-1W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUR-1-2 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUR-1-2L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUR-1-2W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUR-1-3 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUR-1-3L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUR-1-3W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUR-1-4 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUR-1-4L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUR-1-4W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUR-1-5 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUR-1-5L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUR-1-5W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUR-6-1 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUR-6-1L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUR-6-1W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUR-6-2 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUR-6-2L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUR-6-2W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUR-6-3 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUR-6-3L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUR-6-3W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUR-6-4 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUR-6-4L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUR-6-4W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUR-6-5 Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUR-6-5L Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUR-6-5W Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UK-0-1 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UK-0-1L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UK-0-1W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UK-0-2 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UK-0-2L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UK-0-2W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UK-0-3 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UK-0-3L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UK-0-3W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UK-0-4 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UK-0-4L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UK-0-4W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UK-0-5 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UK-0-5L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UK-0-5W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UK-1-1 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UK-1-1L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UK-1-1W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UK-1-2 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UK-1-2L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UK-1-2W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UK-1-3 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UK-1-3L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UK-1-3W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UK-1-4 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UK-1-4L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UK-1-4W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UK-1-5 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UK-1-5L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UK-1-5W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UK-6-1 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UK-6-1L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UK-6-1W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UK-6-2 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UK-6-2L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UK-6-2W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UK-6-3 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UK-6-3L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UK-6-3W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UK-6-4 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UK-6-4L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UK-6-4W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UK-6-5 Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UK-6-5L Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UK-6-5W Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUK-0-1 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUK-0-1L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUK-0-1W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUK-0-2 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUK-0-2L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUK-0-2W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUK-0-3 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUK-0-3L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUK-0-3W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUK-0-4 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUK-0-4L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUK-0-4W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUK-0-5 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUK-0-5L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUK-0-5W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUK-1-1 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUK-1-1L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUK-1-1W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUK-1-2 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUK-1-2L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUK-1-2W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUK-1-3 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUK-1-3L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUK-1-3W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUK-1-4 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUK-1-4L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUK-1-4W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUK-1-5 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUK-1-5L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUK-1-5W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUK-6-1 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUK-6-1L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUK-6-1W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUK-6-2 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUK-6-2L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUK-6-2W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUK-6-3 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUK-6-3L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUK-6-3W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUK-6-4 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUK-6-4L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUK-6-4W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUK-6-5 Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUK-6-5L Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUK-6-5W Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUW-0-1 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUW-0-1L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUW-0-1W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUW-0-2 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUW-0-2L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUW-0-2W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUW-0-3 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUW-0-3L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUW-0-3W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUW-0-4 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUW-0-4L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUW-0-4W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUW-0-5 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUW-0-5L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUW-0-5W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUW-1-1 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUW-1-1L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUW-1-1W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUW-1-2 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUW-1-2L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUW-1-2W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUW-1-3 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUW-1-3L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUW-1-3W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUW-1-4 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUW-1-4L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUW-1-4W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUW-1-5 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUW-1-5L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUW-1-5W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUW-6-1 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUW-6-1L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUW-6-1W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUW-6-2 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUW-6-2L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUW-6-2W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUW-6-3 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUW-6-3L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUW-6-3W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUW-6-4 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUW-6-4L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUW-6-4W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUW-6-5 Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUW-6-5L Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUW-6-5W Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12US-0-1 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12US-0-1L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12US-0-1W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12US-0-2 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12US-0-2L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12US-0-2W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12US-0-3 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12US-0-3L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12US-0-3W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12US-0-4 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12US-0-4L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12US-0-4W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12US-0-5 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12US-0-5L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12US-0-5W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12US-1-1 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12US-1-1L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12US-1-1W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12US-1-2 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12US-1-2L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12US-1-2W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12US-1-3 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12US-1-3L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12US-1-3W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12US-1-4 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12US-1-4L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12US-1-4W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12US-1-5 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12US-1-5L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12US-1-5W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12US-6-1 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12US-6-1L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12US-6-1W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12US-6-2 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12US-6-2L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12US-6-2W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12US-6-3 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12US-6-3L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12US-6-3W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12US-6-4 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12US-6-4L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12US-6-4W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12US-6-5 Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12US-6-5L Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12US-6-5W Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUS-0-1 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUS-0-1L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUS-0-1W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUS-0-2 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUS-0-2L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUS-0-2W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUS-0-3 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUS-0-3L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUS-0-3W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUS-0-4 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUS-0-4L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUS-0-4W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUS-0-5 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUS-0-5L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUS-0-5W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUS-1-1 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUS-1-1L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUS-1-1W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUS-1-2 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUS-1-2L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUS-1-2W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUS-1-3 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUS-1-3L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUS-1-3W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUS-1-4 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUS-1-4L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUS-1-4W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUS-1-5 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUS-1-5L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUS-1-5W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUS-6-1 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUS-6-1L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUS-6-1W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUS-6-2 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUS-6-2L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUS-6-2W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUS-6-3 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUS-6-3L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUS-6-3W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUS-6-4 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUS-6-4L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUS-6-4W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUS-6-5 Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUS-6-5L Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUS-6-5W Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UP-0-1 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UP-0-1L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UP-0-1W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UP-0-2 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UP-0-2L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UP-0-2W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UP-0-3 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UP-0-3L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UP-0-3W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UP-0-4 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UP-0-4L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UP-0-4W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UP-0-5 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UP-0-5L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UP-0-5W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UP-1-1 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UP-1-1L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UP-1-1W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UP-1-2 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UP-1-2L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UP-1-2W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UP-1-3 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UP-1-3L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UP-1-3W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UP-1-4 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UP-1-4L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UP-1-4W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UP-1-5 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UP-1-5L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UP-1-5W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UP-6-1 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UP-6-1L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UP-6-1W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UP-6-2 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UP-6-2L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UP-6-2W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UP-6-3 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UP-6-3L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UP-6-3W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UP-6-4 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UP-6-4L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UP-6-4W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UP-6-5 Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UP-6-5L Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UP-6-5W Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUP-0-1 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUP-0-1L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUP-0-1W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUP-0-2 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUP-0-2L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUP-0-2W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUP-0-3 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUP-0-3L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUP-0-3W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUP-0-4 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUP-0-4L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUP-0-4W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUP-0-5 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUP-0-5L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUP-0-5W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUP-1-1 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUP-1-1L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUP-1-1W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUP-1-2 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUP-1-2L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUP-1-2W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUP-1-3 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUP-1-3L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUP-1-3W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUP-1-4 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUP-1-4L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUP-1-4W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUP-1-5 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUP-1-5L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUP-1-5W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUP-6-1 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUP-6-1L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUP-6-1W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUP-6-2 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUP-6-2L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUP-6-2W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUP-6-3 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUP-6-3L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUP-6-3W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUP-6-4 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUP-6-4L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUP-6-4W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUP-6-5 Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUP-6-5L Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUP-6-5W Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UA-0-1 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UA-0-1L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UA-0-1W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UA-0-2 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UA-0-2L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UA-0-2W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UA-0-3 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UA-0-3L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UA-0-3W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UA-0-4 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UA-0-4L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UA-0-4W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UA-0-5 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UA-0-5L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UA-0-5W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UA-1-1 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UA-1-1L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UA-1-1W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UA-1-2 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UA-1-2L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UA-1-2W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UA-1-3 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UA-1-3L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UA-1-3W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UA-1-4 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UA-1-4L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UA-1-4W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UA-1-5 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UA-1-5L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UA-1-5W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UA-6-1 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UA-6-1L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UA-6-1W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UA-6-2 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UA-6-2L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UA-6-2W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UA-6-3 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UA-6-3L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UA-6-3W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UA-6-4 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UA-6-4L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UA-6-4W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UA-6-5 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UA-6-5L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UA-6-5W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUA-0-1 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUA-0-1L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUA-0-1W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUA-0-2 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUA-0-2L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUA-0-2W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUA-0-3 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUA-0-3L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUA-0-3W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUA-0-4 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUA-0-4L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUA-0-4W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUA-0-5 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUA-0-5L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUA-0-5W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUA-1-1 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUA-1-1L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUA-1-1W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUA-1-2 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUA-1-2L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUA-1-2W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUA-1-3 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUA-1-3L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUA-1-3W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUA-1-4 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUA-1-4L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUA-1-4W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUA-1-5 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUA-1-5L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUA-1-5W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUA-6-1 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUA-6-1L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUA-6-1W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUA-6-2 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUA-6-2L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUA-6-2W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUA-6-3 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUA-6-3L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUA-6-3W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUA-6-4 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUA-6-4L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUA-6-4W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUA-6-5 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUA-6-5L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUA-6-5W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UR-0-1 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UR-0-1L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UR-0-1W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UR-0-2 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UR-0-2L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UR-0-2W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UR-0-3 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UR-0-3L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UR-0-3W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UR-0-4 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UR-0-4L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UR-0-4W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UR-0-5 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UR-0-5L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UR-0-5W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UR-1-1 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UR-1-1L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UR-1-1W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UR-1-2 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UR-1-2L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UR-1-2W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UR-1-3 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UR-1-3L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UR-1-3W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UR-1-4 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UR-1-4L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UR-1-4W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UR-1-5 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UR-1-5L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UR-1-5W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UR-6-1 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UR-6-1L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UR-6-1W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UR-6-2 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UR-6-2L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UR-6-2W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UR-6-3 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UR-6-3L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UR-6-3W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UR-6-4 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UR-6-4L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UR-6-4W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UR-6-5 Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UR-6-5L Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UR-6-5W Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUR-0-1 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUR-0-1L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUR-0-1W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUR-0-2 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUR-0-2L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUR-0-2W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUR-0-3 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUR-0-3L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUR-0-3W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUR-0-4 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUR-0-4L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUR-0-4W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUR-0-5 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUR-0-5L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUR-0-5W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUR-1-1 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUR-1-1L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUR-1-1W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUR-1-2 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUR-1-2L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUR-1-2W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUR-1-3 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUR-1-3L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUR-1-3W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUR-1-4 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUR-1-4L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUR-1-4W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUR-1-5 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUR-1-5L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUR-1-5W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUR-6-1 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUR-6-1L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUR-6-1W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUR-6-2 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUR-6-2L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUR-6-2W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUR-6-3 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUR-6-3L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUR-6-3W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUR-6-4 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUR-6-4L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUR-6-4W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUR-6-5 Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUR-6-5L Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUR-6-5W Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UK-0-1 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UK-0-1L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UK-0-1W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UK-0-2 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UK-0-2L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UK-0-2W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UK-0-3 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UK-0-3L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UK-0-3W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UK-0-4 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UK-0-4L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UK-0-4W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UK-0-5 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UK-0-5L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UK-0-5W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UK-1-1 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UK-1-1L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UK-1-1W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UK-1-2 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UK-1-2L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UK-1-2W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UK-1-3 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UK-1-3L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UK-1-3W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UK-1-4 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UK-1-4L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UK-1-4W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UK-1-5 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UK-1-5L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UK-1-5W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UK-6-1 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UK-6-1L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UK-6-1W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UK-6-2 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UK-6-2L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UK-6-2W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UK-6-3 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UK-6-3L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UK-6-3W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UK-6-4 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UK-6-4L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UK-6-4W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UK-6-5 Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UK-6-5L Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UK-6-5W Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUK-0-1 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUK-0-1L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUK-0-1W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUK-0-2 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUK-0-2L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUK-0-2W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUK-0-3 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUK-0-3L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUK-0-3W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUK-0-4 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUK-0-4L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUK-0-4W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUK-0-5 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUK-0-5L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUK-0-5W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUK-1-1 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUK-1-1L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUK-1-1W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUK-1-2 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUK-1-2L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUK-1-2W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUK-1-3 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUK-1-3L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUK-1-3W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUK-1-4 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUK-1-4L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUK-1-4W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUK-1-5 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUK-1-5L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUK-1-5W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUK-6-1 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUK-6-1L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUK-6-1W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUK-6-2 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUK-6-2L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUK-6-2W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUK-6-3 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUK-6-3L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUK-6-3W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUK-6-4 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUK-6-4L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUK-6-4W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUK-6-5 Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUK-6-5L Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUK-6-5W Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUW-0-1 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUW-0-1L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUW-0-1W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUW-0-2 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUW-0-2L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUW-0-2W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUW-0-3 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUW-0-3L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUW-0-3W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUW-0-4 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUW-0-4L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUW-0-4W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUW-0-5 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUW-0-5L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUW-0-5W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUW-1-1 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUW-1-1L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUW-1-1W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUW-1-2 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUW-1-2L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUW-1-2W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUW-1-3 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUW-1-3L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUW-1-3W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUW-1-4 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUW-1-4L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUW-1-4W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUW-1-5 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUW-1-5L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUW-1-5W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUW-6-1 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUW-6-1L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUW-6-1W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUW-6-2 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUW-6-2L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUW-6-2W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUW-6-3 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUW-6-3L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUW-6-3W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUW-6-4 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUW-6-4L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUW-6-4W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUW-6-5 Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUW-6-5L Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUW-6-5W Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
Air Operated ValvesCKD
1485 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

CKD GAMD3*2 Chemical Manifold Air Operated Valve (12 mm / 1/2")

Brand CKD·Air Operated Valves

Available part numbers (1485)

GAMD312-12US-0-1, GAMD312-12US-0-1L, GAMD312-12US-0-1W, GAMD312-12US-0-2, GAMD312-12US-0-2L, GAMD312-12US-0-2W, GAMD312-12US-0-3, GAMD312-12US-0-3L, GAMD312-12US-0-3W, GAMD312-12US-0-4 + 1475 more — see full table ↓

How to order

Send the CKD part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
GAMD312-12US-0-1Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12US-0-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12US-0-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12US-0-2Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12US-0-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12US-0-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12US-0-3Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12US-0-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12US-0-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12US-0-4Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12US-0-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12US-0-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12US-0-5Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12US-0-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12US-0-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12US-1-1Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12US-1-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12US-1-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12US-1-2Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12US-1-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12US-1-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12US-1-3Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12US-1-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12US-1-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12US-1-4Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12US-1-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12US-1-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12US-1-5Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12US-1-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12US-1-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12US-6-1Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12US-6-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12US-6-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12US-6-2Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12US-6-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12US-6-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12US-6-3Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12US-6-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12US-6-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12US-6-4Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12US-6-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12US-6-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12US-6-5Action: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12US-6-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12US-6-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUS-0-1Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUS-0-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUS-0-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUS-0-2Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUS-0-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUS-0-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUS-0-3Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUS-0-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUS-0-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUS-0-4Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUS-0-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUS-0-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUS-0-5Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUS-0-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUS-0-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUS-1-1Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUS-1-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUS-1-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUS-1-2Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUS-1-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUS-1-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUS-1-3Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUS-1-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUS-1-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUS-1-4Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUS-1-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUS-1-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUS-1-5Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUS-1-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUS-1-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUS-6-1Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUS-6-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUS-6-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUS-6-2Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUS-6-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUS-6-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUS-6-3Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUS-6-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUS-6-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUS-6-4Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUS-6-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUS-6-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUS-6-5Action: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUS-6-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUS-6-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UP-0-1Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UP-0-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UP-0-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UP-0-2Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UP-0-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UP-0-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UP-0-3Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UP-0-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UP-0-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UP-0-4Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UP-0-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UP-0-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UP-0-5Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UP-0-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UP-0-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UP-1-1Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UP-1-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UP-1-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UP-1-2Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UP-1-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UP-1-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UP-1-3Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UP-1-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UP-1-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UP-1-4Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UP-1-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UP-1-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UP-1-5Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UP-1-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UP-1-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UP-6-1Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UP-6-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UP-6-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UP-6-2Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UP-6-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UP-6-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UP-6-3Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UP-6-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UP-6-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UP-6-4Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UP-6-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UP-6-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UP-6-5Action: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UP-6-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UP-6-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUP-0-1Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUP-0-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUP-0-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUP-0-2Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUP-0-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUP-0-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUP-0-3Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUP-0-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUP-0-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUP-0-4Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUP-0-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUP-0-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUP-0-5Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUP-0-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUP-0-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUP-1-1Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUP-1-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUP-1-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUP-1-2Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUP-1-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUP-1-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUP-1-3Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUP-1-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUP-1-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUP-1-4Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUP-1-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUP-1-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUP-1-5Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUP-1-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUP-1-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUP-6-1Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUP-6-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUP-6-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUP-6-2Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUP-6-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUP-6-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUP-6-3Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUP-6-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUP-6-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUP-6-4Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUP-6-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUP-6-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUP-6-5Action: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUP-6-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUP-6-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UA-0-1Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UA-0-1LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UA-0-1WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UA-0-2Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UA-0-2LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UA-0-2WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UA-0-3Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UA-0-3LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UA-0-3WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UA-0-4Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UA-0-4LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UA-0-4WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UA-0-5Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UA-0-5LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UA-0-5WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UA-1-1Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UA-1-1LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UA-1-1WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UA-1-2Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UA-1-2LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UA-1-2WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UA-1-3Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UA-1-3LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UA-1-3WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UA-1-4Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UA-1-4LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UA-1-4WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UA-1-5Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UA-1-5LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UA-1-5WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UA-6-1Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UA-6-1LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UA-6-1WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UA-6-2Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UA-6-2LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UA-6-2WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UA-6-3Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UA-6-3LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UA-6-3WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UA-6-4Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UA-6-4LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UA-6-4WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UA-6-5Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UA-6-5LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UA-6-5WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUA-0-1Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUA-0-1LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUA-0-1WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUA-0-2Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUA-0-2LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUA-0-2WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUA-0-3Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUA-0-3LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUA-0-3WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUA-0-4Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUA-0-4LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUA-0-4WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUA-0-5Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUA-0-5LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUA-0-5WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUA-1-1Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUA-1-1LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUA-1-1WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUA-1-2Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUA-1-2LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUA-1-2WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUA-1-3Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUA-1-3LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUA-1-3WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUA-1-4Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUA-1-4LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUA-1-4WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUA-1-5Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUA-1-5LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUA-1-5WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUA-6-1Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUA-6-1LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUA-6-1WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUA-6-2Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUA-6-2LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUA-6-2WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUA-6-3Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUA-6-3LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUA-6-3WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUA-6-4Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUA-6-4LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUA-6-4WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUA-6-5Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUA-6-5LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUA-6-5WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UR-0-1Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UR-0-1LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UR-0-1WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UR-0-2Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UR-0-2LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UR-0-2WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UR-0-3Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UR-0-3LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UR-0-3WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UR-0-4Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UR-0-4LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UR-0-4WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UR-0-5Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UR-0-5LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UR-0-5WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UR-1-1Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UR-1-1LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UR-1-1WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UR-1-2Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UR-1-2LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UR-1-2WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UR-1-3Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UR-1-3LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UR-1-3WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UR-1-4Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UR-1-4LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UR-1-4WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UR-1-5Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UR-1-5LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UR-1-5WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UR-6-1Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UR-6-1LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UR-6-1WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UR-6-2Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UR-6-2LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UR-6-2WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UR-6-3Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UR-6-3LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UR-6-3WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UR-6-4Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UR-6-4LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UR-6-4WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UR-6-5Action: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UR-6-5LAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UR-6-5WAction: NC (normally closed) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUR-0-1Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUR-0-1LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUR-0-1WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUR-0-2Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUR-0-2LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUR-0-2WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUR-0-3Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUR-0-3LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUR-0-3WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUR-0-4Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUR-0-4LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUR-0-4WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUR-0-5Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUR-0-5LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUR-0-5WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUR-1-1Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUR-1-1LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUR-1-1WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUR-1-2Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUR-1-2LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUR-1-2WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUR-1-3Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUR-1-3LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUR-1-3WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUR-1-4Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUR-1-4LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUR-1-4WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUR-1-5Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUR-1-5LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUR-1-5WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUR-6-1Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUR-6-1LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUR-6-1WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUR-6-2Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUR-6-2LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUR-6-2WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUR-6-3Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUR-6-3LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUR-6-3WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUR-6-4Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUR-6-4LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUR-6-4WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUR-6-5Action: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUR-6-5LAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUR-6-5WAction: NC (normally closed) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-12UK-0-1Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-12UK-0-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-12UK-0-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-12UK-0-2Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-12UK-0-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-12UK-0-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-12UK-0-3Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-12UK-0-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-12UK-0-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-12UK-0-4Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-12UK-0-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-12UK-0-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-12UK-0-5Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-12UK-0-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-12UK-0-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-12UK-1-1Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-12UK-1-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-12UK-1-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-12UK-1-2Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-12UK-1-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-12UK-1-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-12UK-1-3Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-12UK-1-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-12UK-1-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-12UK-1-4Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-12UK-1-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-12UK-1-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-12UK-1-5Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-12UK-1-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-12UK-1-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-12UK-6-1Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-12UK-6-1LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-12UK-6-1WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-12UK-6-2Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-12UK-6-2LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-12UK-6-2WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-12UK-6-3Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-12UK-6-3LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-12UK-6-3WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-12UK-6-4Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-12UK-6-4LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-12UK-6-4WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-12UK-6-5Action: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-12UK-6-5LAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-12UK-6-5WAction: NC (normally closed) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUK-0-1Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUK-0-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUK-0-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUK-0-2Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUK-0-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUK-0-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUK-0-3Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUK-0-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUK-0-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUK-0-4Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUK-0-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUK-0-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUK-0-5Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUK-0-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUK-0-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUK-1-1Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUK-1-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUK-1-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUK-1-2Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUK-1-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUK-1-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUK-1-3Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUK-1-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUK-1-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUK-1-4Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUK-1-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUK-1-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUK-1-5Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUK-1-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUK-1-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUK-6-1Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUK-6-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUK-6-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUK-6-2Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUK-6-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUK-6-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUK-6-3Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUK-6-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUK-6-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUK-6-4Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUK-6-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUK-6-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUK-6-5Action: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUK-6-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUK-6-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD312-15BUW-0-1Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD312-15BUW-0-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD312-15BUW-0-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD312-15BUW-0-2Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD312-15BUW-0-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD312-15BUW-0-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD312-15BUW-0-3Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD312-15BUW-0-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD312-15BUW-0-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD312-15BUW-0-4Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD312-15BUW-0-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD312-15BUW-0-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD312-15BUW-0-5Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD312-15BUW-0-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD312-15BUW-0-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD312-15BUW-1-1Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD312-15BUW-1-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD312-15BUW-1-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD312-15BUW-1-2Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD312-15BUW-1-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD312-15BUW-1-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD312-15BUW-1-3Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD312-15BUW-1-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD312-15BUW-1-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD312-15BUW-1-4Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD312-15BUW-1-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD312-15BUW-1-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD312-15BUW-1-5Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD312-15BUW-1-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD312-15BUW-1-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD312-15BUW-6-1Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD312-15BUW-6-1LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD312-15BUW-6-1WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD312-15BUW-6-2Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD312-15BUW-6-2LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD312-15BUW-6-2WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD312-15BUW-6-3Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD312-15BUW-6-3LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD312-15BUW-6-3WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD312-15BUW-6-4Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD312-15BUW-6-4LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD312-15BUW-6-4WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD312-15BUW-6-5Action: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD312-15BUW-6-5LAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD312-15BUW-6-5WAction: NC (normally closed) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12US-0-1Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12US-0-1LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12US-0-1WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12US-0-2Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12US-0-2LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12US-0-2WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12US-0-3Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12US-0-3LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12US-0-3WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12US-0-4Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12US-0-4LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12US-0-4WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12US-0-5Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12US-0-5LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12US-0-5WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12US-1-1Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12US-1-1LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12US-1-1WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12US-1-2Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12US-1-2LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12US-1-2WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12US-1-3Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12US-1-3LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12US-1-3WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12US-1-4Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12US-1-4LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12US-1-4WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12US-1-5Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12US-1-5LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12US-1-5WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12US-6-1Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12US-6-1LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12US-6-1WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12US-6-2Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12US-6-2LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12US-6-2WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12US-6-3Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12US-6-3LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12US-6-3WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12US-6-4Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12US-6-4LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12US-6-4WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12US-6-5Action: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12US-6-5LAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12US-6-5WAction: NO (normally open) | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUS-0-1Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUS-0-1LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUS-0-1WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUS-0-2Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUS-0-2LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUS-0-2WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUS-0-3Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUS-0-3LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUS-0-3WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUS-0-4Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUS-0-4LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUS-0-4WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUS-0-5Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUS-0-5LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUS-0-5WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUS-1-1Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUS-1-1LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUS-1-1WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUS-1-2Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUS-1-2LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUS-1-2WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUS-1-3Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUS-1-3LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUS-1-3WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUS-1-4Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUS-1-4LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUS-1-4WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUS-1-5Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUS-1-5LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUS-1-5WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUS-6-1Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUS-6-1LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUS-6-1WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUS-6-2Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUS-6-2LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUS-6-2WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUS-6-3Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUS-6-3LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUS-6-3WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUS-6-4Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUS-6-4LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUS-6-4WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUS-6-5Action: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUS-6-5LAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUS-6-5WAction: NO (normally open) | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UP-0-1Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UP-0-1LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UP-0-1WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UP-0-2Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UP-0-2LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UP-0-2WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UP-0-3Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UP-0-3LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UP-0-3WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UP-0-4Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UP-0-4LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UP-0-4WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UP-0-5Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UP-0-5LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UP-0-5WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UP-1-1Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UP-1-1LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UP-1-1WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UP-1-2Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UP-1-2LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UP-1-2WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UP-1-3Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UP-1-3LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UP-1-3WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UP-1-4Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UP-1-4LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UP-1-4WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UP-1-5Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UP-1-5LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UP-1-5WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UP-6-1Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UP-6-1LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UP-6-1WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UP-6-2Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UP-6-2LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UP-6-2WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UP-6-3Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UP-6-3LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UP-6-3WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UP-6-4Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UP-6-4LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UP-6-4WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UP-6-5Action: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UP-6-5LAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UP-6-5WAction: NO (normally open) | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUP-0-1Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUP-0-1LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUP-0-1WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUP-0-2Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUP-0-2LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUP-0-2WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUP-0-3Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUP-0-3LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUP-0-3WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUP-0-4Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUP-0-4LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUP-0-4WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUP-0-5Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUP-0-5LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUP-0-5WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUP-1-1Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUP-1-1LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUP-1-1WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUP-1-2Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUP-1-2LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUP-1-2WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUP-1-3Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUP-1-3LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUP-1-3WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUP-1-4Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUP-1-4LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUP-1-4WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUP-1-5Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUP-1-5LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUP-1-5WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUP-6-1Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUP-6-1LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUP-6-1WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUP-6-2Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUP-6-2LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUP-6-2WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUP-6-3Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUP-6-3LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUP-6-3WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUP-6-4Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUP-6-4LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUP-6-4WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUP-6-5Action: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUP-6-5LAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUP-6-5WAction: NO (normally open) | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UA-0-1Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UA-0-1LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UA-0-1WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UA-0-2Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UA-0-2LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UA-0-2WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UA-0-3Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UA-0-3LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UA-0-3WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UA-0-4Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UA-0-4LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UA-0-4WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UA-0-5Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UA-0-5LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UA-0-5WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UA-1-1Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UA-1-1LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UA-1-1WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UA-1-2Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UA-1-2LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UA-1-2WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UA-1-3Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UA-1-3LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UA-1-3WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UA-1-4Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UA-1-4LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UA-1-4WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UA-1-5Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UA-1-5LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UA-1-5WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UA-6-1Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UA-6-1LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UA-6-1WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UA-6-2Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UA-6-2LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UA-6-2WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UA-6-3Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UA-6-3LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UA-6-3WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UA-6-4Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UA-6-4LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UA-6-4WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UA-6-5Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UA-6-5LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UA-6-5WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUA-0-1Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUA-0-1LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUA-0-1WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUA-0-2Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUA-0-2LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUA-0-2WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUA-0-3Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUA-0-3LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUA-0-3WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUA-0-4Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUA-0-4LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUA-0-4WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUA-0-5Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUA-0-5LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUA-0-5WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUA-1-1Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUA-1-1LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUA-1-1WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUA-1-2Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUA-1-2LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUA-1-2WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUA-1-3Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUA-1-3LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUA-1-3WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUA-1-4Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUA-1-4LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUA-1-4WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUA-1-5Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUA-1-5LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUA-1-5WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUA-6-1Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUA-6-1LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUA-6-1WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUA-6-2Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUA-6-2LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUA-6-2WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUA-6-3Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUA-6-3LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUA-6-3WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUA-6-4Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUA-6-4LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUA-6-4WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUA-6-5Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUA-6-5LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUA-6-5WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UR-0-1Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UR-0-1LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UR-0-1WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UR-0-2Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UR-0-2LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UR-0-2WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UR-0-3Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UR-0-3LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UR-0-3WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UR-0-4Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UR-0-4LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UR-0-4WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UR-0-5Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UR-0-5LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UR-0-5WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UR-1-1Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UR-1-1LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UR-1-1WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UR-1-2Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UR-1-2LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UR-1-2WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UR-1-3Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UR-1-3LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UR-1-3WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UR-1-4Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UR-1-4LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UR-1-4WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UR-1-5Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UR-1-5LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UR-1-5WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UR-6-1Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UR-6-1LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UR-6-1WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UR-6-2Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UR-6-2LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UR-6-2WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UR-6-3Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UR-6-3LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UR-6-3WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UR-6-4Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UR-6-4LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UR-6-4WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UR-6-5Action: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UR-6-5LAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UR-6-5WAction: NO (normally open) | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUR-0-1Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUR-0-1LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUR-0-1WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUR-0-2Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUR-0-2LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUR-0-2WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUR-0-3Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUR-0-3LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUR-0-3WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUR-0-4Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUR-0-4LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUR-0-4WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUR-0-5Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUR-0-5LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUR-0-5WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUR-1-1Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUR-1-1LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUR-1-1WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUR-1-2Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUR-1-2LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUR-1-2WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUR-1-3Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUR-1-3LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUR-1-3WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUR-1-4Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUR-1-4LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUR-1-4WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUR-1-5Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUR-1-5LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUR-1-5WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUR-6-1Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUR-6-1LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUR-6-1WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUR-6-2Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUR-6-2LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUR-6-2WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUR-6-3Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUR-6-3LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUR-6-3WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUR-6-4Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUR-6-4LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUR-6-4WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUR-6-5Action: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUR-6-5LAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUR-6-5WAction: NO (normally open) | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-12UK-0-1Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-12UK-0-1LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-12UK-0-1WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-12UK-0-2Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-12UK-0-2LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-12UK-0-2WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-12UK-0-3Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-12UK-0-3LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-12UK-0-3WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-12UK-0-4Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-12UK-0-4LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-12UK-0-4WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-12UK-0-5Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-12UK-0-5LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-12UK-0-5WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-12UK-1-1Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-12UK-1-1LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-12UK-1-1WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-12UK-1-2Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-12UK-1-2LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-12UK-1-2WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-12UK-1-3Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-12UK-1-3LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-12UK-1-3WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-12UK-1-4Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-12UK-1-4LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-12UK-1-4WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-12UK-1-5Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-12UK-1-5LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-12UK-1-5WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-12UK-6-1Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-12UK-6-1LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-12UK-6-1WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-12UK-6-2Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-12UK-6-2LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-12UK-6-2WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-12UK-6-3Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-12UK-6-3LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-12UK-6-3WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-12UK-6-4Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-12UK-6-4LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-12UK-6-4WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-12UK-6-5Action: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-12UK-6-5LAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-12UK-6-5WAction: NO (normally open) | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUK-0-1Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUK-0-1LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUK-0-1WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUK-0-2Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUK-0-2LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUK-0-2WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUK-0-3Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUK-0-3LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUK-0-3WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUK-0-4Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUK-0-4LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUK-0-4WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUK-0-5Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUK-0-5LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUK-0-5WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUK-1-1Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUK-1-1LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUK-1-1WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUK-1-2Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUK-1-2LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUK-1-2WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUK-1-3Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUK-1-3LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUK-1-3WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUK-1-4Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUK-1-4LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUK-1-4WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUK-1-5Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUK-1-5LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUK-1-5WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUK-6-1Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUK-6-1LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUK-6-1WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUK-6-2Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUK-6-2LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUK-6-2WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUK-6-3Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUK-6-3LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUK-6-3WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUK-6-4Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUK-6-4LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUK-6-4WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUK-6-5Action: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUK-6-5LAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUK-6-5WAction: NO (normally open) | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD322-15BUW-0-1Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD322-15BUW-0-1LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD322-15BUW-0-1WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD322-15BUW-0-2Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD322-15BUW-0-2LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD322-15BUW-0-2WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD322-15BUW-0-3Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD322-15BUW-0-3LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD322-15BUW-0-3WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD322-15BUW-0-4Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD322-15BUW-0-4LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD322-15BUW-0-4WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD322-15BUW-0-5Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD322-15BUW-0-5LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD322-15BUW-0-5WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD322-15BUW-1-1Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD322-15BUW-1-1LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD322-15BUW-1-1WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD322-15BUW-1-2Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD322-15BUW-1-2LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD322-15BUW-1-2WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD322-15BUW-1-3Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD322-15BUW-1-3LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD322-15BUW-1-3WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD322-15BUW-1-4Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD322-15BUW-1-4LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD322-15BUW-1-4WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD322-15BUW-1-5Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD322-15BUW-1-5LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD322-15BUW-1-5WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD322-15BUW-6-1Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD322-15BUW-6-1LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD322-15BUW-6-1WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD322-15BUW-6-2Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD322-15BUW-6-2LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD322-15BUW-6-2WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD322-15BUW-6-3Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD322-15BUW-6-3LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD322-15BUW-6-3WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD322-15BUW-6-4Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD322-15BUW-6-4LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD322-15BUW-6-4WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD322-15BUW-6-5Action: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD322-15BUW-6-5LAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD322-15BUW-6-5WAction: NO (normally open) | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12US-0-1Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12US-0-1LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12US-0-1WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12US-0-2Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12US-0-2LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12US-0-2WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12US-0-3Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12US-0-3LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12US-0-3WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12US-0-4Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12US-0-4LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12US-0-4WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12US-0-5Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12US-0-5LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12US-0-5WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12US-1-1Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12US-1-1LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12US-1-1WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12US-1-2Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12US-1-2LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12US-1-2WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12US-1-3Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12US-1-3LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12US-1-3WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12US-1-4Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12US-1-4LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12US-1-4WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12US-1-5Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12US-1-5LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12US-1-5WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12US-6-1Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12US-6-1LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12US-6-1WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12US-6-2Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12US-6-2LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12US-6-2WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12US-6-3Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12US-6-3LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12US-6-3WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12US-6-4Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12US-6-4LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12US-6-4WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12US-6-5Action: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12US-6-5LAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12US-6-5WAction: Double acting | Connection: OD 12 mm tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUS-0-1Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUS-0-1LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUS-0-1WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUS-0-2Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUS-0-2LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUS-0-2WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUS-0-3Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUS-0-3LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUS-0-3WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUS-0-4Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUS-0-4LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUS-0-4WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUS-0-5Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUS-0-5LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUS-0-5WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUS-1-1Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUS-1-1LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUS-1-1WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUS-1-2Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUS-1-2LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUS-1-2WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUS-1-3Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUS-1-3LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUS-1-3WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUS-1-4Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUS-1-4LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUS-1-4WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUS-1-5Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUS-1-5LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUS-1-5WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUS-6-1Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUS-6-1LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUS-6-1WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUS-6-2Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUS-6-2LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUS-6-2WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUS-6-3Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUS-6-3LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUS-6-3WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUS-6-4Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUS-6-4LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUS-6-4WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUS-6-5Action: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUS-6-5LAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUS-6-5WAction: Double acting | Connection: OD 1/2" tube, Super pillar | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UP-0-1Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UP-0-1LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UP-0-1WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UP-0-2Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UP-0-2LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UP-0-2WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UP-0-3Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UP-0-3LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UP-0-3WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UP-0-4Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UP-0-4LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UP-0-4WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UP-0-5Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UP-0-5LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UP-0-5WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UP-1-1Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UP-1-1LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UP-1-1WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UP-1-2Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UP-1-2LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UP-1-2WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UP-1-3Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UP-1-3LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UP-1-3WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UP-1-4Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UP-1-4LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UP-1-4WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UP-1-5Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UP-1-5LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UP-1-5WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UP-6-1Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UP-6-1LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UP-6-1WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UP-6-2Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UP-6-2LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UP-6-2WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UP-6-3Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UP-6-3LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UP-6-3WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UP-6-4Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UP-6-4LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UP-6-4WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UP-6-5Action: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UP-6-5LAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UP-6-5WAction: Double acting | Connection: OD 12 mm tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUP-0-1Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUP-0-1LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUP-0-1WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUP-0-2Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUP-0-2LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUP-0-2WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUP-0-3Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUP-0-3LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUP-0-3WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUP-0-4Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUP-0-4LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUP-0-4WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUP-0-5Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUP-0-5LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUP-0-5WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUP-1-1Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUP-1-1LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUP-1-1WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUP-1-2Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUP-1-2LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUP-1-2WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUP-1-3Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUP-1-3LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUP-1-3WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUP-1-4Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUP-1-4LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUP-1-4WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUP-1-5Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUP-1-5LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUP-1-5WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUP-6-1Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUP-6-1LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUP-6-1WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUP-6-2Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUP-6-2LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUP-6-2WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUP-6-3Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUP-6-3LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUP-6-3WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUP-6-4Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUP-6-4LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUP-6-4WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUP-6-5Action: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUP-6-5LAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUP-6-5WAction: Double acting | Connection: OD 1/2" tube, Super 300 P | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UA-0-1Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UA-0-1LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UA-0-1WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UA-0-2Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UA-0-2LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UA-0-2WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UA-0-3Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UA-0-3LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UA-0-3WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UA-0-4Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UA-0-4LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UA-0-4WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UA-0-5Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UA-0-5LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UA-0-5WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UA-1-1Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UA-1-1LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UA-1-1WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UA-1-2Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UA-1-2LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UA-1-2WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UA-1-3Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UA-1-3LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UA-1-3WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UA-1-4Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UA-1-4LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UA-1-4WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UA-1-5Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UA-1-5LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UA-1-5WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UA-6-1Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UA-6-1LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UA-6-1WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UA-6-2Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UA-6-2LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UA-6-2WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UA-6-3Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UA-6-3LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UA-6-3WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UA-6-4Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UA-6-4LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UA-6-4WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UA-6-5Action: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UA-6-5LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UA-6-5WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUA-0-1Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUA-0-1LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUA-0-1WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUA-0-2Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUA-0-2LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUA-0-2WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUA-0-3Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUA-0-3LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUA-0-3WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUA-0-4Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUA-0-4LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUA-0-4WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUA-0-5Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUA-0-5LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUA-0-5WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUA-1-1Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUA-1-1LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUA-1-1WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUA-1-2Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUA-1-2LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUA-1-2WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUA-1-3Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUA-1-3LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUA-1-3WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUA-1-4Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUA-1-4LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUA-1-4WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUA-1-5Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUA-1-5LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUA-1-5WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUA-6-1Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUA-6-1LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUA-6-1WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUA-6-2Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUA-6-2LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUA-6-2WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUA-6-3Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUA-6-3LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUA-6-3WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUA-6-4Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUA-6-4LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUA-6-4WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUA-6-5Action: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUA-6-5LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUA-6-5WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 20A | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UR-0-1Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UR-0-1LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UR-0-1WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UR-0-2Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UR-0-2LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UR-0-2WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UR-0-3Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UR-0-3LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UR-0-3WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UR-0-4Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UR-0-4LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UR-0-4WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UR-0-5Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UR-0-5LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UR-0-5WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UR-1-1Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UR-1-1LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UR-1-1WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UR-1-2Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UR-1-2LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UR-1-2WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UR-1-3Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UR-1-3LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UR-1-3WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UR-1-4Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UR-1-4LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UR-1-4WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UR-1-5Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UR-1-5LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UR-1-5WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UR-6-1Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UR-6-1LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UR-6-1WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UR-6-2Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UR-6-2LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UR-6-2WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UR-6-3Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UR-6-3LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UR-6-3WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UR-6-4Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UR-6-4LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UR-6-4WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UR-6-5Action: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UR-6-5LAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UR-6-5WAction: Double acting | Connection: OD 12 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUR-0-1Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUR-0-1LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUR-0-1WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUR-0-2Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUR-0-2LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUR-0-2WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUR-0-3Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUR-0-3LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUR-0-3WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUR-0-4Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUR-0-4LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUR-0-4WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUR-0-5Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUR-0-5LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUR-0-5WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUR-1-1Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUR-1-1LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUR-1-1WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUR-1-2Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUR-1-2LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUR-1-2WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUR-1-3Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUR-1-3LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUR-1-3WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUR-1-4Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUR-1-4LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUR-1-4WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUR-1-5Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUR-1-5LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUR-1-5WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUR-6-1Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUR-6-1LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUR-6-1WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUR-6-2Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUR-6-2LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUR-6-2WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUR-6-3Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUR-6-3LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUR-6-3WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUR-6-4Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUR-6-4LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUR-6-4WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUR-6-5Action: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUR-6-5LAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUR-6-5WAction: Double acting | Connection: OD 1/2" tube, F-LOCK 60 | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-12UK-0-1Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-12UK-0-1LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-12UK-0-1WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-12UK-0-2Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-12UK-0-2LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-12UK-0-2WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-12UK-0-3Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-12UK-0-3LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-12UK-0-3WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-12UK-0-4Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-12UK-0-4LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-12UK-0-4WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-12UK-0-5Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-12UK-0-5LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-12UK-0-5WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-12UK-1-1Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-12UK-1-1LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-12UK-1-1WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-12UK-1-2Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-12UK-1-2LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-12UK-1-2WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-12UK-1-3Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-12UK-1-3LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-12UK-1-3WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-12UK-1-4Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-12UK-1-4LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-12UK-1-4WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-12UK-1-5Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-12UK-1-5LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-12UK-1-5WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-12UK-6-1Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-12UK-6-1LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-12UK-6-1WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-12UK-6-2Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-12UK-6-2LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-12UK-6-2WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-12UK-6-3Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-12UK-6-3LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-12UK-6-3WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-12UK-6-4Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-12UK-6-4LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-12UK-6-4WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-12UK-6-5Action: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-12UK-6-5LAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-12UK-6-5WAction: Double acting | Connection: OD 12 mm tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUK-0-1Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUK-0-1LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUK-0-1WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUK-0-2Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUK-0-2LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUK-0-2WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUK-0-3Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUK-0-3LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUK-0-3WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUK-0-4Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUK-0-4LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUK-0-4WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUK-0-5Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUK-0-5LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUK-0-5WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUK-1-1Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUK-1-1LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUK-1-1WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUK-1-2Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUK-1-2LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUK-1-2WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUK-1-3Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUK-1-3LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUK-1-3WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUK-1-4Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUK-1-4LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUK-1-4WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUK-1-5Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUK-1-5LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUK-1-5WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUK-6-1Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUK-6-1LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUK-6-1WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUK-6-2Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUK-6-2LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUK-6-2WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUK-6-3Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUK-6-3LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUK-6-3WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUK-6-4Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUK-6-4LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUK-6-4WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUK-6-5Action: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUK-6-5LAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUK-6-5WAction: Double acting | Connection: OD 1/2" tube, Final Lock | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides
GAMD332-15BUW-0-1Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Right
GAMD332-15BUW-0-1LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Left
GAMD332-15BUW-0-1WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 1 | A port: Both sides
GAMD332-15BUW-0-2Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Right
GAMD332-15BUW-0-2LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Left
GAMD332-15BUW-0-2WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 2 | A port: Both sides
GAMD332-15BUW-0-3Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Right
GAMD332-15BUW-0-3LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Left
GAMD332-15BUW-0-3WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 3 | A port: Both sides
GAMD332-15BUW-0-4Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Right
GAMD332-15BUW-0-4LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Left
GAMD332-15BUW-0-4WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 4 | A port: Both sides
GAMD332-15BUW-0-5Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Right
GAMD332-15BUW-0-5LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Left
GAMD332-15BUW-0-5WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF only | Stations: 5 | A port: Both sides
GAMD332-15BUW-1-1Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Right
GAMD332-15BUW-1-1LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Left
GAMD332-15BUW-1-1WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 1 | A port: Both sides
GAMD332-15BUW-1-2Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Right
GAMD332-15BUW-1-2LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Left
GAMD332-15BUW-1-2WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 2 | A port: Both sides
GAMD332-15BUW-1-3Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Right
GAMD332-15BUW-1-3LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Left
GAMD332-15BUW-1-3WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 3 | A port: Both sides
GAMD332-15BUW-1-4Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Right
GAMD332-15BUW-1-4LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Left
GAMD332-15BUW-1-4WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 4 | A port: Both sides
GAMD332-15BUW-1-5Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Right
GAMD332-15BUW-1-5LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Left
GAMD332-15BUW-1-5WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: Flow adjustment | Stations: 5 | A port: Both sides
GAMD332-15BUW-6-1Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Right
GAMD332-15BUW-6-1LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Left
GAMD332-15BUW-6-1WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 1 | A port: Both sides
GAMD332-15BUW-6-2Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Right
GAMD332-15BUW-6-2LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Left
GAMD332-15BUW-6-2WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 2 | A port: Both sides
GAMD332-15BUW-6-3Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Right
GAMD332-15BUW-6-3LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Left
GAMD332-15BUW-6-3WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 3 | A port: Both sides
GAMD332-15BUW-6-4Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Right
GAMD332-15BUW-6-4LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Left
GAMD332-15BUW-6-4WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 4 | A port: Both sides
GAMD332-15BUW-6-5Action: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Right
GAMD332-15BUW-6-5LAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Left
GAMD332-15BUW-6-5WAction: Double acting | Connection: OD 1/2" tube, Flare Tek | Option: ON-OFF, indicator | Stations: 5 | A port: Both sides

Need a different model, or a part not listed here? Send us your parts list →