Skip to product information
1 of 1

CKD MN4GD2 Block Manifold Valve Blocks (Individual Wiring, Direct)

CKD MN4GD2 Block Manifold Valve Blocks (Individual Wiring, Direct)

CKD MN3GD2/MN4GD2 individual-wiring block manifold (direct piping) valve blocks with mounted valve (N-prefixed) and the matching solenoid valves, as full order codes.

Key features

  • Split resin block construction: stations can be added or removed freely; up to 24 stations (20 for size 2)
  • Valve block codes N4GD2... include valve, block and A/B port; solenoid valve only codes end in 9R
  • Wiring: grommet (DC only), E connector with or without lamp/surge killer, socket-less E connector, DIN terminal box (size 2)
  • Options H (exhaust malfunction prevention), A (ozone/coolant resistant), F (A/B filter) and lead-wire lengths E00-E03/E20-E23, EJ connectors, E1/E3 are orderable but not listed
  • Manifold assembly codes MN4GD280R-[port]-[wiring]-[stations]-[voltage] are built from these blocks via the manifold specification sheet

Specifications

Manifold Block manifold, individual wiring
Piping Direct Piping
Operation Pilot operated soft spool
Operating pressure 0.2 to 0.7 MPa
Fluid Compressed air
Ambient temp. -5 to 55 C
Source CKD Korea catalog CB-023SK-9, p. 686-697, 738-739
N3GD210R-C4-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-C4-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-C4-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-C4-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-C4-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-C4-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-C4-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-C4-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-C4-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-C4-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-C4-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-C4-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-C4-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-C4-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-C4-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-C4-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-C4-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-C4-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-C4-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-C4-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-C4-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-C4-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD210R-C6-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-C6-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-C6-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-C6-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-C6-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-C6-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-C6-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-C6-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-C6-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-C6-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-C6-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-C6-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-C6-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-C6-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-C6-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-C6-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-C6-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-C6-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-C6-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-C6-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-C6-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-C6-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD210R-C8-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-C8-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-C8-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-C8-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-C8-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-C8-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-C8-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-C8-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-C8-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-C8-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-C8-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-C8-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-C8-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-C8-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-C8-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-C8-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-C8-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-C8-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-C8-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-C8-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-C8-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-C8-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD210R-06-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-06-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-06-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-06-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-06-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-06-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-06-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-06-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-06-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-06-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-06-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-06-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-06-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-06-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-06-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-06-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-06-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-06-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-06-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-06-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-06-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-06-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-C4-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-C4-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-C4-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-C4-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-C4-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-C4-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-C4-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-C4-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-C4-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-C4-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-C4-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-C4-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-C4-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-C4-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-C4-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-C4-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-C4-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-C4-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-C4-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-C4-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-C4-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-C4-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-C6-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-C6-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-C6-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-C6-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-C6-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-C6-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-C6-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-C6-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-C6-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-C6-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-C6-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-C6-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-C6-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-C6-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-C6-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-C6-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-C6-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-C6-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-C6-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-C6-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-C6-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-C6-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-C8-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-C8-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-C8-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-C8-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-C8-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-C8-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-C8-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-C8-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-C8-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-C8-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-C8-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-C8-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-C8-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-C8-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-C8-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-C8-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-C8-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-C8-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-C8-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-C8-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-C8-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-C8-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-06-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-06-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-06-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-06-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-06-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-06-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-06-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-06-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-06-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-06-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-06-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-06-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-06-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-06-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-06-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-06-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-06-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-06-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-06-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-06-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-06-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-06-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-C4-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-C4-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-C4-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-C4-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-C4-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-C4-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-C4-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-C4-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-C4-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-C4-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-C4-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-C4-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-C4-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-C4-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-C4-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-C4-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-C4-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-C4-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-C4-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-C4-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-C4-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-C4-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-C6-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-C6-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-C6-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-C6-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-C6-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-C6-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-C6-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-C6-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-C6-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-C6-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-C6-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-C6-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-C6-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-C6-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-C6-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-C6-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-C6-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-C6-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-C6-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-C6-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-C6-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-C6-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-C8-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-C8-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-C8-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-C8-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-C8-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-C8-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-C8-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-C8-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-C8-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-C8-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-C8-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-C8-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-C8-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-C8-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-C8-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-C8-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-C8-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-C8-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-C8-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-C8-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-C8-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-C8-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-06-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-06-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-06-E0-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-06-E0-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-06-E0-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-06-E0N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-06-E0N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-06-E0N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-06-E2-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-06-E2-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-06-E2-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-06-E2N-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-06-E2N-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-06-E2N-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-06-B-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-06-B-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-06-B-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-06-B-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-06-BN-1 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-06-BN-2 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-06-BN-3 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-06-BN-4 Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-C4-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-C4-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-C4-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-C4-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-C4-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-C4-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-C4-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-C4-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-C4-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-C4-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-C4-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-C4-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-C4-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-C4-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-C4-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-C4-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-C4-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-C4-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-C4-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-C4-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-C4-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-C4-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-C6-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-C6-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-C6-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-C6-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-C6-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-C6-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-C6-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-C6-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-C6-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-C6-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-C6-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-C6-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-C6-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-C6-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-C6-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-C6-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-C6-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-C6-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-C6-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-C6-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-C6-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-C6-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-C8-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-C8-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-C8-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-C8-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-C8-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-C8-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-C8-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-C8-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-C8-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-C8-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-C8-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-C8-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-C8-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-C8-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-C8-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-C8-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-C8-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-C8-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-C8-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-C8-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-C8-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-C8-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-06-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-06-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-06-E0-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-06-E0-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-06-E0-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-06-E0N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-06-E0N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-06-E0N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-06-E2-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-06-E2-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-06-E2-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-06-E2N-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-06-E2N-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-06-E2N-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-06-B-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-06-B-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-06-B-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-06-B-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-06-BN-1 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-06-BN-2 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-06-BN-3 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-06-BN-4 Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-C4-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-C4-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-C4-E0-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-C4-E0-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-C4-E0-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-C4-E0N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-C4-E0N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-C4-E0N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-C4-E2-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-C4-E2-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-C4-E2-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-C4-E2N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-C4-E2N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-C4-E2N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-C4-B-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-C4-B-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-C4-B-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-C4-BN-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-C4-BN-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-C4-BN-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-C6-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-C6-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-C6-E0-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-C6-E0-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-C6-E0-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-C6-E0N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-C6-E0N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-C6-E0N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-C6-E2-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-C6-E2-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-C6-E2-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-C6-E2N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-C6-E2N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-C6-E2N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-C6-B-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-C6-B-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-C6-B-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-C6-BN-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-C6-BN-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-C6-BN-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-C8-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-C8-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-C8-E0-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-C8-E0-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-C8-E0-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-C8-E0N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-C8-E0N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-C8-E0N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-C8-E2-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-C8-E2-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-C8-E2-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-C8-E2N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-C8-E2N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-C8-E2N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-C8-B-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-C8-B-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-C8-B-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-C8-BN-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-C8-BN-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-C8-BN-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-06-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-06-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-06-E0-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-06-E0-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-06-E0-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-06-E0N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-06-E0N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-06-E0N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-06-E2-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-06-E2-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-06-E2-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-06-E2N-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-06-E2N-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-06-E2N-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-06-B-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-06-B-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-06-B-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-06-BN-1 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-06-BN-3 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-06-BN-4 Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-C4-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-C4-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-C4-E0-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-C4-E0-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-C4-E0-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-C4-E0N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-C4-E0N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-C4-E0N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-C4-E2-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-C4-E2-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-C4-E2-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-C4-E2N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-C4-E2N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-C4-E2N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-C4-B-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-C4-B-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-C4-B-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-C4-BN-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-C4-BN-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-C4-BN-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-C6-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-C6-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-C6-E0-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-C6-E0-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-C6-E0-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-C6-E0N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-C6-E0N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-C6-E0N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-C6-E2-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-C6-E2-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-C6-E2-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-C6-E2N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-C6-E2N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-C6-E2N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-C6-B-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-C6-B-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-C6-B-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-C6-BN-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-C6-BN-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-C6-BN-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-C8-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-C8-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-C8-E0-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-C8-E0-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-C8-E0-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-C8-E0N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-C8-E0N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-C8-E0N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-C8-E2-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-C8-E2-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-C8-E2-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-C8-E2N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-C8-E2N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-C8-E2N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-C8-B-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-C8-B-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-C8-B-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-C8-BN-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-C8-BN-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-C8-BN-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-06-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-06-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-06-E0-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-06-E0-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-06-E0-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-06-E0N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-06-E0N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-06-E0N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-06-E2-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-06-E2-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-06-E2-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-06-E2N-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-06-E2N-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-06-E2N-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-06-B-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-06-B-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-06-B-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-06-BN-1 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-06-BN-3 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-06-BN-4 Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-C4-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-C4-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-C4-E0-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-C4-E0-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-C4-E0-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-C4-E0N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-C4-E0N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-C4-E0N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-C4-E2-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-C4-E2-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-C4-E2-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-C4-E2N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-C4-E2N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-C4-E2N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-C4-B-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-C4-B-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-C4-B-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-C4-B-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-C4-BN-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-C4-BN-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-C4-BN-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-C4-BN-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-C6-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-C6-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-C6-E0-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-C6-E0-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-C6-E0-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-C6-E0N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-C6-E0N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-C6-E0N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-C6-E2-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-C6-E2-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-C6-E2-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-C6-E2N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-C6-E2N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-C6-E2N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-C6-B-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-C6-B-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-C6-B-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-C6-B-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-C6-BN-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-C6-BN-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-C6-BN-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-C6-BN-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-C8-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-C8-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-C8-E0-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-C8-E0-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-C8-E0-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-C8-E0N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-C8-E0N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-C8-E0N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-C8-E2-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-C8-E2-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-C8-E2-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-C8-E2N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-C8-E2N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-C8-E2N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-C8-B-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-C8-B-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-C8-B-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-C8-B-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-C8-BN-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-C8-BN-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-C8-BN-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-C8-BN-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-06-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-06-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-06-E0-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-06-E0-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-06-E0-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-06-E0N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-06-E0N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-06-E0N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-06-E2-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-06-E2-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-06-E2-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-06-E2N-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-06-E2N-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-06-E2N-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-06-B-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-06-B-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-06-B-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-06-B-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-06-BN-1 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-06-BN-2 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-06-BN-3 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-06-BN-4 Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-C4-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-C4-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-C4-E0-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-C4-E0-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-C4-E0-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-C4-E0N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-C4-E0N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-C4-E0N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-C4-E2-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-C4-E2-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-C4-E2-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-C4-E2N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-C4-E2N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-C4-E2N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-C4-B-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-C4-B-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-C4-B-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-C4-B-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-C4-BN-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-C4-BN-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-C4-BN-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-C4-BN-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-C6-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-C6-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-C6-E0-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-C6-E0-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-C6-E0-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-C6-E0N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-C6-E0N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-C6-E0N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-C6-E2-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-C6-E2-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-C6-E2-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-C6-E2N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-C6-E2N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-C6-E2N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-C6-B-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-C6-B-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-C6-B-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-C6-B-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-C6-BN-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-C6-BN-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-C6-BN-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-C6-BN-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-C8-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-C8-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-C8-E0-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-C8-E0-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-C8-E0-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-C8-E0N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-C8-E0N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-C8-E0N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-C8-E2-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-C8-E2-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-C8-E2-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-C8-E2N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-C8-E2N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-C8-E2N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-C8-B-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-C8-B-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-C8-B-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-C8-B-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-C8-BN-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-C8-BN-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-C8-BN-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-C8-BN-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-06-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-06-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-06-E0-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-06-E0-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-06-E0-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-06-E0N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-06-E0N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-06-E0N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-06-E2-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-06-E2-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-06-E2-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-06-E2N-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-06-E2N-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-06-E2N-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-06-B-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-06-B-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-06-B-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-06-B-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-06-BN-1 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-06-BN-2 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-06-BN-3 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-06-BN-4 Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-C4-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-C4-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-C4-E0-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-C4-E0-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-C4-E0-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-C4-E0N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-C4-E0N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-C4-E0N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-C4-E2-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-C4-E2-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-C4-E2-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-C4-E2N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-C4-E2N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-C4-E2N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-C4-B-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-C4-B-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-C4-B-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-C4-B-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-C4-BN-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-C4-BN-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-C4-BN-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-C4-BN-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-C6-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-C6-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-C6-E0-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-C6-E0-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-C6-E0-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-C6-E0N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-C6-E0N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-C6-E0N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-C6-E2-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-C6-E2-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-C6-E2-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-C6-E2N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-C6-E2N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-C6-E2N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-C6-B-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-C6-B-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-C6-B-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-C6-B-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-C6-BN-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-C6-BN-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-C6-BN-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-C6-BN-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-C8-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-C8-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-C8-E0-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-C8-E0-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-C8-E0-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-C8-E0N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-C8-E0N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-C8-E0N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-C8-E2-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-C8-E2-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-C8-E2-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-C8-E2N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-C8-E2N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-C8-E2N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-C8-B-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-C8-B-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-C8-B-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-C8-B-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-C8-BN-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-C8-BN-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-C8-BN-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-C8-BN-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-06-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-06-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-06-E0-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-06-E0-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-06-E0-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-06-E0N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-06-E0N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-06-E0N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-06-E2-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-06-E2-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-06-E2-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-06-E2N-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-06-E2N-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-06-E2N-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-06-B-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-06-B-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-06-B-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-06-B-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-06-BN-1 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-06-BN-2 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-06-BN-3 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-06-BN-4 Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-C4-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-C4-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-C4-E0-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-C4-E0-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-C4-E0-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-C4-E0N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-C4-E0N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-C4-E0N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-C4-E2-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-C4-E2-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-C4-E2-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-C4-E2N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-C4-E2N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-C4-E2N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-C4-B-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-C4-B-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-C4-B-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-C4-B-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-C4-BN-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-C4-BN-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-C4-BN-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-C4-BN-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-C6-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-C6-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-C6-E0-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-C6-E0-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-C6-E0-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-C6-E0N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-C6-E0N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-C6-E0N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-C6-E2-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-C6-E2-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-C6-E2-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-C6-E2N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-C6-E2N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-C6-E2N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-C6-B-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-C6-B-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-C6-B-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-C6-B-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-C6-BN-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-C6-BN-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-C6-BN-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-C6-BN-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-C8-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-C8-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-C8-E0-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-C8-E0-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-C8-E0-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-C8-E0N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-C8-E0N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-C8-E0N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-C8-E2-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-C8-E2-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-C8-E2-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-C8-E2N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-C8-E2N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-C8-E2N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-C8-B-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-C8-B-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-C8-B-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-C8-B-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-C8-BN-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-C8-BN-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-C8-BN-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-C8-BN-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-06-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-06-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-06-E0-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-06-E0-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-06-E0-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-06-E0N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-06-E0N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-06-E0N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-06-E2-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-06-E2-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-06-E2-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-06-E2N-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-06-E2N-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-06-E2N-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-06-B-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-06-B-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-06-B-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-06-B-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-06-BN-1 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-06-BN-2 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-06-BN-3 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-06-BN-4 Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-C4-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-C4-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-C4-E0-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-C4-E0-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-C4-E0-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-C4-E0N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-C4-E0N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-C4-E0N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-C4-E2-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-C4-E2-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-C4-E2-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-C4-E2N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-C4-E2N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-C4-E2N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-C4-B-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-C4-B-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-C4-B-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-C4-B-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-C4-BN-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-C4-BN-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-C4-BN-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-C4-BN-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-C6-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-C6-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-C6-E0-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-C6-E0-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-C6-E0-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-C6-E0N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-C6-E0N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-C6-E0N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-C6-E2-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-C6-E2-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-C6-E2-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-C6-E2N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-C6-E2N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-C6-E2N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-C6-B-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-C6-B-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-C6-B-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-C6-B-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-C6-BN-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-C6-BN-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-C6-BN-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-C6-BN-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-C8-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-C8-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-C8-E0-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-C8-E0-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-C8-E0-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-C8-E0N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-C8-E0N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-C8-E0N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-C8-E2-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-C8-E2-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-C8-E2-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-C8-E2N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-C8-E2N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-C8-E2N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-C8-B-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-C8-B-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-C8-B-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-C8-B-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-C8-BN-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-C8-BN-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-C8-BN-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-C8-BN-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-06-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-06-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-06-E0-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-06-E0-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-06-E0-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-06-E0N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-06-E0N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-06-E0N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-06-E2-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-06-E2-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-06-E2-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-06-E2N-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-06-E2N-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-06-E2N-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-06-B-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-06-B-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-06-B-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-06-B-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-06-BN-1 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-06-BN-2 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-06-BN-3 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-06-BN-4 Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-C4-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-C4-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-C4-E0-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-C4-E0-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-C4-E0-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-C4-E0N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-C4-E0N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-C4-E0N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-C4-E2-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-C4-E2-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-C4-E2-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-C4-E2N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-C4-E2N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-C4-E2N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-C4-B-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-C4-B-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-C4-B-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-C4-B-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-C4-BN-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-C4-BN-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-C4-BN-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-C4-BN-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-C6-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-C6-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-C6-E0-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-C6-E0-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-C6-E0-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-C6-E0N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-C6-E0N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-C6-E0N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-C6-E2-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-C6-E2-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-C6-E2-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-C6-E2N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-C6-E2N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-C6-E2N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-C6-B-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-C6-B-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-C6-B-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-C6-B-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-C6-BN-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-C6-BN-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-C6-BN-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-C6-BN-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-C8-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-C8-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-C8-E0-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-C8-E0-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-C8-E0-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-C8-E0N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-C8-E0N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-C8-E0N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-C8-E2-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-C8-E2-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-C8-E2-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-C8-E2N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-C8-E2N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-C8-E2N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-C8-B-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-C8-B-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-C8-B-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-C8-B-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-C8-BN-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-C8-BN-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-C8-BN-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-C8-BN-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-06-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-06-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-06-E0-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-06-E0-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-06-E0-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-06-E0N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-06-E0N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-06-E0N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-06-E2-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-06-E2-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-06-E2-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-06-E2N-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-06-E2N-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-06-E2N-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-06-B-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-06-B-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-06-B-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-06-B-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-06-BN-1 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-06-BN-2 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-06-BN-3 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-06-BN-4 Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-C4-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-C4-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-C4-E0-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-C4-E0-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-C4-E0-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-C4-E0N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-C4-E0N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-C4-E0N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-C4-E2-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-C4-E2-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-C4-E2-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-C4-E2N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-C4-E2N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-C4-E2N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-C4-B-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-C4-B-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-C4-B-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-C4-B-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-C4-BN-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-C4-BN-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-C4-BN-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-C4-BN-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-C6-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-C6-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-C6-E0-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-C6-E0-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-C6-E0-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-C6-E0N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-C6-E0N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-C6-E0N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-C6-E2-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-C6-E2-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-C6-E2-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-C6-E2N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-C6-E2N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-C6-E2N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-C6-B-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-C6-B-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-C6-B-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-C6-B-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-C6-BN-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-C6-BN-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-C6-BN-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-C6-BN-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-C8-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-C8-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-C8-E0-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-C8-E0-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-C8-E0-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-C8-E0N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-C8-E0N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-C8-E0N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-C8-E2-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-C8-E2-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-C8-E2-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-C8-E2N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-C8-E2N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-C8-E2N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-C8-B-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-C8-B-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-C8-B-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-C8-B-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-C8-BN-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-C8-BN-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-C8-BN-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-C8-BN-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-06-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-06-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-06-E0-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-06-E0-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-06-E0-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-06-E0N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-06-E0N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-06-E0N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-06-E2-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-06-E2-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-06-E2-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-06-E2N-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-06-E2N-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-06-E2N-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-06-B-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-06-B-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-06-B-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-06-B-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-06-BN-1 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-06-BN-2 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-06-BN-3 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-06-BN-4 Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-C4-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-C4-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-C4-E0-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-C4-E0-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-C4-E0-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-C4-E0N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-C4-E0N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-C4-E0N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-C4-E2-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-C4-E2-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-C4-E2-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-C4-E2N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-C4-E2N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-C4-E2N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-C4-B-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-C4-B-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-C4-B-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-C4-B-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-C4-BN-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-C4-BN-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-C4-BN-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-C4-BN-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-C6-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-C6-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-C6-E0-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-C6-E0-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-C6-E0-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-C6-E0N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-C6-E0N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-C6-E0N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-C6-E2-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-C6-E2-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-C6-E2-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-C6-E2N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-C6-E2N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-C6-E2N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-C6-B-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-C6-B-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-C6-B-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-C6-B-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-C6-BN-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-C6-BN-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-C6-BN-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-C6-BN-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-C8-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-C8-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-C8-E0-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-C8-E0-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-C8-E0-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-C8-E0N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-C8-E0N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-C8-E0N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-C8-E2-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-C8-E2-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-C8-E2-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-C8-E2N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-C8-E2N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-C8-E2N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-C8-B-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-C8-B-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-C8-B-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-C8-B-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-C8-BN-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-C8-BN-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-C8-BN-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-C8-BN-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-06-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-06-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-06-E0-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-06-E0-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-06-E0-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-06-E0N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-06-E0N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-06-E0N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-06-E2-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-06-E2-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-06-E2-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-06-E2N-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-06-E2N-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-06-E2N-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-06-B-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-06-B-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-06-B-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-06-B-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-06-BN-1 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-06-BN-2 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-06-BN-3 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-06-BN-4 Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-C4-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-C4-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-C4-E0-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-C4-E0-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-C4-E0-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-C4-E0N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-C4-E0N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-C4-E0N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-C4-E2-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-C4-E2-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-C4-E2-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-C4-E2N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-C4-E2N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-C4-E2N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-C4-B-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-C4-B-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-C4-B-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-C4-B-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-C4-BN-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-C4-BN-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-C4-BN-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-C4-BN-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-C6-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-C6-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-C6-E0-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-C6-E0-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-C6-E0-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-C6-E0N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-C6-E0N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-C6-E0N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-C6-E2-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-C6-E2-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-C6-E2-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-C6-E2N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-C6-E2N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-C6-E2N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-C6-B-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-C6-B-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-C6-B-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-C6-B-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-C6-BN-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-C6-BN-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-C6-BN-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-C6-BN-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-C8-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-C8-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-C8-E0-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-C8-E0-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-C8-E0-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-C8-E0N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-C8-E0N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-C8-E0N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-C8-E2-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-C8-E2-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-C8-E2-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-C8-E2N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-C8-E2N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-C8-E2N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-C8-B-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-C8-B-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-C8-B-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-C8-B-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-C8-BN-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-C8-BN-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-C8-BN-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-C8-BN-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-06-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-06-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-06-E0-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-06-E0-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-06-E0-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-06-E0N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-06-E0N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-06-E0N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-06-E2-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-06-E2-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-06-E2-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-06-E2N-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-06-E2N-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-06-E2N-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-06-B-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-06-B-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-06-B-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-06-B-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-06-BN-1 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-06-BN-2 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-06-BN-3 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-06-BN-4 Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-C4-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-C4-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-C4-E0-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-C4-E0-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-C4-E0-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-C4-E0N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-C4-E0N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-C4-E0N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-C4-E2-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-C4-E2-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-C4-E2-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-C4-E2N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-C4-E2N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-C4-E2N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-C4-B-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-C4-B-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-C4-B-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-C4-B-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-C4-BN-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-C4-BN-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-C4-BN-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-C4-BN-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-C6-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-C6-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-C6-E0-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-C6-E0-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-C6-E0-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-C6-E0N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-C6-E0N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-C6-E0N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-C6-E2-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-C6-E2-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-C6-E2-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-C6-E2N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-C6-E2N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-C6-E2N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-C6-B-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-C6-B-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-C6-B-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-C6-B-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-C6-BN-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-C6-BN-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-C6-BN-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-C6-BN-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-C8-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-C8-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-C8-E0-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-C8-E0-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-C8-E0-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-C8-E0N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-C8-E0N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-C8-E0N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-C8-E2-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-C8-E2-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-C8-E2-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-C8-E2N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-C8-E2N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-C8-E2N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-C8-B-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-C8-B-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-C8-B-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-C8-B-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-C8-BN-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-C8-BN-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-C8-BN-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-C8-BN-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-06-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-06-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-06-E0-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-06-E0-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-06-E0-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-06-E0N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-06-E0N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-06-E0N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-06-E2-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-06-E2-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-06-E2-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-06-E2N-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-06-E2N-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-06-E2N-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-06-B-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-06-B-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-06-B-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-06-B-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-06-BN-1 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-06-BN-2 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-06-BN-3 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-06-BN-4 Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
Solenoid ValvesCKD
1392 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

CKD MN4GD2 Block Manifold Valve Blocks (Individual Wiring, Direct)

Brand CKD·Solenoid Valves

Available part numbers (1392)

N3GD210R-C4-3, N3GD210R-C4-4, N3GD210R-C4-E0-1, N3GD210R-C4-E0-3, N3GD210R-C4-E0-4, N3GD210R-C4-E0N-1, N3GD210R-C4-E0N-3, N3GD210R-C4-E0N-4, N3GD210R-C4-E2-1, N3GD210R-C4-E2-3 + 1382 more — see full table ↓

How to order

Send the CKD part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
N3GD210R-C4-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-C4-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-C4-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-C4-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-C4-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-C4-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-C4-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-C4-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-C4-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-C4-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-C4-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-C4-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-C4-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-C4-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-C4-B-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-C4-B-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-C4-B-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-C4-B-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-C4-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-C4-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-C4-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-C4-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD210R-C6-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-C6-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-C6-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-C6-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-C6-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-C6-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-C6-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-C6-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-C6-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-C6-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-C6-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-C6-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-C6-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-C6-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-C6-B-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-C6-B-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-C6-B-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-C6-B-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-C6-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-C6-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-C6-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-C6-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD210R-C8-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-C8-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-C8-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-C8-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-C8-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-C8-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-C8-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-C8-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-C8-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-C8-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-C8-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-C8-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-C8-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-C8-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-C8-B-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-C8-B-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-C8-B-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-C8-B-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-C8-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-C8-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-C8-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-C8-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD210R-06-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD210R-06-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD210R-06-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD210R-06-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD210R-06-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD210R-06-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N3GD210R-06-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N3GD210R-06-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N3GD210R-06-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD210R-06-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD210R-06-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD210R-06-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD210R-06-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD210R-06-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD210R-06-B-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N3GD210R-06-B-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N3GD210R-06-B-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N3GD210R-06-B-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N3GD210R-06-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD210R-06-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD210R-06-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD210R-06-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-C4-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-C4-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-C4-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-C4-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-C4-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-C4-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-C4-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-C4-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-C4-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-C4-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-C4-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-C4-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-C4-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-C4-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-C4-B-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-C4-B-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-C4-B-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-C4-B-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-C4-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-C4-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-C4-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-C4-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-C6-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-C6-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-C6-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-C6-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-C6-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-C6-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-C6-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-C6-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-C6-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-C6-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-C6-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-C6-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-C6-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-C6-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-C6-B-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-C6-B-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-C6-B-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-C6-B-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-C6-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-C6-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-C6-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-C6-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-C8-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-C8-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-C8-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-C8-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-C8-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-C8-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-C8-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-C8-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-C8-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-C8-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-C8-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-C8-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-C8-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-C8-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-C8-B-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-C8-B-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-C8-B-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-C8-B-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-C8-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-C8-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-C8-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-C8-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD219R-06-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD219R-06-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD219R-06-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD219R-06-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD219R-06-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD219R-06-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
3GD219R-06-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
3GD219R-06-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
3GD219R-06-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD219R-06-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD219R-06-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD219R-06-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD219R-06-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD219R-06-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD219R-06-B-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
3GD219R-06-B-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
3GD219R-06-B-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
3GD219R-06-B-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
3GD219R-06-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
3GD219R-06-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
3GD219R-06-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
3GD219R-06-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-C4-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-C4-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-C4-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-C4-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-C4-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-C4-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-C4-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-C4-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-C4-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-C4-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-C4-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-C4-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-C4-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-C4-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-C4-B-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-C4-B-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-C4-B-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-C4-B-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-C4-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-C4-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-C4-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-C4-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-C6-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-C6-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-C6-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-C6-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-C6-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-C6-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-C6-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-C6-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-C6-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-C6-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-C6-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-C6-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-C6-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-C6-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-C6-B-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-C6-B-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-C6-B-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-C6-B-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-C6-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-C6-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-C6-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-C6-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-C8-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-C8-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-C8-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-C8-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-C8-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-C8-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-C8-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-C8-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-C8-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-C8-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-C8-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-C8-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-C8-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-C8-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-C8-B-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-C8-B-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-C8-B-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-C8-B-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-C8-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-C8-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-C8-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-C8-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2110R-06-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2110R-06-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2110R-06-E0-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2110R-06-E0-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2110R-06-E0-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2110R-06-E0N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N3GD2110R-06-E0N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N3GD2110R-06-E0N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N3GD2110R-06-E2-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2110R-06-E2-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2110R-06-E2-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2110R-06-E2N-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2110R-06-E2N-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2110R-06-E2N-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2110R-06-B-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N3GD2110R-06-B-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N3GD2110R-06-B-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N3GD2110R-06-B-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N3GD2110R-06-BN-1Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2110R-06-BN-2Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N3GD2110R-06-BN-3Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2110R-06-BN-4Model: N3GD2 valve block | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-C4-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-C4-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-C4-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-C4-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-C4-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-C4-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-C4-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-C4-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-C4-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-C4-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-C4-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-C4-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-C4-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-C4-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-C4-B-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-C4-B-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-C4-B-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-C4-B-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-C4-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-C4-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-C4-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-C4-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-C6-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-C6-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-C6-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-C6-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-C6-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-C6-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-C6-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-C6-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-C6-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-C6-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-C6-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-C6-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-C6-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-C6-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-C6-B-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-C6-B-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-C6-B-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-C6-B-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-C6-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-C6-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-C6-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-C6-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-C8-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-C8-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-C8-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-C8-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-C8-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-C8-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-C8-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-C8-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-C8-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-C8-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-C8-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-C8-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-C8-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-C8-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-C8-B-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-C8-B-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-C8-B-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-C8-B-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-C8-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-C8-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-C8-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-C8-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2119R-06-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2119R-06-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2119R-06-E0-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2119R-06-E0-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2119R-06-E0-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2119R-06-E0N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
3GD2119R-06-E0N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
3GD2119R-06-E0N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
3GD2119R-06-E2-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2119R-06-E2-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2119R-06-E2-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2119R-06-E2N-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2119R-06-E2N-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2119R-06-E2N-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2119R-06-B-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
3GD2119R-06-B-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
3GD2119R-06-B-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
3GD2119R-06-B-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
3GD2119R-06-BN-1Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2119R-06-BN-2Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
3GD2119R-06-BN-3Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2119R-06-BN-4Model: 3GD2 valve only | Switching: 2-pos single N.O. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-C4-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-C4-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-C4-E0-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-C4-E0-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-C4-E0-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-C4-E0N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-C4-E0N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-C4-E0N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-C4-E2-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-C4-E2-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-C4-E2-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-C4-E2N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-C4-E2N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-C4-E2N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-C4-B-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-C4-B-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-C4-B-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-C4-BN-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-C4-BN-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-C4-BN-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-C6-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-C6-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-C6-E0-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-C6-E0-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-C6-E0-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-C6-E0N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-C6-E0N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-C6-E0N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-C6-E2-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-C6-E2-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-C6-E2-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-C6-E2N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-C6-E2N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-C6-E2N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-C6-B-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-C6-B-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-C6-B-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-C6-BN-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-C6-BN-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-C6-BN-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-C8-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-C8-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-C8-E0-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-C8-E0-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-C8-E0-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-C8-E0N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-C8-E0N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-C8-E0N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-C8-E2-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-C8-E2-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-C8-E2-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-C8-E2N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-C8-E2N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-C8-E2N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-C8-B-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-C8-B-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-C8-B-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-C8-BN-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-C8-BN-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-C8-BN-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N3GD2660R-06-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N3GD2660R-06-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N3GD2660R-06-E0-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N3GD2660R-06-E0-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N3GD2660R-06-E0-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N3GD2660R-06-E0N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N3GD2660R-06-E0N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N3GD2660R-06-E0N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N3GD2660R-06-E2-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N3GD2660R-06-E2-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N3GD2660R-06-E2-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N3GD2660R-06-E2N-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N3GD2660R-06-E2N-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N3GD2660R-06-E2N-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N3GD2660R-06-B-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N3GD2660R-06-B-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N3GD2660R-06-B-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N3GD2660R-06-BN-1Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N3GD2660R-06-BN-3Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N3GD2660R-06-BN-4Model: N3GD2 valve block | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-C4-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-C4-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-C4-E0-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-C4-E0-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-C4-E0-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-C4-E0N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-C4-E0N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-C4-E0N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-C4-E2-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-C4-E2-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-C4-E2-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-C4-E2N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-C4-E2N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-C4-E2N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-C4-B-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-C4-B-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-C4-B-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-C4-BN-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-C4-BN-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-C4-BN-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-C6-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-C6-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-C6-E0-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-C6-E0-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-C6-E0-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-C6-E0N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-C6-E0N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-C6-E0N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-C6-E2-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-C6-E2-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-C6-E2-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-C6-E2N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-C6-E2N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-C6-E2N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-C6-B-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-C6-B-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-C6-B-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-C6-BN-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-C6-BN-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-C6-BN-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-C8-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-C8-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-C8-E0-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-C8-E0-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-C8-E0-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-C8-E0N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-C8-E0N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-C8-E0N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-C8-E2-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-C8-E2-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-C8-E2-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-C8-E2N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-C8-E2N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-C8-E2N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-C8-B-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-C8-B-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-C8-B-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-C8-BN-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-C8-BN-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-C8-BN-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
3GD2669R-06-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
3GD2669R-06-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
3GD2669R-06-E0-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
3GD2669R-06-E0-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
3GD2669R-06-E0-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
3GD2669R-06-E0N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
3GD2669R-06-E0N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
3GD2669R-06-E0N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
3GD2669R-06-E2-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
3GD2669R-06-E2-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
3GD2669R-06-E2-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
3GD2669R-06-E2N-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
3GD2669R-06-E2N-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
3GD2669R-06-E2N-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
3GD2669R-06-B-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
3GD2669R-06-B-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
3GD2669R-06-B-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
3GD2669R-06-BN-1Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
3GD2669R-06-BN-3Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
3GD2669R-06-BN-4Model: 3GD2 valve only | Switching: Dual 3-port N.C./N.C. | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-C4-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-C4-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-C4-E0-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-C4-E0-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-C4-E0-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-C4-E0N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-C4-E0N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-C4-E0N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-C4-E2-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-C4-E2-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-C4-E2-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-C4-E2N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-C4-E2N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-C4-E2N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-C4-B-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-C4-B-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-C4-B-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-C4-B-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-C4-BN-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-C4-BN-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-C4-BN-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-C4-BN-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-C6-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-C6-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-C6-E0-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-C6-E0-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-C6-E0-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-C6-E0N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-C6-E0N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-C6-E0N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-C6-E2-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-C6-E2-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-C6-E2-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-C6-E2N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-C6-E2N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-C6-E2N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-C6-B-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-C6-B-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-C6-B-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-C6-B-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-C6-BN-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-C6-BN-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-C6-BN-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-C6-BN-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-C8-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-C8-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-C8-E0-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-C8-E0-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-C8-E0-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-C8-E0N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-C8-E0N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-C8-E0N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-C8-E2-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-C8-E2-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-C8-E2-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-C8-E2N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-C8-E2N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-C8-E2N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-C8-B-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-C8-B-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-C8-B-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-C8-B-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-C8-BN-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-C8-BN-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-C8-BN-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-C8-BN-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD210R-06-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD210R-06-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD210R-06-E0-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD210R-06-E0-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD210R-06-E0-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD210R-06-E0N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD210R-06-E0N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD210R-06-E0N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD210R-06-E2-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD210R-06-E2-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD210R-06-E2-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD210R-06-E2N-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD210R-06-E2N-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD210R-06-E2N-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD210R-06-B-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD210R-06-B-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD210R-06-B-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD210R-06-B-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD210R-06-BN-1Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD210R-06-BN-2Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD210R-06-BN-3Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD210R-06-BN-4Model: N4GD2 valve block | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-C4-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-C4-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-C4-E0-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-C4-E0-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-C4-E0-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-C4-E0N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-C4-E0N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-C4-E0N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-C4-E2-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-C4-E2-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-C4-E2-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-C4-E2N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-C4-E2N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-C4-E2N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-C4-B-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-C4-B-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-C4-B-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-C4-B-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-C4-BN-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-C4-BN-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-C4-BN-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-C4-BN-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-C6-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-C6-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-C6-E0-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-C6-E0-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-C6-E0-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-C6-E0N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-C6-E0N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-C6-E0N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-C6-E2-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-C6-E2-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-C6-E2-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-C6-E2N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-C6-E2N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-C6-E2N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-C6-B-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-C6-B-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-C6-B-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-C6-B-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-C6-BN-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-C6-BN-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-C6-BN-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-C6-BN-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-C8-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-C8-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-C8-E0-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-C8-E0-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-C8-E0-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-C8-E0N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-C8-E0N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-C8-E0N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-C8-E2-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-C8-E2-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-C8-E2-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-C8-E2N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-C8-E2N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-C8-E2N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-C8-B-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-C8-B-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-C8-B-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-C8-B-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-C8-BN-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-C8-BN-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-C8-BN-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-C8-BN-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD219R-06-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD219R-06-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD219R-06-E0-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD219R-06-E0-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD219R-06-E0-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD219R-06-E0N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD219R-06-E0N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD219R-06-E0N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD219R-06-E2-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD219R-06-E2-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD219R-06-E2-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD219R-06-E2N-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD219R-06-E2N-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD219R-06-E2N-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD219R-06-B-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD219R-06-B-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD219R-06-B-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD219R-06-B-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD219R-06-BN-1Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD219R-06-BN-2Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD219R-06-BN-3Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD219R-06-BN-4Model: 4GD2 valve only | Switching: 2-pos single | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-C4-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-C4-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-C4-E0-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-C4-E0-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-C4-E0-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-C4-E0N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-C4-E0N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-C4-E0N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-C4-E2-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-C4-E2-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-C4-E2-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-C4-E2N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-C4-E2N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-C4-E2N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-C4-B-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-C4-B-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-C4-B-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-C4-B-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-C4-BN-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-C4-BN-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-C4-BN-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-C4-BN-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-C6-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-C6-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-C6-E0-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-C6-E0-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-C6-E0-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-C6-E0N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-C6-E0N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-C6-E0N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-C6-E2-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-C6-E2-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-C6-E2-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-C6-E2N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-C6-E2N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-C6-E2N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-C6-B-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-C6-B-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-C6-B-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-C6-B-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-C6-BN-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-C6-BN-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-C6-BN-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-C6-BN-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-C8-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-C8-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-C8-E0-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-C8-E0-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-C8-E0-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-C8-E0N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-C8-E0N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-C8-E0N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-C8-E2-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-C8-E2-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-C8-E2-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-C8-E2N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-C8-E2N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-C8-E2N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-C8-B-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-C8-B-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-C8-B-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-C8-B-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-C8-BN-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-C8-BN-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-C8-BN-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-C8-BN-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD220R-06-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD220R-06-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD220R-06-E0-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD220R-06-E0-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD220R-06-E0-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD220R-06-E0N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD220R-06-E0N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD220R-06-E0N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD220R-06-E2-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD220R-06-E2-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD220R-06-E2-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD220R-06-E2N-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD220R-06-E2N-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD220R-06-E2N-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD220R-06-B-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD220R-06-B-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD220R-06-B-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD220R-06-B-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD220R-06-BN-1Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD220R-06-BN-2Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD220R-06-BN-3Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD220R-06-BN-4Model: N4GD2 valve block | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-C4-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-C4-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-C4-E0-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-C4-E0-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-C4-E0-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-C4-E0N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-C4-E0N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-C4-E0N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-C4-E2-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-C4-E2-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-C4-E2-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-C4-E2N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-C4-E2N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-C4-E2N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-C4-B-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-C4-B-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-C4-B-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-C4-B-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-C4-BN-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-C4-BN-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-C4-BN-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-C4-BN-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-C6-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-C6-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-C6-E0-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-C6-E0-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-C6-E0-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-C6-E0N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-C6-E0N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-C6-E0N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-C6-E2-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-C6-E2-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-C6-E2-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-C6-E2N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-C6-E2N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-C6-E2N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-C6-B-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-C6-B-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-C6-B-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-C6-B-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-C6-BN-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-C6-BN-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-C6-BN-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-C6-BN-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-C8-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-C8-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-C8-E0-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-C8-E0-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-C8-E0-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-C8-E0N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-C8-E0N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-C8-E0N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-C8-E2-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-C8-E2-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-C8-E2-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-C8-E2N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-C8-E2N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-C8-E2N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-C8-B-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-C8-B-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-C8-B-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-C8-B-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-C8-BN-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-C8-BN-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-C8-BN-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-C8-BN-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD229R-06-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD229R-06-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD229R-06-E0-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD229R-06-E0-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD229R-06-E0-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD229R-06-E0N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD229R-06-E0N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD229R-06-E0N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD229R-06-E2-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD229R-06-E2-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD229R-06-E2-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD229R-06-E2N-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD229R-06-E2N-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD229R-06-E2N-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD229R-06-B-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD229R-06-B-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD229R-06-B-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD229R-06-B-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD229R-06-BN-1Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD229R-06-BN-2Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD229R-06-BN-3Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD229R-06-BN-4Model: 4GD2 valve only | Switching: 2-pos double | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-C4-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-C4-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-C4-E0-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-C4-E0-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-C4-E0-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-C4-E0N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-C4-E0N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-C4-E0N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-C4-E2-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-C4-E2-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-C4-E2-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-C4-E2N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-C4-E2N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-C4-E2N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-C4-B-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-C4-B-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-C4-B-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-C4-B-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-C4-BN-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-C4-BN-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-C4-BN-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-C4-BN-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-C6-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-C6-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-C6-E0-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-C6-E0-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-C6-E0-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-C6-E0N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-C6-E0N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-C6-E0N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-C6-E2-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-C6-E2-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-C6-E2-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-C6-E2N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-C6-E2N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-C6-E2N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-C6-B-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-C6-B-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-C6-B-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-C6-B-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-C6-BN-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-C6-BN-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-C6-BN-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-C6-BN-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-C8-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-C8-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-C8-E0-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-C8-E0-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-C8-E0-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-C8-E0N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-C8-E0N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-C8-E0N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-C8-E2-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-C8-E2-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-C8-E2-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-C8-E2N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-C8-E2N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-C8-E2N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-C8-B-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-C8-B-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-C8-B-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-C8-B-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-C8-BN-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-C8-BN-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-C8-BN-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-C8-BN-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD230R-06-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD230R-06-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD230R-06-E0-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD230R-06-E0-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD230R-06-E0-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD230R-06-E0N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD230R-06-E0N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD230R-06-E0N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD230R-06-E2-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD230R-06-E2-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD230R-06-E2-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD230R-06-E2N-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD230R-06-E2N-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD230R-06-E2N-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD230R-06-B-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD230R-06-B-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD230R-06-B-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD230R-06-B-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD230R-06-BN-1Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD230R-06-BN-2Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD230R-06-BN-3Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD230R-06-BN-4Model: N4GD2 valve block | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-C4-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-C4-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-C4-E0-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-C4-E0-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-C4-E0-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-C4-E0N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-C4-E0N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-C4-E0N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-C4-E2-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-C4-E2-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-C4-E2-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-C4-E2N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-C4-E2N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-C4-E2N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-C4-B-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-C4-B-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-C4-B-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-C4-B-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-C4-BN-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-C4-BN-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-C4-BN-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-C4-BN-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-C6-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-C6-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-C6-E0-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-C6-E0-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-C6-E0-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-C6-E0N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-C6-E0N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-C6-E0N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-C6-E2-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-C6-E2-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-C6-E2-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-C6-E2N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-C6-E2N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-C6-E2N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-C6-B-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-C6-B-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-C6-B-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-C6-B-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-C6-BN-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-C6-BN-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-C6-BN-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-C6-BN-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-C8-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-C8-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-C8-E0-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-C8-E0-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-C8-E0-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-C8-E0N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-C8-E0N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-C8-E0N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-C8-E2-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-C8-E2-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-C8-E2-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-C8-E2N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-C8-E2N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-C8-E2N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-C8-B-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-C8-B-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-C8-B-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-C8-B-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-C8-BN-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-C8-BN-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-C8-BN-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-C8-BN-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD239R-06-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD239R-06-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD239R-06-E0-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD239R-06-E0-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD239R-06-E0-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD239R-06-E0N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD239R-06-E0N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD239R-06-E0N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD239R-06-E2-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD239R-06-E2-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD239R-06-E2-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD239R-06-E2N-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD239R-06-E2N-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD239R-06-E2N-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD239R-06-B-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD239R-06-B-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD239R-06-B-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD239R-06-B-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD239R-06-BN-1Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD239R-06-BN-2Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD239R-06-BN-3Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD239R-06-BN-4Model: 4GD2 valve only | Switching: 3-pos all ports blocked | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-C4-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-C4-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-C4-E0-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-C4-E0-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-C4-E0-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-C4-E0N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-C4-E0N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-C4-E0N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-C4-E2-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-C4-E2-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-C4-E2-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-C4-E2N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-C4-E2N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-C4-E2N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-C4-B-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-C4-B-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-C4-B-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-C4-B-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-C4-BN-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-C4-BN-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-C4-BN-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-C4-BN-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-C6-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-C6-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-C6-E0-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-C6-E0-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-C6-E0-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-C6-E0N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-C6-E0N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-C6-E0N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-C6-E2-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-C6-E2-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-C6-E2-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-C6-E2N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-C6-E2N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-C6-E2N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-C6-B-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-C6-B-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-C6-B-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-C6-B-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-C6-BN-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-C6-BN-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-C6-BN-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-C6-BN-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-C8-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-C8-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-C8-E0-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-C8-E0-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-C8-E0-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-C8-E0N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-C8-E0N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-C8-E0N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-C8-E2-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-C8-E2-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-C8-E2-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-C8-E2N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-C8-E2N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-C8-E2N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-C8-B-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-C8-B-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-C8-B-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-C8-B-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-C8-BN-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-C8-BN-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-C8-BN-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-C8-BN-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD240R-06-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD240R-06-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD240R-06-E0-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD240R-06-E0-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD240R-06-E0-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD240R-06-E0N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD240R-06-E0N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD240R-06-E0N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD240R-06-E2-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD240R-06-E2-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD240R-06-E2-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD240R-06-E2N-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD240R-06-E2N-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD240R-06-E2N-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD240R-06-B-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD240R-06-B-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD240R-06-B-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD240R-06-B-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD240R-06-BN-1Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD240R-06-BN-2Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD240R-06-BN-3Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD240R-06-BN-4Model: N4GD2 valve block | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-C4-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-C4-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-C4-E0-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-C4-E0-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-C4-E0-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-C4-E0N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-C4-E0N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-C4-E0N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-C4-E2-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-C4-E2-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-C4-E2-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-C4-E2N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-C4-E2N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-C4-E2N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-C4-B-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-C4-B-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-C4-B-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-C4-B-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-C4-BN-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-C4-BN-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-C4-BN-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-C4-BN-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-C6-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-C6-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-C6-E0-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-C6-E0-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-C6-E0-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-C6-E0N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-C6-E0N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-C6-E0N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-C6-E2-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-C6-E2-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-C6-E2-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-C6-E2N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-C6-E2N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-C6-E2N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-C6-B-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-C6-B-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-C6-B-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-C6-B-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-C6-BN-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-C6-BN-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-C6-BN-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-C6-BN-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-C8-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-C8-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-C8-E0-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-C8-E0-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-C8-E0-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-C8-E0N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-C8-E0N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-C8-E0N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-C8-E2-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-C8-E2-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-C8-E2-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-C8-E2N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-C8-E2N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-C8-E2N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-C8-B-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-C8-B-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-C8-B-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-C8-B-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-C8-BN-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-C8-BN-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-C8-BN-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-C8-BN-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD249R-06-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD249R-06-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD249R-06-E0-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD249R-06-E0-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD249R-06-E0-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD249R-06-E0N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD249R-06-E0N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD249R-06-E0N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD249R-06-E2-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD249R-06-E2-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD249R-06-E2-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD249R-06-E2N-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD249R-06-E2N-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD249R-06-E2N-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD249R-06-B-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD249R-06-B-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD249R-06-B-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD249R-06-B-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD249R-06-BN-1Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD249R-06-BN-2Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD249R-06-BN-3Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD249R-06-BN-4Model: 4GD2 valve only | Switching: 3-pos A/B/R connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-C4-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-C4-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-C4-E0-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-C4-E0-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-C4-E0-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-C4-E0N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-C4-E0N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-C4-E0N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-C4-E2-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-C4-E2-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-C4-E2-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-C4-E2N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-C4-E2N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-C4-E2N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-C4-B-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-C4-B-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-C4-B-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-C4-B-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-C4-BN-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-C4-BN-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-C4-BN-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-C4-BN-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-C6-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-C6-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-C6-E0-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-C6-E0-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-C6-E0-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-C6-E0N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-C6-E0N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-C6-E0N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-C6-E2-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-C6-E2-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-C6-E2-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-C6-E2N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-C6-E2N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-C6-E2N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-C6-B-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-C6-B-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-C6-B-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-C6-B-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-C6-BN-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-C6-BN-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-C6-BN-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-C6-BN-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-C8-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-C8-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-C8-E0-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-C8-E0-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-C8-E0-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-C8-E0N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-C8-E0N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-C8-E0N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-C8-E2-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-C8-E2-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-C8-E2-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-C8-E2N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-C8-E2N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-C8-E2N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-C8-B-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-C8-B-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-C8-B-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-C8-B-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-C8-BN-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-C8-BN-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-C8-BN-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-C8-BN-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
N4GD250R-06-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
N4GD250R-06-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
N4GD250R-06-E0-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
N4GD250R-06-E0-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
N4GD250R-06-E0-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
N4GD250R-06-E0N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
N4GD250R-06-E0N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
N4GD250R-06-E0N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
N4GD250R-06-E2-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
N4GD250R-06-E2-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
N4GD250R-06-E2-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
N4GD250R-06-E2N-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
N4GD250R-06-E2N-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
N4GD250R-06-E2N-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
N4GD250R-06-B-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
N4GD250R-06-B-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
N4GD250R-06-B-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
N4GD250R-06-B-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
N4GD250R-06-BN-1Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
N4GD250R-06-BN-2Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
N4GD250R-06-BN-3Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
N4GD250R-06-BN-4Model: N4GD2 valve block | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-C4-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-C4-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-C4-E0-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-C4-E0-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-C4-E0-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-C4-E0N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-C4-E0N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-C4-E0N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-C4-E2-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-C4-E2-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-C4-E2-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-C4-E2N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-C4-E2N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-C4-E2N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-C4-B-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-C4-B-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-C4-B-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-C4-B-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-C4-BN-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-C4-BN-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-C4-BN-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-C4-BN-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-C6-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-C6-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-C6-E0-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-C6-E0-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-C6-E0-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-C6-E0N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-C6-E0N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-C6-E0N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-C6-E2-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-C6-E2-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-C6-E2-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-C6-E2N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-C6-E2N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-C6-E2N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-C6-B-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-C6-B-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-C6-B-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-C6-B-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-C6-BN-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-C6-BN-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-C6-BN-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-C6-BN-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-C8-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-C8-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-C8-E0-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-C8-E0-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-C8-E0-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-C8-E0N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-C8-E0N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-C8-E0N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-C8-E2-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-C8-E2-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-C8-E2-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-C8-E2N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-C8-E2N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-C8-E2N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-C8-B-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-C8-B-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-C8-B-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-C8-B-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-C8-BN-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-C8-BN-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-C8-BN-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-C8-BN-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V
4GD259R-06-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V
4GD259R-06-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V
4GD259R-06-E0-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V
4GD259R-06-E0-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V
4GD259R-06-E0-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V
4GD259R-06-E0N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V
4GD259R-06-E0N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V
4GD259R-06-E0N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V
4GD259R-06-E2-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V
4GD259R-06-E2-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V
4GD259R-06-E2-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V
4GD259R-06-E2N-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V
4GD259R-06-E2N-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V
4GD259R-06-E2N-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V
4GD259R-06-B-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V
4GD259R-06-B-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V
4GD259R-06-B-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V
4GD259R-06-B-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V
4GD259R-06-BN-1Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V
4GD259R-06-BN-2Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V
4GD259R-06-BN-3Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V
4GD259R-06-BN-4Model: 4GD2 valve only | Switching: 3-pos P/A/B connection | A/B fitting: Rc1/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V

Need a different model, or a part not listed here? Send us your parts list →