
Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| SCA2-G4-00-40B-25 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-50 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-75 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-100 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-150 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-200 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-250 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-300 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-350 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-400 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-450 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-00-40B-500 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-00-50B-25 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-50 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-75 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-100 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-150 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-200 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-250 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-300 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-350 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-400 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-450 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-00-50B-500 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-25 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-50 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-75 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-100 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-150 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-200 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-250 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-300 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-350 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-400 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-450 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-00-63B-500 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-00-80B-25 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-50 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-75 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-100 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-150 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-200 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-250 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-300 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-350 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-400 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-450 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-00-80B-500 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-25 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-50 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-75 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-100 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-150 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-200 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-250 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-300 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-350 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-400 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-450 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-00-100B-500 | Body: Magnet for T2YD switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-40B-25 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-50 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-75 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-100 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-150 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-200 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-250 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-300 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-350 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-400 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-450 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-40B-500 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-LB-50B-25 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-50 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-75 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-100 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-150 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-200 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-250 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-300 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-350 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-400 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-450 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-50B-500 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-25 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-50 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-75 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-100 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-150 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-200 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-250 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-300 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-350 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-400 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-450 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-63B-500 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-LB-80B-25 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-50 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-75 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-100 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-150 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-200 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-250 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-300 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-350 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-400 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-450 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-80B-500 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-25 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-50 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-75 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-100 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-150 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-200 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-250 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-300 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-350 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-400 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-450 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-LB-100B-500 | Body: Magnet for T2YD switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-40B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-40B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-FA-50B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-50B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-63B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-FA-80B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-80B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-FA-100B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-40B-25 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-50 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-75 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-100 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-150 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-200 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-250 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-300 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-350 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-400 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-450 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-40B-500 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-FB-50B-25 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-50 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-75 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-100 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-150 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-200 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-250 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-300 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-350 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-400 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-450 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-50B-500 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-25 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-50 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-75 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-100 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-150 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-200 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-250 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-300 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-350 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-400 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-450 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-63B-500 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-FB-80B-25 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-50 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-75 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-100 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-150 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-200 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-250 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-300 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-350 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-400 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-450 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-80B-500 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-25 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-50 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-75 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-100 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-150 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-200 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-250 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-300 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-350 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-400 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-450 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-FB-100B-500 | Body: Magnet for T2YD switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-40B-25 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-50 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-75 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-100 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-150 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-200 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-250 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-300 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-350 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-400 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-450 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-40B-500 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-FC-50B-25 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-50 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-75 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-100 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-150 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-200 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-250 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-300 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-350 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-400 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-450 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-50B-500 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-25 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-50 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-75 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-100 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-150 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-200 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-250 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-300 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-350 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-400 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-450 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-63B-500 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-FC-80B-25 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-50 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-75 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-100 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-150 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-200 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-250 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-300 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-350 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-400 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-450 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-80B-500 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-25 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-50 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-75 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-100 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-150 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-200 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-250 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-300 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-350 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-400 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-450 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-FC-100B-500 | Body: Magnet for T2YD switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-40B-25 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-50 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-75 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-100 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-150 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-200 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-250 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-300 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-350 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-400 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-450 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-40B-500 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-CA-50B-25 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-50 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-75 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-100 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-150 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-200 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-250 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-300 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-350 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-400 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-450 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-50B-500 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-25 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-50 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-75 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-100 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-150 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-200 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-250 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-300 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-350 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-400 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-450 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-63B-500 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-CA-80B-25 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-50 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-75 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-100 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-150 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-200 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-250 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-300 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-350 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-400 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-450 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-80B-500 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-25 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-50 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-75 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-100 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-150 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-200 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-250 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-300 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-350 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-400 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-450 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-CA-100B-500 | Body: Magnet for T2YD switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-40B-25 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-50 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-75 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-100 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-150 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-200 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-250 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-300 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-350 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-400 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-450 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-40B-500 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-CB-50B-25 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-50 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-75 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-100 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-150 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-200 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-250 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-300 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-350 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-400 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-450 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-50B-500 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-25 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-50 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-75 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-100 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-150 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-200 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-250 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-300 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-350 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-400 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-450 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-63B-500 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-CB-80B-25 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-50 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-75 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-100 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-150 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-200 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-250 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-300 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-350 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-400 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-450 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-80B-500 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-25 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-50 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-75 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-100 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-150 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-200 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-250 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-300 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-350 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-400 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-450 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-CB-100B-500 | Body: Magnet for T2YD switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-40B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-40B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-TC-50B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-50B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-63B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TC-80B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-80B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TC-100B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-40B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-40B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-TA-50B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-50B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-63B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TA-80B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-80B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-25 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-50 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-75 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-100 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-150 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-200 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-250 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-300 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-350 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-400 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-450 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TA-100B-500 | Body: Magnet for T2YD switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-40B-25 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-50 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-75 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-100 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-150 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-200 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-250 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-300 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-350 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-400 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-450 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-40B-500 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4-TB-50B-25 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-50 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-75 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-100 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-150 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-200 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-250 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-300 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-350 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-400 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-450 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-50B-500 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-25 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-50 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-75 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-100 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-150 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-200 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-250 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-300 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-350 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-400 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-450 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-63B-500 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TB-80B-25 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-50 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-75 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-100 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-150 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-200 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-250 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-300 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-350 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-400 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-450 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-80B-500 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-25 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-50 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-75 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-100 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-150 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-200 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-250 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-300 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-350 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-400 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-450 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TB-100B-500 | Body: Magnet for T2YD switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-50B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-50B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-63B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TF-80B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-80B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-25 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-50 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-75 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-100 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-150 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-200 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-250 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-300 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-350 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-400 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-450 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TF-100B-500 | Body: Magnet for T2YD switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-50B-25 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-50 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-75 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-100 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-150 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-200 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-250 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-300 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-350 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-400 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-450 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-50B-500 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-25 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-50 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-75 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-100 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-150 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-200 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-250 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-300 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-350 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-400 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-450 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-63B-500 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TD-80B-25 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-50 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-75 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-100 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-150 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-200 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-250 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-300 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-350 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-400 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-450 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-80B-500 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-25 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-50 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-75 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-100 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-150 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-200 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-250 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-300 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-350 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-400 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-450 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TD-100B-500 | Body: Magnet for T2YD switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-50B-25 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-50 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-75 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-100 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-150 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-200 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-250 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-300 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-350 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-400 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-450 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-50B-500 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-25 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-50 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-75 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-100 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-150 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-200 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-250 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-300 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-350 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-400 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-450 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-63B-500 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4-TE-80B-25 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-50 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-75 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-100 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-150 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-200 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-250 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-300 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-350 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-400 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-450 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-80B-500 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-25 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-50 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-75 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-100 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-150 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-200 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-250 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-300 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-350 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-400 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-450 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4-TE-100B-500 | Body: Magnet for T2YD switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-00-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-00-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-00-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Basic (00) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-LB-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-LB-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-LB-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Axial foot (LB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FA-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FA-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FA-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end flange (FA) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FB-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FB-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FB-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end flange (FB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-FC-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-FC-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-FC-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end special flange (FC) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CA-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CA-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CA-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Single clevis (CA) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-CB-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-CB-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-CB-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Double clevis (CB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TC-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TC-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TC-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (TC) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TA-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TA-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TA-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod-end trunnion (TA) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-40B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 25 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 50 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 75 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 100 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 150 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 200 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 250 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 300 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 350 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 400 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 450 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-40B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 40 mm | Stroke: 500 mm | Port: Rc1/4 | ||
| SCA2-G4L2-TB-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TB-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TB-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head-end trunnion (TB) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TF-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TF-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Center trunnion (hole type) (TF) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TD-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TD-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Rod trunnion (hole type) (TD) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-50B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-50B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 50 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 25 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 50 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 75 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 100 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 150 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 200 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 250 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 300 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 350 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 400 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 450 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-63B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 63 mm | Stroke: 500 mm | Port: Rc3/8 | ||
| SCA2-G4L2-TE-80B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-80B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 80 mm | Stroke: 500 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-25 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 25 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-50 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 50 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-75 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 75 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-100 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 100 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-150 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 150 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-200 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 200 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-250 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 250 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-300 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 300 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-350 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 350 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-400 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 400 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-450 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 450 mm | Port: Rc1/2 | ||
| SCA2-G4L2-TE-100B-500 | Body: Magnet for H0/H0Y switch | Mounting: Head trunnion (hole type) (TE) | Bore: 100 mm | Stroke: 500 mm | Port: Rc1/2 |
Need a different model, or a part not listed here? Send us your parts list →





