Skip to product information
1 of 1

Kyongbo Electric DIN Type Indoor Winding Current Transformer 25.8 kV WE61 Series

Kyongbo Electric DIN Type Indoor Winding Current Transformer 25.8 kV WE61 Series

Indoor epoxy vacuum-molded winding-type current transformer built to DIN 42600-8 dimensions, 25.8 kV class, for metering and protection.

Key features

  • For metering and protection
  • Indoor use
  • Winding type
  • Dimensional standard DIN 42600-8
  • Epoxy vacuum molding insulation
  • 1-core and 2-core versions

Specifications

Rated Secondary Current 5 A or 1 A
Rated Frequency 60 Hz (others on request)
Standards KS C 1706, JEC 1201, IEC 61869-2 (IEEE C57.13 on request)
WE61 Service: Metering | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~40 VA | Accuracy Class: 1.0 | Continuous Thermal Current: 1.2 In | Weight: approx. 30 kg
WE61D Service: Metering | Cores: 1 | Ratio: Double (on request) | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~40 VA | Accuracy Class: 1.0 | Weight: approx. 30 kg
WE61R Service: Protection | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~30 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Weight: approx. 30 kg
WE61DR Service: Protection | Cores: 1 | Ratio: Double (on request) | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~30 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Weight: approx. 30 kg
2WE61R Service: Metering and Protection | Cores: 2 | Ratio: Single | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Rated Burden: 15/15 or 25/25 VA (JEC) / 15/15 or 30/30 VA (IEC)
Current TransformersKyongbo Electric
5 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Kyongbo Electric DIN Type Indoor Winding Current Transformer 25.8 kV WE61 Series

Brand Kyongbo Electric·Current Transformers

Available part numbers (5)

WE61, WE61D, WE61R, WE61DR, 2WE61R

How to order

Send the Kyongbo Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
WE61Service: Metering | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~40 VA | Accuracy Class: 1.0 | Continuous Thermal Current: 1.2 In | Weight: approx. 30 kg
WE61DService: Metering | Cores: 1 | Ratio: Double (on request) | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~40 VA | Accuracy Class: 1.0 | Weight: approx. 30 kg
WE61RService: Protection | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~30 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Weight: approx. 30 kg
WE61DRService: Protection | Cores: 1 | Ratio: Double (on request) | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Rated Burden: 15~30 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Weight: approx. 30 kg
2WE61RService: Metering and Protection | Cores: 2 | Ratio: Single | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: up to 40 kA / 1 s | Rated Primary Current: up to 1200 A | Accuracy Class: 1.0/1P (JEC) / 1.0/5P, 1.0/10P (IEC) | Rated Burden: 15/15 or 25/25 VA (JEC) / 15/15 or 30/30 VA (IEC)

Need a different model, or a part not listed here? Send us your parts list →