Kyongbo Electric Indoor Winding Type Current Transformer 25.8 kV WE75B Series

Kyongbo Electric Indoor Winding Type Current Transformer 25.8 kV WE75B Series

Indoor epoxy vacuum-molded winding-type current transformer, 25.8 kV class, for metering and protection.

Key features

  • For metering and protection
  • Indoor use
  • Winding type
  • Epoxy vacuum molding insulation

Specifications

Rated Secondary Current 5 A or 1 A
Rated Frequency 60 Hz (others on request)
Standards KS C 1706, JEC 1201, IEC 61869-2 (IEEE C57.13 on request)
WE75B Service: Metering | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 0.5 or 1.0 | Continuous Thermal Current: 1.2 In | Weight: approx. 15 kg
WE75DB Service: Metering | Cores: 1 | Ratio: Double | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 0.5 or 1.0 | Continuous Thermal Current: 1.2 In | Weight: approx. 15 kg
WE75RB Service: Protection | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Continuous Thermal Current: 1.0 In (JEC) / 1.2 In (IEC) | Weight: approx. 15 kg
WE75DRB Service: Protection | Cores: 1 | Ratio: Double | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Continuous Thermal Current: 1.0 In (JEC) / 1.2 In (IEC) | Weight: approx. 15 kg
Current TransformersKyongbo Electric
4 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Kyongbo Electric Indoor Winding Type Current Transformer 25.8 kV WE75B Series

Brand Kyongbo Electric·Current Transformers

Available part numbers (4)

WE75B, WE75DB, WE75RB, WE75DRB

How to order

Send the Kyongbo Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
WE75BService: Metering | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 0.5 or 1.0 | Continuous Thermal Current: 1.2 In | Weight: approx. 15 kg
WE75DBService: Metering | Cores: 1 | Ratio: Double | Max. Voltage / Insulation (KS C 1706): 25.8 kV; 25.8/50/125 kV (20B) | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 0.5 or 1.0 | Continuous Thermal Current: 1.2 In | Weight: approx. 15 kg
WE75RBService: Protection | Cores: 1 | Ratio: Single | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Continuous Thermal Current: 1.0 In (JEC) / 1.2 In (IEC) | Weight: approx. 15 kg
WE75DRBService: Protection | Cores: 1 | Ratio: Double | Max. Voltage / Insulation (JEC 1201): 23 kV; 23/50/125 kV | Max. Voltage / Insulation (IEC 61869-2): 24 kV; 24/50/125 kV | Short-Time Current: 25 kA / 1 s | Rated Primary Current: up to 800 A or 800/400 A | Rated Burden: 15~40 VA | Accuracy Class: 1P (JEC) / 5P, 10P (IEC) | Over-Current Factor: n>10 or 20 | Continuous Thermal Current: 1.0 In (JEC) / 1.2 In (IEC) | Weight: approx. 15 kg