Key features

  • Tie-rod air cylinder with a V308 5-port solenoid valve and orifice (speed) valves mounted on the head cover
  • Valve: single solenoid (rod extends on energizing, or retracts with -B) or double solenoid (W)
  • Basic, foot, rod flange, single/double clevis (not ø40) and center trunnion mounting
  • CDV3 built-in magnet for tie-rod or band mounted auto switches (switch ordered as suffix)
  • Options as code letters: steel tube (F), bellows J/K, no cushion N, rod/head-side cushion R/H, DIN terminal (D)
  • Coil voltages AC100/200/110/220/240/48/24V, DC24/12/100/6/48/110V; made-to-order -XA, -XC4, -XC15, -XC68

Specifications

Fluid Air
Proof pressure 1.35 MPa
Max. operating pressure 0.9 MPa
Min. operating pressure 0.15 MPa
Ambient and fluid temperature -10 to 50°C (no freezing)
Cushion Air cushion
Port size Rc1/4
Solenoid valve V308, B-class coil insulation
Coil voltage / entry (listed codes) DC24V (5, 6 W), grommet
Piston speed 50 to 500 mm/s (ø100: 50 to 350 mm/s)
Source SMC Korea catalog CV series (SMCKR_CV__.pdf), p. 1216, 1217 (PDF p. 64, 65)
CV3BN40-25-5 Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-25-5 Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-25-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-25-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-25-5W Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-25-5W Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-50-5 Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-50-5 Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-50-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-50-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-50-5W Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-50-5W Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-75-5 Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-75-5 Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-75-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-75-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-75-5W Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-75-5W Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-100-5 Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-100-5 Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-100-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-100-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-100-5W Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-100-5W Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-125-5 Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-125-5 Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-125-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-125-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-125-5W Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-125-5W Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-150-5 Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-150-5 Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-150-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-150-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-150-5W Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-150-5W Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-200-5 Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-200-5 Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-200-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-200-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-200-5W Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-200-5W Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-250-5 Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-250-5 Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-250-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-250-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-250-5W Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-250-5W Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-300-5 Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-300-5 Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-300-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-300-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-300-5W Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-300-5W Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-350-5 Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-350-5 Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-350-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-350-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-350-5W Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-350-5W Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-400-5 Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-400-5 Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-400-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-400-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-400-5W Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-400-5W Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-450-5 Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-450-5 Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-450-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-450-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-450-5W Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-450-5W Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-500-5 Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-500-5 Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-500-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-500-5-B Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-500-5W Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-500-5W Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-25-5 Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-25-5 Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-25-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-25-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-25-5W Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-25-5W Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-50-5 Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-50-5 Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-50-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-50-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-50-5W Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-50-5W Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-75-5 Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-75-5 Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-75-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-75-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-75-5W Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-75-5W Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-100-5 Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-100-5 Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-100-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-100-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-100-5W Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-100-5W Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-125-5 Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-125-5 Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-125-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-125-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-125-5W Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-125-5W Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-150-5 Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-150-5 Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-150-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-150-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-150-5W Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-150-5W Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-200-5 Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-200-5 Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-200-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-200-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-200-5W Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-200-5W Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-250-5 Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-250-5 Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-250-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-250-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-250-5W Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-250-5W Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-300-5 Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-300-5 Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-300-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-300-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-300-5W Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-300-5W Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-350-5 Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-350-5 Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-350-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-350-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-350-5W Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-350-5W Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-400-5 Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-400-5 Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-400-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-400-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-400-5W Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-400-5W Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-450-5 Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-450-5 Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-450-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-450-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-450-5W Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-450-5W Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-500-5 Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-500-5 Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-500-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-500-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-500-5W Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-500-5W Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-600-5 Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-600-5 Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-600-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-600-5-B Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-600-5W Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-600-5W Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-25-5 Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-25-5 Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-25-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-25-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-25-5W Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-25-5W Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-50-5 Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-50-5 Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-50-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-50-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-50-5W Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-50-5W Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-75-5 Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-75-5 Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-75-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-75-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-75-5W Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-75-5W Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-100-5 Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-100-5 Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-100-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-100-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-100-5W Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-100-5W Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-125-5 Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-125-5 Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-125-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-125-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-125-5W Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-125-5W Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-150-5 Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-150-5 Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-150-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-150-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-150-5W Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-150-5W Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-200-5 Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-200-5 Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-200-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-200-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-200-5W Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-200-5W Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-250-5 Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-250-5 Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-250-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-250-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-250-5W Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-250-5W Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-300-5 Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-300-5 Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-300-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-300-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-300-5W Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-300-5W Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-350-5 Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-350-5 Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-350-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-350-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-350-5W Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-350-5W Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-400-5 Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-400-5 Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-400-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-400-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-400-5W Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-400-5W Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-450-5 Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-450-5 Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-450-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-450-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-450-5W Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-450-5W Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-500-5 Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-500-5 Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-500-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-500-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-500-5W Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-500-5W Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-600-5 Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-600-5 Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-600-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-600-5-B Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-600-5W Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-600-5W Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-25-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-25-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-25-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-25-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-25-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-25-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-50-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-50-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-50-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-50-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-50-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-50-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-75-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-75-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-75-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-75-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-75-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-75-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-100-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-100-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-100-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-100-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-100-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-100-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-125-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-125-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-125-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-125-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-125-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-125-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-150-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-150-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-150-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-150-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-150-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-150-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-200-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-200-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-200-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-200-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-200-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-200-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-250-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-250-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-250-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-250-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-250-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-250-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-300-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-300-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-300-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-300-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-300-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-300-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-350-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-350-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-350-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-350-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-350-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-350-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-400-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-400-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-400-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-400-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-400-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-400-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-450-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-450-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-450-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-450-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-450-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-450-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-500-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-500-5 Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-500-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-500-5-B Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-500-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-500-5W Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-25-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-25-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-25-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-25-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-25-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-25-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-50-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-50-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-50-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-50-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-50-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-50-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-75-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-75-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-75-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-75-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-75-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-75-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-100-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-100-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-100-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-100-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-100-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-100-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-125-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-125-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-125-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-125-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-125-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-125-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-150-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-150-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-150-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-150-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-150-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-150-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-200-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-200-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-200-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-200-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-200-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-200-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-250-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-250-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-250-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-250-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-250-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-250-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-300-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-300-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-300-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-300-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-300-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-300-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-350-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-350-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-350-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-350-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-350-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-350-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-400-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-400-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-400-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-400-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-400-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-400-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-450-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-450-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-450-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-450-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-450-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-450-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-500-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-500-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-500-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-500-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-500-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-500-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-600-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-600-5 Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-600-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-600-5-B Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-600-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-600-5W Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-25-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-25-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-25-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-25-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-25-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-25-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-50-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-50-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-50-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-50-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-50-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-50-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-75-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-75-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-75-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-75-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-75-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-75-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-100-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-100-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-100-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-100-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-100-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-100-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-125-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-125-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-125-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-125-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-125-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-125-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-150-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-150-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-150-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-150-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-150-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-150-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-200-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-200-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-200-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-200-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-200-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-200-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-250-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-250-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-250-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-250-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-250-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-250-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-300-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-300-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-300-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-300-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-300-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-300-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-350-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-350-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-350-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-350-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-350-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-350-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-400-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-400-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-400-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-400-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-400-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-400-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-450-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-450-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-450-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-450-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-450-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-450-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-500-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-500-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-500-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-500-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-500-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-500-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-600-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-600-5 Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-600-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-600-5-B Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-600-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-600-5W Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-25-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-25-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-25-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-25-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-25-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-25-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-50-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-50-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-50-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-50-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-50-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-50-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-75-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-75-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-75-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-75-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-75-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-75-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-100-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-100-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-100-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-100-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-100-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-100-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-125-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-125-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-125-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-125-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-125-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-125-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-150-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-150-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-150-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-150-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-150-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-150-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-200-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-200-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-200-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-200-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-200-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-200-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-250-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-250-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-250-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-250-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-250-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-250-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-300-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-300-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-300-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-300-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-300-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-300-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-350-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-350-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-350-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-350-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-350-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-350-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-400-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-400-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-400-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-400-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-400-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-400-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-450-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-450-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-450-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-450-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-450-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-450-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-500-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-500-5 Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-500-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-500-5-B Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-500-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-500-5W Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-25-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-25-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-25-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-25-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-25-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-25-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-50-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-50-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-50-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-50-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-50-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-50-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-75-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-75-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-75-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-75-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-75-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-75-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-100-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-100-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-100-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-100-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-100-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-100-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-125-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-125-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-125-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-125-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-125-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-125-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-150-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-150-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-150-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-150-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-150-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-150-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-200-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-200-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-200-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-200-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-200-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-200-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-250-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-250-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-250-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-250-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-250-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-250-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-300-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-300-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-300-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-300-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-300-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-300-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-350-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-350-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-350-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-350-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-350-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-350-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-400-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-400-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-400-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-400-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-400-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-400-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-450-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-450-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-450-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-450-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-450-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-450-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-500-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-500-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-500-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-500-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-500-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-500-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-600-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-600-5 Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-600-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-600-5-B Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-600-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-600-5W Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-25-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-25-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-25-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-25-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-25-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-25-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-50-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-50-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-50-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-50-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-50-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-50-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-75-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-75-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-75-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-75-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-75-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-75-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-100-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-100-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-100-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-100-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-100-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-100-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-125-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-125-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-125-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-125-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-125-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-125-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-150-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-150-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-150-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-150-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-150-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-150-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-200-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-200-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-200-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-200-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-200-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-200-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-250-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-250-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-250-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-250-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-250-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-250-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-300-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-300-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-300-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-300-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-300-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-300-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-350-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-350-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-350-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-350-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-350-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-350-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-400-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-400-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-400-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-400-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-400-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-400-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-450-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-450-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-450-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-450-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-450-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-450-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-500-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-500-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-500-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-500-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-500-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-500-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-600-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-600-5 Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-600-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-600-5-B Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-600-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-600-5W Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-25-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-25-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-25-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-25-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-25-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-25-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-50-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-50-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-50-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-50-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-50-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-50-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-75-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-75-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-75-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-75-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-75-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-75-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-100-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-100-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-100-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-100-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-100-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-100-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-125-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-125-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-125-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-125-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-125-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-125-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-150-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-150-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-150-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-150-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-150-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-150-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-200-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-200-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-200-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-200-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-200-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-200-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-250-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-250-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-250-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-250-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-250-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-250-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-300-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-300-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-300-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-300-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-300-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-300-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-350-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-350-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-350-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-350-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-350-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-350-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-400-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-400-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-400-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-400-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-400-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-400-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-450-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-450-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-450-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-450-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-450-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-450-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-500-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-500-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-500-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-500-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-500-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-500-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-600-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-600-5 Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-600-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-600-5-B Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-600-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-600-5W Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-25-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-25-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-25-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-25-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-25-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-25-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-50-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-50-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-50-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-50-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-50-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-50-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-75-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-75-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-75-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-75-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-75-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-75-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-100-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-100-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-100-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-100-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-100-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-100-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-125-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-125-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-125-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-125-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-125-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-125-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-150-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-150-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-150-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-150-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-150-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-150-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-200-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-200-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-200-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-200-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-200-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-200-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-250-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-250-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-250-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-250-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-250-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-250-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-300-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-300-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-300-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-300-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-300-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-300-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-350-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-350-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-350-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-350-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-350-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-350-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-400-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-400-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-400-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-400-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-400-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-400-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-450-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-450-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-450-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-450-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-450-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-450-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-500-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-500-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-500-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-500-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-500-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-500-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-600-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-600-5 Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-600-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-600-5-B Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-600-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-600-5W Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-25-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-25-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-25-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-25-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-25-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-25-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-50-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-50-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-50-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-50-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-50-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-50-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-75-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-75-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-75-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-75-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-75-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-75-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-100-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-100-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-100-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-100-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-100-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-100-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-125-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-125-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-125-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-125-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-125-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-125-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-150-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-150-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-150-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-150-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-150-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-150-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-200-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-200-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-200-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-200-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-200-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-200-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-250-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-250-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-250-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-250-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-250-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-250-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-300-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-300-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-300-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-300-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-300-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-300-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-350-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-350-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-350-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-350-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-350-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-350-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-400-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-400-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-400-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-400-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-400-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-400-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-450-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-450-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-450-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-450-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-450-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-450-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-500-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-500-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-500-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-500-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-500-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-500-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-600-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-600-5 Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-600-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-600-5-B Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-600-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-600-5W Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-25-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-25-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-25-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-25-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-25-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-25-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-50-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-50-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-50-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-50-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-50-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-50-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-75-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-75-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-75-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-75-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-75-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-75-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-100-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-100-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-100-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-100-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-100-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-100-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-125-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-125-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-125-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-125-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-125-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-125-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-150-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-150-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-150-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-150-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-150-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-150-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-200-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-200-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-200-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-200-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-200-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-200-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-250-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-250-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-250-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-250-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-250-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-250-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-300-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-300-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-300-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-300-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-300-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-300-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-350-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-350-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-350-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-350-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-350-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-350-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-400-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-400-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-400-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-400-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-400-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-400-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-450-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-450-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-450-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-450-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-450-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-450-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-500-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-500-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-500-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-500-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-500-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-500-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-600-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-600-5 Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-600-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-600-5-B Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-600-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-600-5W Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-25-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-25-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-25-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-25-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-25-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-25-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-50-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-50-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-50-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-50-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-50-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-50-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-75-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-75-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-75-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-75-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-75-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-75-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-100-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-100-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-100-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-100-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-100-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-100-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-125-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-125-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-125-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-125-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-125-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-125-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-150-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-150-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-150-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-150-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-150-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-150-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-200-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-200-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-200-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-200-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-200-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-200-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-250-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-250-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-250-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-250-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-250-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-250-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-300-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-300-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-300-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-300-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-300-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-300-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-350-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-350-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-350-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-350-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-350-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-350-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-400-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-400-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-400-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-400-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-400-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-400-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-450-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-450-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-450-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-450-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-450-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-450-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-500-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-500-5 Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-500-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-500-5-B Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-500-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-500-5W Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-25-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-25-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-25-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-25-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-25-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-25-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-50-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-50-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-50-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-50-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-50-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-50-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-75-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-75-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-75-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-75-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-75-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-75-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-100-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-100-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-100-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-100-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-100-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-100-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-125-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-125-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-125-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-125-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-125-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-125-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-150-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-150-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-150-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-150-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-150-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-150-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-200-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-200-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-200-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-200-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-200-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-200-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-250-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-250-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-250-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-250-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-250-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-250-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-300-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-300-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-300-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-300-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-300-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-300-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-350-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-350-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-350-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-350-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-350-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-350-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-400-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-400-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-400-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-400-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-400-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-400-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-450-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-450-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-450-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-450-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-450-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-450-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-500-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-500-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-500-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-500-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-500-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-500-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-600-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-600-5 Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-600-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-600-5-B Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-600-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-600-5W Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-25-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-25-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-25-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-25-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-25-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-25-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-50-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-50-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-50-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-50-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-50-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-50-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-75-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-75-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-75-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-75-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-75-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-75-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-100-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-100-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-100-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-100-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-100-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-100-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-125-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-125-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-125-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-125-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-125-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-125-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-150-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-150-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-150-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-150-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-150-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-150-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-200-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-200-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-200-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-200-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-200-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-200-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-250-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-250-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-250-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-250-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-250-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-250-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-300-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-300-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-300-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-300-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-300-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-300-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-350-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-350-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-350-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-350-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-350-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-350-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-400-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-400-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-400-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-400-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-400-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-400-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-450-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-450-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-450-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-450-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-450-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-450-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-500-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-500-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-500-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-500-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-500-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-500-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-600-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-600-5 Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-600-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-600-5-B Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-600-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-600-5W Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
Round Body CylindersSMC
1320 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC CV3 Valve Mounted Tie-rod Cylinder (ø40 to ø63)

Brand SMC·Round Body Cylinders

Available part numbers (1320)

CV3BN40-25-5, CDV3BN40-25-5, CV3BN40-25-5-B, CDV3BN40-25-5-B, CV3BN40-25-5W, CDV3BN40-25-5W, CV3BN40-50-5, CDV3BN40-50-5, CV3BN40-50-5-B, CDV3BN40-50-5-B + 1310 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
CV3BN40-25-5Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-25-5Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-25-5-BMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-25-5-BMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-25-5WMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-25-5WMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-50-5Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-50-5Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-50-5-BMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-50-5-BMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-50-5WMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-50-5WMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-75-5Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-75-5Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-75-5-BMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-75-5-BMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-75-5WMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-75-5WMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-100-5Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-100-5Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-100-5-BMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-100-5-BMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-100-5WMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-100-5WMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-125-5Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-125-5Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-125-5-BMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-125-5-BMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-125-5WMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-125-5WMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-150-5Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-150-5Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-150-5-BMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-150-5-BMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-150-5WMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-150-5WMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-200-5Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-200-5Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-200-5-BMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-200-5-BMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-200-5WMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-200-5WMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-250-5Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-250-5Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-250-5-BMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-250-5-BMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-250-5WMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-250-5WMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-300-5Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-300-5Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-300-5-BMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-300-5-BMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-300-5WMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-300-5WMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-350-5Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-350-5Mounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-350-5-BMounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-350-5-BMounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-350-5WMounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-350-5WMounting: Basic | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-400-5Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-400-5Mounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-400-5-BMounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-400-5-BMounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-400-5WMounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-400-5WMounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-450-5Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-450-5Mounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-450-5-BMounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-450-5-BMounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-450-5WMounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-450-5WMounting: Basic | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3BN40-500-5Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN40-500-5Mounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN40-500-5-BMounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN40-500-5-BMounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN40-500-5WMounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3BN40-500-5WMounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-25-5Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-25-5Mounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-25-5-BMounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-25-5-BMounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-25-5WMounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-25-5WMounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-50-5Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-50-5Mounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-50-5-BMounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-50-5-BMounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-50-5WMounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-50-5WMounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-75-5Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-75-5Mounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-75-5-BMounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-75-5-BMounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-75-5WMounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-75-5WMounting: Basic | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-100-5Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-100-5Mounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-100-5-BMounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-100-5-BMounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-100-5WMounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-100-5WMounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-125-5Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-125-5Mounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-125-5-BMounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-125-5-BMounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-125-5WMounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-125-5WMounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-150-5Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-150-5Mounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-150-5-BMounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-150-5-BMounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-150-5WMounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-150-5WMounting: Basic | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-200-5Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-200-5Mounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-200-5-BMounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-200-5-BMounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-200-5WMounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-200-5WMounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-250-5Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-250-5Mounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-250-5-BMounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-250-5-BMounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-250-5WMounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-250-5WMounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-300-5Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-300-5Mounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-300-5-BMounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-300-5-BMounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-300-5WMounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-300-5WMounting: Basic | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-350-5Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-350-5Mounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-350-5-BMounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-350-5-BMounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-350-5WMounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-350-5WMounting: Basic | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-400-5Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-400-5Mounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-400-5-BMounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-400-5-BMounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-400-5WMounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-400-5WMounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-450-5Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-450-5Mounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-450-5-BMounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-450-5-BMounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-450-5WMounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-450-5WMounting: Basic | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-500-5Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-500-5Mounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-500-5-BMounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-500-5-BMounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-500-5WMounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-500-5WMounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3BN50-600-5Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN50-600-5Mounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN50-600-5-BMounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN50-600-5-BMounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN50-600-5WMounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3BN50-600-5WMounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-25-5Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-25-5Mounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-25-5-BMounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-25-5-BMounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-25-5WMounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-25-5WMounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-50-5Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-50-5Mounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-50-5-BMounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-50-5-BMounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-50-5WMounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-50-5WMounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-75-5Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-75-5Mounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-75-5-BMounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-75-5-BMounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-75-5WMounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-75-5WMounting: Basic | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-100-5Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-100-5Mounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-100-5-BMounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-100-5-BMounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-100-5WMounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-100-5WMounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-125-5Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-125-5Mounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-125-5-BMounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-125-5-BMounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-125-5WMounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-125-5WMounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-150-5Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-150-5Mounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-150-5-BMounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-150-5-BMounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-150-5WMounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-150-5WMounting: Basic | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-200-5Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-200-5Mounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-200-5-BMounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-200-5-BMounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-200-5WMounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-200-5WMounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-250-5Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-250-5Mounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-250-5-BMounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-250-5-BMounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-250-5WMounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-250-5WMounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-300-5Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-300-5Mounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-300-5-BMounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-300-5-BMounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-300-5WMounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-300-5WMounting: Basic | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-350-5Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-350-5Mounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-350-5-BMounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-350-5-BMounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-350-5WMounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-350-5WMounting: Basic | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-400-5Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-400-5Mounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-400-5-BMounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-400-5-BMounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-400-5WMounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-400-5WMounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-450-5Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-450-5Mounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-450-5-BMounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-450-5-BMounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-450-5WMounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-450-5WMounting: Basic | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-500-5Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-500-5Mounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-500-5-BMounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-500-5-BMounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-500-5WMounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-500-5WMounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3BN63-600-5Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3BN63-600-5Mounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3BN63-600-5-BMounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3BN63-600-5-BMounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3BN63-600-5WMounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3BN63-600-5WMounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-25-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-25-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-25-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-25-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-25-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-25-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-50-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-50-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-50-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-50-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-50-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-50-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-75-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-75-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-75-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-75-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-75-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-75-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-100-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-100-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-100-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-100-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-100-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-100-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-125-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-125-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-125-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-125-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-125-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-125-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-150-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-150-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-150-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-150-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-150-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-150-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-200-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-200-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-200-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-200-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-200-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-200-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-250-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-250-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-250-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-250-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-250-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-250-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-300-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-300-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-300-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-300-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-300-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-300-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-350-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-350-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-350-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-350-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-350-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-350-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-400-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-400-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-400-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-400-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-400-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-400-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-450-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-450-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-450-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-450-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-450-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-450-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3LN40-500-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN40-500-5Mounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN40-500-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN40-500-5-BMounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN40-500-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3LN40-500-5WMounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-25-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-25-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-25-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-25-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-25-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-25-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-50-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-50-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-50-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-50-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-50-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-50-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-75-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-75-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-75-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-75-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-75-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-75-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-100-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-100-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-100-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-100-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-100-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-100-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-125-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-125-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-125-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-125-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-125-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-125-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-150-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-150-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-150-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-150-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-150-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-150-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-200-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-200-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-200-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-200-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-200-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-200-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-250-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-250-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-250-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-250-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-250-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-250-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-300-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-300-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-300-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-300-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-300-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-300-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-350-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-350-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-350-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-350-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-350-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-350-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-400-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-400-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-400-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-400-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-400-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-400-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-450-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-450-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-450-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-450-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-450-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-450-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-500-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-500-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-500-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-500-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-500-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-500-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3LN50-600-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN50-600-5Mounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN50-600-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN50-600-5-BMounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN50-600-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3LN50-600-5WMounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-25-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-25-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-25-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-25-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-25-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-25-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-50-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-50-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-50-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-50-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-50-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-50-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-75-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-75-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-75-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-75-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-75-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-75-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-100-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-100-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-100-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-100-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-100-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-100-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-125-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-125-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-125-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-125-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-125-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-125-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-150-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-150-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-150-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-150-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-150-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-150-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-200-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-200-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-200-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-200-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-200-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-200-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-250-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-250-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-250-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-250-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-250-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-250-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-300-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-300-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-300-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-300-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-300-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-300-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-350-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-350-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-350-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-350-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-350-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-350-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-400-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-400-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-400-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-400-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-400-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-400-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-450-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-450-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-450-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-450-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-450-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-450-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-500-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-500-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-500-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-500-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-500-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-500-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3LN63-600-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3LN63-600-5Mounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3LN63-600-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3LN63-600-5-BMounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3LN63-600-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3LN63-600-5WMounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-25-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-25-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-25-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-25-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-25-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-25-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-50-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-50-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-50-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-50-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-50-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-50-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-75-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-75-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-75-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-75-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-75-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-75-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-100-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-100-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-100-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-100-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-100-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-100-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-125-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-125-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-125-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-125-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-125-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-125-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-150-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-150-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-150-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-150-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-150-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-150-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-200-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-200-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-200-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-200-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-200-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-200-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-250-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-250-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-250-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-250-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-250-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-250-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-300-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-300-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-300-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-300-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-300-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-300-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-350-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-350-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-350-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-350-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-350-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-350-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-400-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-400-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-400-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-400-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-400-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-400-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-450-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-450-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-450-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-450-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-450-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-450-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3FN40-500-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN40-500-5Mounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN40-500-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN40-500-5-BMounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN40-500-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3FN40-500-5WMounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-25-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-25-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-25-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-25-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-25-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-25-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-50-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-50-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-50-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-50-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-50-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-50-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-75-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-75-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-75-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-75-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-75-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-75-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-100-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-100-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-100-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-100-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-100-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-100-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-125-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-125-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-125-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-125-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-125-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-125-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-150-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-150-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-150-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-150-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-150-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-150-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-200-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-200-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-200-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-200-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-200-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-200-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-250-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-250-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-250-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-250-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-250-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-250-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-300-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-300-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-300-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-300-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-300-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-300-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-350-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-350-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-350-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-350-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-350-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-350-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-400-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-400-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-400-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-400-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-400-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-400-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-450-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-450-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-450-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-450-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-450-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-450-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-500-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-500-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-500-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-500-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-500-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-500-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3FN50-600-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN50-600-5Mounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN50-600-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN50-600-5-BMounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN50-600-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3FN50-600-5WMounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-25-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-25-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-25-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-25-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-25-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-25-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-50-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-50-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-50-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-50-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-50-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-50-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-75-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-75-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-75-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-75-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-75-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-75-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-100-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-100-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-100-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-100-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-100-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-100-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-125-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-125-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-125-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-125-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-125-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-125-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-150-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-150-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-150-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-150-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-150-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-150-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-200-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-200-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-200-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-200-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-200-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-200-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-250-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-250-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-250-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-250-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-250-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-250-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-300-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-300-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-300-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-300-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-300-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-300-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-350-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-350-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-350-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-350-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-350-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-350-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-400-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-400-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-400-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-400-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-400-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-400-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-450-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-450-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-450-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-450-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-450-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-450-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-500-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-500-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-500-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-500-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-500-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-500-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3FN63-600-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3FN63-600-5Mounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3FN63-600-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3FN63-600-5-BMounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3FN63-600-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3FN63-600-5WMounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-25-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-25-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-25-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-25-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-25-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-25-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-50-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-50-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-50-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-50-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-50-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-50-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-75-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-75-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-75-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-75-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-75-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-75-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-100-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-100-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-100-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-100-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-100-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-100-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-125-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-125-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-125-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-125-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-125-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-125-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-150-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-150-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-150-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-150-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-150-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-150-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-200-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-200-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-200-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-200-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-200-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-200-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-250-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-250-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-250-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-250-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-250-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-250-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-300-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-300-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-300-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-300-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-300-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-300-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-350-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-350-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-350-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-350-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-350-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-350-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-400-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-400-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-400-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-400-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-400-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-400-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-450-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-450-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-450-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-450-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-450-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-450-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-500-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-500-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-500-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-500-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-500-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-500-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3CN50-600-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN50-600-5Mounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN50-600-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN50-600-5-BMounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN50-600-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3CN50-600-5WMounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-25-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-25-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-25-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-25-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-25-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-25-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-50-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-50-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-50-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-50-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-50-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-50-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-75-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-75-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-75-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-75-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-75-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-75-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-100-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-100-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-100-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-100-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-100-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-100-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-125-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-125-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-125-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-125-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-125-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-125-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-150-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-150-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-150-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-150-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-150-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-150-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-200-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-200-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-200-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-200-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-200-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-200-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-250-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-250-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-250-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-250-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-250-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-250-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-300-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-300-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-300-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-300-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-300-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-300-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-350-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-350-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-350-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-350-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-350-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-350-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-400-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-400-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-400-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-400-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-400-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-400-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-450-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-450-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-450-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-450-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-450-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-450-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-500-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-500-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-500-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-500-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-500-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-500-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3CN63-600-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3CN63-600-5Mounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3CN63-600-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3CN63-600-5-BMounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3CN63-600-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3CN63-600-5WMounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-25-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-25-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-25-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-25-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-25-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-25-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-50-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-50-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-50-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-50-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-50-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-50-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-75-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-75-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-75-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-75-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-75-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-75-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-100-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-100-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-100-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-100-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-100-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-100-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-125-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-125-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-125-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-125-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-125-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-125-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-150-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-150-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-150-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-150-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-150-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-150-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-200-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-200-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-200-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-200-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-200-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-200-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-250-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-250-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-250-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-250-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-250-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-250-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-300-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-300-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-300-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-300-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-300-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-300-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-350-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-350-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-350-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-350-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-350-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-350-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-400-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-400-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-400-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-400-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-400-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-400-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-450-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-450-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-450-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-450-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-450-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-450-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-500-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-500-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-500-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-500-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-500-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-500-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3DN50-600-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN50-600-5Mounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN50-600-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN50-600-5-BMounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN50-600-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3DN50-600-5WMounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-25-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-25-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-25-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-25-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-25-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-25-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-50-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-50-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-50-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-50-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-50-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-50-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-75-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-75-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-75-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-75-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-75-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-75-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-100-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-100-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-100-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-100-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-100-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-100-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-125-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-125-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-125-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-125-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-125-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-125-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-150-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-150-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-150-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-150-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-150-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-150-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-200-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-200-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-200-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-200-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-200-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-200-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-250-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-250-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-250-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-250-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-250-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-250-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-300-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-300-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-300-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-300-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-300-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-300-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-350-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-350-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-350-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-350-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-350-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-350-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-400-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-400-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-400-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-400-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-400-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-400-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-450-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-450-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-450-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-450-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-450-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-450-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-500-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-500-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-500-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-500-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-500-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-500-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3DN63-600-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3DN63-600-5Mounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3DN63-600-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3DN63-600-5-BMounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3DN63-600-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3DN63-600-5WMounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-25-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-25-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-25-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-25-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-25-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-25-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-50-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-50-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-50-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-50-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-50-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-50-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-75-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-75-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-75-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-75-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-75-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-75-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-100-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-100-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-100-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-100-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-100-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-100-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-125-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-125-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-125-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-125-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-125-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-125-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-150-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-150-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-150-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-150-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-150-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-150-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-200-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-200-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-200-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-200-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-200-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-200-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-250-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-250-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-250-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-250-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-250-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-250-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-300-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-300-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-300-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-300-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-300-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-300-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-350-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-350-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-350-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-350-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-350-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-350-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-400-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-400-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-400-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-400-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-400-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-400-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-450-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-450-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-450-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-450-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-450-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-450-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3TN40-500-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN40-500-5Mounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN40-500-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN40-500-5-BMounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN40-500-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3TN40-500-5WMounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-25-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-25-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-25-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-25-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-25-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-25-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-50-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-50-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-50-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-50-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-50-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-50-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-75-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-75-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-75-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-75-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-75-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-75-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-100-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-100-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-100-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-100-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-100-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-100-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-125-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-125-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-125-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-125-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-125-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-125-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-150-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-150-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-150-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-150-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-150-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-150-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-200-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-200-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-200-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-200-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-200-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-200-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-250-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-250-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-250-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-250-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-250-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-250-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-300-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-300-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-300-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-300-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-300-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-300-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-350-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-350-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-350-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-350-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-350-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-350-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-400-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-400-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-400-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-400-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-400-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-400-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-450-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-450-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-450-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-450-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-450-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-450-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-500-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-500-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-500-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-500-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-500-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-500-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3TN50-600-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN50-600-5Mounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN50-600-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN50-600-5-BMounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN50-600-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3TN50-600-5WMounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-25-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-25-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-25-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-25-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-25-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-25-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-50-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-50-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-50-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-50-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-50-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-50-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-75-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-75-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-75-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-75-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-75-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-75-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-100-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-100-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-100-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-100-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-100-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-100-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-125-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-125-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-125-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-125-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-125-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-125-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-150-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-150-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-150-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-150-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-150-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-150-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-200-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-200-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-200-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-200-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-200-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-200-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-250-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-250-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-250-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-250-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-250-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-250-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-300-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-300-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-300-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-300-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-300-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-300-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-350-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-350-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-350-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-350-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-350-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-350-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 350 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-400-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-400-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-400-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-400-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-400-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-400-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-450-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-450-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-450-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-450-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-450-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-450-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 450 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-500-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-500-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-500-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-500-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-500-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-500-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Valve: 2-pos double | Magnet: Yes
CV3TN63-600-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: No
CDV3TN63-600-5Mounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CV3TN63-600-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: No
CDV3TN63-600-5-BMounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CV3TN63-600-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: No
CDV3TN63-600-5WMounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Valve: 2-pos double | Magnet: Yes

Need a different model, or a part not listed here? Send us your parts list →