Skip to product information
1 of 1

SMC CVM5 Valve Mounted Cylinder (ø32, ø40)

SMC CVM5 Valve Mounted Cylinder (ø32, ø40)

SMC CVM5 series double acting air cylinder with an integrated SYJ5000 solenoid valve, ø32, ø40 mm bore, standard strokes 25 to 300 mm.

Key features

  • Double acting CM2-based cylinder with SYJ590 solenoid valve mounted on the cylinder
  • Valve switching: 2-position single (rod extends, or retracts with B), 2-position double, 3-position closed or exhaust center
  • Eight mountings: basic, foot, rod/head flange, single/double clevis, rod/head trunnion
  • CDVM5 built-in magnet for D-M9, D-A9 and other auto switches (switch ordered as suffix, e.g. -M9BW)
  • Options as code letters: NPT/G port (TN/TF), built-in one-touch fittings (F), bellows J/K, L/M plug or DIN (D) entry, lamp/surge S/Z/R/U, locking manual D/E
  • Other voltages DC12/6/5/3V and AC100/200/110/220V; made-to-order -XA, -XC4, -XC6

Specifications

Fluid Air
Proof pressure 1.0 MPa
Max. operating pressure 0.7 MPa
Ambient and fluid temperature -10 to 50°C (no freezing)
Cushion Rubber cushion
Lubrication Not required (non-lube)
Port size Rc1/8 (one-touch fitting ø6 type F option)
Coil voltage / entry (listed codes) DC24V (5), grommet (G)
Min. operating pressure 0.15 MPa
Solenoid valve SYJ590 series
Allowable kinetic energy 0.27 J (ø20), 0.4 J (ø25), 0.65 J (ø32), 1.2 J (ø40)
Source SMC Korea catalog CV series (SMCKR_CV__.pdf), p. 1175, 1176 (PDF p. 23, 24)
CVM5B32-25-15G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-25-15G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-25B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-25B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-25-25G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-25-25G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-25-35G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-25-35G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-25-45G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-25-45G Mounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-50-15G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-50-15G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-50B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-50B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-50-25G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-50-25G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-50-35G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-50-35G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-50-45G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-50-45G Mounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-75-15G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-75-15G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-75B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-75B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-75-25G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-75-25G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-75-35G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-75-35G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-75-45G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-75-45G Mounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-100-15G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-100-15G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-100B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-100B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-100-25G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-100-25G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-100-35G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-100-35G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-100-45G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-100-45G Mounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-125-15G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-125-15G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-125B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-125B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-125-25G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-125-25G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-125-35G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-125-35G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-125-45G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-125-45G Mounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-150-15G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-150-15G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-150B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-150B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-150-25G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-150-25G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-150-35G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-150-35G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-150-45G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-150-45G Mounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-200-15G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-200-15G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-200B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-200B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-200-25G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-200-25G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-200-35G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-200-35G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-200-45G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-200-45G Mounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-250-15G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-250-15G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-250B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-250B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-250-25G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-250-25G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-250-35G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-250-35G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-250-45G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-250-45G Mounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-300-15G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-300-15G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-300B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-300B-15G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-300-25G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-300-25G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-300-35G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-300-35G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-300-45G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-300-45G Mounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-25-15G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-25-15G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-25B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-25B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-25-25G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-25-25G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-25-35G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-25-35G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-25-45G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-25-45G Mounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-50-15G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-50-15G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-50B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-50B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-50-25G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-50-25G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-50-35G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-50-35G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-50-45G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-50-45G Mounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-75-15G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-75-15G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-75B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-75B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-75-25G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-75-25G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-75-35G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-75-35G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-75-45G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-75-45G Mounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-100-15G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-100-15G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-100B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-100B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-100-25G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-100-25G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-100-35G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-100-35G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-100-45G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-100-45G Mounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-125-15G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-125-15G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-125B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-125B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-125-25G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-125-25G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-125-35G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-125-35G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-125-45G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-125-45G Mounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-150-15G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-150-15G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-150B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-150B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-150-25G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-150-25G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-150-35G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-150-35G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-150-45G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-150-45G Mounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-200-15G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-200-15G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-200B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-200B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-200-25G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-200-25G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-200-35G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-200-35G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-200-45G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-200-45G Mounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-250-15G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-250-15G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-250B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-250B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-250-25G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-250-25G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-250-35G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-250-35G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-250-45G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-250-45G Mounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-300-15G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-300-15G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-300B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-300B-15G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-300-25G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-300-25G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-300-35G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-300-35G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-300-45G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-300-45G Mounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-25-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-25-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-25B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-25B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-25-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-25-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-25-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-25-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-25-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-25-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-50-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-50-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-50B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-50B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-50-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-50-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-50-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-50-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-50-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-50-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-75-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-75-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-75B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-75B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-75-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-75-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-75-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-75-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-75-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-75-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-100-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-100-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-100B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-100B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-100-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-100-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-100-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-100-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-100-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-100-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-125-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-125-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-125B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-125B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-125-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-125-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-125-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-125-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-125-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-125-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-150-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-150-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-150B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-150B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-150-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-150-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-150-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-150-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-150-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-150-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-200-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-200-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-200B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-200B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-200-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-200-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-200-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-200-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-200-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-200-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-250-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-250-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-250B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-250B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-250-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-250-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-250-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-250-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-250-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-250-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-300-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-300-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-300B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-300B-15G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-300-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-300-25G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-300-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-300-35G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-300-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-300-45G Mounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-25-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-25-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-25B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-25B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-25-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-25-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-25-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-25-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-25-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-25-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-50-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-50-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-50B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-50B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-50-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-50-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-50-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-50-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-50-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-50-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-75-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-75-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-75B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-75B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-75-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-75-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-75-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-75-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-75-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-75-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-100-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-100-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-100B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-100B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-100-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-100-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-100-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-100-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-100-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-100-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-125-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-125-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-125B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-125B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-125-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-125-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-125-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-125-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-125-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-125-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-150-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-150-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-150B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-150B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-150-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-150-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-150-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-150-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-150-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-150-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-200-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-200-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-200B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-200B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-200-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-200-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-200-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-200-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-200-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-200-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-250-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-250-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-250B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-250B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-250-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-250-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-250-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-250-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-250-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-250-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-300-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-300-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-300B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-300B-15G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-300-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-300-25G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-300-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-300-35G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-300-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-300-45G Mounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-25-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-25-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-25B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-25B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-25-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-25-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-25-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-25-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-25-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-25-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-50-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-50-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-50B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-50B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-50-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-50-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-50-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-50-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-50-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-50-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-75-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-75-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-75B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-75B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-75-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-75-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-75-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-75-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-75-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-75-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-100-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-100-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-100B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-100B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-100-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-100-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-100-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-100-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-100-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-100-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-125-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-125-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-125B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-125B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-125-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-125-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-125-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-125-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-125-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-125-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-150-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-150-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-150B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-150B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-150-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-150-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-150-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-150-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-150-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-150-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-200-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-200-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-200B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-200B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-200-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-200-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-200-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-200-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-200-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-200-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-250-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-250-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-250B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-250B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-250-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-250-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-250-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-250-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-250-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-250-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-300-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-300-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-300B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-300B-15G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-300-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-300-25G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-300-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-300-35G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-300-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-300-45G Mounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-25-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-25-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-25B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-25B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-25-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-25-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-25-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-25-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-25-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-25-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-50-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-50-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-50B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-50B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-50-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-50-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-50-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-50-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-50-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-50-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-75-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-75-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-75B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-75B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-75-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-75-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-75-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-75-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-75-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-75-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-100-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-100-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-100B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-100B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-100-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-100-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-100-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-100-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-100-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-100-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-125-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-125-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-125B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-125B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-125-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-125-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-125-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-125-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-125-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-125-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-150-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-150-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-150B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-150B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-150-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-150-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-150-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-150-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-150-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-150-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-200-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-200-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-200B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-200B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-200-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-200-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-200-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-200-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-200-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-200-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-250-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-250-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-250B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-250B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-250-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-250-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-250-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-250-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-250-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-250-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-300-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-300-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-300B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-300B-15G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-300-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-300-25G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-300-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-300-35G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-300-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-300-45G Mounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-25-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-25-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-25B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-25B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-25-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-25-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-25-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-25-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-25-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-25-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-50-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-50-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-50B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-50B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-50-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-50-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-50-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-50-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-50-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-50-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-75-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-75-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-75B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-75B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-75-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-75-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-75-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-75-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-75-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-75-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-100-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-100-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-100B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-100B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-100-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-100-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-100-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-100-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-100-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-100-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-125-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-125-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-125B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-125B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-125-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-125-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-125-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-125-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-125-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-125-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-150-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-150-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-150B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-150B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-150-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-150-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-150-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-150-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-150-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-150-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-200-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-200-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-200B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-200B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-200-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-200-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-200-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-200-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-200-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-200-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-250-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-250-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-250B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-250B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-250-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-250-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-250-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-250-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-250-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-250-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-300-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-300-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-300B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-300B-15G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-300-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-300-25G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-300-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-300-35G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-300-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-300-45G Mounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-25-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-25-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-25B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-25B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-25-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-25-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-25-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-25-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-25-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-25-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-50-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-50-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-50B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-50B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-50-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-50-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-50-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-50-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-50-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-50-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-75-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-75-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-75B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-75B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-75-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-75-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-75-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-75-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-75-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-75-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-100-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-100-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-100B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-100B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-100-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-100-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-100-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-100-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-100-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-100-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-125-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-125-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-125B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-125B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-125-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-125-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-125-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-125-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-125-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-125-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-150-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-150-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-150B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-150B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-150-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-150-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-150-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-150-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-150-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-150-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-200-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-200-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-200B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-200B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-200-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-200-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-200-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-200-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-200-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-200-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-250-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-250-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-250B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-250B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-250-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-250-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-250-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-250-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-250-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-250-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-300-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-300-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-300B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-300B-15G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-300-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-300-25G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-300-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-300-35G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-300-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-300-45G Mounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-25-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-25-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-25B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-25B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-25-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-25-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-25-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-25-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-25-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-25-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-50-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-50-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-50B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-50B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-50-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-50-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-50-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-50-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-50-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-50-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-75-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-75-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-75B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-75B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-75-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-75-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-75-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-75-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-75-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-75-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-100-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-100-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-100B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-100B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-100-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-100-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-100-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-100-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-100-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-100-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-125-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-125-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-125B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-125B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-125-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-125-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-125-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-125-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-125-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-125-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-150-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-150-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-150B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-150B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-150-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-150-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-150-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-150-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-150-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-150-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-200-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-200-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-200B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-200B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-200-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-200-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-200-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-200-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-200-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-200-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-250-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-250-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-250B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-250B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-250-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-250-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-250-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-250-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-250-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-250-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-300-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-300-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-300B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-300B-15G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-300-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-300-25G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-300-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-300-35G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-300-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-300-45G Mounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-25-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-25-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-25B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-25B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-25-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-25-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-25-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-25-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-25-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-25-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-50-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-50-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-50B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-50B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-50-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-50-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-50-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-50-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-50-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-50-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-75-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-75-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-75B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-75B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-75-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-75-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-75-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-75-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-75-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-75-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-100-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-100-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-100B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-100B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-100-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-100-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-100-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-100-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-100-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-100-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-125-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-125-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-125B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-125B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-125-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-125-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-125-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-125-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-125-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-125-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-150-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-150-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-150B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-150B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-150-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-150-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-150-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-150-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-150-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-150-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-200-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-200-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-200B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-200B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-200-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-200-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-200-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-200-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-200-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-200-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-250-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-250-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-250B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-250B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-250-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-250-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-250-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-250-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-250-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-250-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-300-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-300-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-300B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-300B-15G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-300-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-300-25G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-300-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-300-35G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-300-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-300-45G Mounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-25-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-25-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-25B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-25B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-25-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-25-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-25-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-25-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-25-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-25-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-50-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-50-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-50B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-50B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-50-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-50-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-50-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-50-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-50-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-50-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-75-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-75-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-75B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-75B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-75-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-75-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-75-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-75-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-75-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-75-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-100-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-100-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-100B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-100B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-100-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-100-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-100-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-100-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-100-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-100-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-125-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-125-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-125B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-125B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-125-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-125-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-125-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-125-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-125-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-125-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-150-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-150-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-150B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-150B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-150-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-150-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-150-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-150-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-150-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-150-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-200-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-200-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-200B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-200B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-200-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-200-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-200-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-200-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-200-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-200-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-250-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-250-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-250B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-250B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-250-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-250-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-250-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-250-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-250-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-250-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-300-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-300-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-300B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-300B-15G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-300-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-300-25G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-300-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-300-35G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-300-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-300-45G Mounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-25-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-25-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-25B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-25B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-25-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-25-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-25-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-25-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-25-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-25-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-50-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-50-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-50B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-50B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-50-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-50-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-50-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-50-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-50-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-50-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-75-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-75-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-75B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-75B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-75-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-75-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-75-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-75-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-75-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-75-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-100-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-100-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-100B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-100B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-100-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-100-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-100-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-100-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-100-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-100-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-125-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-125-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-125B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-125B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-125-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-125-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-125-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-125-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-125-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-125-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-150-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-150-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-150B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-150B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-150-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-150-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-150-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-150-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-150-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-150-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-200-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-200-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-200B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-200B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-200-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-200-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-200-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-200-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-200-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-200-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-250-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-250-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-250B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-250B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-250-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-250-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-250-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-250-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-250-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-250-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-300-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-300-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-300B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-300B-15G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-300-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-300-25G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-300-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-300-35G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-300-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-300-45G Mounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-25-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-25-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-25B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-25B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-25-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-25-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-25-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-25-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-25-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-25-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-50-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-50-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-50B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-50B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-50-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-50-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-50-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-50-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-50-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-50-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-75-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-75-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-75B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-75B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-75-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-75-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-75-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-75-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-75-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-75-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-100-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-100-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-100B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-100B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-100-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-100-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-100-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-100-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-100-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-100-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-125-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-125-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-125B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-125B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-125-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-125-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-125-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-125-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-125-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-125-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-150-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-150-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-150B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-150B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-150-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-150-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-150-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-150-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-150-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-150-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-200-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-200-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-200B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-200B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-200-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-200-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-200-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-200-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-200-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-200-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-250-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-250-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-250B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-250B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-250-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-250-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-250-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-250-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-250-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-250-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-300-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-300-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-300B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-300B-15G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-300-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-300-25G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-300-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-300-35G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-300-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-300-45G Mounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-25-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-25-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-25B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-25B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-25-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-25-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-25-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-25-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-25-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-25-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-50-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-50-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-50B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-50B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-50-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-50-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-50-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-50-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-50-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-50-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-75-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-75-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-75B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-75B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-75-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-75-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-75-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-75-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-75-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-75-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-100-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-100-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-100B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-100B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-100-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-100-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-100-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-100-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-100-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-100-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-125-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-125-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-125B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-125B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-125-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-125-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-125-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-125-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-125-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-125-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-150-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-150-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-150B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-150B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-150-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-150-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-150-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-150-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-150-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-150-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-200-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-200-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-200B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-200B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-200-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-200-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-200-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-200-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-200-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-200-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-250-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-250-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-250B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-250B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-250-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-250-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-250-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-250-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-250-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-250-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-300-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-300-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-300B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-300B-15G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-300-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-300-25G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-300-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-300-35G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-300-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-300-45G Mounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-25-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-25-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-25B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-25B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-25-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-25-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-25-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-25-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-25-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-25-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-50-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-50-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-50B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-50B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-50-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-50-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-50-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-50-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-50-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-50-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-75-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-75-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-75B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-75B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-75-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-75-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-75-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-75-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-75-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-75-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-100-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-100-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-100B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-100B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-100-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-100-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-100-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-100-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-100-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-100-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-125-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-125-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-125B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-125B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-125-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-125-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-125-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-125-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-125-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-125-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-150-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-150-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-150B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-150B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-150-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-150-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-150-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-150-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-150-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-150-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-200-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-200-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-200B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-200B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-200-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-200-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-200-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-200-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-200-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-200-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-250-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-250-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-250B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-250B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-250-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-250-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-250-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-250-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-250-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-250-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-300-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-300-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-300B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-300B-15G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-300-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-300-25G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-300-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-300-35G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-300-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-300-45G Mounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-25-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-25-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-25B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-25B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-25-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-25-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-25-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-25-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-25-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-25-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-50-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-50-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-50B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-50B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-50-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-50-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-50-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-50-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-50-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-50-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-75-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-75-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-75B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-75B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-75-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-75-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-75-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-75-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-75-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-75-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-100-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-100-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-100B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-100B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-100-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-100-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-100-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-100-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-100-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-100-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-125-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-125-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-125B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-125B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-125-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-125-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-125-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-125-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-125-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-125-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-150-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-150-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-150B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-150B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-150-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-150-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-150-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-150-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-150-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-150-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-200-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-200-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-200B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-200B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-200-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-200-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-200-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-200-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-200-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-200-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-250-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-250-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-250B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-250B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-250-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-250-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-250-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-250-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-250-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-250-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-300-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-300-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-300B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-300B-15G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-300-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-300-25G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-300-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-300-35G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-300-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-300-45G Mounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
Round Body CylindersSMC
1440 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC CVM5 Valve Mounted Cylinder (ø32, ø40)

Brand SMC·Round Body Cylinders

Available part numbers (1440)

CVM5B32-25-15G, CDVM5B32-25-15G, CVM5B32-25B-15G, CDVM5B32-25B-15G, CVM5B32-25-25G, CDVM5B32-25-25G, CVM5B32-25-35G, CDVM5B32-25-35G, CVM5B32-25-45G, CDVM5B32-25-45G + 1430 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
CVM5B32-25-15GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-25-15GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-25B-15GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-25B-15GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-25-25GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-25-25GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-25-35GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-25-35GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-25-45GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-25-45GMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-50-15GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-50-15GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-50B-15GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-50B-15GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-50-25GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-50-25GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-50-35GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-50-35GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-50-45GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-50-45GMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-75-15GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-75-15GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-75B-15GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-75B-15GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-75-25GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-75-25GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-75-35GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-75-35GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-75-45GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-75-45GMounting: Basic | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-100-15GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-100-15GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-100B-15GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-100B-15GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-100-25GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-100-25GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-100-35GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-100-35GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-100-45GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-100-45GMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-125-15GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-125-15GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-125B-15GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-125B-15GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-125-25GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-125-25GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-125-35GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-125-35GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-125-45GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-125-45GMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-150-15GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-150-15GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-150B-15GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-150B-15GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-150-25GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-150-25GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-150-35GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-150-35GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-150-45GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-150-45GMounting: Basic | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-200-15GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-200-15GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-200B-15GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-200B-15GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-200-25GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-200-25GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-200-35GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-200-35GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-200-45GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-200-45GMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-250-15GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-250-15GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-250B-15GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-250B-15GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-250-25GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-250-25GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-250-35GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-250-35GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-250-45GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-250-45GMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B32-300-15GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B32-300-15GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B32-300B-15GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B32-300B-15GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B32-300-25GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5B32-300-25GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5B32-300-35GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B32-300-35GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B32-300-45GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B32-300-45GMounting: Basic | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-25-15GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-25-15GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-25B-15GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-25B-15GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-25-25GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-25-25GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-25-35GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-25-35GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-25-45GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-25-45GMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-50-15GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-50-15GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-50B-15GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-50B-15GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-50-25GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-50-25GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-50-35GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-50-35GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-50-45GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-50-45GMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-75-15GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-75-15GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-75B-15GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-75B-15GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-75-25GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-75-25GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-75-35GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-75-35GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-75-45GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-75-45GMounting: Basic | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-100-15GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-100-15GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-100B-15GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-100B-15GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-100-25GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-100-25GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-100-35GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-100-35GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-100-45GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-100-45GMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-125-15GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-125-15GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-125B-15GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-125B-15GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-125-25GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-125-25GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-125-35GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-125-35GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-125-45GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-125-45GMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-150-15GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-150-15GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-150B-15GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-150B-15GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-150-25GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-150-25GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-150-35GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-150-35GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-150-45GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-150-45GMounting: Basic | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-200-15GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-200-15GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-200B-15GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-200B-15GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-200-25GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-200-25GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-200-35GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-200-35GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-200-45GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-200-45GMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-250-15GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-250-15GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-250B-15GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-250B-15GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-250-25GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-250-25GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-250-35GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-250-35GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-250-45GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-250-45GMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5B40-300-15GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5B40-300-15GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5B40-300B-15GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5B40-300B-15GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5B40-300-25GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5B40-300-25GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5B40-300-35GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5B40-300-35GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5B40-300-45GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5B40-300-45GMounting: Basic | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-25-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-25-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-25B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-25B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-25-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-25-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-25-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-25-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-25-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-25-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-50-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-50-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-50B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-50B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-50-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-50-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-50-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-50-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-50-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-50-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-75-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-75-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-75B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-75B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-75-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-75-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-75-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-75-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-75-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-75-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-100-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-100-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-100B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-100B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-100-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-100-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-100-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-100-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-100-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-100-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-125-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-125-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-125B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-125B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-125-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-125-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-125-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-125-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-125-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-125-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-150-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-150-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-150B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-150B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-150-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-150-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-150-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-150-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-150-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-150-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-200-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-200-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-200B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-200B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-200-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-200-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-200-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-200-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-200-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-200-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-250-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-250-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-250B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-250B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-250-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-250-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-250-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-250-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-250-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-250-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L32-300-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L32-300-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L32-300B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L32-300B-15GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L32-300-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5L32-300-25GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5L32-300-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L32-300-35GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L32-300-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L32-300-45GMounting: Axial foot | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-25-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-25-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-25B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-25B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-25-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-25-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-25-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-25-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-25-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-25-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-50-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-50-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-50B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-50B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-50-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-50-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-50-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-50-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-50-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-50-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-75-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-75-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-75B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-75B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-75-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-75-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-75-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-75-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-75-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-75-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-100-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-100-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-100B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-100B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-100-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-100-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-100-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-100-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-100-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-100-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-125-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-125-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-125B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-125B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-125-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-125-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-125-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-125-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-125-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-125-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-150-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-150-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-150B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-150B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-150-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-150-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-150-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-150-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-150-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-150-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-200-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-200-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-200B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-200B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-200-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-200-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-200-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-200-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-200-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-200-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-250-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-250-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-250B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-250B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-250-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-250-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-250-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-250-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-250-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-250-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5L40-300-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5L40-300-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5L40-300B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5L40-300B-15GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5L40-300-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5L40-300-25GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5L40-300-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5L40-300-35GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5L40-300-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5L40-300-45GMounting: Axial foot | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-25-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-25-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-25B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-25B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-25-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-25-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-25-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-25-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-25-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-25-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-50-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-50-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-50B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-50B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-50-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-50-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-50-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-50-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-50-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-50-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-75-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-75-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-75B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-75B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-75-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-75-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-75-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-75-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-75-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-75-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-100-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-100-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-100B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-100B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-100-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-100-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-100-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-100-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-100-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-100-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-125-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-125-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-125B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-125B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-125-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-125-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-125-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-125-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-125-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-125-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-150-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-150-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-150B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-150B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-150-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-150-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-150-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-150-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-150-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-150-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-200-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-200-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-200B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-200B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-200-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-200-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-200-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-200-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-200-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-200-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-250-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-250-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-250B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-250B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-250-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-250-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-250-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-250-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-250-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-250-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F32-300-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F32-300-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F32-300B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F32-300B-15GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F32-300-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5F32-300-25GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5F32-300-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F32-300-35GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F32-300-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F32-300-45GMounting: Rod flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-25-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-25-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-25B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-25B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-25-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-25-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-25-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-25-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-25-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-25-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-50-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-50-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-50B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-50B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-50-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-50-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-50-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-50-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-50-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-50-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-75-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-75-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-75B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-75B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-75-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-75-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-75-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-75-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-75-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-75-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-100-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-100-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-100B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-100B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-100-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-100-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-100-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-100-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-100-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-100-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-125-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-125-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-125B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-125B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-125-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-125-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-125-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-125-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-125-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-125-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-150-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-150-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-150B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-150B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-150-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-150-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-150-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-150-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-150-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-150-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-200-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-200-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-200B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-200B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-200-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-200-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-200-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-200-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-200-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-200-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-250-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-250-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-250B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-250B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-250-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-250-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-250-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-250-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-250-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-250-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5F40-300-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5F40-300-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5F40-300B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5F40-300B-15GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5F40-300-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5F40-300-25GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5F40-300-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5F40-300-35GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5F40-300-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5F40-300-45GMounting: Rod flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-25-15GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-25-15GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-25B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-25B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-25-25GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-25-25GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-25-35GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-25-35GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-25-45GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-25-45GMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-50-15GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-50-15GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-50B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-50B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-50-25GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-50-25GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-50-35GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-50-35GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-50-45GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-50-45GMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-75-15GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-75-15GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-75B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-75B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-75-25GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-75-25GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-75-35GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-75-35GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-75-45GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-75-45GMounting: Head flange | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-100-15GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-100-15GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-100B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-100B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-100-25GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-100-25GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-100-35GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-100-35GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-100-45GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-100-45GMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-125-15GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-125-15GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-125B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-125B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-125-25GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-125-25GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-125-35GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-125-35GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-125-45GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-125-45GMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-150-15GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-150-15GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-150B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-150B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-150-25GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-150-25GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-150-35GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-150-35GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-150-45GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-150-45GMounting: Head flange | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-200-15GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-200-15GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-200B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-200B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-200-25GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-200-25GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-200-35GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-200-35GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-200-45GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-200-45GMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-250-15GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-250-15GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-250B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-250B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-250-25GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-250-25GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-250-35GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-250-35GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-250-45GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-250-45GMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G32-300-15GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G32-300-15GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G32-300B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G32-300B-15GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G32-300-25GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5G32-300-25GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5G32-300-35GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G32-300-35GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G32-300-45GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G32-300-45GMounting: Head flange | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-25-15GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-25-15GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-25B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-25B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-25-25GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-25-25GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-25-35GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-25-35GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-25-45GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-25-45GMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-50-15GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-50-15GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-50B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-50B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-50-25GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-50-25GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-50-35GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-50-35GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-50-45GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-50-45GMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-75-15GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-75-15GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-75B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-75B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-75-25GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-75-25GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-75-35GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-75-35GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-75-45GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-75-45GMounting: Head flange | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-100-15GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-100-15GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-100B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-100B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-100-25GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-100-25GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-100-35GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-100-35GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-100-45GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-100-45GMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-125-15GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-125-15GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-125B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-125B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-125-25GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-125-25GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-125-35GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-125-35GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-125-45GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-125-45GMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-150-15GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-150-15GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-150B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-150B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-150-25GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-150-25GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-150-35GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-150-35GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-150-45GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-150-45GMounting: Head flange | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-200-15GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-200-15GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-200B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-200B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-200-25GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-200-25GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-200-35GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-200-35GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-200-45GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-200-45GMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-250-15GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-250-15GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-250B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-250B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-250-25GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-250-25GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-250-35GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-250-35GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-250-45GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-250-45GMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5G40-300-15GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5G40-300-15GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5G40-300B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5G40-300B-15GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5G40-300-25GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5G40-300-25GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5G40-300-35GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5G40-300-35GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5G40-300-45GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5G40-300-45GMounting: Head flange | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-25-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-25-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-25B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-25B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-25-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-25-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-25-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-25-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-25-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-25-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-50-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-50-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-50B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-50B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-50-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-50-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-50-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-50-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-50-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-50-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-75-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-75-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-75B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-75B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-75-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-75-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-75-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-75-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-75-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-75-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-100-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-100-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-100B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-100B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-100-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-100-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-100-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-100-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-100-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-100-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-125-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-125-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-125B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-125B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-125-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-125-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-125-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-125-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-125-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-125-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-150-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-150-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-150B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-150B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-150-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-150-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-150-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-150-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-150-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-150-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-200-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-200-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-200B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-200B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-200-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-200-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-200-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-200-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-200-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-200-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-250-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-250-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-250B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-250B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-250-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-250-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-250-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-250-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-250-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-250-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C32-300-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C32-300-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C32-300B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C32-300B-15GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C32-300-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5C32-300-25GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5C32-300-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C32-300-35GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C32-300-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C32-300-45GMounting: Single clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-25-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-25-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-25B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-25B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-25-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-25-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-25-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-25-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-25-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-25-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-50-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-50-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-50B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-50B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-50-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-50-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-50-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-50-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-50-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-50-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-75-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-75-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-75B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-75B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-75-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-75-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-75-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-75-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-75-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-75-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-100-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-100-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-100B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-100B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-100-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-100-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-100-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-100-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-100-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-100-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-125-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-125-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-125B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-125B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-125-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-125-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-125-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-125-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-125-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-125-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-150-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-150-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-150B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-150B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-150-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-150-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-150-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-150-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-150-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-150-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-200-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-200-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-200B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-200B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-200-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-200-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-200-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-200-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-200-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-200-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-250-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-250-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-250B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-250B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-250-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-250-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-250-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-250-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-250-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-250-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5C40-300-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5C40-300-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5C40-300B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5C40-300B-15GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5C40-300-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5C40-300-25GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5C40-300-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5C40-300-35GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5C40-300-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5C40-300-45GMounting: Single clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-25-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-25-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-25B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-25B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-25-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-25-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-25-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-25-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-25-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-25-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-50-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-50-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-50B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-50B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-50-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-50-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-50-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-50-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-50-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-50-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-75-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-75-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-75B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-75B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-75-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-75-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-75-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-75-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-75-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-75-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-100-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-100-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-100B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-100B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-100-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-100-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-100-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-100-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-100-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-100-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-125-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-125-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-125B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-125B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-125-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-125-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-125-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-125-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-125-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-125-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-150-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-150-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-150B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-150B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-150-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-150-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-150-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-150-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-150-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-150-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-200-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-200-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-200B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-200B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-200-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-200-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-200-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-200-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-200-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-200-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-250-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-250-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-250B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-250B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-250-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-250-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-250-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-250-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-250-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-250-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D32-300-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D32-300-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D32-300B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D32-300B-15GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D32-300-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5D32-300-25GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5D32-300-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D32-300-35GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D32-300-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D32-300-45GMounting: Double clevis | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-25-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-25-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-25B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-25B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-25-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-25-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-25-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-25-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-25-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-25-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-50-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-50-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-50B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-50B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-50-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-50-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-50-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-50-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-50-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-50-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-75-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-75-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-75B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-75B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-75-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-75-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-75-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-75-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-75-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-75-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-100-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-100-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-100B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-100B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-100-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-100-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-100-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-100-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-100-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-100-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-125-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-125-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-125B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-125B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-125-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-125-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-125-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-125-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-125-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-125-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-150-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-150-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-150B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-150B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-150-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-150-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-150-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-150-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-150-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-150-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-200-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-200-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-200B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-200B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-200-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-200-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-200-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-200-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-200-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-200-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-250-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-250-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-250B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-250B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-250-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-250-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-250-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-250-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-250-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-250-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5D40-300-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5D40-300-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5D40-300B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5D40-300B-15GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5D40-300-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5D40-300-25GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5D40-300-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5D40-300-35GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5D40-300-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5D40-300-45GMounting: Double clevis | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-25-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-25-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-25B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-25B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-25-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-25-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-25-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-25-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-25-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-25-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-50-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-50-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-50B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-50B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-50-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-50-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-50-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-50-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-50-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-50-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-75-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-75-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-75B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-75B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-75-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-75-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-75-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-75-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-75-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-75-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-100-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-100-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-100B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-100B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-100-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-100-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-100-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-100-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-100-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-100-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-125-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-125-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-125B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-125B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-125-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-125-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-125-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-125-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-125-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-125-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-150-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-150-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-150B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-150B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-150-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-150-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-150-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-150-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-150-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-150-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-200-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-200-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-200B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-200B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-200-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-200-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-200-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-200-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-200-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-200-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-250-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-250-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-250B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-250B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-250-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-250-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-250-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-250-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-250-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-250-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T32-300-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T32-300-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T32-300B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T32-300B-15GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T32-300-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5T32-300-25GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5T32-300-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T32-300-35GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T32-300-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T32-300-45GMounting: Head trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-25-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-25-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-25B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-25B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-25-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-25-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-25-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-25-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-25-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-25-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-50-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-50-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-50B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-50B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-50-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-50-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-50-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-50-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-50-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-50-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-75-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-75-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-75B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-75B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-75-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-75-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-75-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-75-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-75-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-75-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-100-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-100-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-100B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-100B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-100-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-100-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-100-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-100-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-100-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-100-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-125-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-125-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-125B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-125B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-125-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-125-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-125-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-125-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-125-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-125-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-150-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-150-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-150B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-150B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-150-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-150-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-150-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-150-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-150-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-150-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-200-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-200-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-200B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-200B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-200-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-200-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-200-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-200-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-200-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-200-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-250-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-250-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-250B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-250B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-250-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-250-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-250-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-250-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-250-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-250-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5T40-300-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5T40-300-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5T40-300B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5T40-300B-15GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5T40-300-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5T40-300-25GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5T40-300-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5T40-300-35GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5T40-300-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5T40-300-45GMounting: Head trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-25-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-25-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-25B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-25B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-25-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-25-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-25-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-25-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-25-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-25-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-50-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-50-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-50B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-50B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-50-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-50-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-50-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-50-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-50-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-50-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-75-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-75-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-75B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-75B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-75-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-75-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-75-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-75-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-75-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-75-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-100-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-100-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-100B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-100B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-100-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-100-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-100-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-100-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-100-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-100-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-125-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-125-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-125B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-125B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-125-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-125-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-125-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-125-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-125-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-125-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-150-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-150-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-150B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-150B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-150-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-150-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-150-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-150-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-150-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-150-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-200-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-200-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-200B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-200B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-200-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-200-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-200-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-200-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-200-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-200-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-250-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-250-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-250B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-250B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-250-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-250-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-250-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-250-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-250-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-250-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U32-300-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U32-300-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U32-300B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U32-300B-15GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U32-300-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5U32-300-25GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5U32-300-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U32-300-35GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U32-300-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U32-300-45GMounting: Rod trunnion | Bore: ø32 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-25-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-25-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-25B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-25B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-25-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-25-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-25-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-25-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-25-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-25-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 25 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-50-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-50-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-50B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-50B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-50-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-50-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-50-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-50-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-50-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-50-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 50 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-75-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-75-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-75B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-75B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-75-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-75-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-75-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-75-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-75-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-75-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 75 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-100-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-100-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-100B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-100B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-100-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-100-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-100-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-100-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-100-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-100-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 100 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-125-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-125-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-125B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-125B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-125-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-125-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-125-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-125-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-125-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-125-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 125 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-150-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-150-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-150B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-150B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-150-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-150-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-150-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-150-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-150-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-150-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 150 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-200-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-200-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-200B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-200B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-200-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-200-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-200-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-200-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-200-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-200-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 200 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-250-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-250-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-250B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-250B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-250-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-250-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-250-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-250-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-250-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-250-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 250 mm | Valve: 3-pos exhaust center | Magnet: Yes
CVM5U40-300-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: No
CDVM5U40-300-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized extend | Magnet: Yes
CVM5U40-300B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: No
CDVM5U40-300B-15GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos single, energized retract | Magnet: Yes
CVM5U40-300-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: No
CDVM5U40-300-25GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 2-pos double | Magnet: Yes
CVM5U40-300-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: No
CDVM5U40-300-35GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos closed center | Magnet: Yes
CVM5U40-300-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: No
CDVM5U40-300-45GMounting: Rod trunnion | Bore: ø40 mm | Stroke: 300 mm | Valve: 3-pos exhaust center | Magnet: Yes

Need a different model, or a part not listed here? Send us your parts list →