
Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| LVQ20-V03 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ20-V03R | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ20-V03-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V03R-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V03-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ20-V03R-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ20-V03-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V03R-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V03-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V03R-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V03-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V03R-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V03-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ20-V03R-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ20-V03-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V03R-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V03-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V03R-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V03-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V03R-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V03-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ20-V03R-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ20-V03-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V03R-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V03-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V03R-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V03-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V03R-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V03-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V03R-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V03-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V03R-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V03-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V03R-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V03-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V03R-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V03-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V03R-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V03-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V03R-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V03-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V03R-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V03-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V03R-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V03-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V03-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V03R-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V03-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V03R-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V03-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V03R-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ21-V03 | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ21-V03R | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ21-V03-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V03R-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V03-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ21-V03R-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ21-V03-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ21-V03R-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V03 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ22-V03R | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ22-V03-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V03R-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V03-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ22-V03R-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ22-V03-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V03R-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V03-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ22-V03R-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ22-V03-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V03R-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V03-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ22-V03R-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ20-V04R | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ20-V04-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V04R-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V04-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ20-V04R-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ20-V04-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V04R-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V04-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V04R-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V04-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V04R-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V04-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ20-V04R-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ20-V04-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V04R-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V04-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V04R-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V04-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V04R-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V04-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ20-V04R-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ20-V04-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V04R-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V04-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V04R-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V04-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V04R-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V04-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V04R-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V04-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V04R-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V04-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V04R-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V04-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V04R-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V04-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V04R-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V04-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V04R-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V04-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V04R-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V04-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V04R-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V04-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V04-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V04R-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V04-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V04R-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V04-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V04R-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ21-V04 | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ21-V04R | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ21-V04-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V04R-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V04-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ21-V04R-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ21-V04-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ21-V04R-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V04 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ22-V04R | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ22-V04-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V04R-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V04-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ22-V04R-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ22-V04-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V04R-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V04-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ22-V04R-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ22-V04-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V04R-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V04-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ22-V04R-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ20-V06R | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ20-V06-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V06R-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V06-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ20-V06R-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ20-V06-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V06R-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V06-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V06R-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V06-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V06R-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V06-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ20-V06R-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ20-V06-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V06R-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V06-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V06R-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V06-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V06R-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V06-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ20-V06R-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ20-V06-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V06R-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V06-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V06R-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V06-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V06R-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V06-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V06R-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V06-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V06R-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V06-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V06R-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V06-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V06R-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V06-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V06R-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V06-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V06R-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V06-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V06R-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V06-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V06R-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V06-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V06-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V06R-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V06-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V06R-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V06-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V06R-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ21-V06 | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ21-V06R | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ21-V06-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V06R-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V06-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ21-V06R-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ21-V06-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ21-V06R-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V06 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ22-V06R | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ22-V06-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V06R-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V06-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ22-V06R-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ22-V06-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V06R-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V06-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ22-V06R-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ22-V06-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V06R-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V06-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ22-V06R-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ20-V05R | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ20-V05-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V05R-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V05-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ20-V05R-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ20-V05-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V05R-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V05-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V05R-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V05-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V05R-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V05-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ20-V05R-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ20-V05-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V05R-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V05-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V05R-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V05-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V05R-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V05-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ20-V05R-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ20-V05-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V05R-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V05-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V05R-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V05-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V05R-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V05-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V05R-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V05-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V05R-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V05-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V05R-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V05-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V05R-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V05-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V05R-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V05-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V05R-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V05-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V05R-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V05-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V05R-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V05-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V05-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V05R-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V05-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V05R-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V05-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V05R-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ21-V05 | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ21-V05R | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ21-V05-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V05R-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V05-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ21-V05R-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ21-V05-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ21-V05R-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V05 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ22-V05R | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ22-V05-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V05R-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V05-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ22-V05R-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ22-V05-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V05R-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V05-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ22-V05R-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ22-V05-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V05R-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V05-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ22-V05R-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ20-V07R | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ20-V07-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V07R-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V07-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ20-V07R-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ20-V07-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V07R-1 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ20-V07-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V07R-1-J | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ20-V07-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V07R-1-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ20-V07-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-1-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ20-V07R-2 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ20-V07-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V07R-2-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ20-V07-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-2-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V07R-3 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V07-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V07R-3-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V07-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-3-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ20-V07R-4 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ20-V07-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V07R-4-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ20-V07-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-4-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V07R-5 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ20-V07-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V07R-5-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ20-V07-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-5-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V07R-6 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ20-V07-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V07R-6-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ20-V07-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-6-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V07R-7 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ20-V07-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V07R-7-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ20-V07-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-7-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V07R-8 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ20-V07-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V07R-8-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ20-V07-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-8-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V07R-9 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ20-V07-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V07R-9-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ20-V07-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-9-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ20-V07-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V07R-24 | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ20-V07-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V07R-24-K | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ20-V07-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ20-V07R-24-N | Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ21-V07 | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ21-V07R | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ21-V07-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V07R-J | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ21-V07-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ21-V07R-K | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ21-V07-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ21-V07R-N | Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V07 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ22-V07R | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ22-V07-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V07R-J | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ22-V07-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ22-V07R-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ22-V07-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V07R-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ22-V07-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ22-V07R-2 | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ22-V07-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V07R-2-K | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ22-V07-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ22-V07R-2-N | Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ30-V06R | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ30-V06-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V06R-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V06-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ30-V06R-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ30-V06-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V06R-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V06-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V06R-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V06-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V06R-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V06-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ30-V06R-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ30-V06-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V06R-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V06-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V06R-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V06-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V06R-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V06-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ30-V06R-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ30-V06-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V06R-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V06-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V06R-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V06-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V06R-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V06-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V06R-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V06-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V06R-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V06-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V06R-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V06-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V06R-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V06-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V06R-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V06-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V06R-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V06-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V06R-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V06-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V06R-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V06-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V06-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V06R-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V06-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V06R-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V06-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V06R-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ31-V06 | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ31-V06R | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ31-V06-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V06R-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V06-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ31-V06R-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ31-V06-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ31-V06R-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V06 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ32-V06R | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ32-V06-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V06R-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V06-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ32-V06R-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ32-V06-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V06R-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V06-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ32-V06R-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ32-V06-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V06R-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V06-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ32-V06R-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ30-V08R | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ30-V08-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V08R-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V08-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ30-V08R-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ30-V08-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V08R-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V08-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V08R-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V08-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V08R-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V08-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ30-V08R-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ30-V08-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V08R-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V08-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V08R-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V08-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V08R-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V08-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ30-V08R-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ30-V08-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V08R-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V08-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V08R-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V08-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V08R-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V08-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V08R-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V08-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V08R-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V08-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V08R-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V08-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V08R-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V08-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V08R-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V08-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V08R-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V08-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V08R-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V08-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V08R-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V08-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V08-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V08R-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V08-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V08R-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V08-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V08R-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ31-V08 | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ31-V08R | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ31-V08-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V08R-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V08-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ31-V08R-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ31-V08-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ31-V08R-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V08 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ32-V08R | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ32-V08-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V08R-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V08-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ32-V08R-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ32-V08-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V08R-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V08-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ32-V08R-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ32-V08-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V08R-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V08-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ32-V08R-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ30-V10R | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ30-V10-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V10R-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V10-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ30-V10R-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ30-V10-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V10R-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V10-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V10R-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V10-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V10R-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V10-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ30-V10R-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ30-V10-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V10R-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V10-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V10R-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V10-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V10R-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V10-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ30-V10R-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ30-V10-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V10R-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V10-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V10R-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V10-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V10R-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V10-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V10R-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V10-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V10R-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V10-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V10R-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V10-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V10R-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V10-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V10R-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V10-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V10R-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V10-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V10R-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V10-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V10R-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V10-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V10-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V10R-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V10-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V10R-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V10-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V10R-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ31-V10 | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ31-V10R | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ31-V10-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V10R-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V10-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ31-V10R-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ31-V10-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ31-V10R-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V10 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ32-V10R | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ32-V10-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V10R-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V10-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ32-V10R-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ32-V10-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V10R-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V10-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ32-V10R-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ32-V10-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V10R-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V10-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ32-V10R-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ30-V07R | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ30-V07-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V07R-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V07-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ30-V07R-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ30-V07-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V07R-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V07-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V07R-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V07-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V07R-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V07-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ30-V07R-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ30-V07-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V07R-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V07-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V07R-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V07-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V07R-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V07-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ30-V07R-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ30-V07-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V07R-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V07-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V07R-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V07-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V07R-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V07-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V07R-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V07-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V07R-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V07-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V07R-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V07-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V07R-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V07-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V07R-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V07-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V07R-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V07-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V07R-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V07-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V07R-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V07-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V07-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V07R-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V07-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V07R-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V07-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V07R-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ31-V07 | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ31-V07R | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ31-V07-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V07R-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V07-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ31-V07R-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ31-V07-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ31-V07R-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V07 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ32-V07R | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ32-V07-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V07R-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V07-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ32-V07R-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ32-V07-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V07R-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V07-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ32-V07R-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ32-V07-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V07R-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V07-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ32-V07R-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ30-V11R | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ30-V11-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V11R-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V11-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ30-V11R-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ30-V11-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V11R-1 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM | ||
| LVQ30-V11-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V11R-1-J | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C | ||
| LVQ30-V11-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V11R-1-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM | ||
| LVQ30-V11-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-1-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ30-V11R-2 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ30-V11-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V11R-2-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ30-V11-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-2-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V11R-3 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V11-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V11R-3-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V11-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-3-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM | ||
| LVQ30-V11R-4 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM | ||
| LVQ30-V11-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V11R-4-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM | ||
| LVQ30-V11-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-4-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V11R-5 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM | ||
| LVQ30-V11-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V11R-5-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM | ||
| LVQ30-V11-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-5-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V11R-6 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM | ||
| LVQ30-V11-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V11R-6-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM | ||
| LVQ30-V11-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-6-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V11R-7 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM | ||
| LVQ30-V11-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V11R-7-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM | ||
| LVQ30-V11-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-7-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V11R-8 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM | ||
| LVQ30-V11-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V11R-8-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM | ||
| LVQ30-V11-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-8-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V11R-9 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM | ||
| LVQ30-V11-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V11R-9-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM | ||
| LVQ30-V11-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-9-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia) | ||
| LVQ30-V11-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V11R-24 | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM | ||
| LVQ30-V11-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V11R-24-K | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM | ||
| LVQ30-V11-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ30-V11R-24-N | Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia) | ||
| LVQ31-V11 | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ31-V11R | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ31-V11-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V11R-J | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ31-V11-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ31-V11R-K | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ31-V11-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ31-V11R-N | Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V11 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM | ||
| LVQ32-V11R | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM | ||
| LVQ32-V11-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V11R-J | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C | ||
| LVQ32-V11-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM | ||
| LVQ32-V11R-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM | ||
| LVQ32-V11-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V11R-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia) | ||
| LVQ32-V11-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM | ||
| LVQ32-V11R-2 | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM | ||
| LVQ32-V11-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V11R-2-K | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM | ||
| LVQ32-V11-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia) | ||
| LVQ32-V11R-2-N | Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia) |
Need a different model, or a part not listed here? Send us your parts list →





