Key features

  • Fluid-contact parts New PFA body and PTFE diaphragm; PVDF actuator joined without metal screws (non-metal exterior)
  • Piston damper and tapered flow path reduce particles, micro-bubbles and liquid retention
  • Pilot port can be oriented in 8 directions (P2 to P8 suffix, standard direction 1)
  • Options: flow adjustment, bypass, indicator, high back pressure 0.42 MPa; buffer FKM, FFKM, EPDM (ammonia) or high-temperature 170 C
  • Pilot port also available with LQ fitting for 4x3 tube (M) and NPT1/8 (N); reducer B-port sizes on order

Specifications

Fluid Deionized water, chemicals (see compatibility list)
Fluid connection LQ1 hyper fitting (insert bushing) integrated
Proof pressure 1 MPa
Operating pressure (A to B) -98 kPa to 0.5 MPa (LVQ60 0.4 MPa)
Back pressure 0.3 MPa or less (LVQ60 0.2 MPa); high BP 0.42 MPa
Pilot pressure 0.3 to 0.5 MPa (high BP 0.45 to 0.55 MPa)
Flow Cv (class 2/3/4/5/6) 0.35 / 1.3 / 1.9 / 5 / 8 (high flow 9.5)
Fluid temperature 0 to 100 C (high temp. 0 to 170 C)
Ambient temperature 0 to 60 C
Wetted materials Body New PFA, diaphragm PTFE; actuator PVDF
Source SMC Korea catalog LVQ Series (SMCKR_LVQ.pdf), p. 69-78 (PDF p. 8-17)
LVQ20-V03 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V03R Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V03-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V03R-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V03-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V03R-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V03-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V03R-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V03-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V03R-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V03-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V03R-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V03-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V03R-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V03-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V03R-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V03-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V03R-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V03-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V03R-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V03-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V03-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V03R-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V03-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V03R-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V03-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V03R-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V03-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V03R-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V03-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V03R-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V03-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V03R-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V03-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V03R-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V03-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V03R-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V03-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V03R-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V03-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V03R-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V03-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V03R-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V03-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V03R-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V03-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V03R-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V03-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V03-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V03R-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V03-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V03R-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V03-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V03R-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V03-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V03R-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V03-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V03R-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V03-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V03R-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V03-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V03R-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V03-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V03 Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V03R Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V03-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V03R-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V03-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V03R-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V03-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V03R-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V03 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V03R Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V03-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V03R-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V03-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V03R-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V03-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V03R-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V03-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V03R-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V03-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V03R-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V03-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V03R-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V04 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V04R Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V04-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V04R-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V04-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V04R-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V04-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V04R-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V04-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V04R-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V04-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V04R-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V04-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V04R-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V04-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V04R-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V04-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V04R-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V04-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V04R-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V04-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V04-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V04R-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V04-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V04R-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V04-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V04R-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V04-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V04R-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V04-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V04R-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V04-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V04R-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V04-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V04R-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V04-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V04R-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V04-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V04R-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V04-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V04R-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V04-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V04R-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V04-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V04R-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V04-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V04R-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V04-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V04-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V04R-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V04-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V04R-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V04-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V04R-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V04-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V04R-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V04-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V04R-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V04-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V04R-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V04-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V04R-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V04-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V04 Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V04R Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V04-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V04R-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V04-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V04R-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V04-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V04R-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V04 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V04R Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V04-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V04R-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V04-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V04R-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V04-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V04R-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V04-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V04R-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V04-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V04R-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V04-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V04R-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V06 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V06R Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V06-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V06R-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V06-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V06R-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V06-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V06R-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V06-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V06R-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V06-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V06R-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V06-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V06R-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V06-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V06R-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V06-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V06R-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V06-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V06R-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V06-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V06-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V06R-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V06-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V06R-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V06-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V06R-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V06-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V06R-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V06-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V06R-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V06-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V06R-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V06-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V06R-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V06-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V06R-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V06-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V06R-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V06-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V06R-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V06-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V06R-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V06-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V06R-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V06-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V06R-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V06-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V06-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V06R-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V06-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V06R-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V06-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V06R-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V06-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V06R-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V06-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V06R-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V06-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V06R-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V06-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V06R-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V06-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V06 Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V06R Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V06-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V06R-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V06-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V06R-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V06-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V06R-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V06 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V06R Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V06-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V06R-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V06-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V06R-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V06-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V06R-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V06-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V06R-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V06-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V06R-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V06-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V06R-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V05 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V05R Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V05-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V05R-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V05-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V05R-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V05-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V05R-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V05-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V05R-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V05-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V05R-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V05-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V05R-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V05-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V05R-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V05-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V05R-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V05-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V05R-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V05-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V05-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V05R-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V05-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V05R-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V05-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V05R-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V05-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V05R-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V05-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V05R-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V05-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V05R-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V05-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V05R-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V05-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V05R-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V05-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V05R-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V05-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V05R-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V05-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V05R-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V05-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V05R-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V05-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V05R-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V05-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V05-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V05R-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V05-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V05R-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V05-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V05R-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V05-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V05R-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V05-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V05R-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V05-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V05R-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V05-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V05R-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V05-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V05 Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V05R Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V05-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V05R-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V05-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V05R-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V05-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V05R-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V05 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V05R Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V05-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V05R-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V05-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V05R-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V05-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V05R-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V05-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V05R-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V05-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V05R-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V05-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V05R-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V07 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V07R Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V07-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V07R-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V07-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V07R-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V07-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V07R-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V07-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V07R-1 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V07-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V07R-1-J Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V07-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V07R-1-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V07-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V07R-1-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V07-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V07R-2 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V07-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V07R-2-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V07-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-2-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V07-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V07R-3 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V07-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V07R-3-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V07-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-3-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V07R-4 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V07-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V07R-4-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V07-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V07R-4-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V07-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V07R-5 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V07-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V07R-5-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V07-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V07R-5-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V07-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V07R-6 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V07-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V07R-6-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V07-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V07R-6-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V07-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V07R-7 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V07-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V07R-7-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V07-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-7-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V07-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V07R-8 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V07-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V07R-8-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V07-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-8-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V07R-9 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V07-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V07R-9-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V07-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V07R-9-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V07-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V07R-24 Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V07-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V07R-24-K Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V07-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-24-N Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V07 Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V07R Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V07-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V07R-J Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V07-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V07R-K Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V07-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V07R-N Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V07 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V07R Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V07-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V07R-J Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V07-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V07R-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V07-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V07R-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V07-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V07R-2 Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V07-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V07R-2-K Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V07-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V07R-2-N Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V06 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V06R Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V06-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V06R-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V06-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V06R-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V06-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V06R-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V06-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V06R-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V06-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V06R-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V06-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V06R-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V06-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V06R-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V06-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V06R-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V06-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V06R-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V06-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V06-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V06R-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V06-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V06R-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V06-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V06R-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V06-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V06R-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V06-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V06R-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V06-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V06R-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V06-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V06R-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V06-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V06R-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V06-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V06R-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V06-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V06R-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V06-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V06R-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V06-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V06R-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V06-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V06R-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V06-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V06-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V06R-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V06-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V06R-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V06-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V06R-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V06-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V06R-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V06-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V06R-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V06-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V06R-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V06-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V06R-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V06-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V06 Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V06R Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V06-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V06R-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V06-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V06R-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V06-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V06R-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V06 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V06R Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V06-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V06R-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V06-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V06R-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V06-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V06R-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V06-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V06R-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V06-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V06R-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V06-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V06R-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V08 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V08R Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V08-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V08R-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V08-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V08R-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V08-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V08R-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V08-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V08R-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V08-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V08R-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V08-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V08R-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V08-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V08R-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V08-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V08R-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V08-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V08R-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V08-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V08-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V08R-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V08-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V08R-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V08-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V08R-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V08-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V08R-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V08-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V08R-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V08-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V08R-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V08-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V08R-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V08-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V08R-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V08-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V08R-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V08-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V08R-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V08-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V08R-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V08-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V08R-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V08-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V08R-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V08-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V08-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V08R-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V08-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V08R-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V08-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V08R-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V08-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V08R-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V08-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V08R-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V08-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V08R-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V08-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V08R-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V08-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V08 Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V08R Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V08-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V08R-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V08-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V08R-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V08-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V08R-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V08 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V08R Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V08-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V08R-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V08-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V08R-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V08-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V08R-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V08-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V08R-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V08-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V08R-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V08-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V08R-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V10 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V10R Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V10-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V10R-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V10-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V10R-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V10-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V10R-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V10-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V10R-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V10-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V10R-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V10-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V10R-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V10-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V10R-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V10-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V10R-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V10-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V10R-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V10-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V10-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V10R-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V10-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V10R-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V10-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V10R-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V10-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V10R-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V10-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V10R-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V10-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V10R-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V10-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V10R-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V10-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V10R-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V10-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V10R-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V10-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V10R-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V10-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V10R-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V10-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V10R-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V10-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V10R-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V10-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V10-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V10R-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V10-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V10R-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V10-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V10R-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V10-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V10R-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V10-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V10R-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V10-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V10R-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V10-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V10R-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V10-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V10 Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V10R Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V10-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V10R-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V10-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V10R-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V10-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V10R-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V10 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V10R Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V10-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V10R-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V10-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V10R-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V10-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V10R-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V10-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V10R-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V10-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V10R-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V10-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V10R-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V07 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V07R Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V07-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V07R-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V07-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V07R-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V07-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V07R-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V07-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V07R-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V07-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V07R-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V07-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V07R-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V07-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V07R-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V07-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V07R-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V07-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V07R-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V07-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V07-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V07R-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V07-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V07R-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V07-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V07R-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V07-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V07R-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V07-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V07R-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V07-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V07R-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V07-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V07R-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V07-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V07R-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V07-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V07R-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V07-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V07R-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V07-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V07R-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V07-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V07R-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V07-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V07R-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V07-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V07-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V07R-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V07-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V07R-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V07-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V07R-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V07-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V07R-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V07-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V07R-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V07-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V07R-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V07-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V07R-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V07-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V07 Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V07R Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V07-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V07R-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V07-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V07R-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V07-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V07R-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V07 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V07R Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V07-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V07R-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V07-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V07R-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V07-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V07R-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V07-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V07R-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V07-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V07R-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V07-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V07R-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V11 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V11R Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V11-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V11R-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V11-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V11R-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V11-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V11R-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V11-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V11R-1 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V11-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V11R-1-J Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V11-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V11R-1-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V11-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V11R-1-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V11-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V11R-2 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V11-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V11R-2-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V11-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-2-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V11-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V11R-3 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V11-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V11R-3-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V11-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-3-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V11R-4 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V11-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V11R-4-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V11-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V11R-4-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V11-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V11R-5 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V11-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V11R-5-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V11-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V11R-5-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V11-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V11R-6 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V11-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V11R-6-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V11-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V11R-6-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V11-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V11R-7 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V11-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V11R-7-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V11-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-7-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V11-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V11R-8 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V11-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V11R-8-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V11-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-8-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V11R-9 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V11-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V11R-9-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V11-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V11R-9-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V11-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V11R-24 Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V11-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V11R-24-K Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V11-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-24-N Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V11 Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V11R Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V11-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V11R-J Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V11-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V11R-K Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V11-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V11R-N Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V11 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V11R Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V11-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V11R-J Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V11-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V11R-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V11-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V11R-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V11-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V11R-2 Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V11-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V11R-2-K Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V11-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V11R-2-N Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
Chemical ValvesSMC
920 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC LVQ Air Operated Chemical Valve (LQ1 Fitting, Class 2-3)

Brand SMC·Chemical Valves

Available part numbers (920)

LVQ20-V03, LVQ20-V03R, LVQ20-V03-J, LVQ20-V03R-J, LVQ20-V03-K, LVQ20-V03R-K, LVQ20-V03-N, LVQ20-V03R-N, LVQ20-V03-1, LVQ20-V03R-1 + 910 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
LVQ20-V03Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V03RBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V03-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V03R-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V03-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V03R-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V03-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V03R-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V03-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V03R-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V03-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V03R-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V03-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V03R-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V03-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V03R-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V03-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V03R-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V03-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V03R-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V03-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V03-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V03R-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V03-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V03R-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V03-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V03R-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V03-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V03R-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V03-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V03R-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V03-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V03R-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V03-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V03R-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V03-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V03R-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V03-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V03R-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V03-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V03R-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V03-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V03R-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V03-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V03R-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V03-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V03R-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V03-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V03-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V03R-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V03-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V03R-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V03-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V03-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V03R-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V03-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V03R-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V03-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V03R-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V03-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V03R-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V03-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V03R-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V03-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V03R-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V03Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V03RBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V03-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V03R-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V03-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V03R-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V03-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V03R-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V03Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V03RBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V03-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V03R-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V03-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V03R-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V03-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V03R-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V03-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V03R-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V03-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V03R-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V03-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V03R-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3x2 mm / 1/8 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V04Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V04RBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V04-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V04R-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V04-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V04R-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V04-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V04R-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V04-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V04R-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V04-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V04R-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V04-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V04R-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V04-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V04R-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V04-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V04R-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V04-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V04R-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V04-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V04-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V04R-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V04-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V04R-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V04-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V04R-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V04-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V04R-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V04-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V04R-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V04-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V04R-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V04-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V04R-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V04-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V04R-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V04-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V04R-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V04-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V04R-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V04-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V04R-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V04-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V04R-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V04-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V04R-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V04-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V04-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V04R-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V04-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V04R-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V04-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V04-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V04R-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V04-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V04R-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V04-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V04R-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V04-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V04R-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V04-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V04R-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V04-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V04R-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V04Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V04RBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V04-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V04R-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V04-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V04R-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V04-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V04R-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V04Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V04RBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V04-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V04R-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V04-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V04R-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V04-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V04R-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V04-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V04R-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V04-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V04R-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V04-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V04R-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 4x3 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V06Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V06RBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V06-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V06R-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V06-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V06R-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V06-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V06R-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V06-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V06R-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V06-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V06R-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V06-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V06R-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V06-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V06R-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V06-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V06R-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V06-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V06R-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V06-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V06-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V06R-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V06-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V06R-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V06-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V06R-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V06-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V06R-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V06-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V06R-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V06-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V06R-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V06-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V06R-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V06-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V06R-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V06-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V06R-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V06-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V06R-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V06-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V06R-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V06-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V06R-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V06-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V06R-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V06-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V06-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V06R-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V06-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V06R-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V06-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V06-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V06R-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V06-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V06R-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V06-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V06R-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V06-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V06R-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V06-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V06R-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V06-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V06R-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V06Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V06RBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V06-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V06R-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V06-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V06R-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V06-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V06R-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V06Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V06RBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V06-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V06R-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V06-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V06R-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V06-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V06R-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V06-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V06R-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V06-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V06R-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V06-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V06R-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 6x4 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V05Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V05RBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V05-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V05R-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V05-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V05R-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V05-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V05R-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V05-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V05R-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V05-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V05R-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V05-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V05R-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V05-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V05R-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V05-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V05R-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V05-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V05R-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V05-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V05-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V05R-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V05-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V05R-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V05-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V05R-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V05-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V05R-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V05-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V05R-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V05-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V05R-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V05-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V05R-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V05-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V05R-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V05-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V05R-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V05-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V05R-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V05-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V05R-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V05-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V05R-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V05-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V05R-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V05-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V05-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V05R-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V05-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V05R-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V05-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V05-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V05R-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V05-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V05R-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V05-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V05R-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V05-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V05R-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V05-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V05R-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V05-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V05R-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V05Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V05RBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V05-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V05R-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V05-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V05R-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V05-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V05R-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V05Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V05RBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V05-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V05R-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V05-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V05R-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V05-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V05R-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V05-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V05R-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V05-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V05R-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V05-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V05R-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 3/16 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V07Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ20-V07RBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ20-V07-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V07R-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ20-V07-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ20-V07R-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ20-V07-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ20-V07R-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ20-V07-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ20-V07R-1Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ20-V07-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V07R-1-JBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ20-V07-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ20-V07R-1-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ20-V07-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V07R-1-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ20-V07-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ20-V07R-2Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ20-V07-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ20-V07R-2-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ20-V07-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-2-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ20-V07-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V07R-3Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ20-V07-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V07R-3-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ20-V07-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-3-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ20-V07R-4Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ20-V07-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ20-V07R-4-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ20-V07-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V07R-4-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ20-V07-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V07R-5Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ20-V07-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V07R-5-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ20-V07-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V07R-5-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ20-V07-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V07R-6Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ20-V07-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V07R-6-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ20-V07-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V07R-6-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ20-V07-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ20-V07R-7Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ20-V07-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ20-V07R-7-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ20-V07-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-7-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ20-V07-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V07R-8Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ20-V07-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V07R-8-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ20-V07-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-8-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ20-V07-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ20-V07R-9Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ20-V07-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ20-V07R-9-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ20-V07-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V07R-9-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ20-V07-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ20-V07R-24Body class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ20-V07-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V07R-24-KBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ20-V07-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ20-V07R-24-NBody class: 2 (ø4 orifice) | Valve type: N.C. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ21-V07Body class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ21-V07RBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ21-V07-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V07R-JBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ21-V07-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ21-V07R-KBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ21-V07-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ21-V07R-NBody class: 2 (ø4 orifice) | Valve type: N.O. | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V07Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ22-V07RBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ22-V07-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V07R-JBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ22-V07-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ22-V07R-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ22-V07-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ22-V07R-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ22-V07-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ22-V07R-2Body class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ22-V07-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ22-V07R-2-KBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ22-V07-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ22-V07R-2-NBody class: 2 (ø4 orifice) | Valve type: Double acting | Tube size: 1/4 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V06Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V06RBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V06-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V06R-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V06-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V06R-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V06-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V06R-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V06-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V06R-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V06-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V06R-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V06-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V06R-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V06-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V06R-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V06-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V06R-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V06-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V06R-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V06-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V06-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V06R-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V06-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V06R-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V06-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V06R-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V06-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V06R-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V06-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V06R-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V06-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V06R-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V06-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V06R-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V06-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V06R-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V06-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V06R-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V06-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V06R-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V06-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V06R-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V06-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V06R-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V06-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V06R-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V06-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V06-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V06R-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V06-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V06R-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V06-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V06-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V06R-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V06-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V06R-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V06-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V06R-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V06-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V06R-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V06-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V06R-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V06-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V06R-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V06Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V06RBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V06-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V06R-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V06-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V06R-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V06-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V06R-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V06Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V06RBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V06-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V06R-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V06-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V06R-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V06-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V06R-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V06-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V06R-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V06-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V06R-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V06-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V06R-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 6x4 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V08Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V08RBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V08-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V08R-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V08-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V08R-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V08-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V08R-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V08-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V08R-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V08-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V08R-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V08-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V08R-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V08-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V08R-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V08-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V08R-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V08-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V08R-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V08-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V08-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V08R-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V08-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V08R-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V08-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V08R-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V08-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V08R-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V08-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V08R-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V08-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V08R-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V08-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V08R-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V08-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V08R-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V08-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V08R-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V08-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V08R-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V08-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V08R-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V08-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V08R-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V08-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V08R-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V08-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V08-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V08R-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V08-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V08R-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V08-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V08-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V08R-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V08-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V08R-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V08-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V08R-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V08-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V08R-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V08-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V08R-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V08-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V08R-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V08Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V08RBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V08-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V08R-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V08-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V08R-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V08-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V08R-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V08Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V08RBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V08-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V08R-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V08-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V08R-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V08-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V08R-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V08-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V08R-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V08-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V08R-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V08-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V08R-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 8x6 mm (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V10Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V10RBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V10-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V10R-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V10-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V10R-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V10-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V10R-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V10-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V10R-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V10-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V10R-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V10-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V10R-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V10-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V10R-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V10-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V10R-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V10-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V10R-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V10-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V10-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V10R-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V10-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V10R-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V10-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V10R-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V10-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V10R-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V10-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V10R-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V10-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V10R-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V10-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V10R-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V10-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V10R-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V10-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V10R-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V10-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V10R-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V10-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V10R-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V10-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V10R-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V10-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V10R-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V10-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V10-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V10R-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V10-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V10R-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V10-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V10-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V10R-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V10-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V10R-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V10-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V10R-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V10-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V10R-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V10-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V10R-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V10-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V10R-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V10Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V10RBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V10-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V10R-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V10-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V10R-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V10-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V10R-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V10Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V10RBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V10-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V10R-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V10-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V10R-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V10-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V10R-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V10-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V10R-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V10-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V10R-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V10-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V10R-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 10x8 mm (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V07Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V07RBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V07-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V07R-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V07-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V07R-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V07-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V07R-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V07-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V07R-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V07-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V07R-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V07-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V07R-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V07-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V07R-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V07-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V07R-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V07-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V07R-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V07-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V07-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V07R-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V07-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V07R-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V07-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V07R-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V07-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V07R-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V07-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V07R-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V07-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V07R-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V07-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V07R-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V07-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V07R-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V07-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V07R-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V07-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V07R-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V07-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V07R-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V07-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V07R-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V07-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V07R-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V07-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V07-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V07R-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V07-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V07R-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V07-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V07-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V07R-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V07-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V07R-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V07-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V07R-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V07-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V07R-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V07-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V07R-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V07-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V07R-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V07Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V07RBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V07-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V07R-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V07-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V07R-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V07-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V07R-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V07Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V07RBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V07-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V07R-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V07-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V07R-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V07-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V07R-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V07-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V07R-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V07-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V07R-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V07-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V07R-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 1/4 in (reducer) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V11Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ30-V11RBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ30-V11-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V11R-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ30-V11-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ30-V11R-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ30-V11-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ30-V11R-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ30-V11-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM
LVQ30-V11R-1Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM
LVQ30-V11-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V11R-1-JBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FKM, high temp. 170 C
LVQ30-V11-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: FFKM
LVQ30-V11R-1-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: FFKM
LVQ30-V11-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V11R-1-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adjustment | Buffer: EPDM (ammonia)
LVQ30-V11-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ30-V11R-2Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ30-V11-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ30-V11R-2-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ30-V11-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-2-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)
LVQ30-V11-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V11R-3Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FKM
LVQ30-V11-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V11R-3-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: FFKM
LVQ30-V11-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-3-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FKM
LVQ30-V11R-4Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FKM
LVQ30-V11-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: FFKM
LVQ30-V11R-4-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: FFKM
LVQ30-V11-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V11R-4-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator | Buffer: EPDM (ammonia)
LVQ30-V11-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V11R-5Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FKM
LVQ30-V11-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V11R-5-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: FFKM
LVQ30-V11-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V11R-5-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High back pressure 0.42 MPa | Buffer: EPDM (ammonia)
LVQ30-V11-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V11R-6Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FKM
LVQ30-V11-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V11R-6-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: FFKM
LVQ30-V11-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V11R-6-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. | Buffer: EPDM (ammonia)
LVQ30-V11-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FKM
LVQ30-V11R-7Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FKM
LVQ30-V11-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: FFKM
LVQ30-V11R-7-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: FFKM
LVQ30-V11-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-7-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + bypass | Buffer: EPDM (ammonia)
LVQ30-V11-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V11R-8Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FKM
LVQ30-V11-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V11R-8-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: FFKM
LVQ30-V11-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-8-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + flow adj. + bypass | Buffer: EPDM (ammonia)
LVQ30-V11-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FKM
LVQ30-V11R-9Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FKM
LVQ30-V11-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: FFKM
LVQ30-V11R-9-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: FFKM
LVQ30-V11-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V11R-9-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: High BP + indicator | Buffer: EPDM (ammonia)
LVQ30-V11-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FKM
LVQ30-V11R-24Body class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FKM
LVQ30-V11-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V11R-24-KBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: FFKM
LVQ30-V11-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ30-V11R-24-NBody class: 3 (ø8 orifice) | Valve type: N.C. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Indicator + bypass | Buffer: EPDM (ammonia)
LVQ31-V11Body class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ31-V11RBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ31-V11-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V11R-JBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ31-V11-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ31-V11R-KBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ31-V11-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ31-V11R-NBody class: 3 (ø8 orifice) | Valve type: N.O. | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V11Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM
LVQ32-V11RBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM
LVQ32-V11-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V11R-JBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FKM, high temp. 170 C
LVQ32-V11-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: FFKM
LVQ32-V11R-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: FFKM
LVQ32-V11-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: None | Buffer: EPDM (ammonia)
LVQ32-V11R-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: None | Buffer: EPDM (ammonia)
LVQ32-V11-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FKM
LVQ32-V11R-2Body class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FKM
LVQ32-V11-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: FFKM
LVQ32-V11R-2-KBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: FFKM
LVQ32-V11-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Integrated fitting, 1/8 in tube | Option: Bypass | Buffer: EPDM (ammonia)
LVQ32-V11R-2-NBody class: 3 (ø8 orifice) | Valve type: Double acting | Tube size: 3/8 in (std) | Pilot port: Rc1/8 thread | Option: Bypass | Buffer: EPDM (ammonia)

Need a different model, or a part not listed here? Send us your parts list →