Skip to product information
1 of 1

SMC VP346E/546E/746E/946E Residual Pressure Release Valve (Modular)

SMC VP346E/546E/746E/946E Residual Pressure Release Valve (Modular)

SMC VP346E/546E/746E/946E series 3-port residual pressure release solenoid valve, modular type for direct connection to AC-D F.R.L. combinations, with optional built-in soft start-up.

Key features

  • Connects directly to AC20-D to AC60-D modular F.R.L. combinations, saving space and piping work
  • Soft start-up function can be built in (S): slow supply at start-up then full flow
  • Low power consumption 0.35 W (without lamp); check valve in pilot passage counters pilot pressure drop
  • Electrical entry: DIN terminal (D/DO/DZ), EN175301-803C DIN terminal (Y/YO/YZ) or M12 connector (KOZ)
  • High-pressure 1.0 MPa type (K) for VP546E/746E; manual operation types A (VP500/700 only) and E
  • No connection thread on valve body: order piping adapter (E-D) and bracket spacer (Y-T-D) separately

Specifications

Fluid Air
Switching N.C.
Internal pilot operating pressure 0.2 to 0.7 MPa (K type 0.2 to 1.0 MPa)
Ambient and fluid temperature -10 to 50°C (no freezing)
Rated voltage DC24V
Power consumption 0.35 W (with lamp 0.45 W; M12 0.4 W)
Enclosure IP65
Max. operating frequency 5 Hz (VP946E 1 Hz), except soft start-up type
Flow rate C 1-2 [dm³/(s·bar)] VP346E 4.3, VP546E 8.8, VP746E 13.8
Pilot exhaust Individual exhaust
Source SMC Korea catalog VP346E/546E/746E/946E (SMCKR_VP546E-746E.pdf), p. 1095-1102 (PDF p. 1-3)
VP346E-5D1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5D1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5D1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5D1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5DE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5DE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5DE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5DE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5DZ1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5DZ1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5DZ1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5DZ1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5DZE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5DZE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5DZE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5DZE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5DO1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5DO1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5DO1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5DO1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5DOE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5DOE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5DOE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5DOE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5Y1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5Y1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5Y1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5Y1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5YE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5YE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5YE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5YE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5YZ1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5YZ1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5YZ1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5YZ1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5YZE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5YZE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5YZE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5YZE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5YO1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5YO1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5YO1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5YO1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5YOE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5YOE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5YOE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5YOE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5KOZ1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5KOZ1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5KOZ1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5KOZ1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5KOZE1 Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5KOZE1-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5KOZE1-R Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5KOZE1-R-S Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5D1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5D1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5D1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5D1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5DA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DZ1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5DZ1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5DZ1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5DZ1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5DZA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DZA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DZA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DZA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DZE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DZE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DZE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DZE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DO1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5DO1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5DO1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5DO1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5DOA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DOA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DOA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DOA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DOE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DOE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DOE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DOE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5Y1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5Y1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5Y1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5Y1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5YA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YZ1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5YZ1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5YZ1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5YZ1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5YZA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YZA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YZA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YZA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YZE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YZE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YZE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YZE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YO1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5YO1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5YO1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5YO1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5YOA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YOA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YOA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YOA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YOE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YOE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YOE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YOE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5KOZ1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5KOZ1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5KOZ1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5KOZ1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5KOZA1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5KOZA1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5KOZA1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5KOZA1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5KOZE1 Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5KOZE1-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5KOZE1-R Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5KOZE1-R-S Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5D1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5D1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5D1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5D1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DZ1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5DZ1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DZ1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5DZ1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DZA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DZA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DZA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DZA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DZE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DZE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DZE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DZE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DO1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5DO1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DO1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5DO1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DOA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DOA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DOA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DOA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DOE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DOE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DOE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DOE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5Y1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5Y1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5Y1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5Y1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YZ1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5YZ1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YZ1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5YZ1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YZA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YZA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YZA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YZA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YZE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YZE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YZE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YZE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YO1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5YO1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YO1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5YO1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YOA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YOA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YOA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YOA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YOE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YOE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YOE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YOE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5KOZ1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5KOZ1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5KOZ1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5KOZ1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5KOZA1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5KOZA1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5KOZA1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5KOZA1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5KOZE1 Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5KOZE1-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5KOZE1-R Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5KOZE1-R-S Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5D1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5D1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5D1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5D1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5DA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DZ1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5DZ1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5DZ1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5DZ1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5DZA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DZA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DZA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DZA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DZE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DZE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DZE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DZE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DO1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5DO1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5DO1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5DO1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5DOA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DOA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DOA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DOA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DOE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DOE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DOE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DOE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5Y1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5Y1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5Y1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5Y1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5YA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YZ1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5YZ1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5YZ1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5YZ1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5YZA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YZA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YZA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YZA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YZE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YZE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YZE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YZE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YO1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5YO1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5YO1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5YO1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5YOA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YOA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YOA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YOA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YOE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YOE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YOE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YOE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5KOZ1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5KOZ1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5KOZ1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5KOZ1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5KOZA1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5KOZA1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5KOZA1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5KOZA1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5KOZE1 Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5KOZE1-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5KOZE1-R Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5KOZE1-R-S Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5D1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5D1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5D1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5D1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DZ1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5DZ1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DZ1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5DZ1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DZA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DZA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DZA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DZA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DZE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DZE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DZE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DZE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DO1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5DO1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DO1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5DO1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DOA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DOA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DOA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DOA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DOE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DOE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DOE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DOE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5Y1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5Y1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5Y1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5Y1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YZ1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5YZ1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YZ1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5YZ1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YZA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YZA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YZA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YZA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YZE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YZE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YZE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YZE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YO1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5YO1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YO1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5YO1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YOA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YOA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YOA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YOA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YOE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YOE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YOE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YOE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5KOZ1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5KOZ1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5KOZ1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5KOZ1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5KOZA1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5KOZA1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5KOZA1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5KOZA1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5KOZE1 Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5KOZE1-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5KOZE1-R Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5KOZE1-R-S Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5D1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5D1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5D1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5D1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5DE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5DE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5DE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5DE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5DZ1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5DZ1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5DZ1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5DZ1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5DZE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5DZE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5DZE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5DZE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5DO1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5DO1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5DO1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5DO1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5DOE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5DOE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5DOE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5DOE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5Y1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5Y1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5Y1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5Y1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5YE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5YE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5YE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5YE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5YZ1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5YZ1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5YZ1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5YZ1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5YZE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5YZE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5YZE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5YZE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5YO1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5YO1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5YO1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5YO1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5YOE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5YOE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5YOE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5YOE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5KOZ1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5KOZ1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5KOZ1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5KOZ1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5KOZE1 Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5KOZE1-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5KOZE1-R Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5KOZE1-R-S Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
3-Port Solenoid ValvesSMC
448 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC VP346E/546E/746E/946E Residual Pressure Release Valve (Modular)

Brand SMC·3-Port Solenoid Valves

Available part numbers (448)

VP346E-5D1, VP346E-5D1-S, VP346E-5D1-R, VP346E-5D1-R-S, VP346E-5DE1, VP346E-5DE1-S, VP346E-5DE1-R, VP346E-5DE1-R-S, VP346E-5DZ1, VP346E-5DZ1-S + 438 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
VP346E-5D1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5D1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5D1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5D1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5DE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5DE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5DE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5DE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5DZ1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5DZ1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5DZ1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5DZ1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5DZE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5DZE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5DZE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5DZE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5DO1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5DO1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5DO1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5DO1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5DOE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5DOE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5DOE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5DOE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5Y1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5Y1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5Y1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5Y1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5YE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5YE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5YE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5YE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5YZ1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5YZ1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5YZ1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5YZ1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5YZE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5YZE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5YZE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5YZE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5YO1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5YO1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5YO1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5YO1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5YOE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5YOE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5YOE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5YOE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP346E-5KOZ1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP346E-5KOZ1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP346E-5KOZ1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP346E-5KOZ1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP346E-5KOZE1Series: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP346E-5KOZE1-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP346E-5KOZE1-RSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP346E-5KOZE1-R-SSeries: VP300 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5D1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5D1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5D1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5D1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5DA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DZ1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5DZ1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5DZ1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5DZ1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5DZA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DZA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DZA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DZA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DZE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DZE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DZE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DZE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DO1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5DO1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5DO1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5DO1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5DOA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DOA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DOA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DOA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5DOE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5DOE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5DOE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5DOE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5Y1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5Y1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5Y1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5Y1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5YA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YZ1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5YZ1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5YZ1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5YZ1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5YZA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YZA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YZA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YZA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YZE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YZE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YZE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YZE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YO1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5YO1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5YO1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5YO1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5YOA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YOA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YOA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YOA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5YOE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5YOE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5YOE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5YOE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5KOZ1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546E-5KOZ1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546E-5KOZ1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546E-5KOZ1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546E-5KOZA1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5KOZA1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5KOZA1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5KOZA1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546E-5KOZE1Series: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546E-5KOZE1-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546E-5KOZE1-RSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546E-5KOZE1-R-SSeries: VP500 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5D1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5D1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5D1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5D1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DZ1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5DZ1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DZ1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5DZ1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DZA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DZA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DZA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DZA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DZE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DZE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DZE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DZE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DO1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5DO1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DO1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5DO1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DOA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DOA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DOA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DOA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5DOE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5DOE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5DOE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5DOE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5Y1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5Y1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5Y1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5Y1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YZ1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5YZ1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YZ1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5YZ1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YZA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YZA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YZA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YZA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YZE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YZE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YZE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YZE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YO1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5YO1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YO1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5YO1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YOA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YOA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YOA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YOA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5YOE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5YOE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5YOE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5YOE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5KOZ1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP546EK-5KOZ1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP546EK-5KOZ1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP546EK-5KOZ1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP546EK-5KOZA1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5KOZA1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5KOZA1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5KOZA1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP546EK-5KOZE1Series: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP546EK-5KOZE1-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP546EK-5KOZE1-RSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP546EK-5KOZE1-R-SSeries: VP500 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5D1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5D1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5D1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5D1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5DA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DZ1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5DZ1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5DZ1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5DZ1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5DZA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DZA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DZA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DZA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DZE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DZE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DZE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DZE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DO1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5DO1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5DO1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5DO1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5DOA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DOA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DOA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DOA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5DOE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5DOE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5DOE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5DOE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5Y1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5Y1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5Y1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5Y1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5YA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YZ1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5YZ1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5YZ1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5YZ1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5YZA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YZA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YZA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YZA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YZE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YZE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YZE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YZE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YO1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5YO1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5YO1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5YO1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5YOA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YOA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YOA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YOA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5YOE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5YOE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5YOE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5YOE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5KOZ1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746E-5KOZ1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746E-5KOZ1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746E-5KOZ1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746E-5KOZA1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5KOZA1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5KOZA1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5KOZA1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746E-5KOZE1Series: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746E-5KOZE1-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746E-5KOZE1-RSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746E-5KOZE1-R-SSeries: VP700 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5D1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5D1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5D1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5D1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DZ1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5DZ1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DZ1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5DZ1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DZA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DZA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DZA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DZA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DZE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DZE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DZE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DZE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DO1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5DO1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DO1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5DO1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DOA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DOA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DOA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DOA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5DOE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5DOE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5DOE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5DOE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5Y1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5Y1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5Y1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5Y1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YZ1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5YZ1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YZ1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5YZ1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YZA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YZA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YZA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YZA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YZE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YZE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YZE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YZE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YO1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5YO1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YO1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5YO1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YOA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YOA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YOA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YOA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5YOE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5YOE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5YOE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5YOE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5KOZ1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP746EK-5KOZ1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP746EK-5KOZ1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP746EK-5KOZ1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP746EK-5KOZA1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5KOZA1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5KOZA1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5KOZA1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push, manual operation | Flow: Right to left | Soft start-up: Built-in
VP746EK-5KOZE1Series: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP746EK-5KOZE1-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP746EK-5KOZE1-RSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP746EK-5KOZE1-R-SSeries: VP700 | Pressure: High 1.0 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5D1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5D1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5D1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5D1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5DE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5DE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5DE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5DE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal with connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5DZ1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5DZ1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5DZ1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5DZ1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5DZE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5DZE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5DZE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5DZE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal, connector, lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5DO1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5DO1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5DO1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5DO1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5DOE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5DOE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5DOE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5DOE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN terminal without connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5Y1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5Y1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5Y1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5Y1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5YE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5YE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5YE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5YE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5YZ1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5YZ1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5YZ1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5YZ1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5YZE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5YZE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5YZE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5YZE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, conn., lamp/surge | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5YO1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5YO1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5YO1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5YO1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5YOE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5YOE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5YOE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5YOE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: DIN EN175301-803C, no connector | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in
VP946E-5KOZ1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: None
VP946E-5KOZ1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Left to right | Soft start-up: Built-in
VP946E-5KOZ1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: None
VP946E-5KOZ1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Non-locking push | Flow: Right to left | Soft start-up: Built-in
VP946E-5KOZE1Series: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: None
VP946E-5KOZE1-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Left to right | Soft start-up: Built-in
VP946E-5KOZE1-RSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: None
VP946E-5KOZE1-R-SSeries: VP900 | Pressure: Standard 0.7 MPa | Electrical entry: M12 connector, no cable | Manual: Push-turn locking, manual operation | Flow: Right to left | Soft start-up: Built-in

Need a different model, or a part not listed here? Send us your parts list →