Skip to product information
1 of 1

SMC XSA High Vacuum 2-Port Solenoid Valve (N.C., Orifice 2-6 mm)

SMC XSA High Vacuum 2-Port Solenoid Valve (N.C., Orifice 2-6 mm)

SMC XSA normally closed high vacuum 2-port solenoid valve for 1x10^-6 Pa(abs), with face seal, compression or Rc female thread connection.

Key features

  • Minimum operating pressure 1x10^-6 Pa(abs) on OUT side; internal leak 1.3x10^-9 Pa m3/s
  • Three valve sizes, orifice 2 to 6 mm; face seal or compression fitting (1/4, 3/8 in) or Rc female thread
  • Up to 25% lower power consumption and 18% lighter than previous models
  • Cleaned, assembled and double-bagged in a Class 100 clean environment
  • Spacer (A) and NPT thread versions available as options, not expanded

Specifications

Valve type Normally closed, direct operated
Fluid Air, inert gas
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa (IN side)
Leakage Internal 1.3x10^-9, external 1.3x10^-11 Pa m3/s
Ambient and fluid temperature 5-60 C
Coil insulation Class B
Power consumption (DC) 4.5 W / 7 W / 10.5 W (size 1/2/3)
Source SMC Korea XSA catalog CAT.KS140-7B (SMCKR_XSA.pdf), p. 3-4
XSA1-12S-1GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-1D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-12S-1DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-12S-1DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-12S-1T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-12S-1TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-12S-1C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-12S-2GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-2D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-12S-2DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-12S-2DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-12S-2T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-12S-2TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-12S-2C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-12S-3GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-3D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-12S-3DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-12S-3DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-12S-3T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-12S-3TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-12S-3C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-12S-4GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-4D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-12S-4DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-12S-4DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-12S-4T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-12S-4TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-12S-4C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-12S-5G2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-12S-5GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-5D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-12S-5DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-12S-5DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-12S-5T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-12S-5TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-12S-5C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-12S-5F2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-12S-6G2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-12S-6GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-6D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-12S-6DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-12S-6DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-12S-6T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-12S-6TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-12S-6C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-12S-6F2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-12S-7GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-7D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-12S-7DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-12S-7DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-12S-7T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-12S-7TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-12S-7C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-12S-8GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-8D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-12S-8DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-12S-8DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-12S-8T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-12S-8TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-12S-8C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-12S-BGS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-BD2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-12S-BDL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-12S-BDO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-12S-BT2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-12S-BTL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-12S-BC2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-12S-JGS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-JD2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-12S-JDL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-12S-JDO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-12S-JT2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-12S-JTL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-12S-JC2 Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-12V-1GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-1D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-12V-1DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-12V-1DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-12V-1T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-12V-1TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-12V-1C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-12V-2GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-2D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-12V-2DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-12V-2DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-12V-2T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-12V-2TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-12V-2C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-12V-3GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-3D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-12V-3DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-12V-3DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-12V-3T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-12V-3TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-12V-3C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-12V-4GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-4D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-12V-4DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-12V-4DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-12V-4T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-12V-4TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-12V-4C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-12V-5G2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-12V-5GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-5D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-12V-5DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-12V-5DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-12V-5T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-12V-5TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-12V-5C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-12V-5F2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-12V-6G2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-12V-6GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-6D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-12V-6DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-12V-6DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-12V-6T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-12V-6TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-12V-6C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-12V-6F2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-12V-7GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-7D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-12V-7DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-12V-7DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-12V-7T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-12V-7TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-12V-7C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-12V-8GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-8D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-12V-8DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-12V-8DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-12V-8T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-12V-8TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-12V-8C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-12V-BGS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-BD2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-12V-BDL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-12V-BDO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-12V-BT2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-12V-BTL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-12V-BC2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-12V-JGS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-JD2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-12V-JDL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-12V-JDO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-12V-JT2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-12V-JTL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-12V-JC2 Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-22S-1GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-1D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-22S-1DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-22S-1DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-22S-1T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-22S-1TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-22S-1C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-22S-2GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-2D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-22S-2DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-22S-2DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-22S-2T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-22S-2TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-22S-2C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-22S-3GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-3D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-22S-3DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-22S-3DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-22S-3T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-22S-3TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-22S-3C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-22S-4GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-4D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-22S-4DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-22S-4DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-22S-4T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-22S-4TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-22S-4C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-22S-5G2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-22S-5GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-5D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-22S-5DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-22S-5DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-22S-5T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-22S-5TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-22S-5C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-22S-5F2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-22S-6G2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-22S-6GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-6D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-22S-6DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-22S-6DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-22S-6T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-22S-6TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-22S-6C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-22S-6F2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-22S-7GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-7D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-22S-7DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-22S-7DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-22S-7T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-22S-7TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-22S-7C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-22S-8GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-8D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-22S-8DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-22S-8DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-22S-8T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-22S-8TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-22S-8C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-22S-BGS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-BD2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-22S-BDL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-22S-BDO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-22S-BT2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-22S-BTL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-22S-BC2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-22S-JGS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-JD2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-22S-JDL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-22S-JDO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-22S-JT2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-22S-JTL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-22S-JC2 Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-22V-1GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-1D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-22V-1DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-22V-1DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-22V-1T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-22V-1TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-22V-1C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-22V-2GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-2D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-22V-2DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-22V-2DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-22V-2T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-22V-2TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-22V-2C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-22V-3GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-3D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-22V-3DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-22V-3DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-22V-3T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-22V-3TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-22V-3C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-22V-4GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-4D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-22V-4DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-22V-4DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-22V-4T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-22V-4TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-22V-4C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-22V-5G2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-22V-5GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-5D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-22V-5DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-22V-5DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-22V-5T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-22V-5TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-22V-5C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-22V-5F2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-22V-6G2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-22V-6GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-6D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-22V-6DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-22V-6DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-22V-6T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-22V-6TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-22V-6C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-22V-6F2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-22V-7GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-7D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-22V-7DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-22V-7DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-22V-7T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-22V-7TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-22V-7C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-22V-8GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-8D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-22V-8DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-22V-8DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-22V-8T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-22V-8TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-22V-8C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-22V-BGS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-BD2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-22V-BDL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-22V-BDO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-22V-BT2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-22V-BTL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-22V-BC2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-22V-JGS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-JD2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-22V-JDL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-22V-JDO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-22V-JT2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-22V-JTL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-22V-JC2 Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-22S-1GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-1D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-22S-1DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-22S-1DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-22S-1T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-22S-1TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-22S-1C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-22S-2GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-2D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-22S-2DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-22S-2DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-22S-2T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-22S-2TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-22S-2C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-22S-3GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-3D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-22S-3DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-22S-3DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-22S-3T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-22S-3TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-22S-3C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-22S-4GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-4D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-22S-4DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-22S-4DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-22S-4T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-22S-4TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-22S-4C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-22S-5G2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-22S-5GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-5D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-22S-5DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-22S-5DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-22S-5T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-22S-5TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-22S-5C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-22S-5F2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-22S-6G2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-22S-6GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-6D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-22S-6DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-22S-6DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-22S-6T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-22S-6TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-22S-6C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-22S-6F2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-22S-7GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-7D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-22S-7DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-22S-7DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-22S-7T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-22S-7TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-22S-7C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-22S-8GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-8D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-22S-8DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-22S-8DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-22S-8T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-22S-8TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-22S-8C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-22S-BGS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-BD2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-22S-BDL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-22S-BDO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-22S-BT2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-22S-BTL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-22S-BC2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-22S-JGS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-JD2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-22S-JDL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-22S-JDO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-22S-JT2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-22S-JTL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-22S-JC2 Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-22V-1GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-1D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-22V-1DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-22V-1DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-22V-1T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-22V-1TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-22V-1C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-22V-2GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-2D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-22V-2DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-22V-2DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-22V-2T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-22V-2TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-22V-2C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-22V-3GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-3D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-22V-3DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-22V-3DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-22V-3T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-22V-3TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-22V-3C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-22V-4GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-4D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-22V-4DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-22V-4DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-22V-4T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-22V-4TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-22V-4C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-22V-5G2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-22V-5GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-5D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-22V-5DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-22V-5DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-22V-5T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-22V-5TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-22V-5C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-22V-5F2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-22V-6G2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-22V-6GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-6D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-22V-6DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-22V-6DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-22V-6T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-22V-6TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-22V-6C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-22V-6F2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-22V-7GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-7D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-22V-7DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-22V-7DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-22V-7T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-22V-7TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-22V-7C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-22V-8GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-8D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-22V-8DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-22V-8DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-22V-8T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-22V-8TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-22V-8C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-22V-BGS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-BD2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-22V-BDL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-22V-BDO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-22V-BT2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-22V-BTL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-22V-BC2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-22V-JGS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-JD2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-22V-JDL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-22V-JDO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-22V-JT2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-22V-JTL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-22V-JC2 Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-32S-1GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-1D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-32S-1DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-32S-1DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-32S-1T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-32S-1TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-32S-1C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-32S-2GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-2D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-32S-2DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-32S-2DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-32S-2T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-32S-2TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-32S-2C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-32S-3GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-3D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-32S-3DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-32S-3DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-32S-3T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-32S-3TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-32S-3C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-32S-4GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-4D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-32S-4DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-32S-4DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-32S-4T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-32S-4TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-32S-4C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-32S-5G2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-32S-5GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-5D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-32S-5DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-32S-5DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-32S-5T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-32S-5TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-32S-5C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-32S-5F2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-32S-6G2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-32S-6GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-6D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-32S-6DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-32S-6DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-32S-6T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-32S-6TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-32S-6C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-32S-6F2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-32S-7GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-7D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-32S-7DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-32S-7DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-32S-7T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-32S-7TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-32S-7C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-32S-8GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-8D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-32S-8DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-32S-8DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-32S-8T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-32S-8TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-32S-8C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-32S-BGS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-BD2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-32S-BDL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-32S-BDO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-32S-BT2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-32S-BTL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-32S-BC2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-32S-JGS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-JD2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-32S-JDL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-32S-JDO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-32S-JT2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-32S-JTL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-32S-JC2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-32V-1GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-1D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-32V-1DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-32V-1DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-32V-1T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-32V-1TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-32V-1C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-32V-2GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-2D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-32V-2DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-32V-2DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-32V-2T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-32V-2TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-32V-2C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-32V-3GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-3D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-32V-3DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-32V-3DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-32V-3T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-32V-3TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-32V-3C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-32V-4GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-4D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-32V-4DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-32V-4DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-32V-4T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-32V-4TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-32V-4C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-32V-5G2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-32V-5GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-5D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-32V-5DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-32V-5DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-32V-5T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-32V-5TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-32V-5C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-32V-5F2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-32V-6G2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-32V-6GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-6D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-32V-6DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-32V-6DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-32V-6T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-32V-6TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-32V-6C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-32V-6F2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-32V-7GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-7D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-32V-7DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-32V-7DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-32V-7T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-32V-7TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-32V-7C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-32V-8GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-8D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-32V-8DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-32V-8DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-32V-8T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-32V-8TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-32V-8C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-32V-BGS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-BD2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-32V-BDL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-32V-BDO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-32V-BT2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-32V-BTL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-32V-BC2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-32V-JGS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-JD2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-32V-JDL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-32V-JDO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-32V-JT2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-32V-JTL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-32V-JC2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-43S-1GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-1D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-43S-1DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-43S-1DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-43S-1T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-43S-1TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-43S-1C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-43S-2GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-2D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-43S-2DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-43S-2DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-43S-2T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-43S-2TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-43S-2C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-43S-3GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-3D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-43S-3DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-43S-3DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-43S-3T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-43S-3TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-43S-3C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-43S-4GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-4D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-43S-4DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-43S-4DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-43S-4T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-43S-4TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-43S-4C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-43S-5G2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-43S-5GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-5D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-43S-5DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-43S-5DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-43S-5T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-43S-5TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-43S-5C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-43S-5F2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-43S-6G2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-43S-6GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-6D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-43S-6DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-43S-6DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-43S-6T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-43S-6TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-43S-6C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-43S-6F2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-43S-7GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-7D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-43S-7DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-43S-7DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-43S-7T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-43S-7TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-43S-7C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-43S-8GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-8D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-43S-8DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-43S-8DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-43S-8T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-43S-8TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-43S-8C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-43S-BGS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-BD2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-43S-BDL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-43S-BDO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-43S-BT2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-43S-BTL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-43S-BC2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-43S-JGS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-JD2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-43S-JDL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-43S-JDO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-43S-JT2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-43S-JTL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-43S-JC2 Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-43V-1GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-1D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-43V-1DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-43V-1DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-43V-1T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-43V-1TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-43V-1C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-43V-2GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-2D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-43V-2DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-43V-2DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-43V-2T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-43V-2TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-43V-2C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-43V-3GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-3D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-43V-3DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-43V-3DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-43V-3T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-43V-3TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-43V-3C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-43V-4GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-4D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-43V-4DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-43V-4DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-43V-4T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-43V-4TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-43V-4C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-43V-5G2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-43V-5GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-5D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-43V-5DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-43V-5DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-43V-5T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-43V-5TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-43V-5C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-43V-5F2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-43V-6G2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-43V-6GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-6D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-43V-6DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-43V-6DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-43V-6T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-43V-6TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-43V-6C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-43V-6F2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-43V-7GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-7D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-43V-7DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-43V-7DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-43V-7T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-43V-7TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-43V-7C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-43V-8GS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-8D2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-43V-8DL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-43V-8DO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-43V-8T2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-43V-8TL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-43V-8C2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-43V-BGS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-BD2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-43V-BDL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-43V-BDO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-43V-BT2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-43V-BTL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-43V-BC2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-43V-JGS2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-JD2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-43V-JDL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-43V-JDO2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-43V-JT2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-43V-JTL2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-43V-JC2 Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-32S-1GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-1D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-32S-1DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-32S-1DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-32S-1T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-32S-1TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-32S-1C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-32S-2GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-2D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-32S-2DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-32S-2DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-32S-2T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-32S-2TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-32S-2C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-32S-3GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-3D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-32S-3DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-32S-3DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-32S-3T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-32S-3TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-32S-3C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-32S-4GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-4D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-32S-4DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-32S-4DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-32S-4T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-32S-4TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-32S-4C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-32S-5G2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-32S-5GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-5D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-32S-5DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-32S-5DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-32S-5T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-32S-5TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-32S-5C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-32S-5F2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-32S-6G2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-32S-6GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-6D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-32S-6DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-32S-6DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-32S-6T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-32S-6TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-32S-6C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-32S-6F2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-32S-7GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-7D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-32S-7DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-32S-7DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-32S-7T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-32S-7TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-32S-7C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-32S-8GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-8D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-32S-8DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-32S-8DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-32S-8T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-32S-8TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-32S-8C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-32S-BGS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-BD2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-32S-BDL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-32S-BDO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-32S-BT2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-32S-BTL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-32S-BC2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-32S-JGS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-JD2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-32S-JDL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-32S-JDO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-32S-JT2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-32S-JTL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-32S-JC2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-32V-1GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-1D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-32V-1DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-32V-1DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-32V-1T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-32V-1TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-32V-1C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-32V-2GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-2D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-32V-2DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-32V-2DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-32V-2T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-32V-2TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-32V-2C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-32V-3GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-3D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-32V-3DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-32V-3DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-32V-3T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-32V-3TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-32V-3C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-32V-4GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-4D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-32V-4DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-32V-4DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-32V-4T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-32V-4TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-32V-4C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-32V-5G2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-32V-5GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-5D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-32V-5DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-32V-5DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-32V-5T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-32V-5TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-32V-5C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-32V-5F2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-32V-6G2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-32V-6GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-6D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-32V-6DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-32V-6DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-32V-6T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-32V-6TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-32V-6C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-32V-6F2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-32V-7GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-7D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-32V-7DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-32V-7DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-32V-7T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-32V-7TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-32V-7C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-32V-8GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-8D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-32V-8DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-32V-8DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-32V-8T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-32V-8TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-32V-8C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-32V-BGS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-BD2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-32V-BDL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-32V-BDO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-32V-BT2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-32V-BTL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-32V-BC2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-32V-JGS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-JD2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-32V-JDL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-32V-JDO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-32V-JT2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-32V-JTL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-32V-JC2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-43S-1GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-1D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-43S-1DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-43S-1DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-43S-1T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-43S-1TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-43S-1C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-43S-2GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-2D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-43S-2DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-43S-2DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-43S-2T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-43S-2TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-43S-2C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-43S-3GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-3D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-43S-3DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-43S-3DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-43S-3T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-43S-3TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-43S-3C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-43S-4GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-4D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-43S-4DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-43S-4DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-43S-4T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-43S-4TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-43S-4C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-43S-5G2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-43S-5GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-5D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-43S-5DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-43S-5DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-43S-5T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-43S-5TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-43S-5C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-43S-5F2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-43S-6G2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-43S-6GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-6D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-43S-6DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-43S-6DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-43S-6T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-43S-6TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-43S-6C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-43S-6F2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-43S-7GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-7D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-43S-7DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-43S-7DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-43S-7T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-43S-7TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-43S-7C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-43S-8GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-8D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-43S-8DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-43S-8DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-43S-8T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-43S-8TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-43S-8C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-43S-BGS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-BD2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-43S-BDL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-43S-BDO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-43S-BT2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-43S-BTL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-43S-BC2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-43S-JGS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-JD2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-43S-JDL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-43S-JDO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-43S-JT2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-43S-JTL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-43S-JC2 Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-43V-1GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-1D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-43V-1DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-43V-1DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-43V-1T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-43V-1TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-43V-1C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-43V-2GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-2D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-43V-2DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-43V-2DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-43V-2T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-43V-2TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-43V-2C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-43V-3GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-3D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-43V-3DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-43V-3DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-43V-3T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-43V-3TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-43V-3C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-43V-4GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-4D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-43V-4DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-43V-4DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-43V-4T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-43V-4TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-43V-4C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-43V-5G2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-43V-5GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-5D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-43V-5DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-43V-5DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-43V-5T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-43V-5TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-43V-5C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-43V-5F2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-43V-6G2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-43V-6GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-6D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-43V-6DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-43V-6DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-43V-6T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-43V-6TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-43V-6C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-43V-6F2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-43V-7GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-7D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-43V-7DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-43V-7DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-43V-7T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-43V-7TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-43V-7C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-43V-8GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-8D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-43V-8DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-43V-8DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-43V-8T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-43V-8TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-43V-8C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-43V-BGS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-BD2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-43V-BDL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-43V-BDO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-43V-BT2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-43V-BTL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-43V-BC2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-43V-JGS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-JD2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-43V-JDL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-43V-JDO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-43V-JT2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-43V-JTL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-43V-JC2 Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-11P-1GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-1D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-11P-1DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-11P-1DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-11P-1T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA1-11P-1TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-11P-1C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA1-11P-2GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-2D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-11P-2DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-11P-2DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-11P-2T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA1-11P-2TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-11P-2C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA1-11P-3GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-3D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-11P-3DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-11P-3DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-11P-3T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA1-11P-3TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-11P-3C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA1-11P-4GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-4D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-11P-4DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-11P-4DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-11P-4T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA1-11P-4TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-11P-4C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA1-11P-5G2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA1-11P-5GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-5D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-11P-5DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-11P-5DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-11P-5T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA1-11P-5TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-11P-5C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA1-11P-5F2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-11P-6G2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA1-11P-6GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-6D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-11P-6DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-11P-6DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-11P-6T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA1-11P-6TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-11P-6C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA1-11P-6F2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-11P-7GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-7D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-11P-7DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-11P-7DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-11P-7T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA1-11P-7TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-11P-7C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA1-11P-8GS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-8D2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-11P-8DL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-11P-8DO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-11P-8T2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA1-11P-8TL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-11P-8C2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA1-11P-BGS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-BD2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-11P-BDL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-11P-BDO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-11P-BT2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA1-11P-BTL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-11P-BC2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA1-11P-JGS2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-JD2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-11P-JDL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-11P-JDO2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-11P-JT2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA1-11P-JTL2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-11P-JC2 Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Conduit
XSA1-21P-1GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-1D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-21P-1DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-21P-1DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-21P-1T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA1-21P-1TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-21P-1C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA1-21P-2GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-2D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-21P-2DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-21P-2DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-21P-2T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA1-21P-2TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-21P-2C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA1-21P-3GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-3D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-21P-3DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-21P-3DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-21P-3T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA1-21P-3TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-21P-3C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA1-21P-4GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-4D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-21P-4DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-21P-4DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-21P-4T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA1-21P-4TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-21P-4C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA1-21P-5G2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA1-21P-5GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-5D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-21P-5DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-21P-5DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-21P-5T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA1-21P-5TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-21P-5C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA1-21P-5F2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-21P-6G2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA1-21P-6GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-6D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-21P-6DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-21P-6DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-21P-6T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA1-21P-6TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-21P-6C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA1-21P-6F2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-21P-7GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-7D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-21P-7DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-21P-7DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-21P-7T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA1-21P-7TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-21P-7C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA1-21P-8GS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-8D2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-21P-8DL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-21P-8DO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-21P-8T2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA1-21P-8TL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-21P-8C2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA1-21P-BGS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-BD2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-21P-BDL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-21P-BDO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-21P-BT2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA1-21P-BTL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-21P-BC2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA1-21P-JGS2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-JD2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-21P-JDL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-21P-JDO2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-21P-JT2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA1-21P-JTL2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-21P-JC2 Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Conduit
XSA2-22P-1GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-1D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-22P-1DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-22P-1DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-22P-1T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal
XSA2-22P-1TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-22P-1C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Conduit
XSA2-22P-2GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-2D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-22P-2DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-22P-2DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-22P-2T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal
XSA2-22P-2TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-22P-2C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Conduit
XSA2-22P-3GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-3D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-22P-3DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-22P-3DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-22P-3T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal
XSA2-22P-3TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-22P-3C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Conduit
XSA2-22P-4GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-4D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-22P-4DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-22P-4DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-22P-4T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal
XSA2-22P-4TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-22P-4C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Conduit
XSA2-22P-5G2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet
XSA2-22P-5GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-5D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-22P-5DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-22P-5DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-22P-5T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal
XSA2-22P-5TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-22P-5C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Conduit
XSA2-22P-5F2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-22P-6G2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet
XSA2-22P-6GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-6D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-22P-6DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-22P-6DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-22P-6T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal
XSA2-22P-6TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-22P-6C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Conduit
XSA2-22P-6F2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-22P-7GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-7D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-22P-7DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-22P-7DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-22P-7T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal
XSA2-22P-7TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-22P-7C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Conduit
XSA2-22P-8GS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-8D2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-22P-8DL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-22P-8DO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-22P-8T2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal
XSA2-22P-8TL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-22P-8C2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Conduit
XSA2-22P-BGS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-BD2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-22P-BDL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-22P-BDO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-22P-BT2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal
XSA2-22P-BTL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-22P-BC2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Conduit
XSA2-22P-JGS2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-JD2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-22P-JDL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-22P-JDO2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-22P-JT2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal
XSA2-22P-JTL2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-22P-JC2 Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Conduit
XSA2-32P-1GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-1D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-32P-1DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-32P-1DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-32P-1T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal
XSA2-32P-1TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-32P-1C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Conduit
XSA2-32P-2GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-2D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-32P-2DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-32P-2DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-32P-2T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal
XSA2-32P-2TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-32P-2C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Conduit
XSA2-32P-3GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-3D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-32P-3DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-32P-3DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-32P-3T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal
XSA2-32P-3TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-32P-3C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Conduit
XSA2-32P-4GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-4D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-32P-4DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-32P-4DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-32P-4T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal
XSA2-32P-4TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-32P-4C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Conduit
XSA2-32P-5G2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet
XSA2-32P-5GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-5D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-32P-5DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-32P-5DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-32P-5T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal
XSA2-32P-5TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-32P-5C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Conduit
XSA2-32P-5F2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-32P-6G2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet
XSA2-32P-6GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-6D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-32P-6DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-32P-6DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-32P-6T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal
XSA2-32P-6TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-32P-6C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Conduit
XSA2-32P-6F2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-32P-7GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-7D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-32P-7DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-32P-7DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-32P-7T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal
XSA2-32P-7TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-32P-7C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Conduit
XSA2-32P-8GS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-8D2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-32P-8DL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-32P-8DO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-32P-8T2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal
XSA2-32P-8TL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-32P-8C2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Conduit
XSA2-32P-BGS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-BD2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-32P-BDL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-32P-BDO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-32P-BT2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal
XSA2-32P-BTL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-32P-BC2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Conduit
XSA2-32P-JGS2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-JD2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-32P-JDL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-32P-JDO2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-32P-JT2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal
XSA2-32P-JTL2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-32P-JC2 Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Conduit
XSA3-33P-1GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-1D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-33P-1DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-33P-1DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-33P-1T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA3-33P-1TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-33P-1C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA3-33P-2GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-2D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-33P-2DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-33P-2DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-33P-2T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA3-33P-2TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-33P-2C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA3-33P-3GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-3D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-33P-3DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-33P-3DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-33P-3T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA3-33P-3TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-33P-3C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA3-33P-4GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-4D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-33P-4DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-33P-4DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-33P-4T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA3-33P-4TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-33P-4C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA3-33P-5G2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA3-33P-5GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-5D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-33P-5DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-33P-5DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-33P-5T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA3-33P-5TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-33P-5C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA3-33P-5F2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-33P-6G2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA3-33P-6GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-6D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-33P-6DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-33P-6DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-33P-6T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA3-33P-6TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-33P-6C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA3-33P-6F2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-33P-7GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-7D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-33P-7DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-33P-7DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-33P-7T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA3-33P-7TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-33P-7C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA3-33P-8GS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-8D2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-33P-8DL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-33P-8DO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-33P-8T2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA3-33P-8TL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-33P-8C2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA3-33P-BGS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-BD2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-33P-BDL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-33P-BDO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-33P-BT2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA3-33P-BTL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-33P-BC2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA3-33P-JGS2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-JD2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-33P-JDL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-33P-JDO2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-33P-JT2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA3-33P-JTL2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-33P-JC2 Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Conduit
XSA3-43P-1GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-1D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-43P-1DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-43P-1DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-43P-1T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA3-43P-1TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-43P-1C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA3-43P-2GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-2D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-43P-2DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-43P-2DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-43P-2T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA3-43P-2TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-43P-2C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA3-43P-3GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-3D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-43P-3DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-43P-3DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-43P-3T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA3-43P-3TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-43P-3C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA3-43P-4GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-4D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-43P-4DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-43P-4DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-43P-4T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA3-43P-4TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-43P-4C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA3-43P-5G2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA3-43P-5GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-5D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-43P-5DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-43P-5DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-43P-5T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA3-43P-5TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-43P-5C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA3-43P-5F2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-43P-6G2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA3-43P-6GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-6D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-43P-6DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-43P-6DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-43P-6T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA3-43P-6TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-43P-6C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA3-43P-6F2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-43P-7GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-7D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-43P-7DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-43P-7DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-43P-7T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA3-43P-7TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-43P-7C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA3-43P-8GS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-8D2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-43P-8DL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-43P-8DO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-43P-8T2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA3-43P-8TL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-43P-8C2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA3-43P-BGS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-BD2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-43P-BDL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-43P-BDO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-43P-BT2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA3-43P-BTL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-43P-BC2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA3-43P-JGS2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-JD2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-43P-JDL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-43P-JDO2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-43P-JT2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA3-43P-JTL2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-43P-JC2 Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Conduit
High Vacuum ValvesSMC
1480 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC XSA High Vacuum 2-Port Solenoid Valve (N.C., Orifice 2-6 mm)

Brand SMC·High Vacuum Valves

Available part numbers (1480)

XSA1-12S-1GS2, XSA1-12S-1D2, XSA1-12S-1DL2, XSA1-12S-1DO2, XSA1-12S-1T2, XSA1-12S-1TL2, XSA1-12S-1C2, XSA1-12S-2GS2, XSA1-12S-2D2, XSA1-12S-2DL2 + 1470 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
XSA1-12S-1GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-1D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-12S-1DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-12S-1DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-12S-1T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-12S-1TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-12S-1C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-12S-2GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-2D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-12S-2DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-12S-2DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-12S-2T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-12S-2TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-12S-2C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-12S-3GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-3D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-12S-3DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-12S-3DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-12S-3T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-12S-3TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-12S-3C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-12S-4GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-4D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-12S-4DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-12S-4DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-12S-4T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-12S-4TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-12S-4C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-12S-5G2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-12S-5GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-5D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-12S-5DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-12S-5DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-12S-5T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-12S-5TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-12S-5C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-12S-5F2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-12S-6G2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-12S-6GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-6D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-12S-6DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-12S-6DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-12S-6T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-12S-6TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-12S-6C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-12S-6F2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-12S-7GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-7D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-12S-7DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-12S-7DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-12S-7T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-12S-7TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-12S-7C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-12S-8GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-8D2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-12S-8DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-12S-8DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-12S-8T2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-12S-8TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-12S-8C2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-12S-BGS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-BD2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-12S-BDL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-12S-BDO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-12S-BT2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-12S-BTL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-12S-BC2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-12S-JGS2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-12S-JD2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-12S-JDL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-12S-JDO2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-12S-JT2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-12S-JTL2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-12S-JC2Valve size: Size 1 | Orifice: 2 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-12V-1GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-1D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-12V-1DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-12V-1DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-12V-1T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-12V-1TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-12V-1C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-12V-2GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-2D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-12V-2DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-12V-2DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-12V-2T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-12V-2TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-12V-2C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-12V-3GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-3D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-12V-3DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-12V-3DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-12V-3T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-12V-3TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-12V-3C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-12V-4GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-4D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-12V-4DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-12V-4DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-12V-4T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-12V-4TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-12V-4C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-12V-5G2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-12V-5GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-5D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-12V-5DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-12V-5DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-12V-5T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-12V-5TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-12V-5C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-12V-5F2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-12V-6G2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-12V-6GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-6D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-12V-6DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-12V-6DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-12V-6T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-12V-6TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-12V-6C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-12V-6F2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-12V-7GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-7D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-12V-7DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-12V-7DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-12V-7T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-12V-7TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-12V-7C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-12V-8GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-8D2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-12V-8DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-12V-8DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-12V-8T2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-12V-8TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-12V-8C2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-12V-BGS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-BD2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-12V-BDL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-12V-BDO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-12V-BT2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-12V-BTL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-12V-BC2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-12V-JGS2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-12V-JD2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-12V-JDL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-12V-JDO2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-12V-JT2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-12V-JTL2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-12V-JC2Valve size: Size 1 | Orifice: 2 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-22S-1GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-1D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-22S-1DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-22S-1DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-22S-1T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-22S-1TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-22S-1C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-22S-2GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-2D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-22S-2DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-22S-2DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-22S-2T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-22S-2TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-22S-2C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-22S-3GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-3D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-22S-3DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-22S-3DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-22S-3T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-22S-3TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-22S-3C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-22S-4GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-4D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-22S-4DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-22S-4DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-22S-4T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-22S-4TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-22S-4C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-22S-5G2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-22S-5GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-5D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-22S-5DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-22S-5DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-22S-5T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-22S-5TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-22S-5C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-22S-5F2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-22S-6G2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-22S-6GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-6D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-22S-6DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-22S-6DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-22S-6T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-22S-6TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-22S-6C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-22S-6F2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-22S-7GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-7D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-22S-7DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-22S-7DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-22S-7T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-22S-7TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-22S-7C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-22S-8GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-8D2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-22S-8DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-22S-8DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-22S-8T2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-22S-8TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-22S-8C2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-22S-BGS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-BD2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-22S-BDL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-22S-BDO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-22S-BT2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-22S-BTL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-22S-BC2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-22S-JGS2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-22S-JD2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-22S-JDL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-22S-JDO2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-22S-JT2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-22S-JTL2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-22S-JC2Valve size: Size 1 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-22V-1GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-1D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-22V-1DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-22V-1DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-22V-1T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA1-22V-1TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-22V-1C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA1-22V-2GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-2D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-22V-2DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-22V-2DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-22V-2T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA1-22V-2TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-22V-2C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA1-22V-3GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-3D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-22V-3DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-22V-3DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-22V-3T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA1-22V-3TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-22V-3C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA1-22V-4GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-4D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-22V-4DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-22V-4DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-22V-4T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA1-22V-4TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-22V-4C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA1-22V-5G2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA1-22V-5GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-5D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-22V-5DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-22V-5DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-22V-5T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA1-22V-5TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-22V-5C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA1-22V-5F2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-22V-6G2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA1-22V-6GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-6D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-22V-6DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-22V-6DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-22V-6T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA1-22V-6TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-22V-6C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA1-22V-6F2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-22V-7GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-7D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-22V-7DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-22V-7DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-22V-7T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA1-22V-7TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-22V-7C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA1-22V-8GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-8D2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-22V-8DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-22V-8DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-22V-8T2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA1-22V-8TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-22V-8C2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA1-22V-BGS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-BD2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-22V-BDL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-22V-BDO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-22V-BT2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA1-22V-BTL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-22V-BC2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA1-22V-JGS2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-22V-JD2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-22V-JDL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-22V-JDO2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-22V-JT2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA1-22V-JTL2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-22V-JC2Valve size: Size 1 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-22S-1GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-1D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-22S-1DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-22S-1DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-22S-1T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-22S-1TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-22S-1C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-22S-2GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-2D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-22S-2DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-22S-2DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-22S-2T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-22S-2TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-22S-2C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-22S-3GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-3D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-22S-3DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-22S-3DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-22S-3T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-22S-3TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-22S-3C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-22S-4GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-4D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-22S-4DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-22S-4DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-22S-4T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-22S-4TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-22S-4C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-22S-5G2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-22S-5GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-5D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-22S-5DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-22S-5DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-22S-5T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-22S-5TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-22S-5C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-22S-5F2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-22S-6G2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-22S-6GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-6D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-22S-6DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-22S-6DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-22S-6T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-22S-6TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-22S-6C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-22S-6F2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-22S-7GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-7D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-22S-7DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-22S-7DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-22S-7T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-22S-7TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-22S-7C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-22S-8GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-8D2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-22S-8DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-22S-8DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-22S-8T2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-22S-8TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-22S-8C2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-22S-BGS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-BD2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-22S-BDL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-22S-BDO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-22S-BT2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-22S-BTL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-22S-BC2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-22S-JGS2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-22S-JD2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-22S-JDL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-22S-JDO2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-22S-JT2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-22S-JTL2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-22S-JC2Valve size: Size 2 | Orifice: 3 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-22V-1GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-1D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-22V-1DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-22V-1DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-22V-1T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-22V-1TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-22V-1C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-22V-2GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-2D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-22V-2DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-22V-2DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-22V-2T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-22V-2TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-22V-2C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-22V-3GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-3D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-22V-3DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-22V-3DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-22V-3T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-22V-3TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-22V-3C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-22V-4GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-4D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-22V-4DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-22V-4DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-22V-4T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-22V-4TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-22V-4C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-22V-5G2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-22V-5GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-5D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-22V-5DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-22V-5DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-22V-5T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-22V-5TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-22V-5C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-22V-5F2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-22V-6G2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-22V-6GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-6D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-22V-6DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-22V-6DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-22V-6T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-22V-6TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-22V-6C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-22V-6F2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-22V-7GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-7D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-22V-7DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-22V-7DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-22V-7T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-22V-7TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-22V-7C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-22V-8GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-8D2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-22V-8DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-22V-8DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-22V-8T2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-22V-8TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-22V-8C2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-22V-BGS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-BD2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-22V-BDL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-22V-BDO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-22V-BT2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-22V-BTL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-22V-BC2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-22V-JGS2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-22V-JD2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-22V-JDL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-22V-JDO2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-22V-JT2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-22V-JTL2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-22V-JC2Valve size: Size 2 | Orifice: 3 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-32S-1GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-1D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-32S-1DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-32S-1DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-32S-1T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-32S-1TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-32S-1C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-32S-2GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-2D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-32S-2DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-32S-2DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-32S-2T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-32S-2TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-32S-2C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-32S-3GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-3D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-32S-3DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-32S-3DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-32S-3T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-32S-3TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-32S-3C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-32S-4GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-4D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-32S-4DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-32S-4DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-32S-4T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-32S-4TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-32S-4C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-32S-5G2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-32S-5GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-5D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-32S-5DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-32S-5DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-32S-5T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-32S-5TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-32S-5C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-32S-5F2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-32S-6G2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-32S-6GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-6D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-32S-6DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-32S-6DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-32S-6T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-32S-6TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-32S-6C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-32S-6F2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-32S-7GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-7D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-32S-7DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-32S-7DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-32S-7T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-32S-7TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-32S-7C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-32S-8GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-8D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-32S-8DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-32S-8DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-32S-8T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-32S-8TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-32S-8C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-32S-BGS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-BD2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-32S-BDL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-32S-BDO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-32S-BT2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-32S-BTL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-32S-BC2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-32S-JGS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-32S-JD2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-32S-JDL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-32S-JDO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-32S-JT2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-32S-JTL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-32S-JC2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-32V-1GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-1D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-32V-1DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-32V-1DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-32V-1T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-32V-1TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-32V-1C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-32V-2GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-2D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-32V-2DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-32V-2DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-32V-2T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-32V-2TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-32V-2C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-32V-3GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-3D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-32V-3DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-32V-3DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-32V-3T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-32V-3TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-32V-3C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-32V-4GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-4D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-32V-4DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-32V-4DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-32V-4T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-32V-4TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-32V-4C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-32V-5G2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-32V-5GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-5D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-32V-5DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-32V-5DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-32V-5T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-32V-5TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-32V-5C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-32V-5F2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-32V-6G2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-32V-6GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-6D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-32V-6DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-32V-6DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-32V-6T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-32V-6TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-32V-6C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-32V-6F2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-32V-7GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-7D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-32V-7DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-32V-7DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-32V-7T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-32V-7TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-32V-7C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-32V-8GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-8D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-32V-8DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-32V-8DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-32V-8T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-32V-8TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-32V-8C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-32V-BGS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-BD2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-32V-BDL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-32V-BDO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-32V-BT2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-32V-BTL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-32V-BC2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-32V-JGS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-32V-JD2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-32V-JDL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-32V-JDO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-32V-JT2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-32V-JTL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-32V-JC2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-43S-1GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-1D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-43S-1DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-43S-1DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-43S-1T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-43S-1TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-43S-1C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-43S-2GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-2D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-43S-2DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-43S-2DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-43S-2T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-43S-2TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-43S-2C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-43S-3GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-3D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-43S-3DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-43S-3DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-43S-3T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-43S-3TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-43S-3C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-43S-4GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-4D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-43S-4DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-43S-4DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-43S-4T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-43S-4TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-43S-4C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-43S-5G2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-43S-5GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-5D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-43S-5DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-43S-5DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-43S-5T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-43S-5TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-43S-5C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-43S-5F2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-43S-6G2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-43S-6GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-6D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-43S-6DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-43S-6DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-43S-6T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-43S-6TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-43S-6C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-43S-6F2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-43S-7GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-7D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-43S-7DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-43S-7DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-43S-7T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-43S-7TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-43S-7C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-43S-8GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-8D2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-43S-8DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-43S-8DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-43S-8T2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-43S-8TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-43S-8C2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-43S-BGS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-BD2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-43S-BDL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-43S-BDO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-43S-BT2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-43S-BTL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-43S-BC2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-43S-JGS2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-43S-JD2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-43S-JDL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-43S-JDO2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-43S-JT2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-43S-JTL2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-43S-JC2Valve size: Size 2 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA2-43V-1GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-1D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-43V-1DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-43V-1DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-43V-1T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA2-43V-1TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-43V-1C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA2-43V-2GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-2D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-43V-2DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-43V-2DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-43V-2T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA2-43V-2TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-43V-2C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA2-43V-3GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-3D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-43V-3DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-43V-3DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-43V-3T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA2-43V-3TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-43V-3C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA2-43V-4GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-4D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-43V-4DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-43V-4DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-43V-4T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA2-43V-4TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-43V-4C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA2-43V-5G2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA2-43V-5GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-5D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-43V-5DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-43V-5DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-43V-5T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA2-43V-5TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-43V-5C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA2-43V-5F2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-43V-6G2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA2-43V-6GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-6D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-43V-6DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-43V-6DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-43V-6T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA2-43V-6TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-43V-6C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA2-43V-6F2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-43V-7GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-7D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-43V-7DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-43V-7DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-43V-7T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA2-43V-7TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-43V-7C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA2-43V-8GS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-8D2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-43V-8DL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-43V-8DO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-43V-8T2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA2-43V-8TL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-43V-8C2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA2-43V-BGS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-BD2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-43V-BDL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-43V-BDO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-43V-BT2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA2-43V-BTL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-43V-BC2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA2-43V-JGS2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-43V-JD2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-43V-JDL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-43V-JDO2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-43V-JT2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA2-43V-JTL2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-43V-JC2Valve size: Size 2 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-32S-1GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-1D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-32S-1DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-32S-1DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-32S-1T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-32S-1TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-32S-1C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-32S-2GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-2D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-32S-2DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-32S-2DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-32S-2T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-32S-2TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-32S-2C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-32S-3GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-3D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-32S-3DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-32S-3DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-32S-3T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-32S-3TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-32S-3C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-32S-4GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-4D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-32S-4DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-32S-4DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-32S-4T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-32S-4TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-32S-4C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-32S-5G2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-32S-5GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-5D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-32S-5DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-32S-5DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-32S-5T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-32S-5TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-32S-5C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-32S-5F2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-32S-6G2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-32S-6GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-6D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-32S-6DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-32S-6DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-32S-6T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-32S-6TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-32S-6C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-32S-6F2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-32S-7GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-7D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-32S-7DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-32S-7DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-32S-7T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-32S-7TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-32S-7C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-32S-8GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-8D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-32S-8DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-32S-8DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-32S-8T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-32S-8TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-32S-8C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-32S-BGS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-BD2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-32S-BDL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-32S-BDO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-32S-BT2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-32S-BTL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-32S-BC2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-32S-JGS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-32S-JD2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-32S-JDL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-32S-JDO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-32S-JT2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-32S-JTL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-32S-JC2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Compression fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-32V-1GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-1D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-32V-1DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-32V-1DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-32V-1T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-32V-1TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-32V-1C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-32V-2GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-2D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-32V-2DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-32V-2DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-32V-2T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-32V-2TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-32V-2C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-32V-3GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-3D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-32V-3DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-32V-3DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-32V-3T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-32V-3TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-32V-3C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-32V-4GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-4D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-32V-4DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-32V-4DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-32V-4T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-32V-4TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-32V-4C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-32V-5G2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-32V-5GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-5D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-32V-5DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-32V-5DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-32V-5T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-32V-5TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-32V-5C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-32V-5F2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-32V-6G2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-32V-6GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-6D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-32V-6DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-32V-6DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-32V-6T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-32V-6TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-32V-6C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-32V-6F2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-32V-7GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-7D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-32V-7DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-32V-7DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-32V-7T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-32V-7TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-32V-7C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-32V-8GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-8D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-32V-8DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-32V-8DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-32V-8T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-32V-8TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-32V-8C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-32V-BGS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-BD2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-32V-BDL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-32V-BDO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-32V-BT2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-32V-BTL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-32V-BC2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-32V-JGS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-32V-JD2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-32V-JDL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-32V-JDO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-32V-JT2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-32V-JTL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-32V-JC2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Face seal fitting | Port size: 1/4 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-43S-1GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-1D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-43S-1DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-43S-1DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-43S-1T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-43S-1TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-43S-1C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-43S-2GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-2D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-43S-2DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-43S-2DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-43S-2T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-43S-2TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-43S-2C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-43S-3GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-3D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-43S-3DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-43S-3DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-43S-3T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-43S-3TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-43S-3C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-43S-4GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-4D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-43S-4DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-43S-4DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-43S-4T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-43S-4TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-43S-4C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-43S-5G2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-43S-5GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-5D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-43S-5DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-43S-5DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-43S-5T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-43S-5TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-43S-5C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-43S-5F2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-43S-6G2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-43S-6GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-6D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-43S-6DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-43S-6DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-43S-6T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-43S-6TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-43S-6C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-43S-6F2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-43S-7GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-7D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-43S-7DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-43S-7DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-43S-7T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-43S-7TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-43S-7C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-43S-8GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-8D2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-43S-8DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-43S-8DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-43S-8T2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-43S-8TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-43S-8C2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-43S-BGS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-BD2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-43S-BDL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-43S-BDO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-43S-BT2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-43S-BTL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-43S-BC2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-43S-JGS2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-43S-JD2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-43S-JDL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-43S-JDO2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-43S-JT2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-43S-JTL2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-43S-JC2Valve size: Size 3 | Orifice: 6 mm | Connection: Compression fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA3-43V-1GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-1D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-43V-1DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-43V-1DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-43V-1T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal
XSA3-43V-1TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-43V-1C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC100V | Lead wire entry: Conduit
XSA3-43V-2GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-2D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-43V-2DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-43V-2DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-43V-2T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal
XSA3-43V-2TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-43V-2C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC200V | Lead wire entry: Conduit
XSA3-43V-3GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-3D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-43V-3DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-43V-3DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-43V-3T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal
XSA3-43V-3TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-43V-3C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC110V | Lead wire entry: Conduit
XSA3-43V-4GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-4D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-43V-4DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-43V-4DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-43V-4T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal
XSA3-43V-4TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-43V-4C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC220V | Lead wire entry: Conduit
XSA3-43V-5G2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet
XSA3-43V-5GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-5D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-43V-5DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-43V-5DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-43V-5T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal
XSA3-43V-5TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-43V-5C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Conduit
XSA3-43V-5F2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-43V-6G2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet
XSA3-43V-6GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-6D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-43V-6DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-43V-6DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-43V-6T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal
XSA3-43V-6TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-43V-6C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Conduit
XSA3-43V-6F2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-43V-7GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-7D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-43V-7DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-43V-7DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-43V-7T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal
XSA3-43V-7TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-43V-7C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC240V | Lead wire entry: Conduit
XSA3-43V-8GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-8D2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-43V-8DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-43V-8DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-43V-8T2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal
XSA3-43V-8TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-43V-8C2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC48V | Lead wire entry: Conduit
XSA3-43V-BGS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-BD2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-43V-BDL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-43V-BDO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-43V-BT2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal
XSA3-43V-BTL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-43V-BC2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC24V | Lead wire entry: Conduit
XSA3-43V-JGS2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-43V-JD2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-43V-JDL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-43V-JDO2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-43V-JT2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal
XSA3-43V-JTL2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-43V-JC2Valve size: Size 3 | Orifice: 6 mm | Connection: Face seal fitting | Port size: 3/8 in | Voltage: AC230V | Lead wire entry: Conduit
XSA1-11P-1GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-1D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-11P-1DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-11P-1DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-11P-1T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA1-11P-1TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-11P-1C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA1-11P-2GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-2D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-11P-2DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-11P-2DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-11P-2T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA1-11P-2TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-11P-2C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA1-11P-3GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-3D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-11P-3DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-11P-3DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-11P-3T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA1-11P-3TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-11P-3C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA1-11P-4GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-4D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-11P-4DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-11P-4DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-11P-4T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA1-11P-4TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-11P-4C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA1-11P-5G2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA1-11P-5GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-5D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-11P-5DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-11P-5DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-11P-5T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA1-11P-5TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-11P-5C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA1-11P-5F2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-11P-6G2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA1-11P-6GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-6D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-11P-6DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-11P-6DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-11P-6T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA1-11P-6TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-11P-6C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA1-11P-6F2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-11P-7GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-7D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-11P-7DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-11P-7DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-11P-7T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA1-11P-7TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-11P-7C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA1-11P-8GS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-8D2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-11P-8DL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-11P-8DO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-11P-8T2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA1-11P-8TL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-11P-8C2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA1-11P-BGS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-BD2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-11P-BDL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-11P-BDO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-11P-BT2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA1-11P-BTL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-11P-BC2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA1-11P-JGS2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-11P-JD2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-11P-JDL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-11P-JDO2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-11P-JT2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA1-11P-JTL2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-11P-JC2Valve size: Size 1 | Orifice: 2 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Conduit
XSA1-21P-1GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-1D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA1-21P-1DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA1-21P-1DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA1-21P-1T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA1-21P-1TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA1-21P-1C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA1-21P-2GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-2D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA1-21P-2DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA1-21P-2DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA1-21P-2T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA1-21P-2TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA1-21P-2C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA1-21P-3GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-3D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA1-21P-3DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA1-21P-3DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA1-21P-3T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA1-21P-3TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA1-21P-3C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA1-21P-4GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-4D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA1-21P-4DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA1-21P-4DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA1-21P-4T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA1-21P-4TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA1-21P-4C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA1-21P-5G2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA1-21P-5GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-5D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA1-21P-5DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA1-21P-5DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA1-21P-5T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA1-21P-5TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA1-21P-5C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA1-21P-5F2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA1-21P-6G2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA1-21P-6GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-6D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA1-21P-6DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA1-21P-6DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA1-21P-6T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA1-21P-6TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA1-21P-6C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA1-21P-6F2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA1-21P-7GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-7D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA1-21P-7DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA1-21P-7DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA1-21P-7T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA1-21P-7TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA1-21P-7C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA1-21P-8GS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-8D2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA1-21P-8DL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA1-21P-8DO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA1-21P-8T2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA1-21P-8TL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA1-21P-8C2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA1-21P-BGS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-BD2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA1-21P-BDL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA1-21P-BDO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA1-21P-BT2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA1-21P-BTL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA1-21P-BC2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA1-21P-JGS2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA1-21P-JD2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA1-21P-JDL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA1-21P-JDO2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA1-21P-JT2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA1-21P-JTL2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA1-21P-JC2Valve size: Size 1 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/8 | Voltage: AC230V | Lead wire entry: Conduit
XSA2-22P-1GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-1D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-22P-1DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-22P-1DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-22P-1T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal
XSA2-22P-1TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-22P-1C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Conduit
XSA2-22P-2GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-2D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-22P-2DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-22P-2DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-22P-2T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal
XSA2-22P-2TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-22P-2C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Conduit
XSA2-22P-3GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-3D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-22P-3DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-22P-3DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-22P-3T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal
XSA2-22P-3TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-22P-3C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Conduit
XSA2-22P-4GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-4D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-22P-4DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-22P-4DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-22P-4T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal
XSA2-22P-4TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-22P-4C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Conduit
XSA2-22P-5G2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet
XSA2-22P-5GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-5D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-22P-5DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-22P-5DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-22P-5T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal
XSA2-22P-5TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-22P-5C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Conduit
XSA2-22P-5F2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-22P-6G2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet
XSA2-22P-6GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-6D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-22P-6DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-22P-6DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-22P-6T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal
XSA2-22P-6TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-22P-6C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Conduit
XSA2-22P-6F2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-22P-7GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-7D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-22P-7DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-22P-7DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-22P-7T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal
XSA2-22P-7TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-22P-7C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Conduit
XSA2-22P-8GS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-8D2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-22P-8DL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-22P-8DO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-22P-8T2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal
XSA2-22P-8TL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-22P-8C2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Conduit
XSA2-22P-BGS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-BD2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-22P-BDL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-22P-BDO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-22P-BT2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal
XSA2-22P-BTL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-22P-BC2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Conduit
XSA2-22P-JGS2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-22P-JD2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-22P-JDL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-22P-JDO2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-22P-JT2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal
XSA2-22P-JTL2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-22P-JC2Valve size: Size 2 | Orifice: 3 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Conduit
XSA2-32P-1GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-1D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA2-32P-1DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA2-32P-1DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA2-32P-1T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal
XSA2-32P-1TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA2-32P-1C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC100V | Lead wire entry: Conduit
XSA2-32P-2GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-2D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA2-32P-2DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA2-32P-2DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA2-32P-2T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal
XSA2-32P-2TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA2-32P-2C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC200V | Lead wire entry: Conduit
XSA2-32P-3GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-3D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA2-32P-3DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA2-32P-3DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA2-32P-3T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal
XSA2-32P-3TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA2-32P-3C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC110V | Lead wire entry: Conduit
XSA2-32P-4GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-4D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA2-32P-4DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA2-32P-4DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA2-32P-4T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal
XSA2-32P-4TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA2-32P-4C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC220V | Lead wire entry: Conduit
XSA2-32P-5G2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet
XSA2-32P-5GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-5D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA2-32P-5DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA2-32P-5DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA2-32P-5T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal
XSA2-32P-5TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA2-32P-5C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Conduit
XSA2-32P-5F2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA2-32P-6G2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet
XSA2-32P-6GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-6D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA2-32P-6DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA2-32P-6DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA2-32P-6T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal
XSA2-32P-6TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA2-32P-6C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Conduit
XSA2-32P-6F2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA2-32P-7GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-7D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA2-32P-7DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA2-32P-7DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA2-32P-7T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal
XSA2-32P-7TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA2-32P-7C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC240V | Lead wire entry: Conduit
XSA2-32P-8GS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-8D2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA2-32P-8DL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA2-32P-8DO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA2-32P-8T2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal
XSA2-32P-8TL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA2-32P-8C2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC48V | Lead wire entry: Conduit
XSA2-32P-BGS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-BD2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA2-32P-BDL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA2-32P-BDO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA2-32P-BT2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal
XSA2-32P-BTL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA2-32P-BC2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC24V | Lead wire entry: Conduit
XSA2-32P-JGS2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA2-32P-JD2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA2-32P-JDL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA2-32P-JDO2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA2-32P-JT2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal
XSA2-32P-JTL2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA2-32P-JC2Valve size: Size 2 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc1/4 | Voltage: AC230V | Lead wire entry: Conduit
XSA3-33P-1GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-1D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-33P-1DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-33P-1DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-33P-1T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA3-33P-1TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-33P-1C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA3-33P-2GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-2D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-33P-2DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-33P-2DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-33P-2T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA3-33P-2TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-33P-2C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA3-33P-3GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-3D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-33P-3DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-33P-3DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-33P-3T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA3-33P-3TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-33P-3C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA3-33P-4GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-4D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-33P-4DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-33P-4DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-33P-4T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA3-33P-4TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-33P-4C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA3-33P-5G2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA3-33P-5GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-5D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-33P-5DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-33P-5DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-33P-5T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA3-33P-5TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-33P-5C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA3-33P-5F2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-33P-6G2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA3-33P-6GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-6D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-33P-6DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-33P-6DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-33P-6T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA3-33P-6TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-33P-6C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA3-33P-6F2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-33P-7GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-7D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-33P-7DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-33P-7DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-33P-7T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA3-33P-7TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-33P-7C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA3-33P-8GS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-8D2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-33P-8DL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-33P-8DO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-33P-8T2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA3-33P-8TL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-33P-8C2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA3-33P-BGS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-BD2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-33P-BDL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-33P-BDO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-33P-BT2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA3-33P-BTL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-33P-BC2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA3-33P-JGS2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-33P-JD2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-33P-JDL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-33P-JDO2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-33P-JT2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA3-33P-JTL2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-33P-JC2Valve size: Size 3 | Orifice: 4.5 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Conduit
XSA3-43P-1GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-1D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal
XSA3-43P-1DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal with lamp
XSA3-43P-1DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: DIN terminal, no connector
XSA3-43P-1T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal
XSA3-43P-1TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Terminal with lamp
XSA3-43P-1C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC100V | Lead wire entry: Conduit
XSA3-43P-2GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-2D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal
XSA3-43P-2DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal with lamp
XSA3-43P-2DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: DIN terminal, no connector
XSA3-43P-2T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal
XSA3-43P-2TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Terminal with lamp
XSA3-43P-2C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC200V | Lead wire entry: Conduit
XSA3-43P-3GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-3D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal
XSA3-43P-3DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal with lamp
XSA3-43P-3DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: DIN terminal, no connector
XSA3-43P-3T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal
XSA3-43P-3TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Terminal with lamp
XSA3-43P-3C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC110V | Lead wire entry: Conduit
XSA3-43P-4GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-4D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal
XSA3-43P-4DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal with lamp
XSA3-43P-4DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: DIN terminal, no connector
XSA3-43P-4T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal
XSA3-43P-4TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Terminal with lamp
XSA3-43P-4C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC220V | Lead wire entry: Conduit
XSA3-43P-5G2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet
XSA3-43P-5GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-5D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal
XSA3-43P-5DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal with lamp
XSA3-43P-5DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: DIN terminal, no connector
XSA3-43P-5T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal
XSA3-43P-5TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Terminal with lamp
XSA3-43P-5C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Conduit
XSA3-43P-5F2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC24V | Lead wire entry: Flat terminal
XSA3-43P-6G2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet
XSA3-43P-6GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-6D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal
XSA3-43P-6DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal with lamp
XSA3-43P-6DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: DIN terminal, no connector
XSA3-43P-6T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal
XSA3-43P-6TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Terminal with lamp
XSA3-43P-6C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Conduit
XSA3-43P-6F2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: DC12V | Lead wire entry: Flat terminal
XSA3-43P-7GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-7D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal
XSA3-43P-7DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal with lamp
XSA3-43P-7DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: DIN terminal, no connector
XSA3-43P-7T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal
XSA3-43P-7TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Terminal with lamp
XSA3-43P-7C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC240V | Lead wire entry: Conduit
XSA3-43P-8GS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-8D2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal
XSA3-43P-8DL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal with lamp
XSA3-43P-8DO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: DIN terminal, no connector
XSA3-43P-8T2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal
XSA3-43P-8TL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Terminal with lamp
XSA3-43P-8C2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC48V | Lead wire entry: Conduit
XSA3-43P-BGS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-BD2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal
XSA3-43P-BDL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal with lamp
XSA3-43P-BDO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: DIN terminal, no connector
XSA3-43P-BT2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal
XSA3-43P-BTL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Terminal with lamp
XSA3-43P-BC2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC24V | Lead wire entry: Conduit
XSA3-43P-JGS2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Grommet, surge suppressor
XSA3-43P-JD2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal
XSA3-43P-JDL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal with lamp
XSA3-43P-JDO2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: DIN terminal, no connector
XSA3-43P-JT2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal
XSA3-43P-JTL2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Terminal with lamp
XSA3-43P-JC2Valve size: Size 3 | Orifice: 6 mm | Connection: Rc female thread | Port size: Rc3/8 | Voltage: AC230V | Lead wire entry: Conduit

Need a different model, or a part not listed here? Send us your parts list →