Skip to product information
1 of 1

SMC ZL1 Multistage Vacuum Ejector (100 L/min)

SMC ZL1 Multistage Vacuum Ejector (100 L/min)

SMC ZL1 multistage vacuum ejector with 100 L/min (ANR) max. suction flow, optional supply/release valves and vacuum pressure switch, gauge or detection port.

Key features

  • Multistage diffuser ejector, nozzle ø1.2 mm, max. vacuum -84 kPa, air consumption 57 L/min (ANR)
  • Lightweight 180 g (conventional ZL112: 450 g); interchangeable mounting with ZL112 (bottom adapter option B)
  • Supply valve N.C./N.O. with or without release valve (SYJ500 type pilot), DC24V M plug connector with light/surge suppressor in listed codes
  • Vacuum pressure switch with NPN/PNP 2 outputs plus copy, analog voltage or analog current output, lead wire with connector 2 m
  • Other voltages (DC12/6/5/3V, AC100/200/110/220V), grommet/L plug leads, lock manual (D), inch fittings (N), G/NPT exhaust ports on order

Specifications

Fluid Air
Nozzle diameter 1.2 mm
Standard supply pressure 0.33 MPa (no valve), 0.35 MPa (with valve)
Max. vacuum pressure -84 kPa
Max. suction flow 100 L/min (ANR)
Air consumption 57 L/min (ANR)
Supply pressure range 0.2 to 0.5 MPa
Operating temperature 5 to 50°C
Ports Supply ø6, vacuum ø12 one-touch fittings
Enclosure IP40
Source SMC Korea catalog ZL1/ZL3/ZL6 CAT.KS100-108E (SMCKR_ZL1_ZL3_ZL6.pdf), p. 9-10 (PDF p. 10-11)
ZL112A Exhaust: Silencer exhaust | Valves: None | Vacuum detection: None
ZL112A-GN Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Detection port Rc1/8
ZL112A-G Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Pressure gauge (kPa)
ZL112A-DXL Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-DXML Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-DYL Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-DYML Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-DRL Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-DRML Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-DSL Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-DSML Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-DTL Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-DTML Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-DVL Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-DVML Exhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-K15MZ Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: None
ZL112A-K15MZ-GN Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112A-K15MZ-G Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112A-K15MZ-DXL Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-K15MZ-DXML Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-K15MZ-DYL Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-K15MZ-DYML Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-K15MZ-DRL Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-K15MZ-DRML Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-K15MZ-DSL Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-K15MZ-DSML Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-K15MZ-DTL Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-K15MZ-DTML Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-K15MZ-DVL Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-K15MZ-DVML Exhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-K25MZ Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: None
ZL112A-K25MZ-GN Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Detection port Rc1/8
ZL112A-K25MZ-G Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112A-K25MZ-DXL Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-K25MZ-DXML Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-K25MZ-DYL Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-K25MZ-DYML Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-K25MZ-DRL Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-K25MZ-DRML Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-K25MZ-DSL Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-K25MZ-DSML Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-K25MZ-DTL Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-K25MZ-DTML Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-K25MZ-DVL Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-K25MZ-DVML Exhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-B15MZ Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: None
ZL112A-B15MZ-GN Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112A-B15MZ-G Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112A-B15MZ-DXL Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-B15MZ-DXML Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-B15MZ-DYL Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-B15MZ-DYML Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-B15MZ-DRL Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-B15MZ-DRML Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-B15MZ-DSL Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-B15MZ-DSML Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-B15MZ-DTL Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-B15MZ-DTML Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-B15MZ-DVL Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-B15MZ-DVML Exhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-B25MZ Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: None
ZL112A-B25MZ-GN Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Detection port Rc1/8
ZL112A-B25MZ-G Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Pressure gauge (kPa)
ZL112A-B25MZ-DXL Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-B25MZ-DXML Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-B25MZ-DYL Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-B25MZ-DYML Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-B25MZ-DRL Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-B25MZ-DRML Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-B25MZ-DSL Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-B25MZ-DSML Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-B25MZ-DTL Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-B25MZ-DTML Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-B25MZ-DVL Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-B25MZ-DVML Exhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: None
ZL112AP-GN Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Detection port Rc1/8
ZL112AP-G Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Pressure gauge (kPa)
ZL112AP-DXL Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-DXML Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-DYL Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-DYML Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-DRL Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-DRML Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-DSL Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-DSML Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-DTL Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-DTML Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-DVL Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-DVML Exhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-K15MZ Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: None
ZL112AP-K15MZ-GN Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112AP-K15MZ-G Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-K15MZ-DXL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-K15MZ-DXML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-K15MZ-DYL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-K15MZ-DYML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-K15MZ-DRL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-K15MZ-DRML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-K15MZ-DSL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-K15MZ-DSML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-K15MZ-DTL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-K15MZ-DTML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-K15MZ-DVL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-K15MZ-DVML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-K25MZ Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: None
ZL112AP-K25MZ-GN Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Detection port Rc1/8
ZL112AP-K25MZ-G Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-K25MZ-DXL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-K25MZ-DXML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-K25MZ-DYL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-K25MZ-DYML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-K25MZ-DRL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-K25MZ-DRML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-K25MZ-DSL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-K25MZ-DSML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-K25MZ-DTL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-K25MZ-DTML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-K25MZ-DVL Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-K25MZ-DVML Exhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-B15MZ Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: None
ZL112AP-B15MZ-GN Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112AP-B15MZ-G Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-B15MZ-DXL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-B15MZ-DXML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-B15MZ-DYL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-B15MZ-DYML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-B15MZ-DRL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-B15MZ-DRML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-B15MZ-DSL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-B15MZ-DSML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-B15MZ-DTL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-B15MZ-DTML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-B15MZ-DVL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-B15MZ-DVML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-B25MZ Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: None
ZL112AP-B25MZ-GN Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Detection port Rc1/8
ZL112AP-B25MZ-G Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-B25MZ-DXL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-B25MZ-DXML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-B25MZ-DYL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-B25MZ-DYML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-B25MZ-DRL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-B25MZ-DRML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-B25MZ-DSL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-B25MZ-DSML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-B25MZ-DTL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-B25MZ-DTML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-B25MZ-DVL Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-B25MZ-DVML Exhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
Vacuum EjectorsSMC
150 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

SMC ZL1 Multistage Vacuum Ejector (100 L/min)

Brand SMC·Vacuum Ejectors

Available part numbers (150)

ZL112A, ZL112A-GN, ZL112A-G, ZL112A-DXL, ZL112A-DXML, ZL112A-DYL, ZL112A-DYML, ZL112A-DRL, ZL112A-DRML, ZL112A-DSL + 140 more — see full table ↓

How to order

Send the SMC part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
ZL112AExhaust: Silencer exhaust | Valves: None | Vacuum detection: None
ZL112A-GNExhaust: Silencer exhaust | Valves: None | Vacuum detection: Detection port Rc1/8
ZL112A-GExhaust: Silencer exhaust | Valves: None | Vacuum detection: Pressure gauge (kPa)
ZL112A-DXLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-DXMLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-DYLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-DYMLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-DRLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-DRMLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-DSLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-DSMLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-DTLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-DTMLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-DVLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-DVMLExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-K15MZExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: None
ZL112A-K15MZ-GNExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112A-K15MZ-GExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112A-K15MZ-DXLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-K15MZ-DXMLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-K15MZ-DYLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-K15MZ-DYMLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-K15MZ-DRLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-K15MZ-DRMLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-K15MZ-DSLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-K15MZ-DSMLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-K15MZ-DTLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-K15MZ-DTMLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-K15MZ-DVLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-K15MZ-DVMLExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-K25MZExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: None
ZL112A-K25MZ-GNExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Detection port Rc1/8
ZL112A-K25MZ-GExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112A-K25MZ-DXLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-K25MZ-DXMLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-K25MZ-DYLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-K25MZ-DYMLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-K25MZ-DRLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-K25MZ-DRMLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-K25MZ-DSLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-K25MZ-DSMLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-K25MZ-DTLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-K25MZ-DTMLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-K25MZ-DVLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-K25MZ-DVMLExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-B15MZExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: None
ZL112A-B15MZ-GNExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112A-B15MZ-GExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112A-B15MZ-DXLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-B15MZ-DXMLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-B15MZ-DYLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-B15MZ-DYMLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-B15MZ-DRLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-B15MZ-DRMLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-B15MZ-DSLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-B15MZ-DSMLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-B15MZ-DTLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-B15MZ-DTMLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-B15MZ-DVLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-B15MZ-DVMLExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112A-B25MZExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: None
ZL112A-B25MZ-GNExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Detection port Rc1/8
ZL112A-B25MZ-GExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Pressure gauge (kPa)
ZL112A-B25MZ-DXLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112A-B25MZ-DXMLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112A-B25MZ-DYLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112A-B25MZ-DYMLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112A-B25MZ-DRLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112A-B25MZ-DRMLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112A-B25MZ-DSLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112A-B25MZ-DSMLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112A-B25MZ-DTLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112A-B25MZ-DTMLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112A-B25MZ-DVLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112A-B25MZ-DVMLExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112APExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: None
ZL112AP-GNExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Detection port Rc1/8
ZL112AP-GExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Pressure gauge (kPa)
ZL112AP-DXLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-DXMLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-DYLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-DYMLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-DRLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-DRMLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-DSLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-DSMLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-DTLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-DTMLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-DVLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-DVMLExhaust: Rc1/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-K15MZExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: None
ZL112AP-K15MZ-GNExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112AP-K15MZ-GExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-K15MZ-DXLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-K15MZ-DXMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-K15MZ-DYLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-K15MZ-DYMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-K15MZ-DRLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-K15MZ-DRMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-K15MZ-DSLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-K15MZ-DSMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-K15MZ-DTLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-K15MZ-DTMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-K15MZ-DVLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-K15MZ-DVMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-K25MZExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: None
ZL112AP-K25MZ-GNExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Detection port Rc1/8
ZL112AP-K25MZ-GExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-K25MZ-DXLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-K25MZ-DXMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-K25MZ-DYLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-K25MZ-DYMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-K25MZ-DRLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-K25MZ-DRMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-K25MZ-DSLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-K25MZ-DSMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-K25MZ-DTLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-K25MZ-DTMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-K25MZ-DVLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-K25MZ-DVMLExhaust: Rc1/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-B15MZExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: None
ZL112AP-B15MZ-GNExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Detection port Rc1/8
ZL112AP-B15MZ-GExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-B15MZ-DXLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-B15MZ-DXMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-B15MZ-DYLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-B15MZ-DYMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-B15MZ-DRLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-B15MZ-DRMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-B15MZ-DSLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-B15MZ-DSMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-B15MZ-DTLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-B15MZ-DTMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-B15MZ-DVLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-B15MZ-DVMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed
ZL112AP-B25MZExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: None
ZL112AP-B25MZ-GNExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Detection port Rc1/8
ZL112AP-B25MZ-GExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Pressure gauge (kPa)
ZL112AP-B25MZ-DXLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, switchable
ZL112AP-B25MZ-DXMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, SI fixed
ZL112AP-B25MZ-DYLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, switchable
ZL112AP-B25MZ-DYMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, SI fixed
ZL112AP-B25MZ-DRLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, switchable
ZL112AP-B25MZ-DRMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed
ZL112AP-B25MZ-DSLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, switchable
ZL112AP-B25MZ-DSMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed
ZL112AP-B25MZ-DTLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, switchable
ZL112AP-B25MZ-DTMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed
ZL112AP-B25MZ-DVLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, switchable
ZL112AP-B25MZ-DVMLExhaust: Rc1/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed

Need a different model, or a part not listed here? Send us your parts list →