Photoelectric
Omron
[OMRON] — E3Z-UL Retro-reflective Photoelectric Sensor (MSR 4m + Clear Bottle 500mm/2m, NPN/PNP, UL Certified)
Family ID: OMRON-E3Z-UL-REFLECT
OMRON E3Z Series UL certified retro-reflective photoelectric sensors. MSR models (E3Z-R61/81-UL): 4 m, red light. Clear plastic bottle models (E3Z-B61/62/81/82-UL): 500 mm and 2 m. Reflectors sold separately. NPN and PNP. Pre-wired 2 m and M8 connector.
12 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| E3Z-R61-UL 2M | UL retro MSR NPN 2m | OMRON | Sensing Distance: 4 m (min 100 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective with MSR function (UL certified) | Output: NPN | Certification: UL | Required Reflector: E39-R1S (sold separately) | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m | ||
| E3Z-R66-UL | UL retro MSR NPN M8 | OMRON | Sensing Distance: 4 m (min 100 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective with MSR function (UL certified) | Output: NPN | Certification: UL | Required Reflector: E39-R1S (sold separately) | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately) | ||
| E3Z-R81-UL 2M | UL retro MSR PNP 2m | OMRON | Sensing Distance: 4 m (min 100 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective with MSR function (UL certified) | Output: PNP | Certification: UL | Required Reflector: E39-R1S (sold separately) | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: Pre-wired 2 m | ||
| E3Z-R86-UL | UL retro MSR PNP M8 | OMRON | Sensing Distance: 4 m (min 100 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective with MSR function (UL certified) | Output: PNP | Certification: UL | Required Reflector: E39-R1S (sold separately) | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) / M12 standard pre-wired also available: add '-M1J' suffix (e.g. E3Z-T61-M1J-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately) | ||
| E3Z-B61-UL 2M | UL clear bottle retro 500 mm NPN 2m | OMRON | Sensing Distance: 500 mm (min 80 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: NPN | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: Pre-wired 2 m | ||
| E3Z-B66-UL | UL clear bottle retro 500 mm NPN M8 | OMRON | Sensing Distance: 500 mm (min 80 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: NPN | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately) | ||
| E3Z-B81-UL 2M | UL clear bottle retro 500 mm PNP 2m | OMRON | Sensing Distance: 500 mm (min 80 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: PNP | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: Pre-wired 2 m | ||
| E3Z-B86-UL | UL clear bottle retro 500 mm PNP M8 | OMRON | Sensing Distance: 500 mm (min 80 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: PNP | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately) | ||
| E3Z-B62-UL 2M | UL clear bottle retro 2 m NPN 2m | OMRON | Sensing Distance: 2 m (min 500 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: NPN | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: Pre-wired 2 m | ||
| E3Z-B67-UL | UL clear bottle retro 2 m NPN M8 | OMRON | Sensing Distance: 2 m (min 500 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: NPN | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately) | ||
| E3Z-B82-UL 2M | UL clear bottle retro 2 m PNP 2m | OMRON | Sensing Distance: 2 m (min 500 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: PNP | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: Pre-wired 2 m | ||
| E3Z-B87-UL | UL clear bottle retro 2 m PNP M8 | OMRON | Sensing Distance: 2 m (min 500 mm with E39-R1S) | Light Source: Red light | Sensing Method: Retro-reflective without MSR (clear bottle, UL certified) | Output: PNP | Certification: UL | Required Reflector: E39-R1S or E39-R1K sold separately | Also Available: M12 Smartclick pre-wired also available: add '-M1TJ' suffix (e.g. E3Z-T61-M1TJ-UL 0.3M) | Connection: M8 Connector | Required Cable: Requires XS3F-M421-402-R (2m) / XS3F-M421-405-R (5m) straight or XS3F-M422 right-angle (sold separately) |