AC Drives
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0002. Maximum applicable motor: ND 0.75kW / HD 0.4kW. Rated output current: ND 2.1A / HD 1.8A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0002. Maximum applicable motor: ND 0.75kW / HD 0.4kW. Rated output current: ND 2.1A / HD 1.8A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0002 | A1000 400V class AC drive/inverter; ND 0.75kW / HD 0.4kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0002 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 0.75kW / HD 0.4kW · Rated Input Current: ND 2.1A / HD 1.8A · Rated Output Capacity: ND 1.6kVA / HD 1.4kVA · Rated Output Current: ND 2.1A / HD 1.8A · Power Supply Capacity: ND 1.9kVA / HD 1.6kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0004. Maximum applicable motor: ND 1.5kW / HD 0.75kW. Rated output current: ND 4.1A / HD 3.4A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0004. Maximum applicable motor: ND 1.5kW / HD 0.75kW. Rated output current: ND 4.1A / HD 3.4A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0004 | A1000 400V class AC drive/inverter; ND 1.5kW / HD 0.75kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0004 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 1.5kW / HD 0.75kW · Rated Input Current: ND 4.3A / HD 3.2A · Rated Output Capacity: ND 3.1kVA / HD 2.6kVA · Rated Output Current: ND 4.1A / HD 3.4A · Power Supply Capacity: ND 3.9kVA / HD 2.9kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0005. Maximum applicable motor: ND 2.2kW / HD 1.5kW. Rated output current: ND 5.4A / HD 4.8A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0005. Maximum applicable motor: ND 2.2kW / HD 1.5kW. Rated output current: ND 5.4A / HD 4.8A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0005 | A1000 400V class AC drive/inverter; ND 2.2kW / HD 1.5kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0005 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 2.2kW / HD 1.5kW · Rated Input Current: ND 5.9A / HD 4.4A · Rated Output Capacity: ND 4.1kVA / HD 3.7kVA · Rated Output Current: ND 5.4A / HD 4.8A · Power Supply Capacity: ND 5.4kVA / HD 4kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0007. Maximum applicable motor: ND 3kW / HD 2.2kW. Rated output current: ND 6.9A / HD 5.5A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0007. Maximum applicable motor: ND 3kW / HD 2.2kW. Rated output current: ND 6.9A / HD 5.5A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0007 | A1000 400V class AC drive/inverter; ND 3kW / HD 2.2kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0007 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 3kW / HD 2.2kW · Rated Input Current: ND 8.1A / HD 6A · Rated Output Capacity: ND 5.3kVA / HD 4.2kVA · Rated Output Current: ND 6.9A / HD 5.5A · Power Supply Capacity: ND 7.4kVA / HD 5.5kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0009. Maximum applicable motor: ND 3.7kW / HD 3kW. Rated output current: ND 8.8A / HD 7.2A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0009. Maximum applicable motor: ND 3.7kW / HD 3kW. Rated output current: ND 8.8A / HD 7.2A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0009 | A1000 400V class AC drive/inverter; ND 3.7kW / HD 3kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0009 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 3.7kW / HD 3kW · Rated Input Current: ND 9.4A / HD 8.2A · Rated Output Capacity: ND 6.7kVA / HD 5.5kVA · Rated Output Current: ND 8.8A / HD 7.2A · Power Supply Capacity: ND 8.6kVA / HD 7.5kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0011. Maximum applicable motor: ND 5.5kW / HD 3.7kW. Rated output current: ND 11.1A / HD 9.2A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0011. Maximum applicable motor: ND 5.5kW / HD 3.7kW. Rated output current: ND 11.1A / HD 9.2A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0011 | A1000 400V class AC drive/inverter; ND 5.5kW / HD 3.7kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0011 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 5.5kW / HD 3.7kW · Rated Input Current: ND 14A / HD 10.4A · Rated Output Capacity: ND 8.5kVA / HD 7kVA · Rated Output Current: ND 11.1A / HD 9.2A · Power Supply Capacity: ND 12.8kVA / HD 10kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0018. Maximum applicable motor: ND 7.5kW / HD 5.5kW. Rated output current: ND 17.5A / HD 14.8A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0018. Maximum applicable motor: ND 7.5kW / HD 5.5kW. Rated output current: ND 17.5A / HD 14.8A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0018 | A1000 400V class AC drive/inverter; ND 7.5kW / HD 5.5kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0018 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 7.5kW / HD 5.5kW · Rated Input Current: ND 20A / HD 15A · Rated Output Capacity: ND 13.3kVA / HD 11.3kVA · Rated Output Current: ND 17.5A / HD 14.8A · Power Supply Capacity: ND 18.3kVA / HD 13.7kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0023. Maximum applicable motor: ND 11kW / HD 7.5kW. Rated output current: ND 23A / HD 18A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0023. Maximum applicable motor: ND 11kW / HD 7.5kW. Rated output current: ND 23A / HD 18A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0023 | A1000 400V class AC drive/inverter; ND 11kW / HD 7.5kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0023 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 11kW / HD 7.5kW · Rated Input Current: ND 24A / HD 20A · Rated Output Capacity: ND 17.5kVA / HD 13.7kVA · Rated Output Current: ND 23A / HD 18A · Power Supply Capacity: ND 22kVA / HD 18.3kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0031. Maximum applicable motor: ND 15kW / HD 11kW. Rated output current: ND 31A / HD 24A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0031. Maximum applicable motor: ND 15kW / HD 11kW. Rated output current: ND 31A / HD 24A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0031 | A1000 400V class AC drive/inverter; ND 15kW / HD 11kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0031 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 15kW / HD 11kW · Rated Input Current: ND 38A / HD 29A · Rated Output Capacity: ND 24kVA / HD 18.3kVA · Rated Output Current: ND 31A / HD 24A · Power Supply Capacity: ND 35kVA / HD 27kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0038. Maximum applicable motor: ND 18.5kW / HD 15kW. Rated output current: ND 38A / HD 31A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0038. Maximum applicable motor: ND 18.5kW / HD 15kW. Rated output current: ND 38A / HD 31A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0038 | A1000 400V class AC drive/inverter; ND 18.5kW / HD 15kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0038 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 18.5kW / HD 15kW · Rated Input Current: ND 44A / HD 39A · Rated Output Capacity: ND 29kVA / HD 24kVA · Rated Output Current: ND 38A / HD 31A · Power Supply Capacity: ND 40kVA / HD 36kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0044. Maximum applicable motor: ND 22kW / HD 18.5kW. Rated output current: ND 44A / HD 39A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0044. Maximum applicable motor: ND 22kW / HD 18.5kW. Rated output current: ND 44A / HD 39A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0044 | A1000 400V class AC drive/inverter; ND 22kW / HD 18.5kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0044 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 22kW / HD 18.5kW · Rated Input Current: ND 52A / HD 44A · Rated Output Capacity: ND 34kVA / HD 30kVA · Rated Output Current: ND 44A / HD 39A · Power Supply Capacity: ND 48kVA / HD 40kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0058. Maximum applicable motor: ND 30kW / HD 22kW. Rated output current: ND 58A / HD 45A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0058. Maximum applicable motor: ND 30kW / HD 22kW. Rated output current: ND 58A / HD 45A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0058 | A1000 400V class AC drive/inverter; ND 30kW / HD 22kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0058 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 30kW / HD 22kW · Rated Input Current: ND 58A / HD 43A · Rated Output Capacity: ND 44kVA / HD 34kVA · Rated Output Current: ND 58A / HD 45A · Power Supply Capacity: ND 53kVA / HD 39kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0072. Maximum applicable motor: ND 37kW / HD 30kW. Rated output current: ND 72A / HD 60A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0072. Maximum applicable motor: ND 37kW / HD 30kW. Rated output current: ND 72A / HD 60A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0072 | A1000 400V class AC drive/inverter; ND 37kW / HD 30kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0072 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 37kW / HD 30kW · Rated Input Current: ND 71A / HD 58A · Rated Output Capacity: ND 55kVA / HD 46kVA · Rated Output Current: ND 72A / HD 60A · Power Supply Capacity: ND 65kVA / HD 53kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0088. Maximum applicable motor: ND 45kW / HD 37kW. Rated output current: ND 88A / HD 75A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0088. Maximum applicable motor: ND 45kW / HD 37kW. Rated output current: ND 88A / HD 75A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0088 | A1000 400V class AC drive/inverter; ND 45kW / HD 37kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0088 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 45kW / HD 37kW · Rated Input Current: ND 86A / HD 71A · Rated Output Capacity: ND 67kVA / HD 57kVA · Rated Output Current: ND 88A / HD 75A · Power Supply Capacity: ND 79kVA / HD 65kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0103. Maximum applicable motor: ND 55kW / HD 45kW. Rated output current: ND 103A / HD 91A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0103. Maximum applicable motor: ND 55kW / HD 45kW. Rated output current: ND 103A / HD 91A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0103 | A1000 400V class AC drive/inverter; ND 55kW / HD 45kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0103 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 55kW / HD 45kW · Rated Input Current: ND 105A / HD 86A · Rated Output Capacity: ND 78kVA / HD 69kVA · Rated Output Current: ND 103A / HD 91A · Power Supply Capacity: ND 96kVA / HD 79kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0139. Maximum applicable motor: ND 75kW / HD 55kW. Rated output current: ND 139A / HD 112A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0139. Maximum applicable motor: ND 75kW / HD 55kW. Rated output current: ND 139A / HD 112A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0139 | A1000 400V class AC drive/inverter; ND 75kW / HD 55kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0139 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 75kW / HD 55kW · Rated Input Current: ND 142A / HD 105A · Rated Output Capacity: ND 106kVA / HD 85kVA · Rated Output Current: ND 139A / HD 112A · Power Supply Capacity: ND 130kVA / HD 96kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0165. Maximum applicable motor: ND 90kW / HD 75kW. Rated output current: ND 165A / HD 150A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0165. Maximum applicable motor: ND 90kW / HD 75kW. Rated output current: ND 165A / HD 150A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0165 | A1000 400V class AC drive/inverter; ND 90kW / HD 75kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0165 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 90kW / HD 75kW · Rated Input Current: ND 170A / HD 142A · Rated Output Capacity: ND 126kVA / HD 114kVA · Rated Output Current: ND 165A / HD 150A · Power Supply Capacity: ND 156kVA / HD 130kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0208. Maximum applicable motor: ND 110kW / HD 90kW. Rated output current: ND 208A / HD 180A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0208. Maximum applicable motor: ND 110kW / HD 90kW. Rated output current: ND 208A / HD 180A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0208 | A1000 400V class AC drive/inverter; ND 110kW / HD 90kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0208 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 110kW / HD 90kW · Rated Input Current: ND 207A / HD 170A · Rated Output Capacity: ND 159kVA / HD 137kVA · Rated Output Current: ND 208A / HD 180A · Power Supply Capacity: ND 189kVA / HD 155kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0250. Maximum applicable motor: ND 132kW / HD 110kW. Rated output current: ND 250A / HD 216A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0250. Maximum applicable motor: ND 132kW / HD 110kW. Rated output current: ND 250A / HD 216A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0250 | A1000 400V class AC drive/inverter; ND 132kW / HD 110kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0250 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 132kW / HD 110kW · Rated Input Current: ND 248A / HD 207A · Rated Output Capacity: ND 191kVA / HD 165kVA · Rated Output Current: ND 250A / HD 216A · Power Supply Capacity: ND 227kVA / HD 189kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0296. Maximum applicable motor: ND 160kW / HD 132kW. Rated output current: ND 296A / HD 260A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0296. Maximum applicable motor: ND 160kW / HD 132kW. Rated output current: ND 296A / HD 260A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0296 | A1000 400V class AC drive/inverter; ND 160kW / HD 132kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0296 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 160kW / HD 132kW · Rated Input Current: ND 300A / HD 248A · Rated Output Capacity: ND 226kVA / HD 198kVA · Rated Output Current: ND 296A / HD 260A · Power Supply Capacity: ND 274kVA / HD 227kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |